Housing Urban and Rular Development Government Departments Closing in 11 days TDR #58171858

Tender For Providing Medical Gas Pipe Arrangements In Between The Lmo Tank To The Existing Line To The Imcu & Aluminium Partition Arrangements To Surgical Store In Tirunelveli Medical College Hospital At Tirunelveli

Issued by Government Departments · Tirunelveli, Tamil Nadu
Tender Value
5.80 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
11 days left
EMD
5810
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tirunelveli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Medical Gas Pipe Arrangements In Between The Lmo Tank To The Existing Line To The Imcu & Aluminium Partition Arrangements To Surgical Store In Tirunelveli Medical College Hospital At Tirunelveli

BOQ

Name of Work:- Providing Medical Gas pipe arrangements in between the LMO Tank to the existing line to the IMCU & Aluminium Partition arrangements to Surgical store in Tirunelveli Medical College Hospital at Tirunelveli
Sl. No. Item Description
1Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the departmental officers.
2Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means
3Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means
4Supplying and fixing 40mm dia GI pipe for vertical post including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat), etc., as directed by the departmental officers
5Supplying and fixing of MS pipe for Vertical post, purlins & Rafters including labour charges for cutting, welding and fixing charges etc., and as directed by the departmental officers.
6Supplying and fixing Mild Steel angle for iron works for trusses and record racks etc etc.,complete complying with standard specifications and as directed by the departmental officers.
7Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
8Medial Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non aresenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling) The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg/ cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipe lines installed at hte various wings and floors etc., complete as directed by the Departmental Officers as per IS code 12827/1989 & ISO 7396/1987 Specification.
922mm OD 0.90mm thick copper pipe
1028mm OD 0.90mm thick copper pipe
11Brass Isolation Valve suitable for the copper pipe and should be of not lubricated 90 degree turn lever ball valve of reputed make, connected in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber \\"O\\" ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827 /1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827/1989 & ISO 7396/1987 Specification,
1228mm Isolation Valve
13Supplying and fixing of flexible tile pipe for both N2 and O2 connections etc., The rate includes all materials, transportation charges, fixing charges, necessary fittings, labour charges and all other incidental charges etc, complete and as directed by the departmental officers.
14Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
15Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition of size 3.50 x 2.88m. The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/ m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column,masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineer before use.
16Supplying, fabricating and fixing in position of Aluminium anodised natural colour matt finish of single leaf fully panelled sliding door with 12mm thick bothside prelaminated partile board at the Shutter bottom rail:[email protected] kg/m,Top & Verticle 50x44.45x2.50mm @ 1.292 kg/m,Lock rail 50x44.45x2.50mm @ 1.292 g/m, Running channel section:[email protected] kg/m, and necessary accessories such as Alu.clips 17.15x17.27x1.50mm @ 0.176 kg, Alu handle 100x30mm @ 0.988 kg/mfull length of handles on both sides, lock, roller, including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and waking hole to the required extent in RCC column, beam masonry with power drill wherever necessary and redoing the damaged portion to the original condition afterfixing etc. complete. All the Alu. sections are to be anodised.with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc.,
17GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58171858
AUTHORITY Government Departments
TENDER VALUE 5.80 Lakhs
LAST DATE 06-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Providing Medical Gas Pipe Arrangements In Between The Lmo Tank To The Existing Line To The Imcu & Aluminium Partition Arrangements To Surgical Store In Tirunelveli Medical College Hospital At Tirunelveli
Basic Detail
Tender No 10 (5) EE/2026-27 dated.22.10.2026
Bidding Type Tender
Location
City Tirunelveli
State Tamil Nadu
Key Dates
Publish Date 23 Oct 2026
Submission Date 06 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 5.80 Lakhs
Tender Fee Ref. Documents
EMD 5810
Exemption Not Available
Document List
0265aa96-b5fe-4106-a7dc-a35f3cc42ec5.html
BOQ_861234.xls
Tendercondition5.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

0265aa96-b5fe-4106-a7dc-a35f3cc42ec5.html

xls

BOQ_861234.xls

pdf

Tendercondition5.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender