Housing Urban and Rular Development Government Departments Closing in 10 days TDR #58173627

Tender For Modernization / Upgradation Of Govt. Hss Sudhmahadev, District Udh Ur. (Under Ut Capex Budget 2025-26)

Issued by Government Departments · Udhampur, Jammu and Kashmir
Tender Value
5.12 Crore
Estimated cost
Bid Submission
13 Nov 2026
10 days left
EMD
10.24 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Modernization / Upgradation Of Govt. Hss Sudhmahadev, District Udh Ur. (Under Ut Capex Budget 2025-26)

BOQ

Name of Work:- Modernization / Upgradation of Govt. HSS Sudhmahadev, District Udh ur. (Under UT Capex Budget 2025-26)
Sl. No. Item Description
1Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
2Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
3Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
4Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size.
5Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
6Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level.
7Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. All works above plinth level upto floor V level.
8Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto/above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
9Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Riveted and bolted
10Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch inhorizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gram/m2.
11Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns for mass concrete.
12Centering and shuttering including strutting, propping etc. and removal of form work for: Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs andsteps etc.
13Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts.
14Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.
15Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms.
16Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide.
17Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
18Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
19Brick work with common burnt clay F.P.S (Non-modular) brick of class designation 7.5 in foundation and plinth in 1:6 (1 cement : 6 coarse sand).
20Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level.
21Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)
22Extra for half Brick masonry in superstructure above plinth level upto floor V level.
2312mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand)
2415 mm cement plaster on the rough side of single or half brick wall of mix 1:6 ( 1 cement 6fine sand )
256 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
26Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections
27Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
28Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
29Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of size 300x450mm as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
30Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick.
31Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
32Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats.
33Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm).
34Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
35Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
36Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete.
37Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood
38Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
39Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of requiredsize with necessary screws 35mm.
40Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm.
41Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class deodar wood 30mm.
42Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class deodar wood 30mm.
43Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc.
44Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
45Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
46Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x75x4 mm.
47Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 75x63x4 mm.
48Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm.
49Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm.
50Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm.
51Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm.
52Providing and fixing aluminium handles lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
53300 mm long
54200 mm long
55125 mm long
56Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Twin rubber stopper.
57Providing and fixing of door Lock with necessary screws/nuts etc. complete:
58Plumbing & Sanitary Providing and fixing white vitreous china pedestal type water closet (European type W.C . .pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures, complete including cutting and making good the walls and floors wherever requied W.C. pan with lSI marked white solid plastic seat and lid.
59Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
60Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever.
61Providing and fixing wash basin with C. I./M.S. brackets,15mm C.P. centre hole basin mixture, 32 mm C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China round wash basin size 405x355 mm with a pair of 15 mm C.P. brass pillar taps.
62Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
63Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms.
64Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fitting complete. Flexible pipe 40 mm dia
65Providing and fixing 100 mm CP grating (hole or without hole) for gully, floor or Nahani trap.ISI marked all complete .
66Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete ISI marked as approved by Engineer incharge at site.
67Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes.
6875 mm diametre
69110 mm diametre
70Providing and fixing on wall face un-plasticized - PVC mouldedfittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
71Bend 87.5° 75 mm bend
72Bend 87.5° 110 mm bend
73Providing and fixing on wall face un-plasticized - PVC moulded fittings/ accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
74PVC Door bend 75 mm dia.
75PVC Door bend 110 mm dia
76Single tee without door 75x75x75 mm
77Single tee without door 110x110x110 mm
78Single tee with door 75x75x75 mm
79Single tee with door 110x110x110 mm
80PVC REDUCER DOOR TEE:- 110 mm x 75 mm
81PVC REDUCER PLAIN TEE:- 110 mm x 75 mm
82PVC OFFSET 75 mm dia.
83PVC OFFSET 110 mm dia
84Coupler 75 mm
85Coupler 110 mm
86PVC VENT COWL:- 110 mm dia
87PVC FLOOR /NAHANI TRAP:- 110 mm x 75 mm
88PVC FLOOR /NAHANI TRAP:- 110 mm x 100 mm
89Providing and fixing Soap dish (C.P. brass) with brackets ,nuts & screws complete etc.
90Providing and fixing (C.P. Brass ) towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
91Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms 15 mm nominal bore.
92Providing and fixing C.P. brass stop cock ( concealed) of standard design and of approved make concorming to IS : 8931 15 mm nominal bore.
93Providing and fixing C.P. brass angle valve for basin/ wall mixer and geysers points of approved make conforming to IS : 8931 15 mm nominal bore as approved by site incharge.
94Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore.
95Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge all complete .
96Providing and fixing 15 mm nominal bore of standard back type C.P. Brass close hole basin mixer pillar tap of approved quality and make weighing not less than 1.970 kg.
97Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work-Exposed on wall
9815 mm dia. nominal bore (medium)
9925 mm dia. nominal bore (medium)
100Making connection of G.l. distribution branch with G.l. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete all complete including testing of pipes and fittings and joints for leakage with pressure pump etc. as approved by site incharge.
10125 to 40 mm nominal bore
102Providing and fixing G.l. Union in G.l. pipe including cutting and threading the pipe and making long screws etc. complete (new work) all complete including testing of pipes and fittings and joints for leakage with pressure pump etc.as approved by site incharge 25 mm nominal bore
103Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
104Providing and fixing G.I.TANK NIPPLE of suitable dia. as approved by engineer incharge at site all complete including testing of fittings and joints for leakage etc.:- 32 mm dia. nominal bore.
105Providing & fixing BRASS BALL VALVE of approved quality conforming to IS : 8931 as approved by site incharge
10625 mm nominal bore
10740 mm nominal bore
108Providing and fixing of stainless steel Rainwater Khurra JALI to be placed at roof and mumty levels all complete:- square or circular in shape of dia/size:- 150mm
109Providing & Installation of 1.5 H.P. three phase water pump of make Crompton with all fittings, connecting inlet & outlet, fixtures, electrical connection and starter all complete:-
110Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) R.C.C. top slab with 1 :2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finsihed with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.l. cover with frame (light duty) 455x610 mm. internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg):- With F.P.S. bricks with class designation 75 & with Crushed stone aggregate.
111Making soak pit 2.5 m diameter 3.0 metre deep with 45x45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design by way of earth excavation by mechanical means; laying of 100 mm thick P.C.C. bed in 1:4:8 mix ratio & R.C.C. Slab on top in 1:1.5:3 mix ratio; providing and fixing of Manhole with MS frame and cover having passing of 50 mm dia. Vent air pipe through it for foul gases; brick masonry in 1:6 cement mortar mix with providing of pores; and filling of brick bat aggregates around the dry brick honey comb shaft; P/F of pvc bend/tee at the S.W. Drain pipe; all complete etc:- With F.P.S. bricks and Crushed.
112Supply & fixing CI cover with frame for manhole in sump / septic Tank 455 x 610 mm rectangular CI cover ( light duty ) the weight of the cover to be not less than 23 kg.
113Carriage 0f material by mechanical transport including loading ,unloading and stacking completed Sand lead up to 97 km av. and manual means lead upto 400 mtr av.
114Carriage of material by mechanical transport including loading ,unloading and stacking completed stone aggregate below 40 mm lead up to 50 km. average and manual means lead upto 400 mtr av.
115Carriage of material by mechanical transport including loading ,unloading and stacking completed Bricks lead up to 115 km. a av. and manual means lead upto 400 mtr av.and manual means lead upto 400 mtr av.
116Carriage of material by mechanical transport including loading ,unloading and stacking of building rubbish for lead up to 5 km av. and manual means lead upto 400 mtr av.
117Boundary Wall Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
118Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
119Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
120Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level.
121Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto / above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
122Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
123Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand).
12412mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 coarse sand)
125Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
126Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (2100mm hight)
127Retaining Wall Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil :
128Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
129Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level.
130Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge.All works above plinth level upto floor V level.
131Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto/above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
132Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns for mass concrete.
133Centering and shuttering including strutting, propping etc. and removal of form work for: Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs andsteps etc.
134Providing & fixing 100 mm dia PVC Pipes for weep holes in cement concrete wall/return wall of make PRINCE or equivalent, extending through the full width of the structure at mid height of wall @ 1 metre spacing with slope of 1 V: 20 H as per direction of engineers in charge incuding all carraiges.
135Dismantling of Existing Structure Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar.
136Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead : Of area of 3 sqm. and below.
137Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:In cement mortar.
138Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix).
139Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet.
140Dismantling of wooden Ballies in posts and strutsd incl. stacking within 50 mtr lead.
141Carpenter
142Labour
143Engaging Labour for dismantling wooden truss/ purlins/ vertical posts etc complete.
144Rain Water Harvesting Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
145Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
146Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
147Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
148Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.. All works upto plinth level.
149Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto/above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
150Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
151Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
152Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms.
153Brick work with common burnt clay F.P.S (Non-modular) brick of class designation 7.5 in foundation and plinth in 1:6 (1 cement : 6 coarse sand).
15412mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand)
155Providing and fixing unplasticised - Rigid PVC PIPES conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap of thermal expansion; with necessary stays/clamps with fasteners having working pressure of 4kg/cm2 all complete including testing of joints and pipes for leakage etc.:-
156Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800(part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipment tools plants and machineries required for the job, all complete as per direction of Engineer-in-charge upto 90 m depth below ground level. Rocky strata including boulders 300 mm dia.
157Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc all complete for all depths as per direction of Engineer-in-charge. 150 mm nominal size dia.
158Supplying, filling, spreading and leveling stone boulders of size range 5 cm to 20 cm, in recharge pit in the required thickness for all leads and lifts all complete as per direction of Engineer-in-charge.
159Supplying, fllting, spreading and leveling gravels of size range 5 mm to 10 mm, in recharge pit over the existing layer of boulders, in the required thickness for all leads and lifts all complete as per direction of Engineerin-charge.
160Supplying, filling , spreading and leveling coarse sand of size range 1.5 mm to 2 mm, in recharge pit in required thickness over the gravel layer, for all leads and lifts all complete as per direction of Engineer-in-charge.
161Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe removable as per requirement all complete for bore well of : 150 mm dia.
162Electrical Items Wiring for light points/fan/ exhaust fan point/call bell point point with 1.5 sq mm FRLS / HFFR PVC insulated copper conductor single core cable in surface/resessed medium class PVC conduit with modular switch, modular plate, suitable Gl box and earthing the point with necessary1.50 sq mm FRLS/HFFR PVC insulated copper conductor single core cable etc as reqd, all job complete (Group A).
163Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required
1642 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire.
1652 X 4.0 SQ.MM + 1 X 4.0 SQ.MM Earth Wire.
1664 X 6.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire.
1674 X 16.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire.
168Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm.
169Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair.
170Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 run of cable.
171Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm.
172Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1735/6 amps switch
1743 pin 5/6 amp socket outlet
17515/16 amp switch
1766 pin 15/16 socket outlet
177Telephone Socket outlet
178Computer Socket (RJ 45)
179Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
180Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
181Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1821 or 2 Module (75mmX75mm)
1833 Module (100mmX75mm)
1844 Module (125mmX75mm)
1856 Module (200mmX75mm)
1868 Module (125mmX125mm)
18712 Module (200mmX150mm)
188Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.
189Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings.
190Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
191Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
192Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular DP MCB, \\"C\\" curve including connections, painting etc. as required.
193Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way (4 + 24), Double door.
194Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required 12 way (Double door).
195Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
196Single Pole 6 to 32 Amp
197Single pole and neutral 6 to 32 Amp
198Triple pole and neutral 6 to 32 Amp
199Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A TPN MCB 10 Ka \\"C\\" Curve.
200Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
201Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
202Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
203Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
204Earthing with Copper. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
205Providing and fixing 25 mm X 5 mm copper. strip on surface or in recess for connections etc. as required.
206Providing and fixing 6 SWG dia copper. wire on surface or in recess for loop earthing as required.
207LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 40 watt.
208Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. 1200 mm.
209LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 100 Watt.
210LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 18 Watt.
211Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. 300mm/12\\" sweep exhust fan.
212Supply installation testing and commissioning of IP:20 Aluminium Batten 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV. Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab.
213SITC of Raw Power Distribution Panel Indoor (IP:42) free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
214INCOMER 160 A,36KA,FPMCCB
215100 A,36KA,FPMCCB
216Aluminium Bus Bar 200 Amp set of 4 strips 18\\"
217Aluminium Bus Bar 300 Amp set of 4 strips 18\\"
218Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.
219OUTGOINGS ON Load Change Over Switch FP 160 amp. (Front operated)
220100 A,36KA,FPMCCB
221Triple pole and neutral 63 Amp
222Triple pole and neutral 32 Amp
223Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
224120 mm dia (OD-120 mm & ID-103 mm nominal)
22563 mm dia (OD-63 mm & ID-51 mm nominal)
226Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.
2273.5 C X 70 Sq.mm A2XFY
2283.5 C X 25 Sq.mm A2XFY
229Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet).
2303½ X 70 sq. mm (38mm)
2313½ X 25 sq. mm (28mm)
232Supply installation testing and commissioning of 2.2 KVA Sine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery.
233Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U Rack.
234Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with original Krone module and Back Mount Frame and have Lock-n-key, complete in all respect as per specification and desired by EIC.
235Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
236Copper Patch Cords of length 1m (3ft)
237Copper Patch Cords of length 3m (10ft)
238LED Display Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170/170, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required 55 inch or larger
239Supplying Installation Testing and commissioning of 4MP IP IR Outdoor Dome Camera having following specifications and features cic 11 Signal System PAL/NTSC, Signal to Noise Ratio: > 50 dB, Camera should display Camera title, Date & Time in live & recorded video 2)image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition(Minimum lumination 0.006 Lus FI 4, AGC ON, 0 lux with IR or bettern True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)-Inbuih IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control, White Balance-Auto, Rack Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking 3) Compression (Minimum); Video: H.265 or better, Audio-G.711U/A, G.711M G.726, AAC. G. 723 4) Wide Dynamic Range:-WDIR (120dB or more) 5) Digital Noise Reduction: DNR (JD) On/Off 6) Video treaming & Frame Rates Triple streaming, configurable Main stream: 4MP (2560×1440) 25/30fps Sub streams minimum: 720P 25/30 fps 7) Image Setting Route Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser. Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering. HTTPS, trusted upgrade.
2409) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GR. It should be supplied with minimum 128GB memory Card. 10) Recording Management, Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger Motion/tampering detection; network disconnection detection, IP conflict detection, memory card state detection, memory space detection 12) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP. NTP, RTP, HTTP, HTTPS, SNMP TCPAP, PPPOE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio: It should support 1 x Built-In Mic and 1/1 Alarm In/Out for External Mic. and Speakers as per site requirement, 163 Power Input: The camera should support simultaneous dual power input-12 VDC (via power adapter) and PoE (802.3af)to ensure ontinuo operation in the event of a failure in one power source. 17) Power Requireinent: 12VDC/24 VDC/PoE (802.3af/ePoE 15) Housing/ Enclosure: IP67 weather proof, IK 10, Metallic body 40.4.1 40.4.2 19) Operating Conddition:- Ambient Temperature:-(105°C to 50°C, humidity 95% (max) (non-condensing) 203 IR life: 40000 hours or higher 21) Vidco Bit rate: 32 KBPS-8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoffS 4MP 25/30fps/@1440P (2560x1440) OutdoorDome Camera with 2.7 to 4 mm -12 to 13.5mn or better Varifocal Motorized lens.
241Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licences to record for all channels having specifications and features etc as mentioned below: 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultancously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth. 2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support 3) Must support I channel Input, 1 channel Output, RCA for Two-way Talk 4) Intelligent audo power on when power resumes afier power outage. 5) Storage. It should support 5) Connectivity Interface 1 minimum 2 SATA Slots with 20TH capacity/ Slot,Nos x 10/100/1000 Mbps Ethernet Ports, 1x R5485, 1x RS232 7) Backup Interface. Its should have 2. Nosx USB port 1x USB3.0, 1xUSB2.8) Video Output Ports: 1x HDMI and I VGA 9) Alarm Ports. It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter 10) Email & siren cic. SMS Altert options Option for SMS/ Enail Alerts to minimum 5 designated mobile number for power failure, IDD failure, vandalism, tempring, network disconnection and paruc 11) Web & Mobile Application: Web, Mobile app For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCPAP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Scarch, Multicast, Auto Registration, ONVIF (Profile T. Profile 5. Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public II need.
24213) Standards: CE, FCC, Rolls and BIS Certifiol Amp of AC100-240V, 50/60Hz Power supply. 14) Power Supply: Should support 12VDC, 15) Operating Condition: Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)14) Power Supply: Should support 12VDC, 15) Operating Condition: Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing) 16) The VMS, NVR application shall support all the features & functionalities of the offered cameras 17) VMS should consist of Base license and Channel Licemes. VMS should be provided with camera Licenses, with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality, (18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet 7680x4320 (KK), 3840*2160, 1920×1080, 1280-1024,1280-720, 1024-768 21) Must support recording resolution apto 32MP 22) Must support Continuous, Aların, Motion, Instant, Punic Recording Mode 203 Must support Resolution: 23) When alarm recording is enabled and an event occurs, you can click the alarms icon on morutoring page to view the alert details. The snapshot function is supported on monitoring and playback page.
24324) The Network Vateo Recorder (NVR) shall be configured to send email whenever a system message is created or an alarra event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarin occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 25) It should support Network Support: HTTP, TCPMP, SMTP, DHCP, DNS, DDNS, FTP, NTP, Convert multiple recording files to one avi/MP4 file UPal, Mulu IP Setting. Search Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 26) General Al Based 27) Alarmt otifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd dottribution, heat map, Disk Fuli, Storage Ertor, IP Conflict and almsormal behavior of fan 28) Alarm Noofication should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 29) Bush-le Artificial Intelligence: NVR should have built-in Al-2 Channel face detection and recognition, Minimum 4 Channel perimeter protection, Minimum & Channel Somart Motion Detection.
24430) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces of more with Face Detection. speed of 12 face images/sec 31) Face & Human Attributes Search: Search Pictures/Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella 32) ANPR Capability: It should support ANPR Camera with Liceuse plate, plate color, vehicle body, vehicle model, vehicle loga, calling, seatbelt, vehicle registration location etc vehicle attributes. 33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map. Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 35) General Al Based Scarch: Search Pictures by channel, tene, eveni type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 36) Smart playback function. Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics. 16 Channel Network Video Revorder (NVR) having display split-Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
245Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, ROM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications 10TB (Terabytes).
246Supplying and Laying of 20 Mir HDMI Optical Fiber Cable AOC 20, 4K with Bandwidth 18Gbps.
247Supplying and Fixing of S.D Card 256 G.B in the Existing Camera.
248SITC of CAT 6 F/UTP 16 Port Modular fully loaded patch Panel TIA/EIA-568-C-2:2009 EN 47 50173-1:2011 Class E, ISO/IEC11801:2010 (Ed 2.2) Class E, FCC Subpart F68.5 UL. Listed. Make-MOLEX/ BELDEN/PANDUIT/ PRIMUS, Legrand.
249Supply, Installation, Testing and Commissioning of 16-Ports 10/100/1000Mbps PoE+ 2-Ports SFP 100/1000Mbps Smart Managed Switch, 130Watts. Switch Should Support 8 x 10BASE T/100BASE-TX/1000BASE-T POE Ports 2 100/1000 Mbps SFF ports, auto-negotiatiation ports, 130 Watts Power Budget Switch Should Support Min. 20Gbps Switching Capacity and Maximum 64 Byte Packet Forwarding Rate is 14.80Mpps. MAC Address Table: BK and 4.1 MBits Packet Buffer, 256 Static MAC Entries Switch Should support Time based POE & CPU Protection Power Saving (Green) EEE 802.3az Energy Efficient Ethernet (EEE). Switch Should Support 4 Queues per port, Traffic Prioritization 802.1p. Strict Priority, Bandwidth Control: Port-based (Ingress/Egress, min granularity 10/100/1000 is 16 Kbps), Switch Should Support Access Control List based on: 802.1p priority, VLAN, MAC address. Ether type, IP address, DSCP, Protocol type, TCP/UDP port number, Ilve Traffic Class, Max. ACL Profiles/Rules: 50/768,Switch Should Support 802.1X Authentication, Max. 128 entries when using local database, IPv6 RADIUS server, MD5 authentication, Switch Should Support DoS attack prevention, Port Security: Max. 64 MAC Addresses per Port, Broadcast/Multicast/Unicast Storm Control, DHCP Server Screening, Support 2 IP Interface & IPv6 Neighbour Discovery (ND), Traffic segmentation, Switch Should Have FCC Class ACE Class A.IC Class A, UL Certifications. (Make Dlink, CISCO).
250Supply, Installation Testing and Commissioning of Media Converter.
251Supply & Erection of Termination Box complete as per specification and as desired by EIC.
252SITC of High performance 2-way Indoor/Outdoor full range speaker with 4\\" (1.5) VC, 1 x 0.8\\" dome tweeter High Frequency driver, Power Handling (AES Standard 40W RMS/60W Program/160W Peak or above, Nominal Impedance 16ohm, Frequency Response 70Hz-20KHz or better, Average Sensitivity 88dB/W/m or above. Calculated Max SPL 110dB Peak or better, Nominal Directivity 90° x 60° conical better, ete as required.
253SITC of Mixer amplifer with Total output all channels driven: 480W, 4-16 ohm, 70V/100V output, USB/Bluetooth Media player, 3 Aux and 2 microphone inputs, Signal-to-Noise Ratio 52 75dB, toroidal transformer, Master, Bass & Treble controls for tailored audio tuning Aux output available for daisy chaining amplifiers or to attach active subwoofers to expand your audio setupetc as regd.
254SITC of High Performance Digital Wireless dual Lapel microphone system. 200 selectable frequencies, RF Carrier Frequency Range CH1: 612.000-651.600 MHz (100 Selectable Frequencies) CH2: 652.000-691.600 MHz (100 Selectable Frequencies), Audio Frequency Range 30Hz-20 kHz, Signal-to-noise (A-weighted)- 120dB(A), RF output-50 mW max. Oscillation Mode Inside the chip VCO oscillation True Diversity dual reciever, Dual channel 19 one U rack mount receiver with four antennas, Two wireless bodypack transmitters with two lavalier & head worn microphone sets, Long range low power consumption, etc complete as required.
255SITC of 75 Interactive Touch Display with Panel Technology IPS/ Direct LED, Aspect Ratio-16:9, Resolution-3840x2160-4x UHD, Brightness - 350 cd/m2, Inbuilt Memory 4 GB RAM & 32 GB memory, Android: v11.0, CPU: Quad Core, Estimated Life Time: 50000 Hrs [Typical), Viewing Angle (HxV)-178x178, Touch technology: Infrared. Touch Point: 20. Response Time: 8ms, Surface Protection: 4mm Thick Touchened Glass, Touch Tools: Finger, Stylus, Glove, Opaque objects, Inputs: 1 x mini AV/ 1 x HDMI 2.0, Output: 1 x Coax, 1x Mini AV, 1 x Earphone Out/ 1 x USB-B, 1 x USB-A 2.0, 1x USB-A3.0, 3x USB-A 3.0, 1x USB-B 3.0. 1xUSB-C, 1x RJP45 Input, 1x RJP output, 1 x RS232C, 3+1 (WiFi + Bluetooth), Expansion: Windows OPS: Intel Statandard 80 Pin OPS-Inbuilt, etc complete as required.
256SITC of 8 input 8 output DSP Matrix Processor High-performance 400 MHz floating-point DSP processor, dual-core 1.2G main processor Linux platform, ultra-low noise circuitry, low distortion analog circuitry Using ELNA capacitors, selected audio-specific devices, to minimize the impact of sound coloring Minimum fixed delay of the device is <2ms Built-in 55 signal generator sine wave signal, Pink noise, White noise Parametric equalizer type: PEQ/Lo-Shelf/Hi- Shelf High and low pass filters: Bessel/Butterworth/ Link-Riley slopes selectable from 6-48dB/Oct, Sampling Rate-48kHz, 24 bit ADC & DAC, THD + Noise <0.004% @4dBu 20Hz-20kHz, Frequency Resporse 20Hz-20kHz, ±0,5dB @0dBu Crosstalk-100dB ±5dB @ 0dBu 1Khz. MIC oreamo gain-0-40dB Analog Gain, 12dB Digital Gain.
257Supply, Installation, Testing and Commissioning of PTZ Camera:12X Optical Zoom, 60fps. Digital 16X: Iris: f-5.5-110mm F1.6 F3.5:Viewing Angle:3.3 (tele) -60° Wide: Sensor: 1/2.8inch or better CMOS sensor, Mega Pixels: 2.07: Video Format: SDI Video Formats: 1080P60/50/30/25/59.94/29.97; 1080160/50/59.94.720P/50/30/25/59.94/29.97; Minimum illiumination:0.5 Lux DNR:2D & 3D DNR; White Balance: Auto/Manual/One push 3000K/3500K/4000K/4500K/5000K /5500K/6000K /6500K 7000K: Electronic Shutter: Auto/Manual; Focus: Should be Auto/Manual/One Push: BLC:ON/Off; WDR: Off/Dynamic level adjustment; Video Adjustment: Brightness, Color, Saturation, Contrast, Sharpness, B/W mode, Gamma curve, SNR: >55 dB;Interface: USB 2.0 x1, LAN x1, RS232 x 1; Audio In Video Compression Format: H.265/H.264; Control Protocol: VISCA/PELCO-D/ Pelco-P; Baud Rate: 11520/9600/4800/2400; LAN Port : Yes; Network Protocol: RTSP/RTMP/ONVIF, GB/T28181; Pan Rotation:+ 170° Tilt Rotation:-30~+90'; Pan Control Speed: 0.1-60/second Tilt Control Speed: 0.1-30'/second Preset Speed: Pan: 60/second, Tilt 30/second Preset Number:255 preset, etc. complete as required.
2584x2 HDMI 4K60 Matrix switcher with Interface Standard: HDMI 2.0, Supported Bandwidth: 18Gbps, Maximum Resolution: 3840x2160@60Hz4:4:48bit, HDCP Support: 2.2, HDMI Audio Pass through, Toslink (Optical) Upto 5.1CH, Stereo Analogue, IR Support: 38kHz, Control: Push Button, IR, Special Features: EDID Management, ARC Support, 4K-1080p Downscaling Functionality, Dual Audio Extraction, etc complete as required.
259Supply, Installation, Testing & Commissioning of HDMI Extender Kit. Must extend over ethernet cable HD singal minimum upto 60 mtrs & 4K UHD signal minimum upto 40 mtrs. Must require no adjustment or Tunning. HDMI 1.4 Compliant, HDBaseT, HDCP compliant, Must Support Embedded HDMI Audio, Including Dolby® TrueHD and DTS-HD Master Audio. Bandwidth: 3.4 Gbps or better, should Supports HD 3D formats & PC resolutions up to WUXGA, HDCP Repeater and CEC bypass, Bi-directional infrared remote control extensions. Operating temperature: U to 40°C of better & Storage temperature: -20 to 60°C or better.
260Supply, Installation, Testing & Commissioning of Pop-up Cable Cubby having 1 no. HDMI 1 RJ45 and 1 no. power socket etc. as required.
261Supply, Installation, Testing & Commissioning of HDMI to HDMI cable 1.5 Mtr etc. as reqd.
262Supply, Installation, Testing & Commissioning of 18U pre-wired Audio Equipment's Rack front lockable glass door, fan tray for cooling, caster wheels base, main panel with spike buster, individual fuse power supply unit, including all internal wiring, etc as required.
263Supply Laying & Fixing of of Microphone lines high grade, professional low-noise, 2 crore high conductivity PVC insulated in PVC jacket, shielded copper cable with Di- electric insulator both end with XLR m/f connector as required.
264Supply Laying & Fixing of speaker b lines: 2 core, 1.5 sq mm high defintion speaker cable. PVC insulated in PVC jacket laid in existing conduits as reqd.
265Online UPS-Input supply: Single Phase, Output Supply: Single Phase.Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery V AH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads.
266Current total harmonic distortion (THD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/-0.2Hz. Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 OC, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 KV surge. Display for att/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3).
267The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and nterconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 3KVA.
268Supply, installation with foundation as per approved Drawing 11 Mtr SP. 56 M.5 Pole.
269Supply installation of Structural Steel as per Standard Approved Drawing.
270Supply, Installation and Commissioning of 11 KV Air Break Switch (200 Amps).
271Supply, Installation of Gapless Surge Arrestor,9 kV 10 kA LA with polymer housing. Stn. Type.
272Supply, Installation of 11 KV HG Fuse Unit.
273Supply, Installation of Disc Insulator(B&S)70 KN suitable for 100 sq.mm Triple AAAC.
274Supply and Installation of 100 Sq mm AAAC Triple AAAC.
275Supply, Installation of 11 KV Pin Insulator suitable for 100 sq.mm Triple AAAC.
276Supply and Erection of 150 mm Dia. Heavy Class G.I Pipe for the Cable Protection.
277Supply and Installation of Anti Climbing Device.
278Supply, Installation and Commissioning of 11 KV Meter with suitable size Out door Type combined C.T and P.T's of 5/5A Accuracy Class 0.5 5 Burden 100 VA 11 KV/Root3/110 V/Root3.
279Supplying, installation, testing and commissioning of following capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender), 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with Offload Tap Changer in range of +5% to-15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and taying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to 15: 2026 (Part 1 to Part 5), IS: 1180 and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla.
280The permissible temperature-rise shall not exceed 35 OC for oil and 40 OC up to 200 KVA and 40 OC for oil and 45 OC for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition: a) air temperature 500C, b) Relative Humidity 90% Max, c) Seismic Zone as per focation of site, d) Altitude as per location/site. Noise level Shall not Fitting and Accessories: The following fittings shall be provided- a) Two earthing terminals with the earthing symbol bj Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-scaled type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (\\" nominal size thread, 15 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1% nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well las for fors and winding assembly; j) Pressure relief device or explosion or explosion vent above 200 kVA;
281k) One filter valve on the upper side of the tank (for transformers above 200 kVA); I) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating ightning arrestors for HT side-3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover zj. Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. 100KVA.
282Supply. Installation testing and commissioning of indoor type termination kit for 3 C x 35 mm² 11 KV XLPE insulated Aluminum conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable) (Raychem make).
283Supply, Installation testing and commissioning of outdoor type termination kit for 3 C x 35 mm² 11 KV XLPE insulated Aluminum. conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable].[Raychem make].
284POWER AND CONTROL CABLES:Supplying and Laying of XLPE Insulated and PVC Sheathed Power Cable of 11KV/1.1 KV Grade of the following size direct in Ground including excavation,sand Cushioning, Protective Covering and Refilling the Trench as Required. 3 Cx35 mm² 11 KV XLPE insulated Aluminum. conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable).
285Supplying, Installation, Testing and Commissioning of Copper Earthing Electrode of Size 50 x 3000mm with Copper Pipe Outer Dia. 50 mm (++) 5 %).Length 3000 mm,Inner & and Outer Strip Size 25X6mm (Copper), Terminal Hole Two Nos., Terminal Hole Dia. 14 mm, Seal Plate Thickness 4 mm, Base Plate Thickness 4 mm, Inner filling Material - Highly Conductive Super Crystalline Mixture, Outer filling material Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs.
286Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
287Supplying, Installation, Testing and Commissioning of G.l Earthing Electrode of Size 50 x 3000mm with GI Pipe Outer Dia. 58 mm (+-) 5 %,Length 3000 mm,Inner & Outer Gl Strip Size 32X6mm, Terminal Hole Two Nos., Terminal Hole Dia. 14 mm, Seal Plate Thickness 4 mm, Base Plate Thickness 4 mm, Inner filling Material Crystalline Mixture, Outer filling material Highly Conductive Super Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs.
288Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
289FIRE FIGHTING Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to 15 3589/15 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:
29025 mm dia
29180 mm dia
292100 mm dia
293Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal.
294Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
295Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gunmetal.
296Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
297Supplying, installation, testing and commissioning of fire brigade connection of cast iron body with gun metal male & female instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe.
298Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
299Supplying & fixing 63 mm dia short branch pipe with 20mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Gunmetal.
300Providing and fixing Weather proof hose cabinets for yard hydrant fabricated from 16 g MS sheet with full glass door and locking arrangement, suitable to accommodate one hydrant valve, 2 nos. 15m long hose, 1 No branch pipe and one fireman's axe. The cabinet shall be painted with one coat of primer and finished stove enamelled \\"Fire Red\\", \\"Fire Hose written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 mx 0.25 m).
301Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
302Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS: 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 Ipm at 35 m Head.
303Supplying, Installation, Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers, Out Goings, Bus Bars etc. as required as per the Following Description. (IP:55) (Terrace Panel) The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel. Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating. The Panel Builder Shall be CPRI/ERDA/ANY NABL ACCREDITED LAB approved. Refer SLD.
304INCOMERMCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100%.
305Digital Metering Devices.comprising Voltmeter, Ammeter, Selector Switch, Indicating Lamps,C.T Set, Bus Bar(80 Amps) and MCB Strip of suitable size as Required.
306OUTGOINGS MPCB 19-25 A With STD. Magnetic Release.
307Power Contactor 40 A415 Volts, AC-3 Duty.
308Start/Stop Push Button.
309Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia
310Providing, installation, testing and commissioning of non-return valve with temper switch of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : (PN 1.6) 100mm nominal dia.
311Providing, installation, testing and commissioning of stainless steel 16 Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100mm dia.
312Providing and fixing of pressure switch in GI pipe line including connection etc. as required.
313Providing, installation, testing and commissioning of Pressure Guages.
314Fire Detection Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required-2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of ration/communication suitable for 20 Nos.talk back unit-1 set. Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required-1 set.
315Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required-1 No. Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required-1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 60 AH each sealed maintenance free batteries-1 set.
316Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
317Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
318Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
319Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ABS box with break glass in front etc. complete as required.
320Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/PVC conduit as required. 6.1 2 x 1.5 sq. mm.
321Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm.
322Supplying Installation, Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark(IS:15683) suitable for Class A/B/C Type Fires.
323Supplying Installation, Testing and Commissioning of MAP 90 CO2 Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark(IS:15683) suitable for Class A/B/C Type Fires. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58173627
AUTHORITY Government Departments
TENDER VALUE 5.12 Crore
LAST DATE 13-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Modernization / Upgradation Of Govt. Hss Sudhmahadev, District Udh Ur. (Under Ut Capex Budget 2025-26)
Basic Detail
Tender No e-NIT No. 73 of 2026-27 Dated 23-10-2026
Bidding Type Tender
Location
City Udhampur
State Jammu and Kashmir
Key Dates
Publish Date 23 Oct 2026
Submission Date 13 Nov 2026
Open Date 14 Nov 2026
Finance
Tender Value 5.12 Crore
Tender Fee 6000
EMD 10.24 Lakhs
Exemption Not Available
Document List
ac48921d-3b40-41a2-b2c0-e62b893aed75.html
BOQ_1115330.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

ac48921d-3b40-41a2-b2c0-e62b893aed75.html

xls

BOQ_1115330.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender