Tender For Repair / Maintenance Of Internal Electrification , Maintenance Of Acs, Water Cooler, Geyzer Etc And Repair /Maintenance Of External Electric Supply At Cgra Dhar Ur, Dhq-01 Porbandar Under Ge (I) Cg Porbander
Tender Value
29 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
17 days left
EMD
58000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Porbandar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Internal Electrification , Maintenance Of Acs, Water Cooler, Geyzer Etc And Repair /Maintenance Of External Electric Supply At Cgra Dhar Ur, Dhq-01 Porbandar Under Ge (I) Cg Porbander
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' |
| 2 | Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc complete all as spd and directed. |
| 3 | Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces inclduing painting |
| 4 | Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire Excluding modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- |
| 5 | (a) One light/ Bulb Holder /fan/exhaust point / bell point controlled by one, one way switch |
| 6 | (d) One light point controlled by 2, Two way switch |
| 7 | (c) One 5 pin socket outlet 5/6 amps on the same board. |
| 8 | (d) One 5 pin socket oulet 5/6 amps on independent board.. |
| 9 | Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire Excluding modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- |
| 10 | One 16 A socket outlet, independent, with cables 2.5 mm² size complete as specified and directed. |
| 11 | S & F in replacement of modular type 6 A one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal complete as specified and directed. |
| 12 | S & F replacement of modular type 16 A one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal complete as specified and directed . |
| 13 | S & F replacement of modular type 2/3 pin combined shuttered type 6 A socket conforming to IS: 1293- 2005 complete as specified and directed. |
| 14 | S & F replacement of modular type 2/3 pin combined shuttered type 6/16 A socket conforming to IS: 1293- 2005 complete as specified and directed. |
| 15 | S & F replacement of modular type 6 A bell-push conforming to IS: 8884- 1978 with finger proof terminal complete all as specified and directed. |
| 16 | S & F replacement of Bell multi music type 230 Volt complete as specified and directed. |
| 17 | S & F in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984 complete as specified and directed. |
| 18 | S & F in replacement of 6 A, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm complete all as specified and directed. |
| 19 | S & F in replacement of Modular switch 2 way 6A, 1 module complete all as specified and as drirected |
| 20 | Supply and fixing in replacement of Modular Flush box of following size complete all as specified and as directed |
| 21 | 1 or 2 Module Metal flush box complete all as specified. |
| 22 | 3 Module Metal flush box complete all as specified. |
| 23 | 4 Module Metal flush box complete all as specified. |
| 24 | 6 Module Metal flush box complete all as specified. |
| 25 | Supply and fixing in replacment of Modular cover plate with frame of following size complete all as specified and as directed |
| 26 | 1 or 2 Module Modular cover plate with frame of size 85x 85 mm |
| 27 | 3 Module Modular cover plate with frame of size 85x 115 mm |
| 28 | 4 Module Modular cover plate with frame of size 85x 145 MM |
| 29 | 6 Module Modular cover plate with frame of size 132x 135 mm |
| 30 | Supply and fix in replacement following items for maintenance of Internal Electrification, complete all as specified and directed by Engr-in-Charge. |
| 31 | Switch piano, flush type single pole, one way 5 Amp |
| 32 | Socket Outlet 2 in 1, 3 pin, 6A |
| 33 | Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type |
| 34 | Switch piano, flush type single pole, one way 15 Amp |
| 35 | Lamp holder plug for Batten fitting. |
| 36 | Bell push, flush type 5 Amp. |
| 37 | 2.5 mfd Capacitor |
| 38 | Stepped type electronic fan regulator |
| 39 | Top plug 5 Amp complete all as specified and directed. |
| 40 | Top plug 15 Amp complete all as specified and directed. |
| 41 | S&F in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, complete all as specified and directed by Engr-in-Charge. |
| 42 | S&F in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engr-in-Charge. |
| 43 | S&F in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 4 way type, complete all as specified and directed by Engr-in-Charge. |
| 44 | Supply and fixing in replacement of MCB of following size complete all as specified and as directed |
| 45 | MCB 'C' curve 6 to 32Amps single pole |
| 46 | MCB 'C' curve 32Amps double pole / SPN |
| 47 | MCB 'C' curve 40 -63 Amps double pole / SPN |
| 48 | Supply and fixing in replacement of 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed by Engr-in-Charge. |
| 49 | MCB, TP 25 to 63Amps |
| 50 | MCB, TPN/FP 16 to 32Amps |
| 51 | M & L for submain wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size in exsisting conduits / PVC Cassing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, all complete as specified and directed. Make: RR Kabel, Polycab, Havells, Finolex (HR-FR flexible cable) & Precision, Prince, Supreme NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Cassing capping shall be measured as one length. |
| 52 | 2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire |
| 53 | 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire |
| 54 | Supply and fixing in replacement of of casing capping of 25x 12 mm size complete all as specified and as directed. |
| 55 | Supply and fixing in replacement of of casing capping of 32x16 mm size complete all as specified and as directed. |
| 56 | Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engr-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately. |
| 57 | Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge. |
| 58 | Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge. |
| 59 | S & F in repair of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. |
| 60 | S&F wall mounted rechargeable invertor LED batten 20(±10%) watt, 6500K, 4ft, not less than 4 hours backup, efficacy not less than 90 lumen/watt , extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver & lithium battery complete includign making connection complete all as specified and directed. |
| 61 | S&F in replacement of LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires complete all as specified and as directed by Engineer-in-Charge. |
| 62 | S&F in replacement of RGB/Multicolour fountain light LED 9W, IP 68, Aluminium die cast housing with purity lense for spot lightning with glare free light distrubition enhancing accent lighting, including fixing arrangements, S Connector & T Connectors etc complete all as specified and directed. |
| 63 | S&F in replacement of LED wall light 2x 6 Watts (2700K) and including connected with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fitting in position at site all as specified and directed. |
| 64 | S&F in replacement LED Bollard Light Cool White of wattage 11 Watt 6500 K with with integrated mounting base plate and driver complete with housing dark grey RAL 7043 IP 65 protection, Resistant to corrosion and Better optics for uniform distribution including PCC (1:2:4) foundation of suitable size for mounting of light fitting complete all as specified and directed. |
| 65 | Supply and fixing in replacement post top lantern LED type 40 watt 230 volts AC outdoor type(Warm/Cool White) with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 66 | S&F in replacement of LED Pathway not less than 35W, (4000K) Pressure die cast aluminium housing with designed optics provide uniform light distribution to redefine outdoor and enhance architectural design, including fixing arrangements etc complete all as specified and directed. |
| 67 | S&F in replacement of LED decorative Wall mounted fancy Light, Lamp base 1 x E27 type, 7.5 Watts LED Lamp with matt gold finish with borosil glasstype and with high illumination indoor wall light LED, including fixing arrangements etc complete all as specified and directed. |
| 68 | Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ , complete all as specified and directed by Engr-in-Charge. Note- worn out parts shall be measured as separately. |
| 69 | Supply & Fixing spare parts for Geyser |
| 70 | Heating element 1.5 KW with rubber gasket. |
| 71 | Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked. |
| 72 | Hot/Cold water connection pipe 450 mm length. |
| 73 | Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia |
| 74 | Indication lamp red and green suitable for geyser as required Please Enable Macros to View BoQ information |
| 75 | Indication lamp red and green suitable for geyser as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysNov 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender