Tender For Repair To Chajja, Parapet & Roof Treatment In Otm Accn Under Age B/R-I At Chandimandir
Tender Value
35 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
16 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair To Chajja, Parapet & Roof Treatment In Otm Accn Under Age B/R-I At Chandimandir
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick tiles or terracing tiles, pointed in cement mortar alongwith cement screed or plaster and removing rubbish etc outside the MOD land complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed by Engr-in-Charge. |
| 3 | Demolition of un-reinforced cement concrete any description and in any position including sunken portion, roof padding etc not other wise specially provided for and debris so obtained disposing off outside MoD land,complete all as specified and directed. |
| 4 | 50 mm thick (average thickness) PCC 1:2:4, type B-0 (using 12.5 mm graded stone aggregates) as in levelling course, sub base and roof padding, including mixed with WPC complete all as specified and as directed by Engineer-in-Charge.Note : WPC shall be measured and paid for separately. |
| 5 | Rendering 10mm thick rendering in CM 1:4 plaster mixed with water proofing compoound on roof surfaces including junction of parapets etc., and adjoin vertical surface and applying bituminous primer @ 0.40 ltrs per square meter including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid on primed surface by torch application & preparation of surface complete all over as specified and directed.Note: WPC shall be measured and paid for separately |
| 6 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal fae of groove with cement mortar 1:3 complete all as specified and directed. |
| 7 | Preparation of surface of APP membrane of any description, over 10cm in width or girth, not otherwise described and applying two coats of Aluminium paints complete all as specified and directed. |
| 8 | 10-12mm thick multiwall polycarbonate, UV-resistant, light weight, translucent sheet for fixing over Dome including all necessary fittings and fixtures required for fixing complete all as specified and directed.NOTE : (i) Errection of mild steel scaffolding, trestles, ladder, cradles etc necessary for execution of work. (ii) All necessary fittings and fixtures required for fixing of polycarbonate sheet over dome. |
| 9 | Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on water proof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner, complete all as specified and as directed by Engr-in-Charge. |
| 10 | Dismantling of 500 ltrs rotational moulded polythene water storage tanks and settinhg aside as directerd and refixing of same after to carrying out the roof treatment work and also insl cleaning and removing all scale, silt , mud or dirt etc of water tank and including removing and refixing of ball brass valves, complete all as specified and directed. |
| 11 | Dismantling of 1000 ltrs rotational moulded polythene water storage tanks and settinhg aside as directerd and refixing of same after to carrying out the roof treatment work and also insl cleaning and removing all scale, silt , mud or dirt etc of water tank and including removing and refixing of ball brass valves, complete all as specified and directed. |
| 12 | Dismantling of 2000 ltrs rotational moulded polythene water storage tanks and settinhg aside as directerd and refixing of same after to carrying out the roof treatment work and also insl cleaning and removing all scale, silt , mud or dirt etc of water tank and including removing and refixing of ball brass valves, complete all as specified and directed. |
| 13 | 500 ltrs rotational moulded polythene water storage tanks triple layer ( cylinder vertical with closed top) hoisted and fixed in position including 20mm, ball brass valves,high pressure with polythene float and flynut complete screw for iron pipe or brass ferrule all as specified in SSR Part-I complete all as specified and directed. |
| 14 | 1000 ltrs rotational moulded polythene water storage tanks triple layer ( cylinder vertical with closed top) hoisted and fixed in position including 20mm, ball brass valves,high pressure with polythene float and flynut complete screw for iron pipe or brass ferrule all as specified in SSR Part-I, complete all as specified and directed. |
| 15 | 2000 ltrs rotational moulded polythene water storage tanks triple layer ( cylinder vertical with closed top) hoisted and fixed in position including 20mm, ball brass valves,high pressure with polythene float and flynut complete screw for iron pipe or brass ferrule all as specified in SSR Part-I complete all as specified and directed. |
| 16 | Cleaning and removing all scale, silt , mud or dirt from overhead water storage tanks of capacity exc 500 litres but n.exc. 1000 litres and mouths or circulating pipes , complete all as directed. |
| 17 | Cleaning and removing all scale, silt , mud or dirt from overhead water storage tanks of capacity exc 100 litres but n.exc. 2000 litres and mouths or circulating pipes , complete all as directed. |
| 18 | Dismantaling floor hearth or wall tiling/china mosaic including cement mortar bedding (but not backing ) , removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 19 | Glazed ceramic coloured printed tiles in vertical surface of size 450X 350X 7mm thick over & incl 10 mm thick rendering in CM 1:4 for receiving the tiles on verticle surface complete all as specified and directed. |
| 20 | Non-skid Coloured Ceramic tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Providing cement concrete 1:2:4, type B-0 (using 12.5 mm graded aggregates) as in roof kerbs or mud stops, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, gola, kneelers, apex stones, bed plates, kerbs including weathering, slightly rounded or chamfered angles and throating on edges complete all as specified and as directed by Engineer-in-Charge. |
| 22 | Taking up or down PVC/ GI pipe, 15 mm bore with all fittings and connection complete all as specified and as directed by Engineer-in-charge. |
| 23 | 15mm Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors omplete all as specified and directed by Engineer-in-Charge. |
| 24 | Taking up or down PVC/ GI pipe, 20 mm bore with all fittings and connection complete all as specified and as directed by Engineer-in-charge. |
| 25 | Fixing only of 20mm Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 26 | 20mm Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors omplete all as specified and directed by Engineer-in-Charge. |
| 27 | Cutting chases, pinning in, of brick walls or concrete surfaces, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing, etc., and making good, cutting not exceeding 15 cm girth complete all as specified and directed by Engineer-in-Charge. |
| 28 | Vitrified ceramic coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.18Sqm but not exceeding 0.36 Sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 29 | Taking down existing plaster of any description on brick wall/ concrete surface including racking out joints, hacking for key, scrubbing down with water etc. |
| 30 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar, incl facia of rain water pipe height upto 15 m, including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 31 | Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 32 | Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, for partition wall, parapet in balcony and other similar work built in CM (1:4), complete all as specified and directed. |
| 33 | Rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces mixed with water proofing compound as per manufacturer's instruction, finished surface even and smooth without using extra cement complete all as specified and directed. |
| 34 | Supply Only Liquid water proofing compound complete all as specified and as directed by Engineer-in-Charge. |
| 35 | Rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces even and smooth complete all as specified and directed. |
| 36 | Rendering 5 mm thick in cement and sand mortar (1:3) on concrete surfaces (ceiling) finished even and smooth without using extra cement, complete all as specified & directed. |
| 37 | Preparing new plastered surface of walls for applying Two or more coats of 100% exterior Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 38 | Preparing Newly Plastered Surfaces of internal wall and applying two Coats of oil bound distemper over 1 mm thick wall care putty on wall plastered surface complete all as specified and as directed. |
| 39 | Preparation of newly plastered surfaces of ceiling including pilasters,cornics etc and applying applying two Coats of oil bound distemper complete as specified and directed |
| 40 | Prepration of old surface of ceiling and applying one coat of oil bound distemper complete all as specified |
| 41 | Complete removal of existing treatment of surface of walls for applying Two or more coats of 100% exterior Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, complete all as specified and directed. |
| 42 | Prepration of old surface of wall and applying one coat of oil bound distemper complete all as specified |
| 43 | Vitreous china squatting pan \\"orissa\\" pattern, size 580 x 440 mm white, with integral foot rest including 'P' or 'S' trap, flush pipe (excluding flushing cistern) and making good to the floor fixed as in repair complete all as specified & directed by Engineer-in-charge. |
| 44 | Bib taps, brass, fancy type, long body with wall flange, chromium plated, screwed down for iron pipe or for brass ferrule, suitable for 15 mm bore pipe, fixed as in repairs complete all as specified and as directed by Engineer-in-charge. |
| 45 | Two way bib taps, brass (including fixing arrangement of health faucet), fancy type, long body with wall flange, chromium plated with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, suitable for 15 mm bore pipe, fixed in repair, complete all as specified and as directed by Engineer-in-charge. |
| 46 | Vitreous China urinals, half stall type, bedding for urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement incl flush pipe, PVC waste pipe, CP jet and Union for discharge pipe, fixed in repair complete all as specified and directed. |
| 47 | PVC connection 15mm size with PTMT nuts of length 450mm long as in repairs complete all as specified and directed. |
| 48 | Wash hand basin, vitreous china, flat back, white, of size 550 x 400 mm with & including SS waste coupling, angle brackets, PVC waste pipe, as in repairs complete all as specified and as directed by Engineer-in-Charge. |
| 49 | Table top wash hand basin with CP swan neck pillar tap including SS waste coupling, PVC waste pipe as in repairs complete all as specified and as directed by Engineer-in-Charge. |
| 50 | Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed. |
| 51 | Plain Cement concrete type C-2, 1:3:6 (40mm graded crushed stone aggregate) as in sub base, surface channels, drains, hard standing etc complete all as specified and directed. |
| 52 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc complete all as specified and directed. |
| 53 | Pillar taps, cast copper alloy fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, suitable for 15 mm bore pipe, fixed in repair, complete all as specified and as directed by Engineer-in-charge. |
| 54 | Angular stop cock, fancy type, cast copper alloy, chromium plated, screwed down, screwed both ends for iron pipe or for union suitable for 15 mm bore pipe, fixed as in repairs complete all as specified and as directed by Engineer-in-charge. |
| 55 | PVC (SWR) nahani traps/ floor trap 75mm dia with grating including jointing to waste pipe and setting/fixed in cement concrete type B-1 1:2:4 fixed as in repair complete all as specified and directed. |
| 56 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed. |
| 57 | PVC (SWR) pipes single socketed in any length with rubber ring joints of pressure rating 6kgf/cm2 fixed to laid in trenches, floor etc, 75mm bore , complete all as specified and directed.Note : Joint of pipe with RCC slab (in case of floor trap/ 'P' trap shall be water sealed with crack repair component of Dr fixit or equilent agent. |
| 58 | PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls of pressure rating 6 kgf/cm2 fixed complete to walls, suspended ceilings etc., 75mm bore, fixed to walls with MS/GI clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed. Note : Joint of pipe with RCC slab (in case of floor trap/ 'P' trap shall be water sealed with crack repair compounent of Dr fixit or equilent agent. |
| 59 | PVC (SWR) pipes single socketed in any length with rubber ring joints of pressure rating 6kgf/cm2 fixed to laid in trenches, floor etc, 110mm bore , complete all as specified and directed. Note : Joint of pipe with RCC slab (in case of floor trap/ 'P' trap shall be water sealed with crack repair component of Dr fixit or equilent agent. |
| 60 | PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls of pressure rating 6 kgf/cm2 fixed complete to walls, suspended ceilings etc., 110mm bore, fixed to walls with MS/GI clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed. Note : Joint of pipe with RCC slab (in case of floor trap/ 'P' trap shall be water sealed with crack repair compounent of Dr fixit or equilent agent. |
| 61 | 110 mm bore PVC (SWR) of pressure rating 6 kgf/cm2 ) bends of any radius complete all as specified and directed. |
| 62 | PVC (SWR) of pressure rating 6 kgf/cm2 ) Junction (single T) equal or unequal for 110 mm bore pipe, fixed as in repair complete all as specified and directed. |
| 63 | 75 mm bore PVC (SWR) of pressure rating 6 kgf/cm2 ) bends of any radius complete all as specified and directed. |
| 64 | PVC (SWR) of pressure rating 6 kgf/cm2 ) Junction (single T) equal or unequal for 75 mm bore pipe, fixed as in repair complete all as specified and directed. |
| 65 | Taking down and re-fixing in the same opening of Steel rolling shutters after repairing, greasing including replacement of necessary unserviceable lath, spring, shaft, cover, ball bearing, gear etc making it smooth and applying two coats of synthetic enamel paint after preparation of existing painted surface complete all as specified and directed. |
| 66 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified & directed by Engineer-in-charge. |
| 67 | Powder coated Gl frame work grid 605x 605mm for ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and hangers 3mm dia GI (up to 1200mm length )adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia ,40mm long complete all as specified and directed. |
| 68 | 4mm thick non asbestos fibre cement building boards fixed or laid /inserted to timper /GI/Aluminium frame work with screws fixed in ceiling flat or sloping complete all as specified and directed. |
| 69 | PVC lining coloured or selective pattern, as in repair of hollow profile not less than 5mm thick and not less than 250mm wide interlocking type system as in wall/ceiling linings including end and intermediete U or L PVC sections as per manufacturer's instructions including dismantling of existing paneling, complete all as specified and directed(Note : Colour/design and pattern shall be as approved by the GE) |
| 70 | Taking down chowkhats or frame (with shutter w/o taking off shutter from the frame) area not exc 1.5 Sqm each, complete all as specified. |
| 71 | Taking down chowkhats or frame (with shutter w/o taking off shutter from the frame) area exc 1.5 but not exc 4.0)Sqm each, complete all as specified and directed. |
| 72 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons and skirtings etc, laid with any type of mortar, complete all as specified and directed. |
| 73 | 20-22 mm thick machine cut kota stone flooring over cement screed base laid and jointed with neat cement slurry mixed with pigment to match the shade of the slab laid over and incl 20 mm thick bedding layer in cement mortar 1:4 including rubbing, grinding and polishing complete all as specified |
| 74 | 20-22 mm thick machine cut kota stone as in vertical surfaces risers of steps , skirting, dado and pillars etc set and jointed in neat cement slurry and pointed with grey cement mixed with pigment to match the colour of stone slab laid over and including 10 mm thick rendering in cement mortar 1:4 including rubbing and mirror polishing complete all as specified |
| 75 | Granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement-mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and incl 15 mm thick screed bed in CM 1:4, complete all as specified and directed |
| 76 | Powder coated aluminium sections as in frames/ shutter of doors/window/ventilators /partitions, (Sliding / openable/ three track) including joining cleats, glazing clips, rubber neoprene beading, powder coated aluminium snap beading, screws etc. complete all as specified and directedNote : (i) Minimum thickness of power coating shall not be less than 50 micron.(ii) Weight of aluminium section only shall be measured and paid.(iii) Aluminum doors/windows /ventilators to be fixed to jambs with chromium plated screws .(iv) The rate shall be inclusive of neoprene beadings, snap beading, screws etc and in case of sliding shutters locking arrangement and rollers in sliding shutters. Weight of fitting fixtures will not be measured for arriving the weight of aluminum section.(v) Glass /wooden panel/ACP sheet shall be measured and paid separately under respective items.(vi) Design as directed by Engineer in charge. |
| 77 | 4.80mm thick ordinary quality tinted glass, fixed to aluminium frame work in panels not exc 0.5 Sqm in each pane, complete all as specified & directed. |
| 78 | 4mm thick aluminium composite panel sheet (ACP) fixed with aluminium beading with rubber gasket including all necessary clips and fittings colour as approved by Engr-in-Charge all as specified and directed. |
| 79 | Sainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including fixed with stainless steel wire staples complete all as specified & directed. |
| 80 | Repair to old aluminium door/window including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 ,(Excluding aluminium material for shutter frame ) fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, including dismantling & refixing of door if required complete all as specified and directed by Engineer-in-Charge.Note : (i) Glass panes and panels shall be measured & paid separately under respective items (If required). |
| 81 | Mortice lock, verticle type, mild steel, 4 levers, size 100mm, brass body, complete all as specified and directed |
| 82 | Door closer hydraulically regulated designation No-2 universal type of aluminium body fixed to door frames with screws or by welding complete for door shutters of 851 to 1000mm in width, fixed in repair complete all as specified and directed by Engr-in-charge. |
| 83 | 2mm thick fibre glass reinforced translucent plain coloured sheeting with side lap, fixed with coach screws as in roof, wall etc, fixed as in repair complete all as specified and directed. |
| 84 | Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty , fixed in repairs complete all as specified and directed. |
| 85 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, all as directed. |
| 86 | Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 t complete all as specified & directed by Engineer-in-Charge |
| 87 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws incl taking down of existing roof sheet, complete all as specified & directed by Engineer-in-Charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysNov 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender