Tender For Shifting Work Of Electrical Assets 11 Kv Ht/Lt Line From The Middle Of The Construction Work Of Kathgodam Bypass Motor Road From Kathgodam Gaula Pul To H.Mt Amritpur Under E.D.D (Town) Haldwani
Tender Overview
Project Description
Tender for Shifting Work Of Electrical Assets 11 Kv Ht/Lt Line From The Middle Of The Construction Work Of Kathgodam Bypass Motor Road From Kathgodam Gaula Pul To H.Mt Amritpur Under E.D.D (Town) Haldwani
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 31-Oct-2026 | Date Extenson 1 | Date | 12-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Total amount of the \\"Rate Schedule\\" sheet Schedule of Quantity and Rate for Shifting work of Electrical Assets 11 KV HT/LT Line from the middle of the Construction work of Kathgodam Bypass Motor Road from Kathgodam Gaula Pul to H.MT Amritpur under E.D.D (Town) Haldwani Against E-Tender Specification No. 60/EDC(H)/2026-27 Name of The Bidder's Firm: 0.0 Sl. No. Description of Work Unit Qty Rate Amount Part [A] (Supply Portion) |
| 2 | Holding Clamp for SP-55 with N/B |
| 3 | Bracing Clamp for SP-55 with N/B |
| 4 | Nut & Bolts |
| 5 | STAY CLAMP FOR SP-21 WITH NUT & BOLT |
| 6 | Stay Clamp for SP-55 With Nut & Bolt |
| 7 | SUSPENSION CLAMP WITH EYE HOOK |
| 8 | DEAD END CLAMP WITH J HOOK |
| 9 | STAY INSULATOR |
| 10 | SHEAR HEAD TYPE PRC 120 TO 25 SQ mm |
| 11 | 11 KV CABLE TIES FOR PIN INSULATOR |
| 12 | 11 KV IPC FOR COVERED TO COVERED COND. |
| 13 | 11 KV IPC FOR COVERED TO BARE CONDUCTOR |
| 14 | 11 KV MID SPAN JOINTING KIT |
| 15 | IPC WITH AL. BAIL FOR EARTHING 11KV |
| 16 | 11 KV Tension With Ball and IPC |
| 17 | ACSR DOG (INSULATED/COVERED) |
| 18 | LT DISTRUBITON BOX 3 PHASE |
| 19 | MS Half Clamp for LT Distribution Box Total - Part [A] 0.0 Part [B] (Labour Portion) |
| 20 | Erection & Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and conecting the earth electrode with the helpof G.I. Wire as per construction mannual |
| 21 | Fabrication of M.S. Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESSPO sehedule and local approved drawing. |
| 22 | Excavation of earth for Stay pit of size 0.6x0.6x1.2mtr in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 23 | Grouting of stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO Manuel . |
| 24 | Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 25 | ERECTION OF SINGLE SP-21 POLE |
| 26 | ERECTION OF SINGLE SP-55 POLE |
| 27 | ERECTION OF SP-55 DOUBLE POLE |
| 28 | Grouting of pole in size 0.45x0.45x1/5 of the support in CC ratio 1:4:8 (1 cement: 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO construction Manual. |
| 29 | Muffing of poles size 0.45 cm x 0.60 cm radious with cc 1:3:6 (1 cement: 3 coarse sand : 6 graded stone 10mm nominal size) block size 45cm height from ground level including cost of cement, stone and sand etc. |
| 30 | DISMANTLING OF SP-55 SINGLE POLE |
| 31 | DISMANTLING OF SP-55 DOUBLE POLE |
| 32 | DISMANTLING OF 11 KV LINE(DOG) |
| 33 | DISMANTLING OF GUARDING IN 11 KV LINE |
| 34 | LAYING OF DOG CONDUCTOR IN HT LINE |
| 35 | Guarding of Line over (Telephone / Road / L.T. line crossing as per drawing with 6/8 SWG G.I. wire including fixing of guarding channel/ angle as per RESSPO manual. LT./11KV /33KV |
| 36 | CARTAGE SP-21/23 POLE, 0-20 KM |
| 37 | CARTAGE SP-55 POLE, 0-20 KM |
| 38 | CARTAGE OF PETTY MATERIAL,0-20 KM |
| 39 | HEADLOAD CARTAGE SP-21/23 POLE(0-1 KM) |
| 40 | HEADLOAD CARTAGE SP-55 POLE(0-1 KM) |
| 41 | DISCONNECTION & RECONNECTION OF CONsumer |
| 42 | DISMANTLING OF AB CABLE |
| 43 | LAYING OF LTXLPE ABC 3X120+1X95 +1X16 SQ. |
| 44 | SERVICE OF HYDRA MACHINE |
| 45 | TIGHTENING OF STAY SET |
| 46 | DIGGING OF PIT THROUGH HAMMER AT CC, DAM |
| 47 | BACK CARTAGE OF PETTY MATERIAL,0-20 KM |
| 48 | INSTALLATION OF LT DISTRIBUTION BOX |
| 49 | FIXING OF IPC WITH AL. BAIL FOR EARTHING |
| 50 | FIXING OF 11KV 90KN TENSION CLAMP B&IPC |
| 51 | FIXING OF 11 KV IPC FOR CC TO CC COND. |
| 52 | FIXING OF 11 KV IPC FOR CC TO BARE COND. |
| 53 | FIXING OF 11 KV MID SPAN JOINTING KIT |
| 54 | HEAD LOAD CART. OF PETTY MAT. ABOVE 3KM |
| 55 | 11 KV CABLE TIES FOR PIN INSULATOR |
| 56 | LOOPING AND CHOPPING OF TREE BRANCHES Total - Part [B] 0.0 TOTAL [Part-(A) + Part (B)] 0.0 GST: EXTRA Place Date Superintending Engineer Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender