Tender For Up-Gradation Of Various Sports Complex.Sh: Supply Installation Testing and Commissioning of 10 Mtr, 3 Mtr Octagonal Poles, Submersible Pump Set & Iei Work For Newly Proposed Multi Gym And Various Sports Facilities At Shastri Park .
Tender Overview
Project Description
Tender for Up-Gradation Of Various Sports Complex.Sh: Supply Installation Testing and Commissioning of 10 Mtr, 3 Mtr Octagonal Poles, Submersible Pump Set & Iei Work For Newly Proposed Multi Gym And Various Sports Facilities At Shastri Park .
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a)Group C |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. |
| 3 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 4 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 5 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 6 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as require |
| 7 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 10 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 11 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 12 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way , Double door |
| 13 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a)8 way (4 + 24), Double door |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | a)Single pole |
| 16 | b) Single pole and neutral |
| 17 | Supplying and fixing following rating, TPN, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A |
| 18 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required .a)125 A, 36KA,FPMCCB |
| 19 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 20 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 21 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, remote, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. a)1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 22 | Supplying, installation, Testing & Commissioning of 36 W Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 23 | SSupplying, installation, Testing & Commissioning of 18 W LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast Extruded aluminium Body including trim with Aluminium Reflector. |
| 24 | Supply and fixing of 400 mm wall fan etc complete as required. |
| 25 | Supplying, Erection and Commissioning of HOT Dip galvanized octagonal steel pole of 10 mtr height made out of 3 mm thick sheet having bottom 210 mm A/F & top 90 mm A/F with built in connector control box with flush cover on height of 1000 mm from the bottom of pole, PCD 320 mm, MS base plate of size 320 mm x 320 mm x 20 mm thick with 250 mm strip in octagonal shape, the pole is to be fixed on existing RCC foundation with bolt and nuts making connection, interconnection with thimble/ lugs in the connector box, earthing, making/ numbering of pole etc as required with following accessories with mounted in built in control box. a) 6 mm thick laminated sheet along with 2 nos. 6 Amp, 10KA, SPMCB, 'C' charcteristic on the din channel, 2 no. 63 Amp terminal block suitable for 25 sq.mm Aluminum condr. cable and din channel for MCB's.b) Earth stud weld at suitable height i/c washer, spring washers and nuts.c) Cable support clamps suitable for 2 nos. of 2x 10 sqmm Cable.d) Hot dipped galvanized channel type bracket suitable for mounting upto 4 nos fixture lightings with nut bolt and suitable canopy.e) Drawing of pole and bracket shall be approved from the engineer incharge as per manufacturer before use at site. |
| 26 | Providing and laying in position M 20 (1:2:4) reinforced cement concrete foundation of size 500 mm long x 500 mm wide and 1600 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia 1650mm long (approx.) -8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1800 mm long (approx.)-10 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-24 x 750 mm long (150 mm top threaded portion) GI foundation bolt (EN- 8 grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/ Anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. 26 mm dia holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos DWC pipe for cable entry and exit as required. (Drawing to be approved by Engineer in charge.) |
| 27 | Supplying and drawing following sizes of PVC insulated PVCsheathed/ XLPE copper conductor unarmoured multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable copper lugs connections etc. as reqd. |
| 28 | 3 x 2.5 sq.mm |
| 29 | Supply of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor power cable (As per IS 7098 (Part-1) of 1.1 KV grade i/c connection testing etc.as required. |
| 30 | 2 x 10 sq. mm |
| 31 | 4x16 sq mm |
| 32 | 4x50 sq.mm |
| 33 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 34 | Up to 35 Sq mm |
| 35 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 36 | 63 mm dia (OD-63mm & ID-51 mm nominal) |
| 37 | 90mm dia ( OD-90mm and ID -76 mm nominal ) |
| 38 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 39 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
| 40 | 2 X 10sq. mm (19mm) |
| 41 | Supplying of feeder pillar with floor mounted Light control LT feeder pillar cubical type double door of Suitable size duly compartmentalized and with general arrangement made out of 2mm thick CRCA sheet having hinged gasket cover and screwed knobs with double locking arrangement and rain protection covers 100 mm and supported with of MS angle iron legs and bottom frame of size 40mm x 40mm x 6mm x 1mtr & inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles wherever required, painting, numbering including supply and fixing of following accessories complete etc. as required. (a)63 Amps. Four Pole MCB ('C'-Series), 10kA----1 No.(b)16 Amps. SP MCB ('C'-Series), 10 kA------ 10Nos(c) 30 Ampere 4 way neutral link/connector ------2 Nos. (d) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No (e) Phase Indicating Lamp Set with fuses ----1 Set (f) Danger notice plate -----1 No (g) AI. Bus Bar 100 amp. 4 strip, 300 mm long with sleeve and nut bolts-----1 Set. (h) Ammeter (0-30Amp) 96mm X 96mm square type ----1No.(i) Lifting hook on the top of panel board and lighting arrangement inside the feeder pillar---- 1 No. (j) 32 Amps. TP MCB ('C' Series), 10KA- 2 Nos. |
| 42 | Supplying, Installation, Testing & Commissioning 200W of Flood Light, powder coated pressure die castaluminium body with built in or separate driver asper the requirement with Driverefficiency >85%,Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to52 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) SDCM(Standard Deviation Color Matching) <5,Maximum power consumption should not morethan the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/cexternal connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) DSR.8.15.5 |
| 43 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.DSR 5.2 |
| 44 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 5.15 |
| 45 | Supplying, Erection/ replacement and Commissioning of HOT Dip galvanized octagonal steel pole of 3 mtr height i/c dismantling of existing old /rusted pole,made out of 3 mm thick sheet having bottom 130 mm A/F & top 70 mm A/F with built in connector control box with flush cover on height of 500 mm from the bottom of pole (with anti theft arrangement of cover), MS base plate of size 200 mm x 200 mm x 12 mm thick, the pole is to be fixed on existing RCC foundation with bolt and nuts making connection, interconnection with thimble/ lugs in the connector box, earthing, making/ numbering of pole etc as required with following accessories with mounted in built in control box. a) 6 mm thick laminated sheet along with 2 nos. 5 A to 32 Amp, 10KA, SPMCB, 'C' charcteristic on the din channel, 2 no. 63 Amp terminal block suitable for 16 sq.mm Aluminum condr. cable and din channel for MCB's.b) Earth stud weld at suitable height i/c washer, spring washers and nuts.c) Cable support clamps suitable for 2 nos. of 2x 16 sqmm Cable. d) galvanized steel 1 mtr single arm bracket made out of suitable mm dia pipe with canopy suitable mm as required and suitable for LED fitting etc. as required.e) Drawing of pole shall be approved from the engineer incharge as per manufacturer before use at site. |
| 46 | Providing and laying in position M 20 (1:2:4) reinforced cement concrete foundation of size 400 mm long x 400 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia 1600 mm long (approx.) -8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1800 mm long (approx.)-6 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-16 x 450 mm long (100 mm top threaded portion) GI foundation bolt (EN- 8 grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/ Anchor plate of size 200 mm x 200 mm x 3 mm thick having 4 Nos. suitable mm dia holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos DWC pipe for cable entry and exit as required. (Drawing to be approved by Engineer in charge.) |
| 47 | Supplying, installation, Testing & Commissioning of 72 watt Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 48 | Supplying, Installation, Testing & Commissioning of Submersible Pump set duly coupled with suitable rating 3 phase, 415 volt/220 volt 50Hz, sub. Motor i/c connection testing etc. complete as required. The pump sets shall be suitable for the following duties. ( For 150 mm dia borewell)Head (Meter) Discharge Minimum HP/ Stage Outlet Sizea) 14-123 mtr. 290-60 LPM 5HP/12 stage 50mm |
| 49 | Supplying of following size of double G.I. flanged (ISI marked ) GI pipe 'C' class duly threaded & welded with necessary pipe fittings, bends, elbow etc. complete as reqd. a) 50 mm dia. |
| 50 | Supplying & Fixing of copper conductor flat submersible cable of following size i/c connection testing etc. complete as reqd.A) 3 x 4 sq.mm |
| 51 | SITC of suitable size Outdoor panel made with 2 mm thick CRCA MS sheet with 600 mm 4 Nos MS angle legs i/c Supply and fixing of 3 Phase sub. Pump starter panel for 5 HP sub. pump, 63 Amp 4 pole 16KA MCCB 1 No.& LED Lamp assembly and internal wiring ,connections etc complete as reqd. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender