Tender For Improvement Of Electrical Installations And Engagement Of Electrical Wireman And Electric Beldar For Day To Day Electrical Maintenance At Tb Hospital Nehru Nagar In Ward No. 144 Under Central Zone.
Tender Value
13.33 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
5 days left
EMD
28000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement Of Electrical Installations And Engagement Of Electrical Wireman And Electric Beldar For Day To Day Electrical Maintenance At Tb Hospital Nehru Nagar In Ward No. 144 Under Central Zone.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C |
| 2 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm |
| 3 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 4 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 6 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C |
| 7 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 8 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 9 | S.P. 15/16 A, one way modular switch, ISI marked |
| 10 | 3 pin 5/6 A modular socket outlet, ISI marked |
| 11 | 6 pin 15/16 A modular socket outlet, ISI marked |
| 12 | S.P. 5/6 A, one way modular switch, ISI marked |
| 13 | 25 mm diA, ISI marked, PVC conduit |
| 14 | Stepped type Modular Fan regulator (2 module) |
| 15 | 20 A, SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure |
| 16 | 8 way, SPN, double door, MCB DB |
| 17 | 12 way, SPN, double door, MCB DB |
| 18 | 6 A, to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 19 | 63 A, 2 pole isolator |
| 20 | 63 A, 4 pole isolator |
| 21 | 4 pole MCCB,100A,30kA Ics=100% Icu and Operational Voltage 690V |
| 22 | 4 pole MCCB, 200A, 36kA Ics=100% Icu and Operational Voltage 690V |
| 23 | Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as reqd. |
| 24 | Supply of 10\\" (250mm) sweep 1250 rpm exhaust fan Fresh Air type complete with shutter ,blades etc as required |
| 25 | Supply of LED Tube type Luminaire 20W rating complete with polycorbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following: (a) Total System wattage 20 watt +/- 5% (b) Luminous Efficacy Lumens/watt >=95 (c) power factor >= 0.95 |
| 26 | Providing following Skilled/Unskilled Labour for day to day Electrical maintenance works at TB Hospital Nehru Nagar (a) Wireman 01 no. |
| 27 | Providing following Skilled/Unskilled Labour for day to day Electrical maintenance works at TB Hospital Nehru Nagar. (b) Electric Beldar 01 no. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender