Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #58167444

Tender For Providing Of 01 X Underground Bunker Of 12 Raj Rif At Mil Stn Naugam Under Ge 969 Ews.

Issued by Statutory Bodies & Commissions/Committees · Kupwara, Jammu and Kashmir
Tender Value
22.89 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
8 days left
EMD
45780
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kupwara → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing Of 01 X Underground Bunker Of 12 Raj Rif At Mil Stn Naugam Under Ge 969 Ews.

BOQ

Name of Work:- PROVN OF 01 X UNDERGROUND BUNKER OF 12 RAJ RIF AT MIL STN NAUGAM UNDER GE 969 EWS.
Sl. No. Item Description
1Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of hard/dense soil, complete all as specified and as directed.
2Removing of excavated soil not exceeding 50m and depositing where directed at a level not exc 1.5 M above the starting point, complete all as specified and as directed.
3M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed.
4M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded agrregate) as in sub base of floors, finished even and fair over well/rammed/compacted earth, complete all as specified and as directed.
5M & L cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and as directed.
6M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory ompaction by using plate vibrator, filling he joints with fine sand and cutting of paver block as per required size and attern, finishing and sweeping extra sand, complete all as specified and as directed.
7Excavation in post holes (or similar holes) in hard/dense soil each n.exc 0.5cum getting out, returing, filling in and raming earth/broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soil, complete all as specified and as directed.
8M&L Plain Cement concrete Type D-2, 1:4:8 (40mm graded aggregate), in foundation, filling and mass concrete, complete all as specified and as directed.
9M&L Plain Cement concrete Type B-2, 1:2:4 (40mm graded aggregate), in foundation, filling and mass concrete, complete all as specified and as directed.
10M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as etc, complete all as specified and as directed.
11Framed brackets of angles or tees, rafter purlins with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
12S&F mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat ections) including distance pieces, cleats etc complete all as specified. Fe 410 Gde -250, complete all as specified and as directed.
13M&L for preparing surfaces of newly or previously untreated steel or iron surfaces of any description over 10 cm in width or girth not otherwise described and apply two coats of sythetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.
14Excavation in trenches n.exc 1.5m wide and 1.5m depth for foundation etc or for shaft well, cesspits etc n.exc on plan and n.exc 1.5m depth and getting out in hard/dense soil, complete all as specified and as directed.
15M&L for PCC 1:3:6, Type C-2 (40mm graded aggregate) as in fdns, filling and mass concrete etc etc, complete all as specified and as directed.
16M & L for walling of radom rubble uncoursed well bonded solidily hearted built in CM 1:4 etc, complete all as specified and as directed.
17M&L for providing cement concrete 1:2:4, Type B-1 (20mm graded aggregate) as in coping etc, complete all as specified and as directed.
18M&L for rendering 15mm thick in cement mortar 1:4 on on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing including finishing to surfaces even and smooth without using extra cement etc, complete all as specified and as directed.
19M&L for extra stone walling for hammer dressing in faces stones of random rubble walling uncoursed fro granite or trap stone etc, complete all as specified and as directed.
20M&L for cement concrete type C2, 1:3:6 (40mm graded aggregate) as in surface channel and drains, complete all as specified and as directed.
21Returning filling in incl spreading leveling, watering and well ramming in layers n exc 25 cm, complete all as specified and as directed.
22Removing of excavated soil not exc 50m and depositing where directed at a level not exc 1.5 M above the starting point, complete all as specified and as directed.
23Extra for forming fair finished drain channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and as directed.
24M&L for providing precast cement concrete type B-1, 1:2:4 (20mm graded aggregate) and set in cement mortar 1:6 in landings, cover slabs (for manholes/ drain cover) etc, complete all as specified and as directed.
25Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed.
26All as per Ser No 25 above but 1.5 m to 3 m deep, complete all as specified and as directed.
27All as per Ser No 25 above but over 3 m deep, complete all as specified and as directed.
28Cement concrete Type C2 1:3:6 (Using 40 mm graded aggregate) in foundations, filling and mass concrete, complete all as specified and as directed.
29RCC Design Mix M-30 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
30RCC Design Mix M-30 as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses all as specified.
31RCC Design Mix M-30 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed.
32RCC Design Mix M-30 as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed.
33RCC Design Mix M-30 as in Columns, pillars, piers,posts and struts, complete all as specified and as directed.
34Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and as directed.
35Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, complete all as specified and as directed.
36Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; exceeding 200mm thick (Horizontal or sloping), complete all as specified and as directed.
37Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and as directed.
38S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
39S&F for Mild steel TMT bars 5 to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
40Roof treatment to concrete surfaces by using EPDM sheet, complete all as specified and as directed.
41Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base, complete all as specified and as directed.
42M&L for 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate), complete all as specified and as directed.
43M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, complete all as specified and as directed.
44M&L for rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in ceiling, complete all as specified and as directed.
45M&L for 03 coats of whitewash on newly plastered surfaces of wall incl preparation, complete all as specified and as directed.
46M&L for 03 coats of whitewash on newly plastered surfaces of ceiling incl preparation, complete all as specified and as directed.
47Removing excavated material exc. 1.50 km but n exc. 5 km and depositing, complete all as specified and as directed.
48S&F Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors or fixed to walls, complete all as specified and as directed.
49S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
50S&F for Plates (plain or chequered) channels or MS Sheets, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and as directed.
51M&L for 100 mm thick cement concrete type C-2, 1:3:6 as in plinth protection, complete all as specified and as directed.
52Brickwork with sub-class 'B' bricks, straight or curved on plan to any radius in half vrick thick walls built in CM 1:4, complete all as specified and as directed.
53Cowls riveted to and including 15cm length of flue pipes, of ditto 250mm dia, complete all as specified and as directed.
54water bars at joints for water percolation proofing of height 150mm, complete all as specified and as directed.
55PVC (SWR) pipes, single socketed, in any length, with rubber rings 75mm dia, complete all as specified and as directed.
56Liquid water proofing compound, complete all as specified and as directed.
57M & L Non-skid ceramic tiles 7 to 8mm thick area of each tiles exc 0.18m and n.exc 0.38 Sqm in floor etc, Incl screed bed 15 mm thick in CM (1:6), complete all as specified and as directed.
58M&L for point wiring for using 1.5 sqmm nominal cross section area copper conductor multistandard PVC unsheathed, FRLS cable in and including using PVC casing caping not less than 25mm size and fittings including PVC box with suitable size of pvc sheet for top cover (ISI marked) fitted with chromium plated steel screws and washer and 1.5 Sqmm nominal cross section area multistandared copper conductors FRLS green PVC insulated unsheathed earth wire and connecting to earth dolly using color code as per IS including terminal boxes suitable for fixing socket and switches, complete all as specified and as directed.
59(a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way
60(b) One 3 pin 5 Amp switch socket outlet on independent board
61(c) One 3 pin 5 Amp switch socket outlet on same board with accessories
62M&L for point wiring for using 2.5 sqmm nominal cross section area copper conductor multistandard PVC unsheathed, FRLS cable in and including using PVC casing caping not less than 25mm size and fittings including PVC box with suitable size of pvc sheet for top cover (ISI marked) fitted with chromium plated steel screws and washer and 2.5 Sqmm nominal cross section area multistandared copper conductors FRLS green PVC insulated unsheathed earth wire and connecting to earth dolly using color code as per IS including terminal boxes suitable for fixing socket and switches, complete all as specified and as directed.
63S&F switch piano Flush type, single pole, one way 5 amp 240 volts, complete all as specified and as directed
64S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed.
65S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type, complete all as specified and as directed.
66S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and as directed.
67Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed.
68S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and as directed.
69S&F in repairs Distribution Board, SPN 4 Way, Double door complete all as specified and as directed
70S & F in repairs MCB,SPN 40-63 Amps 240 Volts B curve, complete all as specified and as directed
71S & F MCB Single pole 6-32A Amps 240 Volts B Curve, complete all as specified and as directed.
72Supply and fix LED Lamp 12 W Inverter type, complete all as specified and as directed.
73Supply and fixing in wall mounted fans 300 mm swing high speed , 230 volts, 50 HZ, AC connecting up including provision of cable from connector to fan, complete all as specified and as directed.
74Supply and fixing LED lights fitting 1x 20W, 220V, AC LED tube light connecting up with flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.
75M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, RFR and removal etc
76Supply ,Laying ,connecting/ Jointing,charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade with stranded aluminum conductor of size 10 sq mm 2 Core, complete all as specified and as directed.
77Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth,for foundations,laying of pipes etc not exceeding 10sqm on plan for mamholes etc and not exceeding 1.5 metre in depth and getting out in Soft/loose soil, complete all as specified and as directed.
78Supply and laying of burnt clay building bricks, sub-classB (old size) Designnation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and as directed.
79M & L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1 Note:-Sand shall be fine sand as specified for plastering. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58167444
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22.89 Lakhs
LAST DATE 10-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of 01 X Underground Bunker Of 12 Raj Rif At Mil Stn Naugam Under Ge 969 Ews.
Basic Detail
Tender No CA NO 969 WS- /2026-27
Bidding Type Tender
Location
City Kupwara
State Jammu and Kashmir
Key Dates
Publish Date 22 Oct 2026
Submission Date 10 Nov 2026
Open Date 12 Nov 2026
Finance
Tender Value 22.89 Lakhs
Tender Fee 500
EMD 45780
Exemption Available
Document List
12f75616-3e2a-4353-96b9-86a9ae962e0d.html
BOQ_891729.xls
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

12f75616-3e2a-4353-96b9-86a9ae962e0d.html

xls

BOQ_891729.xls

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender