Housing Urban and Rular Development Government Departments Closing in 19 days TDR #58176646

Tender For Construction Of Abc Center (Capacity Of 50 Cells) At Karharbari Giridih.

Issued by Government Departments · Giridih, Jharkhand
Tender Value
2.12 Crore
Estimated cost
Bid Submission
12 Nov 2026
19 days left
EMD
4.25 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Giridih → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Abc Center (Capacity Of 50 Cells) At Karharbari Giridih.

BOQ

Name of Work:- Construction of ABC Center (Capacity of 50 Cells) at Karharbari Giridih.
Sl. No. Item Description
1DSR 2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
2DSR 2.32.1 Felling trees of the girth (measured at a height of 1 m above groundlevel), including cutting of trunks and branches, removing the roots andstacking of serviceable material and disposal of unserviceable material. Beyond 30 cm girth upto and including 60 cm girth
3DSR 2.32.2 Beyond 60 cm girth upto and including 120 cm girth
45.1.1 Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
55.6.1 Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
65.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume).
75.3.1.6 Providing and laying in position cement concete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 cement :4 coarse sand (Zone -III) :8 graded stone aggregrate 40 mm nominal size)
85.3.26.1.1 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix including pumping of concrete to site of layinh but excluding the cost of centering ,shuttering finishing and reinforcement including admixtures in recommended proportions as per IS : 9103 to accelerate rated srtting of concrete, improve workability without impaiting strenth and durability as per direction of engineer in charge (note :- Cement content considered in this item is 330 kg/cum excess/ less cement used as per design mix is payable/ recoverable seperataly)All works upto plinth level - M25 Grade
95.1.7 Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
105.3.26.2.1 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix including pumping of concrete to site of layinh but excluding the cost of centering ,shuttering finishing and reinforcement including admixtures in recommended proportions as per IS : 9103 to accelerate rated srtting of concrete, improve workability without impaiting strenth and durability as per direction of engineer in charge (note :- Cement content considered in this item is 330 kg/cum excess/ less cement used as per design mix is payable/ recoverable seperataly)All works above plinth level upto floor V level - M25 Grade
11DSR 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources :6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
12JSOR 5.2.9 Providing designation 75A brickwork in CM (1:3) in superstructure with approved quality of clean coarse sand of FM 2 to 2,5 including providing 10mm thick mortar joints , cost of screening, materials, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as building specification and direction of E/I
135.4.1 Supplying, fiiting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors windows skylights fanlights and C/W celetial window opening including wedge over all clamps complete including application of two coats of wood preservative of approved quility onthe surface buttling walls and lintels all complete as per building specification anddirection of E/I.
145.4.38 Supplying fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutter door and windows with black board core blended with high quality phenol formal clehydes synihetic resin both side commercial veneered of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pe building specrfication and direction of E/l.
155.4.43 Supplying, fitting and fixing 30 mm thick solid core type non-decorative double leaf 1/3rd glazed flush shutter in windows
165.8.26 Primer, one coat, over new wooden surface (cleaning, sand paper)
175.8.32 Synthetic enamel, two coats, over new wooden surface
185.5.4 Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
195.5.5 (a) Providing Tor steel reinforcement of 10mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
205.5.5 (b),c Providing Tor steel reinforcement of 12mm. to 32mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
215.3.17.1 Centering and shuttering including strutting, propping etc and removal of form for Foundations, footings, bases for columns, etc for mass concrete
225.3.17.6 Centering and shuttering including strutting, propping etc and removal of form for Columns, Pillars, Piers, abutments, Posts and struts
235.3.17.5 Centering and shuttering including strutting, propping etc and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
245.3.17.3 Centering and shuttering including strutting, propping etc and removal of form for Suspended floors, roof, landings, balconies and access platform
255.3.11 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
26JSR-5.3.5 Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
275.7.3 Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
285.7.6 Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direction of E/I.
295.7.16 Providing 25mm thick water proof cement plaster
30BCD-5.8.24 Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I.
315.8.18 Providing two coats of oil bond Distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone of fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification direction of E/I.
32JSOR 5.2.9 Providing designation 75A brickwork in CM (1:3) in superstructure with approved quality of clean coarse sand of FM 2 to 2.5 including providing 10mm thick mortar joints, cost of screening, materials, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as building specification and direction of E/I
33DSR 12.21.1 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
34DSR 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse sand): 25 mm thick. (Kennels / Dog Wards / Heavy duty areas)
35DSR 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (Skirting for Kota stone areas)
36DSR 8.31 Providing and laying 1st quality Ceramic glazed wall tiles (thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.(Walls - Toilets, Wash areas, Scrub areas)
37BCD- 5.12.1 Roof/Terrace Waterproofing: Providing and laying waterproofing treatment on roof slab by applying two Component, factory designed ready to use, acrylic modified flexible cementitious material (surface preparation + 1st coat + glass fibre mesh + 2nd coat) – complete system as per BOQ specification. Brand: Sika / MYK Schomberg / Dr Fixit / Fosroc. Warranty 5 years. (Main terrace waterproofing treatment)
385.12.3 Covering of treated surface with PCC: Providing 50mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt × 2 mt panels with approved quality of stone chips of 20 mm to 6 mm size including curing etc. complete.
395.12.9 Providing and filling of 6 mm groove between 50mm PCC panels with 6 mm thick deep thermocol strip and filling the rest 25mm with polysulphide sealant (pouring grade) as per drawing and technical specification.
405.7.14 Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
41DSR 10.25.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksStaircase and gate
42JSR-5.5.12 Supplying, fitting and fixing M.S. grill made of 20×6 mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting and fixing in position in windows including cost of necessary welding, applying a priming coat of red lead paint over steel work, taxes all complete as per building specification and direction of E/I.
43DSR 10.25.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksCage
445.5.30 Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20×6 mm M.S. flats or 16 mm square bars fitted on 25×25×6 mm M.S. Angle frame including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
455.8.45 Synthetic Enamel Paint (2 coats) over steel
46Sand (10 Kms)
47Stone Chips (22 Kms)
48Stone Metal (20 Kms)
49Bricks (7 Kms)
50JBVNL Cost Data Book 795 Fire Buckets (Capacity 10 Ltrs.)
51JBVNL Cost Data Book 788 Fire Extinguisher - 4.5 kg Carbon Dioxide Type, Fire Rating: 21B
52JBVNL Cost Data Book 780 Fire Extinguisher - 6 kg Dry Chemical Powder (MAP 50%); Fire Rating: 3A, 34B
53DSR 2.34.1 Providing and injecting chemical emulsion for pre-constructional anti-termite treatment and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits etc. as per detailed specifications, complete as directed by Engineer-in-Charge. (Using emulsion of Chlorpyriphos / Lindane 20% EC mixed with water in the ratio 1:19 or as per IS 6313)
54JSR 3.2.1 A. SANITARY FIXTURES Supplying , fitting and fixing vitreous white glazed earthen ware I.W.C of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I 'p' trap 15 liters C.I.pull and let go flushing cistren of names or other I.S.S. equivalent make , complete with all fitting , C.I.or C.C. brackets 32mm alkathene/P.V.C telescopic flush , pipe about 2 M long with one brass coupling and clamps GI ,chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less thane 50grms. 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coats of red oxide primer etc. all complete as per specification and direction of E/I. (c) With 10 lit. low level PVC Cistem
55JSR 3.2.2 Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all completeas per specification and direction of E/I.(ii) E.W.C. with 'S' trap(b) 10 lit. low level PVC Cistem
56JSR 3.2.5 Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
57JSR 3.1.21 (i) Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings, 3mm ply wood board and C.P. hinges – 600mm x 450mm size.
58JSR 3.1.21 (b)Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror.(i) 600mm x 450mm size(c)(iii) C.P. brass liquid soap container
59DSR-18.49.1 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore
60DSR-18.52.1 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm dia nominal bore
61M.R. B. DRAINAGE INSTALLATIONS Providing, fixing, testing and commissioning of UPVC SWR pipe type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps etc. conforming to IS:14735-1999 and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint as required/applicable. 110 mm (OD)
62M.R. Providing, fixing, testing and commissioning of UPVC 'P' trap/floor trap/urinal trap of self cleansing design having 50 mm water seal with or without horn conforming to IS : 14735-1999 including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 hard stone ballast 20 mm nominal size) including cost of cutting and making good the walls & floors wherever required. 110 mm inlet x110 mm outlet.
63M.R. Providing, fixing, testing and commissioning of UPVC inlet fittings (hopper) receive waste from fixture waste with maximum 3 inlets 40, 50 & 63 mm OD size, fabricated from 110 OD UPVC SWR pipe, UPVC sockets, fixed to UPVC traps including solvent weld joint/rubber ring joint, complete with all civil work set in cement concreate 1:2:4 as required including cost of cutting and making good the walls & floors wherever required.
64MR Providing, fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class III including all moulding fittings40 mm (OD)
6550 mm (OD)
66M.R. Providing and fixing UPVC floor drain including all fitting and accessories fixed in cement mortar complete in all respect. 110 mm OD x 63 mm OD
67DSR-17.37.1 Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe
68DSR-18.58.1.2 Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole
69DSR 19.2.1 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) alround 100mm dia. SW / CI / waste pipes including bed concrete as per standard design
70DSR 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. 110 MM dia
71DSR 12.42.1 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler - 110 mm
7212.42.4 Single tee without door- 110x110x110 mm
7312.42.5.2 Bend - 110 mm
74DSR 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
75DSR 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
76DSR 18.10.4 C. WATER SUPPLY INSTALLATIONS Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (Exposed on wall Terrace) 32 mm dia, nominal bore
7740 mm dia, nominal bore
78DSR 18.8.1 Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting, including fixing the pipewith clampsat 1 m spacing. This includesjointing of pipes &fittingwith one step CPVC solvent cement and cost ofcutting chases and making good the same including testing ofjoints complete as per direction of Engineer in Charge.(Concealed work including cutting chases and making good the walls etc.)15mm nominal outer dia. Pipes.
79DSR 18.8.2 20mm nominal outer dia. Pipes.
80DSR 18.8.3 25mm nominal outer dia. Pipes.
81DSR 18.17.1 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)25 mm dia, nominal bore
8218.17.2 32 mm dia, nominal bore
8318.17.3 40 mm dia, nominal bore
84DSR 18.46.2 Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete.20mm nominal bore
8518.46.3 25mm nominal bore
8618.46.4 32mm nominal bore
87DSR-18.13.1 Making connection of GI distribution branch with GI main of 50-80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. 25 to 40 mm nominal bore
88DSR 18.40.4 Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality32 mm dia, nominal bore
8918.40.5 40 mm dia, nominal bore
90DSR-18.62.5 Provide and fixing PTMT ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with L.P/H.P.H.D. plastic ball 50 mm dia NB, 242mm long. Weighing not less than 1240 gms.
91DSR 18.18.3 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
92DSR 18.2.4 Providing and fixing Polyethelene-Aluminium- Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS : 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge.Concealed work, including cutting chases and making good the wall etc. (32MM DIA OD)
93DSR-18.48 D. WATER STORAGE TANK Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (i) Domestic and fire tank
94DSR 19.6.2 E. EXTERNAL SEWERAGE, MANHOLES & GULLY Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixtures of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 150 mm dia
95DSR 19.6.3 250 mm dia
96DSR-19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
9719.19.1.1 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5Rectangular shape 600x450 mm internal dimensions
9819.19.1.2 Square shape 450 mm internal dimensions
9919.21.1 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors – For pipes 100 to 250 mm diameter.
10018.33.1 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard designWith common burnt clay F.P.S.(non modular) bricks of class designation 7.5
101RUIDP 17.29.2 Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths full round HDPE DWC (double wall corrugated) pipes of SN8 grade as per IS 16098 (Part 2) amended upto date in trenches in complete including all material, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications, drawings and as per direction of Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable. 200 mm dia
102DSR-18.37.1 Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks
103PHED Page no-56 Item no.-M-1035 F. BORE WELL / TUBE WELL + SUBMERSIBLE PUMP + ELECTRICAL Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L.
104(b) From 51.0 M to125.00 M
105PHED -M1048 PG-63 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
106PHED -M1042 PG-63 Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
107DSR 23.13.3 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
108DSR 23.14.3 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
109SupplyPHD pg. - 64M 1055 Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP
110M-1065 PG.74 Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I.
111JH Energy M-1920 4 Core 4Sqmm. FR LS PVC Insulated Copper Conductor Cable ISI Marked
112PHED Page no-36 Item no.-M930-K+1051,PG51 Supply fitting and fixing lowering 40 mm dia G.L. column pipe - do - do - all complete job as per direction of E/I.
113JSR 1.3.1 ELECTRICALA. POINT WIRING IN PVC CONDUIT WITH MODULAR SWITCHESWiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group A
114DSR 1.55.1 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
115JSR 1.4 Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.
116JSR 1.5 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
117JSR 1.7.2 Wiring for circuit / sub-main wiring along with earth wire with 2 × 2.5 sq.mm + 1 × 2.5 sq.mm earth wire FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required.
118JSR 1.7.4 Wiring for circuit / sub-main wiring along with earth wire with 2 × 6 sq.mm + 1 × 6 sq.mm earth wire FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required.
119JSR 1.7.5 Wiring for circuit / sub-main wiring along with earth wire with 2 × 10 sq.mm + 1 × 6 sq.mm earth wire FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required.
120JSR 1.7.11 Wiring for circuit / sub-main wiring along with earth wire with 4 × 10 sq.mm + 2 × 6 sq.mm earth wire FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required.
121JSR 1.31 C. MODULAR ACCESSORIES (SWITCHES, SOCKETS, BOXES)Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections painting etc. as required. (For light plugs to be used in non residential buildings).
122JSR 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections painting etc. as required. (For light plugs to be used in non residential buildings).
123DSR 1.57 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
124JSR 2.9.6 D. DISTRIBUTION BOARDS, MCBs, RCCBs & ISOLATORSSupplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way (4 + 24), Double Door Horizontal Type
125JSR 2.8.9 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
126JSR 2.12.1 Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA \\"C\\" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required. 6/32 amps, Single pole
127JSR 2.12.10 50/63 amps, TPN
128JSR 2.14.1 Supplying and fixing following Rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 40 Amps
129JSR 2.15.2 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 63 Amps
130JSR 2.16.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 40 Amps
131JSR 9.5 E. INTERNAL LIGHTING FIXTURES & FANSSITC of following rating surface mounted LED tube light fitting suitable for 230V 50Hz single phase supply etc. complete as required. (20/22W LED Tube Light) (Primary lighting for rooms, corridors, dog wards)
132JSR-9.5.2 S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required. 20/22 W LED Tube Light
133JSR-M 869 Bulk Head fitting with 9/10 Watt LED (IP65 / weatherproof) for dog wards, utility rooms, external wall / corridor ends.
134JH Energy 9.5.1 SITC of following rating surface mounted LED tube light fitting suitable for 230V 50Hz single phase supply etc. complete as required. (10/12W LED Tube Light) (Primary lighting for rooms, corridors, dog wards)
135JSR-M 827 Supply & Installation of15/16 W LED Bracket / Wall Light fitting suitable for outdoor / semi-outdoor areas (entry, verandah, dog ward outer walls) complete with all accessories.
136JSR 9.4.3 Supply insttalation , testing and commisioning of following size ceiling fan 3 balde confirming to IS : 374:2019 incuding wiring thedown roads of standed lenth (upto 30 cm) with 1.5 sqmm PR PVC, insulated copper wire suitable for 230V 50Hz single phase supply etc. compleyte as required. 1200mm (48 Degree) BLDC 5 star rating 32W ceiling fan
137JSR 1.25 Supply and fixing of step type electronic fan regulator on existing modular plate switch box including connection but excluding modular plate etc as required.
138JSR 1.44 Installation, testing and commissioning of ceiling fans/bracket fan of all sizes including wiring the down rod .of standard length (up to 30 cm ) with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required.
139JSR M-775 SITC of 300 mm (12\\") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required
140JSR-9.1.6 F. EXTERNAL LIGHTING (COMPOUND, PARKING, ENTRANCE, PATHWAYS)S.I.T.C of Following rating LED Street Lighting luminare with pressure die cast housing and toughened glass cover (IP 66 protection ) in existing pole / pipe for supply voltage 100-270 AC 50Hz Luminare shall be confirm to IS :10322 part 5/ section-3 and shall be complete with all nessessary accessories as required.(Approved Make:- Havells / Philips / Crompton / Wipro). 70/72W LED Street Light
141JSR 9.2.4 S.I.T.C of Following rating LED Flood Lighting Luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC 50Hz. Luminarie shall be confirm to IS 10332 Part 5/section 5 and shall be complete with all necessary accessories as required. 90/100W LED Flood Light
142JSR M-742 Supplying & installation of 7 mtr. Height Octagonal Hot Dip galvanized pole (BOP. 7030) with top dia 70 mm bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12 mm (LxBxT) including suitable size of foundation bolt all complete as required (without Arm).
143JSR M-875 Testing & Commissioning of the 7 mtr Octagonal Pole & Light Fitting with the help of suitable tools and plants, and construction of shallow foundation with M25 grade concrete considering safe soil bearing capacity og 10T/sqmtr but excluding wire and mcb
144JSR 3.4 G. EARTHINGEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
145JSR 3.6 Earthing with Copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
146JSR 3.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
147DSR-5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc, as required
148JSR M736 H. POWER CABLES, LAYING & MISCELLANEOUSSupply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-7098. (Part-I). 2 core, 6 sq.mm.
149JSR 5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
150DSR 11.1.10 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required (35 sq.mm).
1512.5.2 LT PanelSupply, installation, testing and commissioning of the outdoor feeder-pillar cubicle for the ABC Centre main LT panel, floor or wall mounted, protection not less than IP54 to IS/IEC 60529. Fabricated from sheet steel not less than 1.6 mm thick, seven-tank treated and powder coated inside and outside, with a gasketed hinged door, padlockable handle, sloping top, slotted gland plate, earthing studs and a door-earthing braid. The cubicle shall be sized to house the 8-way vertical TPN distribution board, the 100 A 4-pole incomer, the outgoing MCBs, the metering and the indication lamps already measured separately, with working clearance for cable termination. Internal control wiring shall be stranded copper, 2.5 sq.mm for instrument circuits, ferruled and numbered both ends.The same item includes the metering set: three current transformers, 100/5 A, class 1.0, burden 5 VA, one per phase, on the incoming side; one flush ammeter 0–100 A with a three-position selector; one flush voltmeter 0–500 V with a selector; one 3-phase 4-wire kWh meter, class 1.0, CT operated, with a test terminal block and fuses on the voltage circuit.It also includes the indication lamps on the door: three LED lamps, red, yellow and blue, 230 V, one per phase, wired from the outgoing side of the incomer through control fuses, with holders and phase legends, and one white lamp engraved MAINS ON.Fixing includes foundation bolts or wall fasteners, glanding, earthing of the door and gland plate, ferruling, testing of the instruments and lamps, and making good. The distribution board, MCCB, MCBs, busbars and danger plate are paid under their own lines and are not included in this rate.Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
1522.2.13 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A, 30 KA 4Pole
1532.10.3 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
1542.10.5 Triple pole and neutral
1552.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1562.3.1 DB BoxSupply and fixing of a weatherproof enclosure for the external-lighting distribution board, protection not less than IP65 to IS/IEC 60529, polycarbonate or sheet steel with a gasketed hinged door, padlockable, with gland entries top and bottom, earthing stud and a canopy or drip shield. Surface fixed on wall or pole. The enclosure shall be sized to house one 6-way double-door SPN MCB distribution board and two SP MCBs, 6–10 A, already measured separately, with clearance for the incoming feeder and the outgoing light circuit. The item includes the glands, the earthing of the door, ferruling, termination of the incoming and outgoing cables, and testing. Quantity 4, one for each external-lighting group serving the six street lights and two flood lights. The distribution board and the MCBs are paid under their own lines and are not included in this rate. The board quantity in the estimate is still 1 and the MCB quantity 2; those become 4 and 8 to match these four enclosures.Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door
1572.10.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
158PAR 6.8.2 Boundary WallPrecast RCC wall in M40 grade concrete comprising shaped 250 x 230 mm RCC posts fixed in ground and 70 mm thick RCC wall panel inserts including MS Gate of 15' at appropriate locationTotal Length of Boundary Wall
159JSOR RCD 4.23B Providing & Laying 80mm Thick (M-40) CC Paver Block : Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M-40 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over bed as per relevant IRC Code, filling the joints with fine sand etc. all complete as per the direction of Engineer in - charge.White Paver Block @60%
160Red Paver Block @20%
161Yellow Paver Block @20%
1628.21.1 SOLAR LIGHTSupplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 20 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%), Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) Charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, With Lithium- Iron Phosphate Battery (LiFePO4),charging time 6-8 hours, Battery backup time 12 hours (minimum), LED fixture 20 watt, Input voltage: 12V DC, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, IP-66,IK-08, CRI >70 , under voltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPR 15, lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K / (As per American National Standard Institute (ANSI Bin)), life time (LED,Driver & electrical circuitry) of 50K hours lamp buring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic swich on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body), can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. All as per pre approved by Engineer in-charge complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, complete with mounting structure for the battery and accessories suitable for withstand wind storm speed as per the site location. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 20 Watt (System lumen efficacy >120 lm/Watt)
163DSR 23.5 RAIN WATER HARVESTINGA. FILTER MEDIA FOR RECHARGE PITSSupplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
164DSR 23.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
165DSR 23.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.
166DSR 12.41.2 B. UPVC RAIN WATER PIPESProviding and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. 110 MM dia
16712.42.1 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler - 110 mm
16812.42.4 Single tee without door- 110x110x110 mm
16912.42.5.2 Bend - 110 mm
170DSR 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
1712.2 LANDSCAPING ETC.Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
1722.25 Supplying and stacking of well decayed cow dung manure at site including royalty and carriage up to 1.0 km (cow dung manure measured in stacks will be reduced by 8% for payment).
1732.7 Fine dressing of the ground.
1742.9 Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge.
1752.8 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).
1762.12 Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
1772.14.2 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume – Holes 90 cm diameter and 90 cm deep (for trees).
1782.14.3 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume – Holes 60 cm diameter and 60 cm deep (for shrubs).
1792.14.4 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume – Holes 45 cm diameter and 45 cm deep (for ground covers).
1807.24 Delonix regia (Gulmohar / April Fool)
1817.16 Cassia fistula (Amaltas)
1827.5 Azadirachta indica (Neem)
1837.8 Bauhinia purpurea (Kachnar)
1847.14 Callistemon lanceolatus (Bottle Brush)
1857.74 Polyalthia longifolia (Ashok)
1867.72 Plumeria rubra (Pink Champa)
1877.7 Plumeria alba (White Champa)
1887.44 Foxtail Palm
1892.34 Cynodon dactylon (Doob Grass / Bermuda Grass)
190Add 18% GST
191Add 1% Labour Cess Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58176646
AUTHORITY Government Departments
TENDER VALUE 2.12 Crore
LAST DATE 12-11-2026
Authority
Authority Name Urban Development Department
Work Description Tender for Construction Of Abc Center (Capacity Of 50 Cells) At Karharbari Giridih.
Basic Detail
Tender No UDD/GMC/XXVII/01/2026-27
Bidding Type Tender
Location
City Giridih
State Jharkhand
Key Dates
Publish Date 23 Oct 2026
Submission Date 12 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 2.12 Crore
Tender Fee 10000
EMD 4.25 Lakhs
Exemption Not Available
Document List
3ed8760f-3665-4ef3-85c5-793bcd105522.html
BOQ_162600.xls
Technical.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

3ed8760f-3665-4ef3-85c5-793bcd105522.html

xls

BOQ_162600.xls

pdf

Technical.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender