Water Resources and Irrigation Government Departments Closing in 7 days TDR #58168465

Tender For General-Nava Kerala Sadhass - Thangassery Thirumullavaram Coastal Tourism Circuit - Infrastructure Development At Thirumullavaram Beach And Renovation Of Thangassery Fort Port-Thangassery Thirumullavaram Coastal Tourism Circuit - Infrastru

Issued by Government Departments · Kollam, Kerala
Tender Value
4.13 Crore
Estimated cost
Bid Submission
06 Nov 2026
7 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
9759
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kollam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-Nava Kerala Sadhass - Thangassery Thirumullavaram Coastal Tourism Circuit - Infrastructure Development At Thirumullavaram Beach And Renovation Of Thangassery Fort Port-Thangassery Thirumullavaram Coastal Tourism Circuit - Infrastructure Development At Thirumullavaram Beach And Renovation Of Thangassery Fort Port-General Civil Work

BOQ

Name of Work:- GENERAL-Nava Kerala Sadhass – Thangassery Thirumullavaram Coastal Tourism Circuit – Infrastructure Development at Thirumullavaram Beach and Renovation of Thangassery Fort Port-Thangassery Thirumullavaram Coastal Tourism Circuit – Infrastructure Development at Thirumullavaram Beach and Renovation of Thangassery Fort Port-General Civil Work
Sl. No. Item Description
1Appendix A-Thirumullavarom civil work
260.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
360.7.6:Supplying and stacking granite stone 20 to 45 dm3 for dumping works- Supplying at site of work granite stone 20 to 45 dm3 in size (60% 45m3,30%30 to 40dm3 and 10% 20 to 30dm3 stones) for measurement ( deducting not less than 15% for voids as fixed by the departmental officer at site) including all cost, conveyance, loading and unloading charges all other incidental charges all leads and lifts etc. complete as per the direction of the departmental officers at site.
460.7.7:Conveyance and dumping of departmental granite stones-Conveyance of departmental granite stone 20 to 45 dm3 in size from stack at site and dumping in position (60% 45m3,30%30 to 40dm3 and 10% 20 to 30dm3 stones) to lines and levels to from the core of the sea wall as per approved design including all leads and lifts etc. complete as per the direction of the departmental officers at site.
55.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
64.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
75.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
85.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
95.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
105.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
1116.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
128.2.2.2:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
13OD42627/2025-2026:Providing and casting RCC handrail of 150 mm diameter using PVC pipes (150 mm dia, 6 kgf/cm²) as permanent shuttering and protective outer casing, including cost of concrete, PVC pipe, labour, curing, alignment and all complete as per direction of Engineer-in-Charge.
14OD42628/2025-2026:Providing and laying Bangalore granite stone slab flooring, 20 mm average thickness, laid over cement mortar base 1:4 (1 cement : 4 coarse sand) 50 mm thick or as required, jointed with grey cement slurry mixed with approved pigment to match the shade of the slab, including rubbing, polishing, curing and all incidental works, complete as per direction of Engineer-in-Charge.
15OD42646/2025-2026:Providing and fixing sign board with 4 mm thick ACP board (1200 mm × 750 mm), letters made of 18 mm thick multiwood, fixed with mirror screws, mounted on 80 mm dia GI pipe post, complete as per approved design.
16OD42933/2025-2026:STONE BENCH - Providing and fixing stone bench of 1500cm with back rest support with 75mm thick solid krishnashila granite stone fixed on to vertical granite supports125mm thick, both having one line chiseled finish, and fixed with anchorage of 150mm embedded into PCC as per architectural drawings. Including cost of all material, labour charge, transportation,electricity and fuel for the generator etc all complete as per direction of Engineer in-charge
17OD42947/2025-2026:Portable toilet constructed from high-quality raw materials, ensuring durabilitythroughout its long life cycle. Suitable for mounting on a pre-existing platform or plain ground.Overall dimensions: 1100mm (width) * 1100mm (breadth) * 2340mm (height).Weight: 80kg,Material:Polyethylene. Certification: Products should be inspected and certified by ISO 18436 qualified engineers.Factory should holds ISO 9001-2015 certification.Optionsa) Mains connected typeCan connect to external treatment tanks; variants include Indian toilets, Western ceramics,urinal cabins, shower cabins, etc.b) Chemical toiletsFeatures built-in tanks, available in both Indian and Western styles. Including allplumbing works. Fitted at site, 5 year comprehensive maintenance contract including sludge removal, replacing damaged units. Etc. complete as per directions of officials at site.
18Appendix B-Walkway around pond Thirumullavaram
1916.91.2:Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
2016.1:Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
2116.78.2:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
2215.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
2360.7.9:RR with Departmental. Stone - Random rubble masonry using departmental rubble in foundation and plinth including through and bond stone and levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).
247.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
25Appendix C-Snack Bar (Thirumullavaram)
262.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
274.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
2850.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
2910.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
3013.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
319.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm
329.118.1:Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).
339.147D.3:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).
349.150:Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete.
359.151:Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete.
36Appendix D-For view point (New) Thirumullavaram
3760.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
384.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
394.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
405.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
4110.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
4213.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
43Appendix E-Thirumullavaram Electrical work
44OD16833/2026-2027:SITC of 40W All in one Integrated Solar street Light is an intelligent self-contained unit that is designed tobe freely mounted on standard octagonal pole, This integrated unit houses the solar module as the free source ofenergy, powerful Lithium based battery to store the solar energy generated in the day and complete powermanagement electronics to process the energy for effective use. It also has an integrated power LED driver and anLED module, SS Hardware + Aluminium Extrusion Frame, Automatic operation with inbuilt power management,Premium grade Polycrystalline silicon type, 60 Wp, IP65, compliance to IEC 61215 for design; IEC 61701 (Salt mistcorrosion test) performance and IEC 61730 (Safety class I & II) CE Inbuilt with BMS module & battery shall be shortcircuit, over discharge, overcharge, over temperature, CHARGING EFFICIENCY >90 %, DC DC EFFICIENCY > 90 withMOTION SENSOR, CCT -5700k, 150lm/W, Material: Aluminium pressure die cast, LED LIFE >50,000 hours, LM-80,fixture shall be die cast aluminium alloy, Battery: 24AH, 12.8V (307 Whr) Inbuilt with BMS Module.
45OD16834/2026-2027:SITC of decorative pole 4M height above the ground level made out of GI, tubular pole \\"T\\" washed andprimered. (ASTM A123, with minimum average GI coating of 65mM.), having two sections, the bottom section ofminimum 1000mm (L) x 140mm dia and the top section with minimum of 3000mm (L) x 76mm dia, in built junctionlooping box at bottom section with 32 A heavy-duty 4-way connector for loop in & loop out. Design comply EN40standard and basic wind speed 169kmph. The embellishments are cast in iron and fitted to the column by grubsscrew fitting.The Pole Base plate should be with 200x200x12 mm. The column shall also be provided with flush doorat the bottom with proper strengthening to the cut-out of the door opening. The Pole Shaft/pipe should befabricated out of Steel tube of grade YST 210/240.The pole shaft and base plate shall be hot dip galvanized (7stageprocess) as per IS 2629 having minimum average DFT of 65 microns before the coating of epoxy primer. Thecomplete pole treated with high quality epoxy zinc rich primer and thereafter coated with Polyurethane paint(marine grade) of minimum average DFT of 100 microns (Total pole thickness 165 micron). The pole shall haveinbuilt junction box consist of connector for loop in loop out and provision for MCB. The pole shall be of compositeconstruction designed to \\"wind load\\" corresponding to a basic wind speed of 169kmph without any deformation ordamage to the structure.
461.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
471.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
481.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
491.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
5090.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
512.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
522.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
532.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
542.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
551.23.1:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
562.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
571.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
581.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
591.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
601.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
611.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
621.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
631.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
645.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
655.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required
66OD54058/2025-2026:Supplying and fixing energy efficient 20W/230V 2000 Lumen LED tube with clips and screws
67OD54121/2025-2026:440mm x 380mm x 140mm Seven way process powder coating to protect from rust Package Contents : Meter Box With Three 63 Amps Fuse, L & T 4 Pole Switch disconnector unit & one 63 Amps Neutral Link
68Appendix F-Thirumullavaram CCTV works
69OD19299/2026-2027:Supplying, installation, Testing and commissioning of following capacity 8 port PoE Layer 2 Industrial Grade outdoor Network Switch having features and specifications etc. as mentioned here under: At least 8 X RJ-45 PoE/PoE+ Gigabit Ethernet Ports and additional 4 X 1G SFP Ports with non-blocking architecture by having Switching capacity of min.24Gbps and packet forwarding rate of 17Mpps or higher, console port, 16K MAC table, IPv4 and IPv6 ready, IGMP snooping v1, v2, v3, DHCP,DHCP Relay, NTP/SNTP, SNMPv1, v2 C v3, TELNET/ SSH, LACP, STP, RSTP, MSTP, ERPS. VLAN: Port based, Mac based, IP subnet based, tag based, protocol based. Qin Q, L2/L3 ACL, 1588v2 Precision Time Protocol HWBased E2E Transparent clock, SNTP, TFTP, SNMP, Radius, Syslog. Dual DC Power input, IP30 rated, DIN Rail, -5° to 70° C operating temperature. Certificate: UL, CE, FCC, NEMA-TS2, IEC/MIL-STD for Shock , Vibration & Drop Certificate. OEM Should have Certificate for Industrial Cyber Security Capability IEC- 62443-4-1:2018, ISO 45001, ISO 27001 and ISO 14001 Certified or Equivelent Indian Certificate. OEM/Product must be on Trusted Telecom Portal of Department of telecommunication, Government of India etc. complete as required.
70OD19301/2026-2027:Supplying, Installation, Testing and commissioning of Outdoor Wireless Access Point having features and specifications etc. as mentioned here under - WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, 4 x internal antennas, the transmission coverage of shall be minimum 80 meters in radius, AP should have transmission power minimum of 22 dBm, The AP shall provide a minimum of 29 dBm EIRP for both 2.4 GHz and 5 GHz frequencies. Feild deployment shall be with EIRP as per regulatory guidelines, AP shall have dual-band Omni-directional Antenna, either internal or external.Feild deployment shall be with EIRP as per the WPC guideline, WPA/WPA2/WPA3? Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Po tal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/ BandSteering, Supports enhanced security ? WPAPSK/ WPA2-PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks,IP68 water/dustproof standard, 6KV Surge Protection;4KV ESD Protection (contact), 6KV (air), Operating ambient temperature (-5~50 °C), Grounding point support, IEC 60601-1-2 EMC Medical Electrical Equipment Testing and Certification, EN50121-1 & EN50121-4 for Wireless Application. Certifications:MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role- Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication. OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required
71OD19302/2026-2027:Supplying, Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
72OD19303/2026-2027:Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord of length 1m(3ft) should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
73OD19305/2026-2027:Supplying and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. etc complete as required.
74OD19307/2026-2027:Supply and fixing following port Rack Mount loaded 6 port LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900?m tight buffered fiber storing, Capable of storing up to 3 meters of 900?m tight buffered fiber.
75OD19308/2026-2027:Supplying, Installation, Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- 2 MP IP IR motorized PTZ @ 25/30fps or better camera, Triple streaming , configurable on resolution Main stream: 1080p@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better, varifocal lens 4.3-137 mm or better with Automatic & manual Focus Adjustment provisions, 32x Optical zoom and 12x Digital zoom with angle of view 57??2.4? , PAN Travel: Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset : 300° /s, Tilt, Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200°/s
76OD19309/2026-2027:Supplying Installation Testing and Commissioning of 08 Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.
77OD19310/2026-2027:Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera 4MP @ 25/30fps@1440P (2560 x 1440) with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\"\\" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & NightHigh Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control, White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120dB or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input?12 VDC (via power adapter) and PoE (802.3af)?to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 40.4.1 4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement)
78OD19311/2026-2027:Supplying, Installation, Testing and Commissioning of 32 inch or larger LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4XHDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required.
79OD19312/2026-2027:Supply, installation, testing and Commissioning of Surveillance 6TB, SATA , 6Gb/s, 128 Cache, 7200 RPM, All stream supported, 3.5 inch form factor, UL Certification.
8090.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
8190.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
825.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required
83OD19410/2026-2027:Supply, installation, testing and commissioning of IP67 Outdoor PoE Surge Protector, 16KV Surge Protection for PoE+ Devices, Black Metal Enclosure, 4 Ports, Includes Power Cord and Mounting Hardware. Wide operating temperature from -40°C to 85 °C, Flexible wall or pole-mounted as per site requirements, etc., complete as required.
84OD19411/2026-2027:Splicing charges
85OD19412/2026-2027:Supplying and drawing of 6 core Outdoor Loose Tube Steel Wire Armoured 9/125um OS2 Type Optical Cable having optical fibres in water blocked loose tubes, dielectric tape wrapper, polyethylene (HDPE) inner sheathed, corrugated steel tape armoured (CSTA) polyethylene (HDPE) outer sheathed embedded with two steel wires on the periphery. Operating ambient Temperature shall be -40°C -+70°C, Max Attenuation ± 0.38 (db/ km) at Operational Wavelength 1310 nm and ± 0.25 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 um, manufactured and tested in accordance with TIA/EIA 568-C.3, ICEA-696, ISO.IEC 11801, CENLEC 50173, BELCORE GR 201, IEC 794-1, GR 406 CORE. ISO.IEC 11801 - 2nd Edition, type OS2 etc complete as required.
86OD19415/2026-2027:Supply, installation, testing and commissioning of 1000 VA / 800 W Double Conversion Online UPS, rack-mountable (2U), 230 V single phase, with input voltage range 110–280 V (half load) / 160–280 V (full load), input frequency 40–70 Hz auto sensing, pure sine wave output 230 V (configurable 220/230/240 V), output frequency 50/60 Hz ±3%, efficiency ≥88%, internal automatic & manual bypass, surge protection ≥600 J, crest factor 3:1, sealed maintenance-free lead-acid internal battery (36 V) with recharge time ≤4 hours, 4 × India 3-pin 6A output sockets, IEC C14 input, multifunction LCD display, audible alarms, USB & RS-232 communication ports, intelligent card slot, operating temperature 0–40°C, BIS certified, IP20, complete with rack mounting brackets, cables and all standard accessories, with minimum 2-year OEM warranty. Make: APC or equivalent.
87OD19413/2026-2027:Supply, drawing, testing and commissioning of outdoor Category 6 cable contains 4 Pair UTP sheathed with a grey LS0H compound. An additional layer of Heavy-Duty black PVC outer jacket renders the cablesuitable for outdoor installations, conforming to the standards Category 6 ANSI/TIA/EIA 568C.2, ISO/IEC 11801, IEC 61156-5, Colour Code as per TIA/EIA 568-B, RoHS Compliant, transmission performance tested up to 250 MHz or better in the existing conduit as required. Make: PANDUIT/ COMMSCOPE/ MOLEX/ NEXANS/ LEGRAND.
88OD19417/2026-2027:Supply installation testing commissioning of 3 Meters Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete
89OD19550/2026-2027:Supplying, Installation, Testing and commissioning of 1 G small form-Pluggable (SFP) Single-Strand Single Mode for Network Switches. Must support duplex LC connectors. Must be hot Pluggable, RoHS Compliant, etc. complete as required.
90OD19554/2026-2027:Supply, installation, testing and commissioning of Industrial-grade Dual SIM 4G LTE Wireless Router with support for FDD-LTE/TD-LTE and automatic 3G/2G fallback, minimum data speed of 150 Mbps download and 50 Mbps upload, IEEE 802.11 b/g/n Wi-Fi, minimum four (4) 10/100 Mbps RJ45 WAN/LAN ports, industrial-grade processor with minimum 128 MB RAM and 16 MB Flash memory, external SMA antennas (2 Nos. for 4G and 1 No. for Wi-Fi), metal enclosure (minimum IP30), operating temperature of -35°C to +75°C, complete with power adapter, mounting accessories, all necessary interconnections, configuration, testing, commissioning and making the system fully operational as required. Supply to include antennas, SMPS/ DC Supply with power accessories complete the work. Minimum 1-year warranty.
91OD19555/2026-2027:Supply, installation, activation and maintenance of 2 nos of 4G LTE Postpaid SIMs with Data plans for the industrial router installed at the site, valid for 36 months from commissioning. Plan shall provide minimum of 50 GB data per month, support Indian LTE bands (B1/B3/B5/B8 and TDD B40), and ensure 24×7 connectivity suitable for remote CCTV backhaul. SIM shall support static public IP or secure VPN-based remote access, be compatible with M2M/router usage, and include all activation charges and recurring charges including replacement of SIM, if necessary for the full 3-year period.
9290.16.4.3:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 6 mm GI strip
9390.12.1.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm
94OD19559/2026-2027:Supplying and fixing of Single Mode Patch Cord of Optical Fiber Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required.
9590.12.1.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm
96OD19579/2026-2027:Supply, installation, testing and commissioning of IP66 weatherproof side-opening CCTV camera housing for bullet camera installed at site, fabricated from heavy-duty stainless steel with corrosion-resistant finish, complete with anti-glare sunshield, built-in heater and blower for temperature and condensation control, side-hinged lockable access cover, tamper-resistant construction, adjustable mounting bracket with 360° pan and 90° tilt capability, suitable for outdoor industrial surveillance applications, including all mounting hardware, accessories, complete as required.
97OD19580/2026-2027:Supply, installation, testing and commissioning of Industrial 2 Port Gigabit Media converter IEEE802.3at/bt 90W RJ45 and 2 SFP Ports |10/100/1000Base-T, 100/1000M SFP, auto MDI/MDI-X, IEEE802.3af/at/bt,12~48V DC input, DIN-Rail, Metal case, Operating temp: -40°C to 75°C Including Power Supply
9890.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
99Appendix G-Beach Tourism project at Thangassery-Civil
1002.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1012.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
1024.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1034.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1047.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
1055.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
1065.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1075.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
1085.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
10930.2.10.2:Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).With grass Turf
1108.2.2.2:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
1119.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm
1129.118.1:Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).
11313.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
11413.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
11517.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
1167.2.1:Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
117OD42948/2025-2026:Providing and casting RCC handrail of 150 mm diameter using PVC pipes (150 mm dia, 6 kgf/cm²) as permanent shuttering and protective outer casing, including cost of concrete, PVC pipe, labour, curing, alignment and all complete as per direction of Engineer-in-Charge.
118OD42949/2025-2026:STONE BENCH - Providing and fixing stone bench of 1500cm with back rest support with 75mm thick solid krishnashila granite stone fixed on to vertical granite supports125mm thick, both having one line chiseled finish, and fixed with anchorage of 150mm embedded into PCC as per architectural drawings. Including cost of all material, labour charge, transportation,electricity and fuel for the generator etc all complete as per direction of Engineer in-charge
119OD42951/2025-2026:Providing and laying Bangalore granite stone slab flooring, 20 mm average thickness, laid over cement mortar base 1:4 (1 cement : 4 coarse sand) 50 mm thick or as required, jointed with grey cement slurry mixed with approved pigment to match the shade of the slab, including rubbing, polishing, curing and all incidental works, complete as per direction of Engineer-in-Charge.
120OD42961/2025-2026:Providing and fixing round stone table of 4ft or nearest available size with benchesset with 75mm thick solid krishnashila granite stone fixed on to vertical granite supports 125mm thick, both having one line chiseled finish, and fixed with anchorage of 150mm embedded into PCC as per architectural drawings. Including cost of all material, labour charge ,transportation, electricity and fuel for the generator etc all complete as per direction of Engineer - in-charge
121OD42969/2025-2026:Construction of STONE MANDAPAS, made of 300x300 mm krishnashila granitestone pillars, 3.33M height and connected with granite stone pergolas and fixed with necessary tongue and grove arrangements and 100X200 mm, both neatly chisel dressed provided with adhesive sealants of approved quality with necessary mouldings and groves as per drawings.The rate including cost of all materials, labour charge, transportation, electricity and fuel for the generator etc. designed as per the architectural drawings all complete as per direction of Engineer - in-charge.
122OD43001/2025-2026:Providing and fixing sign board with 4 mm thick ACP board (1200 mm × 750 mm), letters made of 18 mm thick multiwood, fixed with mirror screws, mounted on 80 mm dia GI pipe post, complete as per approved design.
123OD43038/2025-2026:Providing and fixing 3 mm thick polycarbonate corrugated sheets of approved make, supplied in single length up to 12 m or as decided by the Engineer-in-Charge, fixed using self-drilling / self-tapping screws (5.5 × 55 mm) with EPDM sealing washers, including cutting to size and shapes, fixing to horizontal / vertical / curved surfaces, but excluding the cost of purlins, rafters and trusses, complete.
124OD43090/2025-2026:Providing and laying Ist quality terracotta tiles, 12 mm thick, laid over 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
125OD43115/2025-2026:Fabricating and fixing front entrance gate made of cast iron members as perarchitectural drawings. Including cost of all material, labour charge ,transportation,electricity and fuel for the generator etc all complete as per direction of Engineer - incharge.
12615.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar
127Appendix H-Ramp (Thangassery fort)
1282.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1294.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1305.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
1318.2.2.1:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm
1322.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
13350.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
13413.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13513.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13610.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13713.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
138Appendix I-Chain link fencing (Thangassery fort)
1392.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1404.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1414.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1425.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
14350.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
14450.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
14513.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
14616.70.2:Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade
147OD43117/2025-2026:Providing and fixing sign board with 4 mm thick ACP board (1200 mm × 750 mm), letters made of 18 mm thick multiwood, fixed with mirror screws, mounted on 80 mm dia GI pipe post, complete as per approved design.
148Appendix J-Open stage (Thangassery fort)
1492.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1504.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1517.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
1527.2.1:Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
1535.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
1545.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1555.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
15650.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
1572.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1585.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
15913.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
16011.20.1:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement
16113.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
162Appendix K-Solid block structures (Thangassery fort)
1632.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1644.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1657.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
16650.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
16713.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
16813.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
169Appendix L-Seating arrangements around walkway (Thangassery fort)
1702.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1714.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
17250.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
17350.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
17413.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
17513.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
1764.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 gradedstone aggregate 40 mm nominal size derived from natural sources)
1778.2.2.1:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm
178Appendix M-Open gym & Badminton court (Thangassery Fort)
17916.1:Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
18016.78.2:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
1812.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1824.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
18350.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
18450.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
1854.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 gradedstone aggregate 40 mm nominal size derived from natural sources)
1865.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
18750.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
18813.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
18913.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
19013.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
19111.19.1:Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Light shade pigment using white cement
192OD43133/2025-2026: Supplying and Fixing DUAL SKIER Equipment at Site including the cost of Transportation and Fixing in position etc.. to complete as per the direction of engineer in charge
193OD43134/2025-2026:Supplying and Fixing OUTER CYCLE Equipment at Site including the cost ofTransportation and Fixing in position etc.. to complete as per the direction of engineer in charge
194OD43135/2025-2026:Supplying and Fixing SIT UP BENCH Equipment at Site including the cost ofTransportation and Fixing in position etc.. to complete as per the direction of engineer in charge
195OD43136/2025-2026:Supplying and Fixing HIP SHAPER Equipment at Site including the cost ofTransportation and Fixing in position etc.. to complete as per the direction of engineer in charge
196Appendix N-Floating bridge and walkway (Thangassery Fort)
1972.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1984.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
19916.91.2:Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
2004.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
201OD43138/2025-2026:Supplying and Fixing HDPE floating Bridge by enveloping Single layer HDPE Universal cubes confirm of ISO 9001 - 2008 including complete materials , labour and other charges complete including 3 years warranty for the the components used in floating bridge complete as per the direction of Engineer in charge.
202Appendix O-Snack bar (Thangassery Fort)
20350.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
2042.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2054.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
20610.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
20713.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
208OD43141/2025-2026:Supplying and Fixing Animal shape waste bin Equipment at Site including the cost of Transportation and Fixing in position etc.. to complete as per the direction of engineer in charge
209OD43142/2025-2026:Supplying and Fixing Bottle booth - Green waste bin at Site including the cost of Transportation and Fixing in position etc.. to complete as per the direction of engineer in charge.
210Appendix P-Kids Play Unit
211OD43143/2025-2026:Supplying and Fixing ROCKER BOAT small play Equipment at Site including thecost of Transportation and Fixing in position etc.. to complete as per the direction ofengineer in charge
212OD43146/2025-2026:Supplying and Fixing MERRY - GO - 6 SEAT FIXING play unit Equipment at Site including the cost of Transportation and Fixing in position etc.. to complete as per the direction of engineer in charge.
213OD43144/2025-2026:Supplying and Fixing SEE SAW 1 Pair play unit Equipment at Site including the cost of Transportation and Fixing inposition etc.. to complete as per the direction of engineer in charge.
214OD43145/2025-2026:Supplying and Fixing BALANCING WALKER play unit Equipment at Site including the cost of Transportation and Fixing in position etc.. to complete as per the direction of engineer in charge.
215Appendix Q-Thangassery fort Electrification
216OD16850/2026-2027:SITC of 40W All in one Integrated Solar street Light is an intelligent self-contained unit that is designed tobe freely mounted on standard octagonal pole, This integrated unit houses the solar module as the free source ofenergy, powerful Lithium based battery to store the solar energy generated in the day and complete powermanagement electronics to process the energy for effective use. It also has an integrated power LED driver and anLED module, SS Hardware + Aluminium Extrusion Frame, Automatic operation with inbuilt power management,Premium grade Polycrystalline silicon type, 60 Wp, IP65, compliance to IEC 61215 for design; IEC 61701 (Salt mistcorrosion test) performance and IEC 61730 (Safety class I & II) CE Inbuilt with BMS module & battery shall be shortcircuit, over discharge, overcharge, over temperature, CHARGING EFFICIENCY >90 %, DC EFFICIENCY > 90 withMOTION SENSOR, CCT -5700k, 150lm/W, Material: Aluminium pressure die cast, LED LIFE >50,000 hours, LM-80,fixture shall be die cast aluminium alloy, Battery: 24AH, 12.8V (307 Whr) Inbuilt with BMS Module.
217OD16882/2026-2027:SITC of decorative pole 4M height above the ground level made out of GI, tubular pole ?T? washed andprimered. (ASTM A123, with minimum average GI coating of 65?m.), having two sections, the bottom section ofminimum 1000mm (L) x 140mm dia and the top section with minimum of 3000mm (L) x 76mm dia, in built junctionlooping box at bottom section with 32 A heavy-duty 4-way connector for loop in & loop out. Design comply EN40standard and basic wind speed 169kmph. The embellishments are cast in iron and fitted to the column by grubsscrew fitting.The Pole Base plate should be with 200x200x12 mm. The column shall also be provided with flush doorat the bottom with proper strengthening to the cut-out of the door opening. The Pole Shaft/pipe should befabricated out of Steel tube of grade YST 210/240.The pole shaft and base plate shall be hot dip galvanized (7stageprocess) as per IS 2629 having minimum average DFT of 65 microns before the coating of epoxy primer. Thecomplete pole treated with high quality epoxy zinc rich primer and thereafter coated with Polyurethane paint(marine grade) of minimum average DFT of 100 microns (Total pole thickness 165 micron). The pole shall haveinbuilt junction box consist of connector for loop in loop out and provision for MCB. The pole shall be of composite?construction designed to ?wind load? corresponding to a basic wind speed of 169kmph without any deformation ordamage to the structure.(MARINE GRADE)
218OD30168/2026-2027:SITC of Outdoor Architectural Circular Disk Shape LED Bollard Luminaire with600mm (Max tolerance±10%) Height, System wattage 15W (Maxtolerance±10%) System efficacy>60LPW (±5%), CCT3000k/4000K/5700K , Circular Disk shape design should be suitable for 360°Rotosymmetric distribution diffused optics illumination suitable for >98% DLOR,Housing made of PDC Aluminium alloy ensuring optimum thermal management,Diffuser made of UV Stabilized injection molded Polycarbonate material. IP66Ingress Protection with Impact Resistance ≥ IK08. Fixture Top Dia Should not be165mm (Max tolerance±10%) with pole Did of 80mm (Maxtolerance±10%), Height of bollard should be 600mm/1000mm (As perapproval from Architect) , Driver should be Integral type Encapsulated highefficiency isolated constant current driver with protection Class 1. Inbuilt Surgeprotection of 6KV+20KV additional SPD, Mis wiring protection, Over voltageprotection, & Short circuit protection, Life 50,000 B Hrs@L70, CRI>70,THD0.95, Operating voltage 240V AC 50 hz, volatage rangesupporrted for 90-305V AC, Operating Tem 0 to +50°C, Operating Humidity10-90%. Fixture weight should not be more than 1.5-2KG (Maxtolerance±10%). Powder coating should be corrosion resistant Nanotechnology powder coating in Silver Grey/Black colour ( As per approval fromArchitect/Client). Fixture should have 5 Years warranty for complete system. Suitablefor mounting on RCC base.OEM should submit supporting documents along with bidTechnical Data Sheet, LM80, IEC 60598 test certificates & LM79 from NABLAccridated Lab. Manufacturer/OEM emblem/logo should be embossed into theAluminium housing to allow identification of OEM & traceability till the life ofthe fixture. Luminaire should have their OEM Logo embossed on PDC Aluminiumhousing of Luminaire for OEM authenticity & Identification throughout the lifeof Luminaire for after sales service support. LM80 report from LED Manufacturer,LM79, Safety test report as per IS 10322 from NABL Accredited lab, BIS Certificatewith manufacturer name the same as the brand proposed, , Type Test Report &RoHS compliance declaration should be submitted on request. Luminaire shouldcomply performance & Safety standards: IEC 60598, IS 10322-5, IS 16103/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015
21990.12.1.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm
22090.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
221OD30194/2026-2027:Supply, installation, testing and commissioning of outdoor type single-phase street-light feeder pillar, complete with suitable weatherproof CRCA/MS enclosure, lockable door, 2-pole incoming isolator, 2-pole RCCB, contactor, automatic/manual control arrangement with timer/photocell, suitable 6 SP outgoing MCBs for street-light/bollard-light circuits, neutral link, earth bar, indication lamps, internal copper wiring, cable glands, gland plate, cable lugs, ferrules, earthing connection and all necessary accessories, including complete termination, testing and commissioning, as required for a complete installation.
2221.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
2231.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
2241.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2251.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2261.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2271.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
2282.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
2292.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
2302.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2312.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2322.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
233OD15988/2026-2027:440mm x 380mm x 140mm Seven way process powder coating to protect from rust Package Contents : Meter Box With Three 63 Amps Fuse, L & T 4 Pole Switch disconnector unit & one 63 Amps Neutral Link
23490.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
2351.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
2361.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
2371.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
2381.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2391.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
240OD16008/2026-2027:Supply and installation of 9W LED bulb.(Make:Philips/Crompton/equivalent)Standard make and ISIMarked
241OD16009/2026-2027:Supply and installation of 20W LED tube light with all accessories as required.(Make: Crompton/Philips/Wipro)
242OD16011/2026-2027:Supply and fixing following size earth bench, fixing on surface of wall/parapet using iron screws, bench having holes for connecting earth strip/wires, making good the damages, colour washing etc as required. 25x3x400 mm Cu earth bench.
24390.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
24490.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
2455.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required
246Appendix R-Thangassery CCTV works
247OD19557/2026-2027:Supply, installation, activation and maintenance of 2 nos of 4G LTE Postpaid SIMs with Data plans for the industrial router installed at the site, valid for 36 months from commissioning. Plan shall provide minimum of 50 GB data per month, support Indian LTE bands (B1/B3/B5/B8 and TDD B40), and ensure 24×7 connectivity suitable for remote CCTV backhaul. SIM shall support static public IP or secure VPN-based remote access, be compatible with M2M/router usage, and include all activation charges and recurring charges including replacement of SIM, if necessary for the full 3-year period.
248OD19558/2026-2027:Supplying and fixing of Single Mode Patch Cord of Optical Fiber Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required.
249OD19556/2026-2027:Supply, installation, testing and commissioning of Industrial-grade Dual SIM 4G LTE Wireless Router with support for FDD-LTE/TD-LTE and automatic 3G/2G fallback, minimum data speed of 150 Mbps download and 50 Mbps upload, IEEE 802.11 b/g/n Wi-Fi, minimum four (4) 10/100 Mbps RJ45 WAN/LAN ports, industrial-grade processor with minimum 128 MB RAM and 16 MB Flash memory, external SMA antennas (2 Nos. for 4G and 1 No. for Wi-Fi), metal enclosure (minimum IP30), operating temperature of -35°C to +75°C, complete with power adapter, mounting accessories, all necessary interconnections, configuration, testing, commissioning and making the system fully operational as required. Supply to include antennas, SMPS/ DC Supply with power accessories complete the work. Minimum 1-year warranty.
250OD19560/2026-2027:Supplying, Installation, Testing and commissioning of 1 G small form-Pluggable (SFP) Single-Strand Single Mode for Network Switches. Must support duplex LC connectors. Must be hot Pluggable, RoHS Compliant, etc. complete as required.
251OD19561/2026-2027:Supply installation testing commissioning of 3 Meters Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete
252OD19562/2026-2027:Supply, installation, testing and commissioning of IP67 Outdoor PoE Surge Protector, 16KV Surge Protection for PoE+ Devices, Black Metal Enclosure, 4 Ports, Includes Power Cord and Mounting Hardware. Wide operating temperature from -40°C to 85 °C, Flexible wall or pole-mounted as per site requirements, etc., complete as required.
253OD19563/2026-2027:Splicing charges
254OD19564/2026-2027:Supplying and drawing of 6 core Outdoor Loose Tube Steel Wire Armoured 9/125um OS2 Type Optical Cable having optical fibres in water blocked loose tubes, dielectric tape wrapper, polyethylene (HDPE) inner sheathed, corrugated steel tape armoured (CSTA) polyethylene (HDPE) outer sheathed embedded with two steel wires on the periphery. Operating ambient Temperature shall be -40°C -+70°C, Max Attenuation ± 0.38 (db/ km) at Operational Wavelength 1310 nm and ± 0.25 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 um, manufactured and tested in accordance with TIA/EIA 568-C.3, ICEA-696, ISO.IEC 11801, CENLEC 50173, BELCORE GR 201, IEC 794-1, GR 406 CORE. ISO.IEC 11801 - 2nd Edition, type OS2 etc complete as required.
255OD19565/2026-2027:Supply, drawing, testing and commissioning of outdoor Category 6 cable contains 4 Pair UTP sheathed with a grey LS0H compound. An additional layer of Heavy-Duty black PVC outer jacket renders the cablesuitable for outdoor installations, conforming to the standards Category 6 ANSI/TIA/EIA 568C.2, ISO/IEC 11801, IEC 61156-5, Colour Code as per TIA/EIA 568-B, RoHS Compliant, transmission performance tested up to 250 MHz or better in the existing conduit as required. Make: PANDUIT/ COMMSCOPE/ MOLEX/ NEXANS/ LEGRAND.
256OD19566/2026-2027:Supply, installation, testing and commissioning of 1000 VA / 800 W Double Conversion Online UPS, rack-mountable (2U), 230 V single phase, with input voltage range 110–280 V (half load) / 160–280 V (full load), input frequency 40–70 Hz auto sensing, pure sine wave output 230 V (configurable 220/230/240 V), output frequency 50/60 Hz ±3%, efficiency ≥88%, internal automatic & manual bypass, surge protection ≥600 J, crest factor 3:1, sealed maintenance-free lead-acid internal battery (36 V) with recharge time ≤4 hours, 4 × India 3-pin 6A output sockets, IEC C14 input, multifunction LCD display, audible alarms, USB & RS-232 communication ports, intelligent card slot, operating temperature 0–40°C, BIS certified, IP20, complete with rack mounting brackets, cables and all standard accessories, with minimum 2-year OEM warranty. Make: APC or equivalent.
257OD19567/2026-2027:Supplying, installation, Testing and commissioning of following capacity 8 port PoE Layer 2 Industrial Grade outdoor Network Switch having features and specifications etc. as mentioned here under: At least 8 X RJ-45 PoE/PoE+ Gigabit Ethernet Ports and additional 4 X 1G SFP Ports with non-blocking architecture by having Switching capacity of min.24Gbps and packet forwarding rate of 17Mpps or higher, console port, 16K MAC table, IPv4 and IPv6 ready, IGMP snooping v1, v2, v3, DHCP,DHCP Relay, NTP/SNTP, SNMPv1, v2 C v3, TELNET/ SSH, LACP, STP, RSTP, MSTP, ERPS. VLAN: Port based, Mac based, IP subnet based, tag based, protocol based. Qin Q, L2/L3 ACL, 1588v2 Precision Time Protocol HWBased E2E Transparent clock, SNTP, TFTP, SNMP, Radius, Syslog. Dual DC Power input, IP30 rated, DIN Rail, -5° to 70° C operating temperature. Certificate: UL, CE, FCC, NEMA-TS2, IEC/MIL-STD for Shock , Vibration & Drop Certificate. OEM Should have Certificate for Industrial Cyber Security Capability IEC- 62443-4-1:2018, ISO 45001, ISO 27001 and ISO 14001 Certified or Equivelent Indian Certificate. OEM/Product must be on Trusted Telecom Portal of Department of telecommunication, Government of India etc. complete as required.
258OD19568/2026-2027:Supplying, Installation, Testing and commissioning of Outdoor Wireless Access Point having features and specifications etc. as mentioned here under - WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, 4 x internal antennas, the transmission coverage of shall be minimum 80 meters in radius, AP should have transmission power minimum of 22 dBm, The AP shall provide a minimum of 29 dBm EIRP for both 2.4 GHz and 5 GHz frequencies. Feild deployment shall be with EIRP as per regulatory guidelines, AP shall have dual-band Omni-directional Antenna, either internal or external.Feild deployment shall be with EIRP as per the WPC guideline, WPA/WPA2/WPA3? Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Po tal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/ BandSteering, Supports enhanced security ? WPAPSK/ WPA2-PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks,IP68 water/dustproof standard, 6KV Surge Protection;4KV ESD Protection (contact), 6KV (air), Operating ambient temperature (-5~50 °C), Grounding point support, IEC 60601-1-2 EMC Medical Electrical Equipment Testing and Certification, EN50121-1 & EN50121-4 for Wireless Application. Certifications:MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role- Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication. OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required
259OD19569/2026-2027:Supplying, Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
260OD19570/2026-2027:Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord of length 1m(3ft) should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
261OD19571/2026-2027:Supplying and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. etc complete as required.
262OD19572/2026-2027:Supply and fixing following port Rack Mount loaded 6 port LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900?m tight buffered fiber storing, Capable of storing up to 3 meters of 900?m tight buffered fiber.
263OD19573/2026-2027:Supplying, Installation, Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- 2 MP IP IR motorized PTZ @ 25/30fps or better camera, Triple streaming , configurable on resolution Main stream: 1080p@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better, varifocal lens 4.3-137 mm or better with Automatic & manual Focus Adjustment provisions, 32x Optical zoom and 12x Digital zoom with angle of view 57??2.4? , PAN Travel: Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset : 300° /s, Tilt, Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200°/s
264OD19574/2026-2027:Supplying Installation Testing and Commissioning of 08 Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.
265OD19575/2026-2027:Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera 4MP @ 25/30fps@1440P (2560 x 1440) with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\"\\" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & NightHigh Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control, White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120dB or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input?12 VDC (via power adapter) and PoE (802.3af)?to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 40.4.1 4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement)
266OD19577/2026-2027:Supply, installation, testing and Commissioning of Surveillance 6TB, SATA , 6Gb/s, 128 Cache, 7200 RPM, All stream supported, 3.5 inch form factor, UL Certification.
267OD19576/2026-2027:Supplying, Installation, Testing and Commissioning of 32 inch or larger LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4XHDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required.
26890.12.1.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm
26990.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
27090.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
27190.16.4.3:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 6 mm GI strip
27290.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
2735.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required
274OD19581/2026-2027:Supply, installation, testing and commissioning of IP66 weatherproof side-opening CCTV camera housing for bullet camera installed at site, fabricated from heavy-duty stainless steel with corrosion-resistant finish, complete with anti-glare sunshield, built-in heater and blower for temperature and condensation control, side-hinged lockable access cover, tamper-resistant construction, adjustable mounting bracket with 360° pan and 90° tilt capability, suitable for outdoor industrial surveillance applications, including all mounting hardware, accessories, complete as required.
275OD19582/2026-2027:Supply, installation, testing and commissioning of Industrial 2 Port Gigabit Media converter IEEE802.3at/bt 90W RJ45 and 2 SFP Ports |10/100/1000Base-T, 100/1000M SFP, auto MDI/MDI-X, IEEE802.3af/at/bt,12~48V DC input, DIN-Rail, Metal case, Operating temp: -40°C to 75°C Including Power Supply
27690.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58168465
AUTHORITY Government Departments
TENDER VALUE 4.13 Crore
LAST DATE 06-11-2026
Authority
Authority Name Kerala Irrigation Infrastructure Development Corporation Limited
Work Description Tender for General-Nava Kerala Sadhass - Thangassery Thirumullavaram Coastal Tourism Circuit - Infrastructure Development At Thirumullavaram Beach And Renovation Of Thangassery Fort Port-Thangassery Thirumullavaram Coastal Tourism Circuit - Infrastructure Development At Thirumullavaram Beach And Renovation Of Thangassery Fort Port-General Civil Work
Basic Detail
Tender No IRR/KIIDC/TR/451/2026_5_1_1/1
Bidding Type Tender
Location
City Kollam
State Kerala
Key Dates
Publish Date 23 Oct 2026
Submission Date 06 Nov 2026
Open Date 09 Nov 2026
Finance
Tender Value 4.13 Crore
Tender Fee 9759
EMD 1 Lakhs
Exemption Not Available
Document List
6a2d686b-7339-4f8f-a0dd-24b6e7013198.html
BOQ_1500010.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

6a2d686b-7339-4f8f-a0dd-24b6e7013198.html

xls

BOQ_1500010.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender