Heavy Industries and Public Enterprises Government Departments Closing in 14 days TDR #58169032

Tender For Development Of Green Park And Construction Of Maintenance Room At Water Works At Migc Malout

Issued by Government Departments · Sri Muktsar Sahib, Punjab
Tender Value
1.02 Crore
Estimated cost
Bid Submission
10 Nov 2026
14 days left
EMD
2.06 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sri Muktsar Sahib → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Of Green Park And Construction Of Maintenance Room At Water Works At Migc Malout

BOQ

Name of Work:- Development of Green Park and Construction of Maintenance Room at Water Works at MIGC Malout
Sl. No. Item Description
1Development of Green Park -I
2Clearing Grass and Removal of Rubbish : Clearing grass and removal of rubbish up to a distance of 50 meters outside the periphery of the area as per technical clause 201 of MORT&H specifications
3Earth filling good quality earth obtained from borrow pites including compensation of earth, loading, unloading, carriage to site of work, spreading, watering, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H.
4Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres
5Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type.
6First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
7Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering))
8Reinforced cement concrete M-25 mechancially batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
9Reinforced cement concrete M-25 mechancially batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
10Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
11Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machine precast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005.
1220mm thick cement plaster 1:4 in two coat work.
1312.5 mm thick cement plaster 1:4
14Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 75mm o/d PVC pipe of 4 Kgf. / sqcm
15EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge. CPVC SDR 11 pipe & Fittings 25mm o/d
16Providing & Fixing in postion C.I.bib cock as per IS:210 with stainless steel spindle of approved make (to the approval of Engineer-incharge ) complete in all respect. 25mm i/d
17Compaction of Earth work Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers)
18Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications
19Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge . IS Code: 15658 (2006)
20Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
21Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
22Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
23Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
24Supply and installation of garden bench Chair type garden bench with L-shaped sides made of reinforced concrete (M30), thickness 100 mm, overall height 1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation
25Sub Head-2 - Manintenance room
26Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15 cm. layer with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
27Cement Concrete 1:4:8 with 40mm gauge stone aggregate using concrete mixer volumetric type.
28First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
29Earth filling Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
30Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
31Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
32Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines.
33First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
34Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
35Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
36Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure.
37Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
38Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
39Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
4012.5 mm thick cement plaster 1:4
4120mm thick cement plaster 1:4 in two coat work
42Plastering on underside of ceiling 10mm thick cement plaster 1:3
43Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps. U-PVC pipes (working pressure 4 kgf. / sqcm) pipe 110 mm dia.
44Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
45Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
46Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3
47Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.
48Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
49Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
50Supplying openable steel windows, of standard rolled steel Z sections, joints mitered and Electrically flash-welded, with iron fittings including necessary iron handles, Peg-stay catchers bolts, iron plugs and pressed steel projected hinges and glazing clips, complete (Excluding glazing ) and finished with two coats of ready mixed paint red lead non setting primer, Above one sqm Area.
51Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified abovebut including labour for fixing the same in position IS 2202-1 (1999): Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges, 35mm thick.
52Wire gauge Hollock wood door shutter without springs housed in chowkhat. 35 mm thick.
53Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
54Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area.
55Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete. I.S.I Designation No. II (size of door 701mm to 850mm).
56Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
57Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
58Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
59Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
60Base courseof floor consistingof 100mm thick cement concrete1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material
61Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laidon 20mm thick cement mortar1:4(1cement:4fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thicknessof tile which makes chips and scratches less notice able and make na ideal choice for high traffic zones.) Size 600x600 mm.
62Grouting the joints of flooring tiles having joints of 3mm width, using 2mm to 3mm gap using spacers and later this gap to be filled with cement based grout )withCement basegrout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm
63Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
64Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
65Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. Rectangular Sink with Deluxe Border Single Bowl Overall Size 555 mm x 475mm x 200 mm
66Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. uPVC Pipe 10 Kgf/cm225mm i/d
67Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect C.P. brass Bib cock long nose/ long body foam flow without flange
68Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
69Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
70Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
71Electrical Works
72PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:
73Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
74Overall size 1.5sq.mm (Un-sheathed)
75Overall size 2.5sq.mm (Un-sheathed)
76Overall size 4 sq.mm (Un-sheathed)
77RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
78Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface)
79Wiring fan point (With fan box)
80Wiring light point
81Wiring call-bell point
82Wiring 6Amp. wall socket point
83Wiring 6Amp. Plug control comprising wall socket point
84Wiring 16/20Amp. power plug control point
85Wiring light point without control switch.
86Wiring light point with double control switches.
87XLPE INSULATED UN-ARMOURED CABLES (LOOSE):
88Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
89Overall size 16sq.mm (2Core) Un-armoured (Loose)
90PVC, HDPE PIPES & PVC FLEXIBLE PIPES:
91Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
92Medium Gauge PVC Conduit Pipe 20mm dia. (Flushed)
93Medium Gauge PVC Conduit Pipe 25mm dia. (Flushed)
94Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed)
95SUPPLY AND ERECTION OF WIRING ACCESSORIES:
96Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:-
97Bakelite Batten Holder (Large size)
98MINIATURE CIRCUIT BREAKERS
99Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
100MCB Single Pole 6-32amp. (10kA, Curve-C)
101MCB Double Pole 40amp. (10kA, Curve-C)
102SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:
103Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
104SP&N Double Door Distribution Board 8 way each
105AC Plug and Socket SP&N with provision of One Single Pole MCB 20amp.
106GALVANIZED IRON PIPES AND G.I. EARTHING:
107G.I. EARTHING:
108Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-
109GI Earth rod 20 mm dia. 3 mtr. Long
110DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
111Supply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size.
112Double walled corrugated (DWC) HDPE pipe 50/ 38mm (outer/ inner dia.)
113Supply, erection, testing and commissioning of 120 watt LED Flood lighting fitting complete in all respect including petty material such as reducer, nuts/ bolts etc whats so ever is required to complete the job to entire satisfaction of Engineer in charge and as per following specifications Approved by Technical advisor to Hon’ble CM, Punjab vide Letter No AT/2021/GL/1410-1422, Dated 06-05-2021
114Providing, installation testing and commissioning of following Luminaires, Ceiling Fans & Exhaust fans.complete in respect including petty material such as connector, fan rod louver etc whatever is required to complete the job to entire satisfaction of Engineer-in Charge and the specifications of Luminaires should be as per Approved by Technical advisor to Hon’ble CM, Punjab vide Letter No AT/2021/GL/1410-1422, Dated 06-05-2021
115Supply, erection, testing and commissioning of 18/20 watt LED Batten rod four feet long complete in all respects to the entire satisfaction of engineer incharge .
116Supply, test, intall and commisioning of 48\\" (1200mm) 5 star BLDC ceiling fan with standered warranty , complete in all respect including petty maerial such as rod etc. to entire stasfaction of engg. in charge
117Supply and erection of 300mm Exhaust fan 900 rpm single phase ISI marked heavy duty motor with die cast Aluminium rotor mounted on two ball bearing with louver shutter on the wall/ window grill including erection, connections and testing etc. complete with flexible wire and other patty material complete in all respects as appd. and desired by the Engineer in-charge at site
118Supply, erection, testing and commissioning of 5 / 6 watt LED Downlight recess type complete in all respects to the entire satisfaction of engineer incharge .Down light Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58169032
AUTHORITY Government Departments
TENDER VALUE 1.02 Crore
LAST DATE 10-11-2026
Authority
Authority Name Department Of Industries And Commerce
Work Description Tender for Development Of Green Park And Construction Of Maintenance Room At Water Works At Migc Malout
Basic Detail
Tender No PSIEC/GreenPark/Malout
Bidding Type Tender
Location
City Sri Muktsar Sahib
State Punjab
Key Dates
Publish Date 23 Oct 2026
Submission Date 10 Nov 2026
Open Date 11 Nov 2026
Finance
Tender Value 1.02 Crore
Tender Fee 11800
EMD 2.06 Lakhs
Exemption Not Available
Document List
729d260f-1a77-437d-822d-26bda6a9cea6.html
BOQ_363526.xls
DNIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Nov 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

729d260f-1a77-437d-822d-26bda6a9cea6.html

xls

BOQ_363526.xls

pdf

DNIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender