Tender For Remaining Development Works At Soorkuti Samadhi Site In Gram Parasoli.
Tender Value
86.55 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
6 days left
EMD
4.33 Lakhs
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mathura → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Remaining Development Works At Soorkuti Samadhi Site In Gram Parasoli.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 2 | Tile brick masonry (for specailized work) with common burnt clay F.P.S. (non modular) tile bricks of class designation 10 in superstructure above plinth level up to floor V level in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 3 | Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand): Flush/ Ruled/ Struck or weathered pointing |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 6 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in mouldings as in cornices, windows sills etc, including setting in cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | Providing and fixing machine cut dressed 75 mm pink sand stone (Bansi Paharpur) \\"Dasa/coping\\" with ornamental slope having moulding and pan shape engraving as per required pattern , with engraving deoth of 5mm avegrage in single piece of length 90 cm to be laid on cement mortar 1:4 12 to 20 mm thick inlcuding pointing with admixture of pigment marhcing with stone shade. |
| 8 | Providing Square Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos (3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of officer-in-charge. |
| 9 | Red sand stone slab 40 mm thick |
| 10 | GWALIOR WHITE Sandstone (30mm thick) Size 800×680mm Letters Engraving depth 2-5mm. (EXCLUDING TRANSPORTATION) |
| 11 | De-vegetation from monument by removing bushes, trees including complete uprooting from the wall & roofs/structures carefully including suitable chemical treatment to roots to avoid further growth including disposal of rubbish with in 50 mtr. Lead as per direction of Engineer in-charge. |
| 12 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workment etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item |
| 13 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping groundwithin 50 metres lead. |
| 14 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer- in-charge. |
| 15 | Carefully dismantling stone slab roofing over wooden karries or R.C.C. battens (dismantling karries and battens to be paid for separately), including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 16 | Dismantling steel work in single section(MS Girder) very-2 carefully and slowly to avoid any damage to the adjoining portion/members of the heritage structure after inspecting and re-strengtening to provided propping system to avoid any untoward incident during execution of work, including dismembering and stacking 50 mtrs. away from the site. |
| 17 | Provision of support during dismantling in place of removed girders to avoid damage to heritage structure and make the site safe for workers during execution of work. |
| 18 | Stitching of wide cracks carefully by taking out all loose materials, cleaning with pressure water pumps & air blower and filling 1/3 depth with lime mortar with cross masonry stitching using Brass/SS clamps and chiken mesh with matching bricks in lime mortar 1:1:1 (1 lime putty : 1 coarse sand: 1surkhi) matching the courses and features of existing masonry under the supervision of the conservation architect.. |
| 19 | Traditional brick masonry in custom made nanakshahi or lakhori bricks in lime mortar in proportion similar to the existing traditional lime mortar 1:1:1 (lime :1 sand : 1surkhi) Note: The cost may change from region to region due to change in rate of customized bricks. |
| 20 | Centering and shuttering including strutting, propping etc. and removalof form for Suspended floors, roofs, landings, balconies and accessplatform |
| 21 | Providing and fixing Structural steel work in single section(MS Girder (galvanised)) fixed with or without connecting plate, including cutting, hoisting & fixing in position as per original pattern after galvanising of the (MS Girder) all complete. |
| 22 | Providing Red Sand Stone slab for roofing and laying them in lime mortar 1 : 2 (1 lime : 2 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with lime mortar 1:1 (1 lime : 1 fine sand).Undressd Red sand stone slab - 50 mm thick |
| 23 | Providing & laying lime concrete in the ratio of 1:1:1:4 (1 Lime: 1 Surkhi: 1 coarse sand: 4 Brick ballast 25mm nominal size) mixed with Gur/ sheera and Belgiri etc. including ramming with wooden dhurmut. . |
| 24 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making Bpattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to bedone in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 25 | Making khurras 45 x 45 cm with average minimum thickness of 10 cm lime concrete 1:3:6 (1 Slaked lime :3 surkhi : 6 coarse sand) with graded brick aggregate 20mm nominal size over PVC sheet 1m x 1m x 400 micron, finished with 12mm lime mortar 1:3 (1 Slaked lime : 3 Coarse sand), rounding the edges and making and finishing the outlet complete. |
| 26 | Providing and fixing horizontal challa of stone 40 mm thick and upto 80cm projection in cement mortar 1 :4 (1 cement: 4 coarse sand), includingpointing in white cement mortar 1 :2 (1 white cement : 2 stone dust) withan admixture of pigment matching the stone shade :Red sand stone |
| 27 | mason grade -2 |
| 28 | Making cornice band with ornamental design as per the existing design with lime plaster 1::1:1(1 lime putty : 1 coarse sand : 1surkhi)Size 150 mm wide and 50 mm average thickness |
| 29 | Stucco work in lime, Surkhi, mortar (1:2) as per existing design work/ traditional practices by skilled craftsman, the stucco work should be done as per restoration nature, the mortar should be prepared by grinding mill adding gur, methi & gugal.. The thickness varies from 50 mm to 100mm as per the design (minimum rectangular surface area to be measured). |
| 30 | Total |
| 31 | Disposal of building rubbish / malba /similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 32 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with lime mortar 1:1:1 (1LIME:1surkhi:1coarse sand) with an admixture of pigment to match the shade of stone.Red sand stone |
| 33 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10metre height, backing filled with a grout of average 12 mm thick cementmortar 1 :3 (1 cement: 3 coarse sand) including pointing in white cementmortar 1 :2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing. 40 mm thick |
| 34 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 35 | Providing & fixing door, window, chowkhats and other frames, including anti termite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade :Second class teak wood |
| 36 | Providing and fixing double leaf door wooden shutters made of Ist grade wood as per traditional design (Deshi pattern) planks thickness 40mm and width of Binies, Andheri 50mm and 35mm, including Adwa etc. with fittings (nails, sankal, kunda, cheri, handle and patti etc.) as per existing matching/ as per approved design with moulding/ carving complete in all respect :M.P teak wood grade Ist |
| 37 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes |
| 38 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm |
| 39 | MS Channel 175 mm box vertically placed(as shaft) over base plate of 10 mm and at top with a base plate of 10 mm for pressure jack |
| 40 | Provision of M.S plate (10 mm Thickness ) below support during dismantling in place of removed girders to avoid damage to heritage structure and make the site safe for workers during execution of work. |
| 41 | Pressure jack required to support the roof during dismantling and fixing MS girder(Galvanised) to carry and transfer the load uniformily to the ground without failure. |
| 42 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. complete as required. |
| 43 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. complete as required. |
| 44 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 45 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 46 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 47 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 48 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 49 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit complete as required. 25 mm |
| 50 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ,single core cable in surface/recessed steel conduit complete as required.( For Lift) 4 x 10 sq.mm + 2 x 6 sq.mm earth wire. |
| 51 | 4 x 16 sq.mm + 2 x 6 sq.mm earth wire. |
| 52 | Supplying and fixing metal box of following sizes / modules ,GI box along with modular base and cover plate for modular switches in recess etc. as required. 6 module ( 125mm x 75 mm ) |
| 53 | Supplying and fixing following modular base and cover plate on exisiting modular metal boxes as required. as required. 6 module |
| 54 | Supplying and fixing following modular switch/socket on the exisiting modular plate and switch box including connections but excluding modular plate as required. as required. 5/6A switch |
| 55 | 3 pin 5/6A socket outlet. |
| 56 | Manufacture testing at works supply, installation, testing and commissioning of the following extensible cubicle type indoor mounting, dead front, fully compartmentalised with hinged lockable detachable front & back openable, dust and vermin proof, floor mounting sheet steel clad switchboard fabricated out of 2 mm thick CRCA powder coated sheet steel suitable for use at 415 volts 3 phase 4 wire 50 cycle system and to withstand a symmetrical fault level of specified at 415 volts. Panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition. All incomer breaker and Bus Couplers shall be interlocked electrically as shown in SLD and specifications. (Form- III B) SDB-1 (L&P) Panel as described above and specifications complete |
| 57 | DISTRIBUTION BOARDSSupplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 Way Double door |
| 58 | 8 Way Double door |
| 59 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door |
| 60 | 12 way (8 + 36), Double door |
| 61 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 62 | Double pole |
| 63 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 64 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 65 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 66 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amp |
| 67 | Supplying and fixing following rating, Triple pole, 415 V, MCB 10KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amp |
| 68 | Supply Installation, testing & commisioning of 32 amp, IP-44 1-Phase industrial socket outlet, switched with Electrical & Mechanical Interlocking in a single moulding, Plug, FRLS TheMetreoplastic box, Gel Polyurethane gasket, Padlocking arrangement, to be mounted on Existing Raceway complete as required. |
| 69 | Supply Installation, testing & commisioning of 32 amp, IP-44 3-Phase industrial socket outlet, switched with Electrical & Mechanical Interlocking in a single moulding, Plug, FR Thermoplastic box, Gel Polyurethane gasket, Padlocking arrangement, to be mounted on Existing Raceway complete as required. |
| 70 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 71 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 72 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 6 sq. mm |
| 73 | Supply & Laying of non skid Electro mat 1mtr wide and 2.0 mm thick 1.1KV grade IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities. |
| 74 | Supply, laying, testing & Commissioning of the following PVC Insulated Copper Conductor Armoured Control Cable including Termination. 8 core 1.5 Sq.mm |
| 75 | 10 core 1.5 Sq.mm |
| 76 | 12 core 1.5 Sq.mm |
| 77 | 2core 1.5 Sq.mm shielded |
| 78 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63mmdia ( OD-63mm & ID-51MM nominal ) |
| 79 | 200mmdia ( OD-200mm & ID-175MM nominal ) |
| 80 | Providing, making,fixing of MAN HOLE chambers as detailed below, 75mm thick 1:5:10 PCC flooring (as approved) complete as required and approved by the Project Manager including providing sleaves 450 mm L x 450 mm W x 600 mm deep(HT) with RCC framing of man hole & ISI Mark Heavy Duty Recessed DI cover as approved |
| 81 | SH-III CABLES, CABLE TRAY & RACEWAYS Supply of following LT-XLPE 1100 volts grade ISI marked cables complete as required and as per tender specifications. 3.5 x 50 sq.mm AL.Armoured |
| 82 | 4 x 25 sq.mm AL.Armoured |
| 83 | 4 x 10 sq.mm Copper Armoured |
| 84 | 4 x 6 sq.mm Copper Armoured |
| 85 | 4 x 4 sq.mm Copper Armoured |
| 86 | 3 x 6 sq.mm Copper Armoured |
| 87 | 2 x 6 sq.mm Copper (For Body & Dedicated Earthing) Armoured |
| 88 | 35 Sq,mm Copper Armoured cable, Single Core |
| 89 | 16 Sq,mm Copper Armoured cable, Single Core |
| 90 | 35 Sq,mm Copper unarmoured cable, Single Core. |
| 91 | 50 Sq,mm Copper unarmoured cable, Single Core. |
| 92 | Supply, of following Fire Survival Armoured Cable of 600/1000V rated with Aluminium conductor having Glass Mica (Fire Barrier) tape covered by an extruded layer of cross linkable GP6/GP8/Ei5 insulation and LSZH inner & outer sheath. Basic Design as per BS:7846 for Aluminium cables, should retain circuit integrity for 3 Hours as per Category - 3 of BS:8519. (BRE GLOBAL / LPCB / TUV certified) (FIRE SURVIVAL CABLE) 3.5 x 120 sq.mm AL.Armoured 4 x 35 sq.mm AL.Armoured |
| 93 | 4 x 6 sq.mm Copper Armoured |
| 94 | 4 x 4 sq.mm Copper Armoured |
| 95 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 50 sq.mm (35 mm) |
| 96 | 4 x 35 sq.mm (32 mm) |
| 97 | 4 x 25 sq.mm (28 mm) |
| 98 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 4 x 10 sq.mm |
| 99 | 4 x 6 sq.mm |
| 100 | 4 x 4 sq.mm |
| 101 | 3 x 6 sq.mm |
| 102 | 2 x 6 sq.mm |
| 103 | 16 Sq mm single core, |
| 104 | 35 Sq mm single core |
| 105 | 50 Sq mm single core |
| 106 | Laying & fixing of one number PVC insulated & PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Up to 35 sq.mm (clamped with 1mm thick saddle) |
| 107 | Above 35 Sq.mm & up to 95 Sq.mm (Clamped with 25x3 mm MS flat clamp) |
| 108 | Providing and fixing 6 SWG dia G.I Wire on surface or in recess for loop earthing as required. |
| 109 | Supplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width x 62.5mm depth x 2.0 mm thickness |
| 110 | 450 mm width x 62.5mm depth x 2.0 mm thickness |
| 111 | 300 mm width x 62.5mm depth x 2.0 mm thickness |
| 112 | 150 mm width x 50mm depth x 1.6 mm thickness |
| 113 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 6 sq mm Copper Wire (For Body Earthing for 1 PH DB's). |
| 114 | Supply and fixing of following sizes of MS Powder Coated raceway 14 gauge, with openable cover, with all accessories as required including junction boxes, orange colour for power and blue colour for data, suspended from the ceiling including providing suspension arrangement with all accessories in an approved manner complete as required. Required junction boxes will be provided for smooth pulling of structured and power cabling. It will be the responsibility of the contractor to coordinate with structured cabling contractor for laying of cable. 225mm x 38mm |
| 115 | 150mm x 38mm |
| 116 | SH-IV EARTHING SYSTEMEarthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 117 | Earthing with GI earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 118 | Supply,installation,testing and commissioning of Earth box made of 2mm thick MS painted,with a glass cover and having 50 x 6 mm Cu strip tinned with insulators complete as required. |
| 119 | Supply, installation,testing and commissioning of Earth box of suitable size made out of 2mm thick MS painted ,with a glass cover and having 25 x 6 mm Copper bus strips tinned complete with insulators complete as required. |
| 120 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 121 | Supplying and laying of the following earthing on surface or in recess or clamped to wall / cable tray with suitable clamps saddles and fixing bolts / soldering /rivetingas required and complete as required to comply with IS 3043. 25 mm x 6 mm Cu strip with heat shrinkable sleeves |
| 122 | 25 mm x 6 mm GI strip |
| 123 | 50 x 6 mm GI strips (On Cable Tray) |
| 124 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all60 ancillaries and accessories like coupler etc. as required. |
| 125 | SH-V LIGHTING & FIXTURESSupply, installation, testing and commissioning of the following fixtures with all accessories including drivers, LED Lamps complete etc. as required. Lights Geniso 2X2 Panel Recessed Indoor Fixture Light Source : LEDWattage : 36WIngress Protection : 40Optics : Opal DiffuserCCT : 3000K/4000K/5700KColour Rendering Index : Ra > 80Control Gear : NON-DimmableUGR : <19Rated Life Hours : L70 (50, 000Hrs)Beam angle :120°Material : Sheet MetalMounting : RecessedFinish : Powder CoatedDimension : LXW=595X595mm ,H=30mm |
| 126 | Lights Downlighter Flexion 90 Recessed Downlighter Indoor Fixture Light Source : COBWattage : 15/12WIngress Protection : 40Optics : Lens & Reflector CCT : 3000K/4000K/5700KColour Rendering Index : Ra > 80Control Gear : NON-DimmableUGR : <19Rated Life Hours : L70 (50, 000Hrs)Beam angle :15°/24°/38°Material : Die-cast Aluminium Mounting : RecessedFinish : Powder CoatedDimension: Outer Dia=106mm, Cutout Dia=95mm,H=119mm |
| 127 | Lights Downlighter Recessed Downlighter Indoor Fixture Light Source : TrackWattage : 30WIngress Protection : 40Optics : Lens & Reflector CCT : 3000K/4000K/5700KColour Rendering Index : Ra > 80Control Gear : NON-DimmableUGR : <19Rated Life Hours : L70 (50, 000Hrs)Beam angle :15°/24°/38°/45°/60°Material : Die-cast Aluminium Mounting : RecessedFinish : Powder CoatedDimension : Outer Dia= 140mm, Cutout Dia=115mm,H=165mm |
| 128 | power track 2mtr |
| 129 | Lights Alina Surface Downlighter Indoor Fixture Light Source : LEDWattage : 18WIngress Protection : 40Optics : Opal DiffuserCCT : 3000K/4000K/5700KColour Rendering Index : Ra > 80Control Gear : NON-DimmableUGR : <19Rated Life Hours : L70 (50, 000Hrs)Beam angle :110°Material : Die-cast Aluminium Mounting : SurfaceFinish : Powder CoatedDimension : Dia=170mm,H=40mm |
| 130 | Lights Shine 12 LED Strip lightIndoor Fixture Ingress Protection : 20 Wattage: 15W/MOptics : Opal DiffuserMaterial : AluminiumMounting : SurfaceFinish : Powder coatedDimension : L=1000mm,W=15.40mm,H=6.45mm |
| 131 | Exhaust Fan-300mm dia |
| 132 | Lights ACE36 Batten light Downlighter Indoor Fixture Light Source : ledWattage : 36WIngress Protection : 40Optics : DiffuserCCT : 3000K/4000K/5700KColour Rendering Index : Ra > 80Control Gear : NON-DimmableUGR : <19Rated Life Hours : L70 (50, 000Hrs)Beam angle :DiffusedMaterial : Die-cast Aluminium Mounting : SuefaceFinish : Powder CoatedDimension : L-1190mm,W-30mm,H-40mm |
| 133 | Ceiling Fan-1200 dia as per interior layout |
| 134 | Supply, installation,testing and commissioning of EXIT light Prolite make EVACSAFE Double sided,Self Contained Li Ion BIS approved battery,Rechargeable, Maintained type ,IP 20,LED Exit light with 2.4 W lamp fitting with 3 Hours backup,Directional arrows as required,painted in Epoxy Polyster powder coating,White in colours,complete with all mounting accessories for mounting the fixture,made of CRCA sheet steel,22 SWG,16 to 20 hours Recharging period with constant current charger,Input 230V ,50 Hz,and as per IS 10322 and bIS certified. complete as required. |
| 135 | Supplying Installation, Testing and Commissioning of Circular/ Rectangular/square LED RGB/ RGBWW/ RGBNW/ RGBA/RGBW (as per site requirement) Facade Floodlight/ Projector luminaire for facade lighting with Pressure Die-cast aluminium housing, powder-coated finish, with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, the scale shall be provided for rotation degrees. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection and impact resistance of IK 07. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, undervoltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of5/10/15/20/25/30/40/45/60 degree. Luminaire shouldhave efficacy of minimum 35 lm/W for RGB/RGBNW/ RGBWW/TNW and 65 lm/W for monocolour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. Lifetime of complete luminaire(LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS: (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories, Integral male/female water proof connectors IP 68 etc. as required.The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, RoHS Compliance. |
| 136 | IT NETWORKING & STRUCTURED CABLINGSupply & Installation of CAT 6 information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations up to 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type. (Yellow in Colour for Data) complete as required. |
| 137 | Supply & Installation of CAT 6 information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations up to 250 MHz. Outlets shall be use lead frame technology, non PCB pyramid type. (Blue in Colour for Voice) complete as required. |
| 138 | Supply & Installation of Quad Face Plates along with clearly printed labels and holders complete as required. |
| 139 | Supply & Installation of Triplex Face Plates along with clearly printed labels and holders complete as required. |
| 140 | Supply & Installation of Dual Face Plates along with clearly printed labels and holders complete as required. |
| 141 | Supply & Installation of Single Face Plates along with clearly printed labels and holders complete as required. |
| 142 | Supply & Installation of Cat 6 Mounting Cords 1 meter length for the User End & Rack End Connectivity to the System, Both end shall be RJ 45 with snagless boots. (Yellow in colour for Data) complete as required. |
| 143 | Supply & Installation of Cat 6 Mounting Cords 2 meter length for the User End & Rack End Connectivity to the System, Both end shall be RJ 45 with snagless boots. (Yellow in colour for Data) complete as required. |
| 144 | Supplying and drawing of UTP 4pair Cat6 LAN cable in the exisiting surface /recessed Steel/PVC conduit as requried. 1 run of cable. |
| 145 | Supply & Installation of Cat 6 Patch Panels for accommodating 24 port teMetreination and shall facilitate cross-connection and inter-connection using modular patch cords and shall confoMetre to EIA standard, 19-inch relay rack mounting requirements. Patch Panel shall come with preloaded infoMetreation outlets of non PCB and pyramid type using lead frame technology.Panel shall have label holders and designation labels as part of the standard device.Shall also come with rear cable management metallic tray with velcro ties complete as required. |
| 146 | Supply & Installation of Cat 6 Mounting Cords 1 meter length for the Patch Panel End Connectivity, Both end shall be RJ 45 with snagless boots complete as required. |
| 147 | Supply & Installation of Cat 6 Mounting Cords 2 meter length for the Patch Panel End Connectivity, Both end shall be RJ 45 with snagless boots complete as required. |
| 148 | Supply & Installation of Horizontal Wire Manager front, 1U panel with metal grooves at the back, plastic snap on cover complete as required. |
| 149 | Supply & installation of Cat3 25 Pair Multi Pair cable complete as required. (From Rack to MDF) |
| 150 | Supply & Installation MDF 100 Pair for voice connectivity complete as required. |
| 151 | Supply & Installation MDF 50 Pair for voice connectivity complete as required. |
| 152 | Supply & Installation of Jumper wire Single pair (305m) complete as required. (From MDF to IDF provided by EPABX vendor) |
| 153 | Supply & Installation of 42 U Closed rack with Front Glass door, rear steel door, castors, 2 fans with fan tray, power strips complete as required. |
| 154 | MUSIC SYSTEMSupply,installation, testing and commissioning of following Philips (BOSCH) make Music Accessories / Equipments. Supply, installation, testing and commissioning of complete loud speaker 6W ceiling mounted type , Complete as required with metal grill. |
| 155 | Supply, installation, testing and commissioning of complete loud speaker surface mounted type , Complete as required with metal grill and back mounting box. |
| 156 | Supply, installation, testing and commissioning of complete loud speaker wall mounted type LB1 -U W 06 6 watts cabinet ( Black color) Complete as required |
| 157 | Supply, installation, testing & commissioning of Plena Voice Alarm Controller having features of announcement to 6 Nos zones , built in suitable nos 240W booster amplifiers, emergency microphone on the front panel, 16 priority levels including emergency, music to selected zones can be played, upto 255 messages to be stored in the internal 16MB flash ROM, individual BGM volume control for each zone, Digital pre-recorded messages may be merged, full system supervision, Complete as required (Simliar to Bosch Cat. No. LBB 1990 or equivalent) |
| 158 | Supply, installation, testing & commissioning of Sound BAR array as per site requirement |
| 159 | Supply, installation, testing & commissioning of roof Embede Sound ceiling speaker |
| 160 | Supply, installation, testing & commissioning of CD/MP3/DVD player with AM/FM tuner (Similar to Bosch PLN-DVDT) |
| 161 | Supply, installation, testing & commissioning of Plena Voice Alarm Call Station having gooseneck condenser microphone with 6 zone Selection Keys and an All-Call-Key, PTT Switch, selectable gain, speech filter and limiter for improved intelligibility, LED indication for zone selection, fault and emergncy state, Complete as required (Simliar to Bosch Cat. No. LBB 1956 or equivalent) |
| 162 | Philips Microphone unit |
| 163 | Supply, installation, testing & commissioning of suitable size of equipment rack for above system made out of CRCA sheet to house all the control equipment. Complete as required. |
| 164 | Main Termination Box |
| 165 | Wiring with 2 core 24/.2 mm PVC insulated twisted copper conductor wires in existing conduit/ trunking as required. |
| 166 | Supply, installation, testing and commissioning of Cat 6 Cable. |
| 167 | Supply, installation, testing and commissioning of mixer and priority circuit for overriding system for main system. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer