Home Affairs Boards / Undertakings / PSU Closing in 23 days TDR #58172281

Tender For Construction Of Proposed Model Zila Parisad Office Building, Simdega, Jharkhand.

Issued by Boards / Undertakings / PSU · Simdega, Jharkhand
Tender Value
8.01 Crore
Estimated cost
Bid Submission
19 Nov 2026
23 days left
EMD
16.05 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Simdega → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Construction Of Proposed Model Zila Parisad Office Building, Simdega, Jharkhand.

BOQ

Name of Work:- Construction of Proposed Model Zila Parisad Office Building, Simdega, Jharkhand.
Sl. No. Item Description
1(A) Building
2EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I5.1.1 J.S.R.
3EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) 5.1.7 JSR
4EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
5Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
6Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge. 5.6.1 JSR
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)
8Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)
10Providing and laying in position specified grade of reinforced cement concrete, exluding the cost of centring, shuttering, finishing and reinforcement: all work upto plinth work1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
11Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
12Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts, and struts etc. above plinth level upto floor five floor, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
13Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
14Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
15Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
16Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
17Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
18Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.11JSR
19Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
20Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
21Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
22Reinforcement Bar in R.C.C. 5.5.4,5.5.5,5.5.6 JSR
238mm 20%
2410mm 10%
2512 mm 10%
2616mm 20%
2720mm 20%
2825mm 20%
29Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I..
30Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
31Providing 19 mm thk. Water proof cement plaster (1:3) with clean coarse of sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
32Providing 12 mm Thk. cement plaster(1:6) on walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
33Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
34Providing and applying Thermoflex P-111/Sikka coolcoat or any other Equivalent compound of roof od slab as per following procedure (i) Surface preparation :- Surface of roof slab should be cleaned with wire brush, Dust particle should be removed and surface should be washed with high water pressure and should be get dried. (ii) Primer Coat :- Thermoflex P-111 should be diluted with potable water in 1:1 ratio and this solutation should be applied on cleaned and dry surface with soft brushy roller. (iii) 1st Coat P-111 :- After 3 hours of primer coat first coat of P-111 without any dilutation should be applied with soft brush/roller (iv) when the first coat is partialy and acraylic fibremesh 80GSM mat should be laid and pressed with roller (v) Second / Final Coat :- 2nd coat P-111 (without any dilution) should be applied after 3 hours of 1st coat it should be allowed to dry for 4 hours not be any water contact on surface till 24 hours of final completion of treatment 5.12.10 JSR
35Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than0.08% and conforming to IS: 15622 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 600x6005.6.28 JSR
36Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm5.6.28 JSR
37Providing and laying 25 mm thick kotah stone slab flooring of approved size, texture and colour over 18 mm of thick base of lime morter (1:1:1) (lime putty:Surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.(iv)600x600
38Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including the cost of scaffolding and taxes all complete as per building specification and direction of E/I.(Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification.)Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills& railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. 5.8.41 JSR + 5.8.45 JSR
39Finishing wall with Premium Acrylic Smooth Exterior paint of required shade with Silicon additives on new works in two or more coats applied @ 1.43 Ltrs/10 Sqm. Over and including base coat of water proofing cement paint applied @ 2.2 Kgs/10Sqm. All complete job.Providing and applying POP putty of 2 mm thickness over plastered surface to prepare the surface even and smooth all complete as per building specification and direction of E/l.13.47.1+13.26 DSR
40Providing two coats of plastic emulsion of approved shade and make over a coat of of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying puuty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqmProviding and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
41Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessaryfilling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :21.1.1.1DSR
42Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side 21.2.1 DSR
43Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as perthe architectural drawings and the directions of engineer-in-charge . (Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
44Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.)
45Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)Per sq.m @ 42 kg/SQM5.5.12 JSR
46Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand . 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth - do - do - all complete job as per direction of E/I.
47Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL antitermite treatment (excluding the cost of chemical emulsion) :Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:Pre treatment
48Providing 250 mm wide brick drain in cement mortar (1.6) with av. 150mm, clear depth and 250mm apron including cost of earthwork involved with 75 mm cement concrete (1:4:3) over one brick designation 75A, flat solling in proper grade and slope at the base, the drain duly plastered in CM (1:3) with punning over exposed surface all complete as per building specification and direction of E/I5.10.33 JSR
49Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
50Wall lining butch work upto 10m height with Dholpur stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width, including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75x75 mm and by providing layer of 75 mm thick strips i/c 12 mm thick bed of cement mortar 1:3 (1 Cement : 3 coarse sand) i/c ruled pointing in cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in-charge.8.17 DSR
511. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-33010 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml25.2 DSR
52Carriage of materials from different surface or department stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
53Cement
54Chips
55Bricks
56Steel
57ELECTRIFICATION WORK
58Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.3.3 JSR E&M Gr-C
59Supply and Fixing Light Plug Point with Modular Type Accessories:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 1.3.1 JSR E&M
60Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. 1.3.2 JSR E&M
61Supply & fixing 20A SPN MCB Industrial Socket Outlet: Supply and fixing of 20A, 240V, SPN insustrial type socket outlet with 2 poles and earth, metal enclosed plug top along with 20 amps 'C' series, SP MCCB, in sheet steel enclosure, on surface or in recess with chained metal cover for socket out let and complete with connections, testing and commissioning etc as required. 2.18 JSR E&M
62Power Plug Wiring in PVC conduit (2x4 sq. mm): Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1.5 JSR E&M
63Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. 1.7 JSR E&M
642x1.5 Sqmm + 1x1.5 sqmm earth wire 1.7.1
652x2.5 Sqmm + 1x2.5 sq mm earth wire 1.7.2
662x4 Sqmm + 1x4 sq mm earth wire 1.7.3
674x6 Sq.mm + 2x6 Sq.mm earth wire. 1.7.9
684x10 Sq.mm + 2x6 Sq.mm earth wire. 1.7.10
69S/F TP MCB DB:- Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). (All TP MCB DB shall be as per IS:8623) 2.9 JSR E&M
704 Ways (4+12 ways) double door 2.9.4
716 Ways (4+18 ways) double door 2.9.5
728 Ways (4+24 ways) double door 2.9.6
73S/F 'C' series MCB:- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12 JSR E&M
746/32A Single Pole 2.12.1
756/32A TP MCB 2.12.8
7650/63amp TPN MCB 2.12.10
77S/F Ceiling Rose: Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 1.33 JSR E&M
78S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required. 1.34 JSR E&M
79Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1.27 JSR E&M
804/5 Module (78mmX78mmX50mm) 1.27.2
816 Module (200mmX75mm) 1.27.3
82ITC fluorescent fitting directly on surface :- installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, directly on ceiling / wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. 1.41 JSR E&M
83ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required. 1.44 JSR E&M
84S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. 1.25 JSR E&M
85Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required. 1.48 JSR E&M
86Upto 450 mm sweep
87Telephone Wiring in Existing Conduit: Supplying and drawing, following pair, 0.5 sq.mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed steel / PVC conduit as required. 1.16 .2 JSR E&M
881.16.2
89S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required. 1.24 JSR E&M
90Telephone socket outlet 1.24.6
91Copper Earth Plate Electrode:Earthing with copper plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt ) as required. 3.6 JSR E&M
92Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required. 3.7 JSR E&M
93Providing and fixing 25mm x 5mm copper earth strip in pipe:Providing and fixing 25mm x 5mm copper earth strip in 40mm dia. G.I. pipe from earth electrode, as required 3.11 JSR E&M
94LIGHT FITTINGS
95LED Batten 20/22W 14.95 Overhead & Profit charge M-854 JSR E&M Pg no 48
969/10 W Led Bulb 14.95 Overhead & Profit charge M-855 JSR E&M Pg no 48
97Supply of 300mm dia 1400 rpm,230V AC Exhaust Fan (metal) exhaust fan 9\\" in with double ball bearing existing opening and fittinigs as required. 14.95 Overhead & Profit charge M-774 JSR E&M Pg no 46
98Supply installation, testing and commissioning of following size ceiling fan 3 blades Confirming to IS:374:2019 including the down rods of standard length (upto 30 cm) with 1.5 sqmm FR PVC insulated, copper wire suitable for 230V 50 Hz, single phase supply etc. complete as required.1400 mm 56\\" 9.4.2 JSR E&M
99Provioding and laying 1.1 KV grade aluminium armoured cable as per IS 1554 (Part I) heavy duty all cost complete including cost of brass compression gland, cable jointing and end termination as per specification and direction f E/I. Basic rate +40% for laying & C.P.
100S/F3.5 core, 95 sq.mm14.95 Overhead & Profit charge M330 JSR E&Mpg no 41
101S/F3.5 core, 50 sq.mm14.95 Overhead & Profit charge M328 JSR E&Mpg no 41
102Silent Type DG Set of Capacity 87.5 KVA with AMI Panel IS/IEC -600034 1IS: 1460 IS: 13018 M905 Pg no 55+14.95%
103PLUMBING SANITARY WORK AS PER SOR 2021
104Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \\"p\\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With \\"P\\" trap (a)12.5 lit. low level P.V.C. cistern
105Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry hindustan or any other ISS approved make with 100mm HCI p trap 15 litres CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings CI or C C bracket 32mm alkethene / PVC telescopic flush pipe about 2m long with one brass coupling and clamps GI chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm CI body brass spindle stop cock of weight not less than 50 grames 15mm PVC connection pipe 450mm long and coat of red oxide primer etc all complete as per specification and direction of E/I.
106(B) 580 mm long
107with 12.5 litre low level PVC cistern
108supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or any other I.S.S approved make supported on painted C.I OR R.S bracket 32mm C.I brass waste 15mm dia C.I body brass spindle stop cock of approved quality of weight not less than 350 grames, 32mm PVC wate pipe 750mm long with brass coupling with one end and making plumber joints etc.all complete as per specification and direction of E/I.
109Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
110Supplying, fitting and fixing gun metal full way valve of approved quality all complete as per specifcation and direction of E/I.
11120mm dia.
11225mm dia.
11332mm dia
11440mm dia
115Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/I. … 15mm dia.
116Cutting chajjas or concrete for laying PVC Pipe and restoring the same with R.C.C. (1:2:4) brick work in cement Mortar (1:4) and cement plaster 1:4 as per specifiction and direction of E/I
117Making holes in walls for PVC Pipe and restoring the same atfer pipe Laying (b) 250mm thick wall
118Cutting drain width wise above GL for laying PVC pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in C.M. (1:4) with neat cement punning as per specifciation and direction of E/I. (PVC 110mm dia)
119Making holes in wall for laying PVC pipes and restoring the same all cost complete (PVC pipe 250mm dia)
120Supplying all tolls and labour and cutting chajja cornice for laying PVC pipes and making good the same as per specification and direction of E/I.
121Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 14.95% for labour and Contractors profit)
122Pillar cock Long neck (Basic rate Rs.756.60 + 30% for C.P. & laying charge)
123Bib cock - long thread (Basic rate Rs.701.10 + 30% for C.P. & laying charge)
124Angular Stop cock L.T.(Basic rate Rs.572.85 + 30% for C.P. & laying charge)
125Glass shelf (Basic rate Rs.641.25 + 30% for C.P. & laying charge
126Flush valve complete with 32mm size control cock & flange (Basic rate Rs.3283.00 + 30% for C.P. & laying charge
12732mm dia. PVC waste pipe 750mm long with cushion (Basic rate Rs.52.00 + 30% for C.P. & laying charge
12815mm C.P. nipple with coupling(As per JSR 15 basic rate Rs.72.70 + 30% C.P. & laying charge)
129Providing Solvent cement (as per JSR 15 basic item - 240.00 + 30% C.P & laying charge
130Supplying, fitting and fixing Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. 600 X 450mm
131Supplying, fitting and fixing C.P. brass soap dish container medium quality with screw and hinges etc.
132Providing and fixing 15mm dia and 45cm long PVC connection pipe with heavy quality brass coupling at both ends etc all complete as per specification and direction of engineer in charge
133Supplying, materials and labour for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I
134Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931, 15mm dia nominal bore of approved brand C.P. fittings
135Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quaility and colour 15mm nominal bore weighing not less than 32gms.
136Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc.
13720mm nominal bore
13825mm nominal bore
13932mm nominal bore
140External work - 40mm nominal bore
141Providing & fixing on wall face unplasticised - Rigid P.V.C. pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
142Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
143Single Tee with door
144110x110x110 ,mm
145Bend 87.5 degree
146110 mm bend
147Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
148PCC ROAD
149EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I5.1.1 J.S.R.
150EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) 5.1.7 JSR
151Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) 5.1.10 JSR
152Supplying and laying (properly as per design and drawing) rip-rap with good quality of boulders duly packed including the cost of material, royalty all taxes etc. but excluding the cost of carriage, all complete as per specification (6.8) Common JSR
153Providing and fixing 20 mm thick compressible fiber board in expansion joints complete as per drawing and technical specification of E/I14.18(ii) RCD JSR
154Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)5.3.1.2 JSR
155Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17 JSR
156Carriage of materials from different surface or department stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
157Cement
158Chips
159Boulder
160C) PAVER
161Description of Items
162EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I5.1.1 J.S.R.
163Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) 5.1.10 JSR
164Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)5.3.1.2 JSR
165Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17 JSR
166Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction ofEngineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.16.91.2
167Carriage of materials from different surface or department stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
168Cement
169Chips
170Paver
171BOUNDARY WALL
172EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I5.1.1 J.S.R.
173Extra for earthwork in hard soil as per specification and direction of E/l (vide classification of soil item-B)5.1.2 JSR60% Quantity vide item no. 1
174EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) 5.1.7 JSR
175Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) 5.1.10 JSR
176Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge. 5.6.1 JSR
177Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)5.3.1.2 JSR
178Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17 JSR
179Providing and laying in position specified grade of reinforced cement concrete, exluding the cost of centring, shuttering, finishing and reinforcement: all work upto plinth work1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.9JSR
180Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17 JSR
181Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts, and struts etc. above plinth level upto floor five floor, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.10 JSR
182Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17.6 JSR
183Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.11JSR
184Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform5.3.17.3 JSR
185Reinforcement Bar in R.C.C. 5.5.4,5.5.5,5.5.6 JSR
1868mm 20%
18710mm 10%
18812 mm 10%
18916mm 20%
19020mm 20%
19125mm 20%
192Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.. 5.2.3 JSR
193Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge 5.2.11 JSR
194Providing 19 mm thk. Water proof cement plaster (1:3) with clean coarse of sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I. 5.7.15 JSR
195Finishing wall with Premium Acrylic Smooth Exterior paint of required shade with Silicon additives on new works in two or more coats applied @ 1.43 Ltrs/10 Sqm. Over and including base coat of water proofing cement paint applied @ 2.2 Kgs/10Sqm. All complete job.Providing and applying POP putty of 2 mm thickness over plastered surface to prepare the surface even and smooth all complete as per building specification and direction of E/l.13.47.1+13.26 DSR
196Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)Per sq.m @ 30 kg/SQM5.5.12 JSR
197Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including the cost of scaffolding and taxes all complete as per building specification and direction of E/I.(Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification.)Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills& railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. 5.8.41 JSR + 5.8.45 JSR
198Carriage of materials from different surface or department stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
199Cement
200Chips
201Bricks
202Steel
203PLANTATION
204Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.2.12 DSR
205Grassing with selection No. 1/ Doob grass including watering andmaintenance of the lawn for 30 days or more till the grass forms a thicklawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).2.10.1 DSR
206a) Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum pr 100 meters and supplying and planting hedge plants at 30 cm apart)JSR Road 11.7
207Maintainance of hedge for one year JSR Road 11.7 B
208Hedge along paved area
209Trenching in ordinary soil up to a depth of 60 cm including removal andstacking of serviceable materials and then disposing of surplus soil, byspreading and neatly levelling within a lead of 50 m and making up thetrenched area to proper levels by filling with earth or earth mixed withsludge or / and manure before and after flooding trench with water (excludingcost of imported earth, sludge or manure). DSR HOR 2.1
210Supplying and stacking of good earth at site including royalty and carriageupto 5 km lead complete (earth measured in stacks will be reduced by20% for payment). DSR HOR 2.2
211Supplying and stacking at site dump manure from approved source,including carriage upto 5 km lead complete (manure measured in stackswill be reduced by 8% for payment)DSR HOR 2.4
212Fine dressing of the groundDSR HOR 2.7
213Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately)DSR HOR 2.8
214Mixing earth and sludge or manure in the required proportion specified ordirected by the Officer-in-charge DSR HOR 2.9
215Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. HOR DSR 2.31
216Supplying and spreading of sand in lawn area, including watering and dressing complete.DSR HOR 2.27
217Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same and maintenance for 30 days or more till the grass establish properly, as per direction of the officer in charge.DSR HOR 2.34
218Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, edge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide,Pesticide, lawn mover and brush cutter with fuel & other T & P material/articles shall be provided by the department.) DSR HOR 2.39.5
219Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal ofunserveiceable material’s as per direction of officer in charge (excludingcast of plant & water)DSR HOR 2.57.1+2.57.2
220Tree Plants
221Shrub Plants
222Providing and fixing of Tuflex Garden fencing Hexagonal net/or equivalentof green colour having contents ( Weight grams/sqm. 510 (+/- 8%)) inwidth of 60 cm. with bamboo of 90 cm. length. The bamboo should bepainted with green colour paint of approved brand and manufacture (two ormore coats) and fixed 30 cm. below ground level and 60 cm. above groundlevel at a distance of 1.50 mtrs. The net and bamboo should be binded with 2 mm. G.I. Wire at three places properly as per direction of Engineer-in-charge. DSR HOR 2.58
223Providing and stacking of Bottle palm of ht. 210-240 cm bottom girth 30-35cm well developed in big HDPE bags. DSR HOR 7.11
224Providing and displaying of Areca Palm having ht. 90 cm to 1.20 m with4 to 5 suckers, well developed, fresh and healthy with lush green foliagein 25 cm size of Earthen pot/Plastic pot & as per direction of theofficer-in-charge. DSR HOR 3.18
225Providing and displaying of Schefflera high colour having ht. 25 cm to 30cm, well developed with fresh & healthy foliage in 25 cm size of Earthenpot/Plastic pot & as per direction of the officer-in-charge. DSR HOR 3.85
226Providing and Displaying Allyssum white in full bloom well developed fresh& healthy Plant in 20 cm Earthen Pot/Plastic Pot and as per directionof the officer-in-charge. DSR HOR 4.1
227Providing and Displaying Petunia hybrid different variety in different colourwell developed with fresh and healthy foliage in full bloom in 25 cm EarthenPot/Plastic Pot as per direction of the officer-in-charge. JSR HOR 4.50
228Providing and Displaying Dahlia double kenya variety in different colourwell developed with 3 to 4 flowers in half bloom, good foliage stacked withGreen painted Bamboo sticks, 45 to 60 cm height in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. DSR HOR 4.24
229Providing and Displaying Dianthus dwarf in different colour fresh & healthybloom in 20 cm Earthen Pot/Plastic Pot and as per direction of theofficer-in-charge. DSR HOR 4.27
230Providing and Displaying Marigold jaffri orange/yellow/Russet colour welldeveloped with fresh & healthy foliage with 40 to 50 flowers in bloomspecimen plant 60 to 75 cm ht in 25 cm Earthen Pot/Plastic Pot and asper direction of the officer-in-charge. DSR HOR 4.37
231Providing and Displaying Mimulus multi branching bushy plant in differentcolour well developed fresh & healthy in full bloom in 20 cm Earthen Pot in20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. DSR HOR 4.42
232Providing and Displaying Nasturtium in different colour well developed withfresh & healthy foliage with full bloom in 20 cm Earthen Pot/Plastic Pot asper direction of the officer-in-charge. DSR HOR 4.44
233Providing and Displaying Verbena in different colour having 30 to 45 cm ht.,well developed with fresh & healthy foliage in bloom condition in 25 cmEarthen Pot/Plastic Pot and as per direction of the officer-in-charge DSR HOR 4.70
234Providing and stacking of Cassia biflora of height 60-75 cm. with 4-5branches in poly bags of size 25 cm as per direction of the officer-in charge.DSR HOR 8.9
235Providing and stacking of plant Mogra of height 25 to 30 cm., 2 to 3 branchin earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per directionof the officer-in-charge. DSR HOR 4.88
236Providing and stacking of Jasmine grandiflorum (chameli) of height 30 cmto 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. . DSR HOR 9.8
237Providing and Displaying Budded Rose (H.T. variety) 3 to 4 healthy branch30 cm and above ht. well developed with one and above flower plant in20 cm Earthen Pot, as per direction of the officer-in-charge. JSR HOR 4.91
238Providing and stacking of Cassia siamea of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. DSR HOR 7.17
239Providing and stacking of Cassia siamea of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. DSR HOR 7.18
240Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm.in big poly bags of size 25 cm as per direction of the officer-in-charge.v DSR HOR 7.24
241Providing and stacking of Ficus benjamina (green) of height 150-165 cm.,bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. DSR HOR 7.27
242Providing and stacking of Ficus bengalensis krishna of height 75-90 cm.,multibranched in earthen pots of size 30 cm as per direction of theofficer-in-charge DSR HOR 7.30
243Providing and stacking of Grevillea robusta (Silver Oak) of height 150-165cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR HOR 7.45
244Providing and stacking of Cassia biflora of height 60-75 cm. with 4-5branches in poly bags of size 25 cm as per direction of the officer-in charge.DSR HOR 7.74
245Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR HOR 7.80
246Providing and stacking of Schleichera trijuga (Kusum) of height 150-165cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR HOR 7.81
247GUARD ROOM
248EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I5.1.1 J.S.R.
249EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) 5.1.7 JSR
250EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) 5.1.8 JSR
251Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) 5.1.10 JSR
252Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge. 5.6.1 JSR
253Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)5.3.1.2 JSR
254Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17 JSR
255Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)5.3.1.2 JSR
256Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17 JSR
257Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts, and struts etc. above plinth level upto floor five floor, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.10JSR
258Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17 JSR
259Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts, and struts etc. above plinth level upto floor five floor, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.10 JSR
260Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17.6 JSR
261Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.11JSR
262Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform5.3.17.3 JSR
263Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.11JSR
264Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform5.3.17.3 JSR
265Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.11JSR
266Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform5.3.17.3 JSR
267Reinforcement Bar in R.C.C. 5.5.4,5.5.5 JSR
2688mm 30%
26910mm 20%
27012 mm 20%
27116mm 30%
272BRICK WORK
273Providing designation 75-B brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.. 5.2.6 JSR
274Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge 5.2.14 JSR
275Providing 19 mm thk. Water proof cement plaster (1:3) with clean coarse of sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I. 5.7.15 JSR
276Providing 12 mm Thk. cement plaster(1:6) on walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I5.7.3 JSR
277Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I 5.7.6 JSR
278Providing and applying Thermoflex P-111/Sikka coolcoat or any other Equivalent compound of roof od slab as per following procedure (i) Surface preparation :- Surface of roof slab should be cleaned with wire brush, Dust particle should be removed and surface should be washed with high water pressure and should be get dried. (ii) Primer Coat :- Thermoflex P-111 should be diluted with potable water in 1:1 ratio and this solutation should be applied on cleaned and dry surface with soft brushy roller. (iii) 1st Coat P-111 :- After 3 hours of primer coat first coat of P-111 without any dilutation should be applied with soft brush/roller (iv) when the first coat is partialy and acraylic fibremesh 80GSM mat should be laid and pressed with roller (v) Second / Final Coat :- 2nd coat P-111 (without any dilution) should be applied after 3 hours of 1st coat it should be allowed to dry for 4 hours not be any water contact on surface till 24 hours of final completion of treatment 5.12.10 JSR
279Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1000x1000 mm5.6.28 JSR
280Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1000x1000 mm5.6.28 JSR
281Supplying, fitting & fixing 20 GAUGE GCI sheet gate fitting on MS angle frame of size 60x60x6mm including cost of fabrication and necessary locking arrangement with haskal and dommy standard make with oxidised iron fittings such as hinges, tower bolts , handle,cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I 5.5.29
282Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including the cost of scaffolding and taxes all complete as per building specification and direction of E/I.(Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification.)Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills& railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. 5.8.41 JSR + 5.8.45 JSR
283Finishing wall with Premium Acrylic Smooth Exterior paint of required shade with Silicon additives on new works in two or more coats applied @ 1.43 Ltrs/10 Sqm. Over and including base coat of water proofing cement paint applied @ 2.2 Kgs/10Sqm. All complete job.Providing and applying POP putty of 2 mm thickness over plastered surface to prepare the surface even and smooth all complete as per building specification and direction of E/l.13.47.1+13.26 DSR
284Providing two coats of plastic emulsion of approved shade and make over a coat of of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying puuty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqmProviding and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete 5.8.21JSR + 13.26 DSR
285Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.) 5.5.13 JSR
286Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand . 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth - do - do - all complete job as per direction of E/I.4.17 DSR
287Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentrationAlong the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 2.35+2.35.2 DSR
288Carriage of materials from different surface or department stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
289Cement
290Chips
291Bricks
292Steel
293MAIN GATE
294EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I5.1.1 J.S.R.
295EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) 5.1.7 JSR
296Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) 5.1.10 JSR
297Providing designation 75B brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.. 5.2.14 JSR
298Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:3:6(1 cement : 3 coarse sand (Zone III) : 6 graded stone aggregate 20 mm nominal size)5.3.1.4 JSR
299Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17.1 JSR
300Providing and laying in position specified grade of reinforced cement concrete, exluding the cost of centring, shuttering, finishing and reinforcement: all work upto plinth work1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.9.1JSR
301Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17 JSR
302Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts, and struts etc. above plinth level upto floor five floor, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.10 JSR
303Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete5.3.17.6 JSR
304Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts, and struts etc. above plinth level upto floor five floor, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)5.3.10 JSR
305Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform5.3.17.3 JSR
306Reinforcement Bar in R.C.C. 5.5.4, 5.5.5, 5.5.6 JSR
3078mm 20%
30810mm 15%
30912 mm 15%
31016mm 30%
31120mm 20%
312Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge 5.2.11 JSR
313Providing and laying Polished Granite stone flooring in required design andpatterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
314Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including the cost of scaffolding and taxes all complete as per building specification and direction of E/I.(Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification.)Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills& railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
315Supply, fitting and fixing M.S. grill gate made of 20x6mm M.S. flats or 16mm.M.S. Square bars fitted on 25x25x6mm. M.S. square bars fitted on 25x25x6mm M.S. angle frame (where steel is not supplied by the deptt.)
316Cement
317Chips
318Bricks
319Steel
320100 USER SEPTIC TANKS
321Earthwork in excavation in foundation trenches all
322Providing clean coarse sand filling in foundation all
323Providing brick flat soling all complete
324Providing P.C.C (1:4:8) in subbase all complete
325Providing 75B Brick work in foundation all complete
326Providing R.C.C (1:1.5:3) in lintel all cost complete
327Add Centering Shutteing
328Providing 125mm thick brick work in partition all
3292X1.20X1.65 :3.96
330Providing 12mm. Cement plaster all cost complete
331Providing 1.5mm cement punning all cost complete
332Providing R.C.C (1:1.5:3) in slab all cost complete
333Add Centering Shutteing
334Providig tor steel reinforcement for all RCC work all
335Supplyig C.I Cover 600X450MM (Wt. 25 Kg) - 4 nos(JSR basic rate 1400 + 14.95% ) Pge 42 it. No. 26(b)
336CARRIAGE OF MATERIALS
337Cement
338Chips
339Bricks
340STEEL
341Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
342DEEP BORING (200 X 150 mm dia) & INSTALLATION OF 1 H.P. SUBMERSIBLE PUMP SET
343Cost of drilling 200 mm X 165 mm X 125 mtr deep borewell in all kind of soil and rock in rural area for installation of pump set with hydraulic DTH rig machine on complete including all material tools drilling rig air compressor reand equipment will as fuel lubricant sand cost of transportation of rig machine and weather vehicle of to site
344(a) From 0.00m to 50.00m below to g.l
345(b) From 51.00 m to 125.00 m
346(b) From above 125 m
347Suplying asembling lowering and fixing in vertical position in borewell unplastisized PVC medium well casing (CM) pipe of required dia confirming to IS: 12818 including required hire and labour charges fitting and acesories etc. all complete for all depth as per direction of engineer - in - charge 200 mm nominal size dia
348Development of tubewll in accordance with IS: 2800 (part1) and IS: 11189, to stables maximum rate of usable water yield without sand content (beyond permissible limits) with required capacity air compressors running the compressor for required time till well is fully developed measuring yield of well by \\"V\\" notes method for another approved measuring method static level and drow down etc. by step drow down method collecting water samples and getting testing approved labarotary i/c disinfection of tubewell all complete including hire and labour charges of air compressor and tool and assecories etc. all as per requirement and direction of engineer - in - charge
349Providing and fixing suitable side threaded mild steel cap all support weilded plate to the top of borewell housing / casting pipe removable as per requirement all completed for borewell of 200 mm dia
350Providing and fixing MS clamp of require dia to the top of casing / housing pipe of tubewell as per IS: 2800 (part 1) including necessary bolt and nuts of required size complete 200 mm clamp
351Supplying 100 mm dia submersible pump sets confirming to 8034 and motor confirming t0 IS: 9283 pump shall be suitable for various delivery had and motor suitable for working on 415+10, 3 HP, 50 ZH, AC supply with cable guard thrust carbon/fibre bearing to withstand entire hydraulic thrust water proof winding to be provide the pump set be suitable for direct coupling pump shall have suitable outylet as per manufacture design anti thrust streamlined non return valve shall be provided withpump 3 mtr submersible copper conductor cable in single/double run shall be provide each pump submersible pump 100 mm dia (with polypropylene/noryl impeller) upto 20 stage 2 HP
352Supply fitting and fixing 3 crore 4 sqmm flat copper submersible Finolex/Havels make including all taxes, royalty etc all complete job as per direction of E/I
353Supply fitting and fixing lowering 50 mm dia G.L collumn pipe - do - all complete job as per direction of E/I
354ESTIMATION OF QUANTITY FOR LIGHTNING CONDUCTORS.
355Providing and fixing of lightning conductor finial, made of 25mm dia, 300mm long GI tube, having single prong at top, with 85mm dia 6mm thick GI base plate including holes etc. complete as required.
356Providing and fixing GI tape 20mm x3mm thick on parapet or surface of wall for lightning conductors as required ( for horizontal run)
357Providing and fixing GI tape 20mm x3mm thick on parapet or surface of wall for lightning conductorsas required ( for verticall run)
358Providing and fixing testing joints, made of 20mm x3mm thick GI strip, 125mm long with 4 Nos of GIbolts nuts check nuts and spring washer complete as required.
359GI Earth Plate Electrode : Earthing with GI plate600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. 2.7 metre long (but without charcoal or coke and salt complete) as required.
360Salt /charcoal for plate earth electrode: Extra for using charcoal and salt for G.I. copper plate earth electrode as required
361RAIN WATER HARVESTING.
362Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.
363Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).
364Providing PCC M-75 with nominal mix of (1:3:6) in filling in plinth & sunken slab of toilet with approved quality of stone metal grade III (53 to 22.4mm size) and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixture, placing in position, vibration, striking, curing taxes and royalty all complete as per building specification & direction of E/I.
365Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
366Providing R.C.C. M - 200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/l.
367Reinforcement for RCC work including straightening, cutting, bending, placing in position and bonding all complete.
368TMTC-500 8mm dia
369Providing designation 75B brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
370Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I (Cost of Cico will be paid separately)
371Supplying, assembling, lowering and fixing in vertical position borewell unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge
372Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
373Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
374Supplying, materials and labour for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
375P/L NP2 class R.C.C pipes with collars joint with stiff mixture of cement mortar in the proportion of (1:2)
376250 mm dia. R.C.C pipe
377Supplying and fixing C.I cover without frame for manholes: 560 mm diameter C.I cover (medium duty) the weight of the cover to be not less than 58 kg
378Carriage of material
379Cement
380STEEL
381Chips
382Bricks
383J) KITCHEN
384EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/IExtra for hard soil
385EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
386EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
387Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
388Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge.
389Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)
390Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
391Providing and laying in position specified grade of reinforced cement concrete, exluding the cost of centring, shuttering, finishing and reinforcement: all work upto plinth work1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
392Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
393Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts, and struts etc. above plinth level upto floor five floor, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
394Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
395Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
396Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
397Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
398Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
399Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
400Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
401Reinforcement Bar in R.C.C.
4028mm 20%
40310mm 15%
40412 mm 15%
40516mm 30%
40620mm 20%
407Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I..
408Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
409Providing 19 mm thk. Water proof cement plaster (1:3) with clean coarse of sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
410Providing 12 mm Thk. cement plaster(1:6) on walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
411Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than0.08% and conforming to IS: 15622 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 600x600
412Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
413Providing and laying 25 mm thick kotah stone slab flooring of approved size, texture and colour over 18 mm of thick base of lime morter (1:1:1) (lime putty:Surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.(iv)600x600
414Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including the cost of scaffolding and taxes all complete as per building specification and direction of E/I.(Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification.)Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills& railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
415Finishing wall with Premium Acrylic Smooth Exterior paint of required shade with Silicon additives on new works in two or more coats applied @ 1.43 Ltrs/10 Sqm. Over and including base coat of water proofing cement paint applied @ 2.2 Kgs/10Sqm. All complete job.Providing and applying POP putty of 2 mm thickness over plastered surface to prepare the surface even and smooth all complete as per building specification and direction of E/l.
416Providing two coats of plastic emulsion of approved shade and make over a coat of of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying puuty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqmProviding and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
417Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessaryfilling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
418Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
419Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as perthe architectural drawings and the directions of engineer-in-charge . (Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
420Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)Per sq.m @ 42 kg
421Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand . 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth - do - do - all complete job as per direction of E/I.
422Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL antitermite treatment (excluding the cost of chemical emulsion) :Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:Pre treatment
423Providing 250 mm wide brick drain in cement mortar (1.6) with av. 150mm, clear depth and 250mm apron including cost of earthwork involved with 75 mm cement concrete (1:4:3) over one brick designation 75A, flat solling in proper grade and slope at the base, the drain duly plastered in CM (1:3) with punning over exposed surface all complete as per building specification and direction of E/I
424Carriage of materials from different surface or department stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
425Cement
426Chips
427Bricks
428Steel
429Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
430Supply and Fixing Light Plug Point with Modular Type Accessories:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
431Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
432Supply & fixing 20A SPN MCB Industrial Socket Outlet: Supply and fixing of 20A, 240V, SPN insustrial type socket outlet with 2 poles and earth, metal enclosed plug top along with 20 amps 'C' series, SP MCCB, in sheet steel enclosure, on surface or in recess with chained metal cover for socket out let and complete with connections, testing and commissioning etc as required.
433Power Plug Wiring in PVC conduit (2x4 sq. mm): Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
434Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
4352x1.5 Sqmm + 1x1.5 sqmm earth wire
4362x2.5 Sqmm + 1x2.5 sq mm earth wire
4372x4 Sqmm + 1x4 sq mm earth wire
4384x6 Sq.mm + 2x6 Sq.mm earth wire.
4394x10 Sq.mm + 2x6 Sq.mm earth wire.
440S/F TP MCB DB:- Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). (All TP MCB DB shall be as per IS:8623)
4414 Ways (4+12 ways) double door
4426 Ways (4+18 ways) double door
4438 Ways (4+24 ways) double door
444S/F 'C' series MCB:- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
4456/32A Single Pole
4466/32A TP MCB
44750/63amp TPN MCB
448S/F Ceiling Rose: Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
449S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required.
450Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
4514/5 Module (78mmX78mmX50mm)
4526 Module (200mmX75mm)
453ITC fluorescent fitting directly on surface :- installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, directly on ceiling / wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
454ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required.
455S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
456Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required.
457Upto 450 mm sweep
458Telephone Wiring in Existing Conduit: Supplying and drawing, following pair, 0.5 sq.mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed steel / PVC conduit as required.
4592 pair
460S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required.
461Telephone socket outlet
462Copper Earth Plate Electrode:Earthing with copper plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt ) as required.
463Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required.
464Providing and fixing 25mm x 5mm copper earth strip in pipe:Providing and fixing 25mm x 5mm copper earth strip in 40mm dia. G.I. pipe from earth electrode, as required
465LIGHT FITTINGS
466LED Batten 20/22W14.95 Overhead & Profit charge
4679/10 W Led Bulb14.95 Overhead & Profit charge
468Supply of 300mm dia 1400 rpm,230V AC Exhaust Fan (metal) exhaust fan 9\\" in with double ball bearing existing opening and fittinigs as required. 14.95 Overhead & Profit charge
469Supply installation, testing and commissioning of following size ceiling fan 3 blades Confirming to IS:374:2019 including the down rods of standard length (upto 30 cm) with 1.5 sqmm FR PVC insulated, copper wire suitable for 230V 50 Hz, single phase supply etc. complete as required.1400 mm 56\\"
470Provioding and laying 1.1 KV grade aluminium armoured cable as per IS 1554 (Part I) heavy duty all cost complete including cost of brass compression gland, cable jointing and end termination as per specification and direction f E/I.
471S/F3.5 core, 95 sq.mm14.95 Overhead & Profit charge
472S/F3.5 core, 50 sq.mm14.95 Overhead & Profit charge
473PLUMBING SANITARY WORK AS PER SOR 2021
474Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \\"p\\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With \\"P\\" trap (a)12.5 lit. low level P.V.C. cistern
475Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry hindustan or any other ISS approved make with 100mm HCI p trap 15 litres CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings CI or C C bracket 32mm alkethene / PVC telescopic flush pipe about 2m long with one brass coupling and clamps GI chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm CI body brass spindle stop cock of weight not less than 50 grames 15mm PVC connection pipe 450mm long and coat of red oxide primer etc all complete as per specification and direction of E/I.
476(B) 580 mm long
477with 12.5 litre low level PVC cistern
478supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or any other I.S.S approved make supported on painted C.I OR R.S bracket 32mm C.I brass waste 15mm dia C.I body brass spindle stop cock of approved quality of weight not less than 350 grames, 32mm PVC wate pipe 750mm long with brass coupling with one end and making plumber joints etc.all complete as per specification and direction of E/I.
479Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
480Supplying, fitting and fixing gun metal full way valve of approved quality all complete as per specifcation and direction of E/I.
48120mm dia.
48225mm dia.
48332mm dia
48440mm dia
485Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/I. … 15mm dia.
486Cutting chajjas or concrete for laying PVC Pipe and restoring the same with R.C.C. (1:2:4) brick work in cement Mortar (1:4) and cement plaster 1:4 as per specifiction and direction of E/I
487Making holes in walls for PVC Pipe and restoring the same atfer pipe Laying (b) 250mm thick wall
488Cutting drain width wise above GL for laying PVC pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in C.M. (1:4) with neat cement punning as per specifciation and direction of E/I. (PVC 110mm dia)
489Making holes in wall for laying PVC pipes and restoring the same all cost complete (PVC pipe 250mm dia)
490Supplying all tolls and labour and cutting chajja cornice for laying PVC pipes and making good the same as per specification and direction of E/I.
491Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 14.95% for labour and Contractors profit)
492Pillar cock Long neck (Basic rate Rs.756.60 + 30% for C.P. & laying charge)
493Bib cock - long thread (Basic rate Rs.701.10 + 30% for C.P. & laying charge)
494Angular Stop cock L.T.(Basic rate Rs.572.85 + 30% for C.P. & laying charge)
495Glass shelf (Basic rate Rs.641.25 + 30% for C.P. & laying charge
496Flush valve complete with 32mm size control cock & flange (Basic rate Rs.3283.00 + 30% for C.P. & laying charge
49732mm dia. PVC waste pipe 750mm long with cushion (Basic rate Rs.52.00 + 30% for C.P. & laying charge
49815mm C.P. nipple with coupling(As per JSR 15 basic rate Rs.72.70 + 30% C.P. & laying charge)
499Providing Solvent cement (as per JSR 15 basic item - 240.00 + 30% C.P & laying charge
500Supplying, fitting and fixing Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror. 600 X 450mm
501Supplying, fitting and fixing C.P. brass soap dish container medium quality with screw and hinges etc.
502Providing and fixing 15mm dia and 45cm long PVC connection pipe with heavy quality brass coupling at both ends etc all complete as per specification and direction of engineer in charge
503Supplying, materials and labour for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
504Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931, 15mm dia nominal bore of approved brand C.P. fittings
505Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quaility and colour 15mm nominal bore weighing not less than 32gms.
506Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc.
50720mm nominal bore
50825mm nominal bore
50932mm nominal bore
510External work - 40mm nominal bore
511Providing & fixing on wall face unplasticised - Rigid P.V.C. pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
512Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
513Single Tee with door
514110x110x110 ,mm
515Bend 87.5 degree
516110 mm bend
517Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
518EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
519EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
520EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
521Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
522Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge.
523Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)
524Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
525Providing and laying in position specified grade of reinforced cement concrete, exluding the cost of centring, shuttering, finishing and reinforcement: all work upto plinth work1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
526Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
527Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts, and struts etc. above plinth level upto floor five floor, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
528Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
529Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
530Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
531Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
532Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
533Reinforcement Bar in R.C.C. 5.5.5 JSR
5348mm 20%
53510mm 15%
53612 mm 15%
53716mm 30%
53820mm 20%
539Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I..
540Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
541Providing 19 mm thk. Water proof cement plaster (1:3) with clean coarse of sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
542Providing 12 mm Thk. cement plaster(1:6) on walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/ I
543Providing and laying vitrified Paring / Industrial tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than0.08% and conforming to IS: 15622 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 300x300x10 mm
544Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including the cost of scaffolding and taxes all complete as per building specification and direction of E/I.(Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification.)Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills& railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
545Finishing wall with Premium Acrylic Smooth Exterior paint of required shade with Silicon additives on new works in two or more coats applied @ 1.43 Ltrs/10 Sqm. Over and including base coat of water proofing cement paint applied @ 2.2 Kgs/10Sqm.
546Providing two coats of plastic emulsion of approved shade and make over a coat of of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying puuty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I Finishing walls with textured exterior paint of required shade :
547Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
548Providing and fixing ball bearing for rolling shutters.
549Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.)
550Carriage of materials from different surface or department stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
551Cement
552Chips
553Bricks
554Steel
555I) Watch Tower
556EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
557EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
558EARTH FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
559Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
560Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge.
561Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)
562Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
563Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto pinth level : 1:2:4(1 cement : 2 coarse sand (Zone III) : 4 graded stone aggregate 20 mm nominal size)
564Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
565Providing and laying in position specified grade of reinforced cement concrete, exluding the cost of centring, shuttering, finishing and reinforcement: all work upto plinth work1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
566Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
567Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts, and struts etc. above plinth level upto floor five floor, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
568Centering and shuttering including strutting, propping, etc. and removal of form for Foundations, footings, bases of columns, etc. mass concrete
569Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
570Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform
571Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15◦ landings, balcony, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases, above plinth level upto floor five level, exluding the cost of centring, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)
572Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies, and access, platform5.3.17.3 JSR
573Reinforcement Bar in R.C.C.
5748mm 20%
57510mm 15%
57612 mm 15%
57716mm 30%
57820mm 20%
579Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I..
580Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
581Providing 19 mm thk. Water proof cement plaster (1:3) with clean coarse of sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
582Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
583Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than0.08% and conforming to IS: 15622 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 600x600
584Finishing wall with Premium Acrylic Smooth Exterior paint of required shade with Silicon additives on new works in two or more coats applied @ 1.43 Ltrs/10 Sqm. Over and including base coat of water proofing cement paint applied @ 2.2 Kgs/10Sqm. All complete job.Providing and applying POP putty of 2 mm thickness over plastered surface to prepare the surface even and smooth all complete as per building specification and direction of E/l.
585Providing two coats of plastic emulsion of approved shade and make over a coat of of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying puuty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqmProviding and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
586Carriage of materials from different surface or department stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
587Cement
588Chips
589Bricks
590Steel
591Supplying, installation, testing and commissioning of 6 Passenger liftMR
592Fabrication, assembling 200A HRC TPN switch incoming and 100/63A TPN, 35KA MCCB outgoing 4 nos. lighting LT electrical sub distribution control panel with the foloowing accessoires: MR
593Supplying and fixing PVC fittings of approved make confirming to IS : 1729 including supplying nails and bobbins, fixing solutions including earth work or masonary work cutting and remaking and providilding as the case may be all complete as per specification and direction of E/I.
594PVC plain bend 100mm dia.
595PVC double junction with door and ear 100mm dia.
596PVC cowl - 100mm dia.
597Floor trap - 100mm dia.
598Ring rubber
599Lubricant
600Door piece
601Supply fitting and fixing of standard make starter panel board with arrangement of all necessary protection including all taxes, royalty etc. all complete job as per direction of E/I
602Providing Interior Fitout Work At Proposed model Zila Parishad Office Type - I - (Big)
603SUPPLY & INSTALLATION OF OFFICE BOUGHT OUT FURNITURE ITEMS At Proposed model Zila Parishad Office Type - I - (Big)
604Supply, Installation, Testing and Commissioning of IP Based CCTV Cameras& Supply, Installation, Commissioning Of Building Wide Wired And Wireless Local Area NetworkAt Proposed model Zila Parishad Office Type - I - (Big)
605Supply, Installation, Testing and Commissioning of Fire Fighting (Wet Riser) System At Proposed model Zila Parishad Office Type - I - (Big)
606Supply, Transportation & fitting of Shyan Jyoti LED Based Solar Street Lighting SystemLuminary: 12W LED LuminaryLuminary Housing- Weather Proof HousingStructure- Hot Deep Galvanized MS Pole(4.5 Mtr.)Battery Box: Corrosion Resistant Painted Power Coated Metal Battery Box Other:Suitable Cable, Etc. Battery:19.8Ah 14.8V Lithium-Ferro Battery of MNRE Approved Module:75Wp of HBL/ Gautam Solar/ IEC Equivalent (Cost includes 10% CP & 5% OHC) MR
607Supply and fixing precast RCC bench benches including finishing etc, all complete under instruction of Engineer - in - Charge MR
608Supply and fixing Dust-bin including painting finishing etc, all complete. MR
609Supply and fixing SIGNAGES MR
610Supplying and fixing PVC fittings of approved make confirming to IS : 1729 including supplying nails and bobbins, fixing solutions including earth work or masonary work cutting and remaking and providilding as the case may be all complete as per specification and direction of E/I.
611PVC plain bend 100mm dia.
612PVC double junction with door and ear 100mm dia.
613PVC cowl - 100mm dia.
614Floor trap - 100mm dia.
615Ring rubber
616Lubricant
617Door piece
618ProvidingSolar lighting of 50 kw At Proposed model Zila Parishad Office Type - I - (Big)
619Add 18% GST
620Add 1% Labour Cess Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58172281
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 8.01 Crore
LAST DATE 19-11-2026
Authority
Authority Name district administration
Work Description Tender For Construction Of Proposed Model Zila Parisad Office Building, Simdega, Jharkhand.
Basic Detail
Tender No ZP/SIMDEGA/01SBD/2026-27
Bidding Type Tender
Location
City Simdega
State Jharkhand
Key Dates
Publish Date 23 Oct 2026
Submission Date 19 Nov 2026
Open Date 21 Nov 2026
Finance
Tender Value 8.01 Crore
Tender Fee 10000
EMD 16.05 Lakhs
Exemption Not Available
Document List
BOQ_162395.xls
c7f7b4c0-3a7e-4517-8b57-2d5142c342e2.html
Tenderdoc.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Nov 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_162395.xls

html

c7f7b4c0-3a7e-4517-8b57-2d5142c342e2.html

pdf

Tenderdoc.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender