Tender For Construction For Chief Office Pwd(R&B) Department Rajouri
Tender Value
7.44 Crore
Estimated cost
Bid Submission
12 Nov 2026
10 days left
EMD
14.89 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction For Chief Office Pwd(R&B) Department Rajouri
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-Oct-2026 | Correction | Other | 12-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 2 | Demolishing cement concrete 1:3:6 or richer mix (i/c equivalent design mix) manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge. |
| 3 | Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:In cement mortar |
| 4 | Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:In cement mortar |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead Of area beyond 3 sqm. |
| 6 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. |
| 7 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. |
| 8 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of :G.S. Sheet |
| 9 | Surface dressing of the ground including removing vegetation and in-equalitites not exceeding 15cm deep and disposal of rubbish, lead upto 50 and lift upto 1.5m in all kind of soil. |
| 10 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 11 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge in all kind of soil. |
| 12 | Extra for every additional lift of 1.5 M or part therefore in all kinds of soil. |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate) 40mm nominal size crushed. |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 15 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as perapproved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level. |
| 16 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as perapproved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.All works above plinth level upto floor V level. |
| 17 | Providing and laying in position 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Cold twisted bars |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form work for :- |
| 21 | Foundations, footings, bases of columns etc. For mass concrete. |
| 22 | Column, Pillars, Piers, Abutments, Posts and Struts. |
| 23 | Lintel, beams, plinth beam, girders, bressumers and cantilevers. |
| 24 | Suspended floors, roofs, landings, balconies and access platforms. |
| 25 | Weather shades, chajjas, corbels etc. including edges. |
| 26 | Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc. |
| 27 | Stairs (excluding landings) except spiral stair cases. |
| 28 | Providing and laying DPC 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and curing complete. |
| 29 | Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 30 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 fine sand).(Below Plinth) |
| 31 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:6 (1 cement : 6 fine sand). |
| 32 | Extra for brick work in super structure above plinth level upto floor V-level. |
| 33 | Half brick masonry with bricks of class designation 75 in foundation, plinth and superstructure upto floor V-level in cement mortar 1:4 (1 cement : 4 coarse sand). |
| 34 | Extra for half brick work in super structure above plinth level upto floor v-level. |
| 35 | Extra for providing and placing in position 2 Nos 6mm dia M.S Bars at every third course of half brick masonary. |
| 36 | Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement: 3 fine sand) including curing upto Plinth Level and above plinth level upto floor V level. |
| 37 | 6mm Cement Plaster to Ceiling of Mix 1:3(1 Cement:3 Fine Sand) |
| 38 | 12mm Cement Plaster of Mix 1:6 (1 Cement :6 Fine Sand) |
| 39 | 15mm Cement Plaster on the rough side of single or half brick wall of Mix 1:6 ( 1 Cement: 6 Fine Sand) |
| 40 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M. |
| 41 | Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidationg and dressing complete. |
| 42 | Making of grove 12mm x 10mm between brick and RCC. |
| 43 | Making plinth protection 50mm thick cement concrete 1:3:6 (1 cement : 3 course sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth crushed. |
| 44 | Brick edging 7 cm wide 11.4cm deep to plinth protection with bricks of class designation 75mm including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 45 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc. (Make Armocreate of SWC Chryso France) consisting of (a) applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining was upto 300mm height including rounding of junction of walls and slaps.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (iv) Finishing the surface with 20mm thick joint less cement mortar of mix 1: 4 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fiber cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm / sq 3mm deep. (e) The whole terrace so finished shall be flooded with water far a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer-in-charge. With average thickness of 120mm and minimum thickness at khurras as 65mm |
| 46 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 47 | Providing and laying water proofing treatment (Make Armocreate of SWC Chryso France) to vertical and horizontal surface of depressed portions of W.C., kitchen and the consisting of (i) Ist course of applying cement slurry @ 4.4 kg /sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding of junctions of vertical and horizontal surface. (ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions including rounding of junctions of vertical and horizontal surface. (iii) III course of applying blown or / residual bitumen applied hot at 1.7 kg per sqm of area. (iv) Ivth course of 400 micron thick PVC sheet (Overlaps at joints of PVC sheet should be 100mm wide and pasted to each other with bitumen @ 1.7 kg/sqm. |
| 48 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size below flooring, retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing. |
| 49 | Providing and laying vitrified floor tiles in Size of tile 600x1200 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete |
| 50 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 51 | Providing and laying 18mm thick Granite of any colour and shape (area of slab over 0.5 Sqm) gang saw cut mirror polished (pre moulded and pre polished), machine cut for kitchen platform, vanity counters window sills facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 52 | Extra for providing edge moulding to 18/16 mm thick Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. |
| 53 | Extra for providing opening of required size and shape for wash basins/kitchen sink in kitchen platform, vanity counters and similar location in marble / stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. |
| 54 | Providing and laying Ceramic glazed floor tiles ( Mat finish ) (Non-Skid) 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown. |
| 55 | Providing and fixing Ist quality ceramic glazed wall tiles 300X600mm conforming to IS : 13753 of minimum thickness 5mm of approved make like or equivalent make in all colour, shades except burgundy, bottle green, black of any size as approved by Engineer in charge over 12mm thick bed of cement mortar 1:3 (1cement : 3coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 56 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc with all necessary Acessories and fittings complete job. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. a. Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm &mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqmu pto 5.00 sqm). |
| 57 | Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed/ ACP door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinderwith keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water et cwith all necessary Acessories and fittings complete job. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. a. Casement door with 3D hinges made of (big series) frame 67 x 64mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). |
| 58 | Providing and fixing of glass panes weighing 12.50 kg/sqm (5.0mm thick) with deodar wood fillets. |
| 59 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) |
| 60 | For fixed portion.Powder coated aluminum (minimum thickness of powder coated 50 microns). |
| 61 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 62 | Providing and fixing of 3mm thick + 0.5% ACP aluminium sheet on Door/ Window shutter in white/ Ivory colour with water resistant and termite proof along with all necessary fitting complete job as per the Direction/ Engineer-in- charge. |
| 63 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.)With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg / sqm) |
| 64 | Providing and fixing of aluminium beading. |
| 65 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body /plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin- plate etc. complete as per the direction of Engineer-in-charge.With Stainless Steel cover plate minimum 1.25 mm thickness. |
| 66 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 67 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge.Powder coated minimum thickness 50 micron aluminum tabular handle bar |
| 68 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :Twin rubber stopper |
| 69 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 70 | 150X10mm |
| 71 | 100X10mm |
| 72 | Providing and fixing bright/ matt finished stainless Steel handles of approved quality & make with necessary screws etc. All complete |
| 73 | 125MM |
| 74 | 100MM |
| 75 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete : |
| 76 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 110mm diameter. |
| 77 | Providing and fixing on wall face unplasticised-PVC moulded fitting / accessories for unplasticised- rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion :- |
| 78 | COUPLER 110mm |
| 79 | SINGLE TEE WITH DOOR 110X100X110mm |
| 80 | BEND 87.5X110mm |
| 81 | Providing and fixing un-plasticised -PVC pipe clips of approved design to un-plasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 82 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. |
| 83 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. Tube |
| 84 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M- 6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. |
| 85 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide x 1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45 x15 x 0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm dia X 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board /calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
| 86 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 87 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacture,over the plasterted wall surface to prepare the surface even and smooth complete |
| 88 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 89 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 90 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 91 | Providing and fixing factory made teracotta jali of approved design pattern, and size manufactured from high- quality natural teracotta clay, baked at high temperature to ensure durability and weather with smooth finish and uniform color, the jali shall be fixed in position over a suitable mild steel frame or RCC opening using cement mortar 1:4 ( 1cement ; 4 coarse sand) including all cutting shapping, allignment, scaffloding curing and finishing the joints flush with adjacent surfaces complete in all respects as per drawings and instruction of Engineer -in-charge, complete job. |
| 92 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per the direction of Engineer-in-charge. |
| 93 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 94 | Providing, making, and installing 3D fabricated stainless-steel letters made from SS 304 grade, minimum 1.2–1.5 mm thickness, with mirror-polished finish. Letters shall include integrated LED backlit illumination (cool white or as approved), complete with acrylic backing, LED modules, wiring, power supply/driver, and necessary heat dissipation arrangements. |
| 95 | Providing & Fixing of p.v.c sheet signages &bond in front of every Accomodation / Room fix with s.s. screw. |
| 96 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes . |
| 97 | Providing and fixing 5mm thick transparent acrylic sheet of approved brand, colour and shade, including cutting to required size, edge polishing, drilling bending whereever required, complete with all acessories and fittings such as aluminium/ SS brackets, screws, nuts and bolts, washers, rubber beading, spacers, silicon sealent cleats support system complete in all respects as per approved design and direction of Engineer- in-charge |
| 98 | Painting with synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new work (steel work). |
| 99 | Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.)with grass turf . |
| 100 | Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment) |
| 101 | Supplying and stacking at site dump manure from approved source including carriage complete (manure measured in stacks will be reduced by 8% for payment)Screened through sieve of I.S. designation 4.75 mm . |
| 102 | Fine dressing of the ground. |
| 103 | Mixing earth and sludge or manure in proportion specified or directed by officer in charge. |
| 104 | Provision for trees at height of 6ft of Green Bottle Palm Tree, |
| 105 | Finishing walls with water proofing cement paint of required shade on new works (two or more coats applied @3.84kg/10sqm. |
| 106 | Providing and fixing 4mm thick Aluminium Composite Panel(ACP) cladding comprising 0.50mm thick aluminium skin on both sides with FR/LDPE core, PVDF coated exterior grade finish, fixed on aluminium sub-frame using approved brackets, fasteners rivets, cleats, sealnt, edge trimming and all acessories complete as per drawing and direction of engineer -in- charge. (make ;- Aldestone, Greenlam etc) |
| 107 | Providing and fixing water closet squatting pan (Indian type W.C. pan) (Essel Cat No-75013010 / Kerovit Cat No- KS606 / CERA CAT NO- S3010101) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern (Essel Cat No- 402101 / Kervoit Cat No- KO1005 / CERA CAT NO- B1010110), including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.(MAKE:- Kerovit, Essel, CERA, Hindware) |
| 108 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) (Essel Cat No-76031011 / Kerovit Cat No- KS112 / CERA CAT NO- S1053121) with seat and lid, 10 liter low level white P.V.C. flushing cistern (Essel Cat No- 402101 / Kervoit Cat No- KO1005 / CERA CAT NO- B1010110), including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 109 | Providing and fixing complete set of sanitary fixtures for handicapped toilets, CERA CRUSE SET ) comprising of EWC 710X370X770MM, , Cistern, Seat Cover, Twin Flush Fittings, Wash Basin 665X545X190MM, l, 1 faucet with spatula lever, 1 hinged rail and 1 grab bars, including cutting and making good the walls and floors wherever required complete as per directions of Engineer in charge. CERA, Hindware) |
| 110 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin (Essel Cat No-73011020 / Kerovit Cat No- KS505 / CERA CAT NO- S4020103) of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Range of two urinal basins with 5 literwhite P.V.C automatic flushing cistern. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 111 | Providing and fixing wash basin (Essel Cat No-72001140 / Kerovit Cat No- KS234 / CERA CAT NO- S2040120) with C.I. brackets, 15 mm dia CP Brass single hole basin mixer (Essel Cat No-113001 / Kerovit Cat No- KB1311010 / CERA CAT NO- F1020451) of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 112 | Providing and fixing white vitreous china pedestal (Essel Cat No-72011071 / Kerovit Cat No- 305 / CERA CAT NO- S2090113) for wash basin completely recessed at the back for the reception of pipes and fittings. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 113 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 114 | Providing and fixing of C.P. brass Central Hole Basin Mixer/ Table top Mixer without Popup Waste System (Essel Cat No 113001 / Kerovit Cat No.KB2111010 & CERA CAT NO- F1020451 ). including with 450mm Long Copper Pipes & Brass Nuts with all fittings and accessories as per direction of Engineer-Incharge. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 115 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 116 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 117 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 118 | Providing and fixing 15 mm nominal bore C.P. brass angle valve (Essel Cat No 113052, Kerovit Cat No- KB2111003 & CERA CAT NO- F1023201) for basin mixer and geyser points or wherever required as per the direction of Engineer Incharge of approved make conforming to IS : 8931. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 119 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge.(MAKE:- Kerovit, Essel, CERA, Hindware) |
| 120 | Providing & fixing C.P. hand spray with lever control (health faucet) (ESSEL CAT NO- 309004, Kerovit CAT NO- KA580007 & CERA CAT NO- F8030106AB) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 121 | Providing and fixing P.V.C. waste pipe for sink or wash basin (ESSEL CAT NO- 301206) including P.V.C waste fittings complete: 18.28.2 Flexible pipe. 40 mm dia (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 122 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: 18.69.1 Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 123 | Providing and fixing CP Brass 32mm size Bottle Trap (ESSEL CAT NO- 301307, KERVIT CAT NO- KA870001 & CERA CAT NO- F8060404AB) of approved quality & make and as per the direction of Engineer-in-charge. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 124 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 125 | Providing & fixing C.P. brass robe hook (ESSEL Cat No. 114026 ,Kerovit Cat No. KA980003 & CERA CAT NO- F5003108) or approved equivalent) fixed to wall/door with plastic rawl plugs and C.P brass screws including cutting and making good the walls wherever required as per direction of Engineer-Incharge. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 126 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 127 | Providing and fixing16mm/18mm stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth. White Agaria Marble Stone |
| 128 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.or wherever required as per the direction of Engineer Incharge. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 129 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 130 | Providing and fixing Plane floor trap with heavy class SS grating and setting in floor with cement mortar to match the floor finish as per direction of Engineer-in-charge (size 100 X 75mm mm dia) ISI marked. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 131 | Providing & fixing storage type water cooler with plain & cold water facility of the following capacity, I.S.I marked, stainless steel front panel, C.P brass push cock, inlet float valve with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection to F.D complete as required (Blue Star or equivalent). |
| 132 | Cooling capacity 20 Ltrs./hr (Model No. Bluestar PC240) Storage capacity 40 Ltrs. |
| 133 | Providing & fixing commercial 20 LPH water purifier of required capacity 8 LTR. Including all components as per manufacture specifications, including connection from water supply line, and final connection to water cooler electric wiring & plug top etc. with all accessories.(MAKE:- KENT GRAND, AQUAGUARD, OR EQUIVALENT) |
| 134 | Providing, storing, handling, shifting, installation, testing & commissioning of vertical / horizontal storage type hot water heater fixed to wall with anchor bolts & nuts, 20mm CP brass cock and 20mm non return valve complete including making connection with 15 mm dia CP connecting pipe on Inlet and Outlet, suitable length of power cable and 15A plough (for pantry & Toilets). (Make : Hindware, Bajaj or equivalent) |
| 135 | Capacity 10 liters |
| 136 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (MAKE:- Kerovit, Essel, CERA, Hindware) |
| 137 | Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-AL-PE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge:( Make : Astral, Kitec, Vista, Prayag, Supreme,) |
| 138 | Internal work concealed with clamps at 1.00 meter spacing including cutting the chases and making good the wall etc., C |
| 139 | 1216 (16mm OD) pipe. |
| 140 | 1620 (20mm OD) pipe. |
| 141 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. Including with all Necessary fittings & Acessories Complete job. Make ( Make :Astral, Kitec, Vista, Gebrat Prayag, Supreme,) |
| 142 | 15 mm dia. nominal bore (Medium) |
| 143 | 20 mm dia. nominal bore (Medium) |
| 144 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etcIncluding with all Necessary fittings & Acessories Complete job.Make (External work) |
| 145 | 25 mm dia. nominal bore (Medium) |
| 146 | 32 mm dia. nominal bore (Medium) |
| 147 | 40 mm dia. nominal bore (Medium) |
| 148 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete copatable to connection with composite pipe |
| 149 | 15 mm nominal bore |
| 150 | 20 mm nominal bore |
| 151 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 152 | 25 mm dia. nominal bore |
| 153 | 32 mm dia. nominal bore |
| 154 | 40 mm dia. nominal bore |
| 155 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. |
| 156 | 15 mm dia. nominal bore (Medium) |
| 157 | 20 mm dia. nominal bore (Medium) |
| 158 | 25 mm dia. nominal bore (Medium) |
| 159 | 32 mm dia. nominal bore (Medium) |
| 160 | 40mm dia. nominal bore (Medium) |
| 161 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete |
| 162 | 25 to 40 mm nominal bore |
| 163 | Earthwork in all kinds of soil excavation by manual means in trenches for foundations, drains, pipes, cable etc. (not exceeding 1.5 in width) and for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to be levelled and neatly dressed. |
| 164 | Providing and fixing on wall face unplasticised-Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion.(Make :- Astral, Prayag, Prince and Jain) with. All necessary fittings and Accessories as per the Direction of Engineer Incharge. |
| 165 | 75MM dia |
| 166 | 110MM dia |
| 167 | 150MM dia |
| 168 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 455x610 mm and 45 cm deep for single pipe line- |
| 169 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 600x 850 mm and 45 cm deep for single pipe line with three or more inlets. |
| 170 | Providing and fixing 100 mm sand cast iron grating for gully trap. |
| 171 | Providing and fixing heavy class SS grating plane including setting in floor with cement motor to match with floor finish as per direction of Engineer-Incharge (Size 100 mm dia) (ISI Marked) |
| 172 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex, Electroplast, star, Lotous or equivalent having valid ISI license) (1000 ltr. Capacity.). |
| 173 | Supply, assembly, erection, testing and commissioning of pumping system comprising the following: |
| 174 | Vertical/Horizontal centrifugal pumps with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, Single phase, 50 cycles A.C. supply with 65/ 65 mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump) (Make:- Crompton,Wilo, Ebara and Matherplatt etc.) |
| 175 | 15, Capacity 3 H.P, Suction -65mm x Delivery 65mm (Domestic water relift pump). |
| 176 | Design, Supply, Installation, Testing and Commissioning of one No. 08 passenger (544 kg) Stainless Steel moon light finish/ hair line finish/ moon rock finish Elevator of machine room less type with following specifications: |
| 177 | Make: ThyssenKrupp/ Kone/ OTIS/ Mitsubishi/ Fujitec India/ Schindler/ Hitachi. |
| 178 | Operation/Control: Microprocessor based simplex selective Collective with / without attendant. |
| 179 | Travel: 3 stops & 3 openings (G+2) |
| 180 | Speed: 1 m/s |
| 181 | Bottom Pit Depth: 1600 mm (approx) |
| 182 | Controller: Micro-Processer based AC variable voltage & variable frequency drive (AC VVVF) |
| 183 | Car/Doors: Stainless Steel Scratch proof with hair line finish with fire rating and side opening doors. |
| 184 | Door opening: 800 mm (width) x 2000mm (height) with fire rating as per recommended norms. |
| 185 | Machine: Gearless type. |
| 186 | Car size: 1100mm (wide) x 1300mm(deep)x 2200mm (high) |
| 187 | Hoist way/Lift Well Size: |
| 188 | Available: 1850 mm(wide)x 1650 mm(deep) |
| 189 | Leveling: A separate level device for automatic leveling with leveling accuracy of ± 2 mm shall be incorporated |
| 190 | Power Supply: 415 ± 1 % volts, 3 phase, 50 Hz |
| 191 | Accessories: Automatic Rescue device (ARD), During event of power failure or blackout in building, this device automatically moves and stops at the nearest floor or door then open to ensure any onboard passenger safety. |
| 192 | Digital LED displays, Alarm should be battery operated, automatic operation for car fan, adjustable door open time, anti-nuisance (empty car), anti-nuisance (car call cancellation at direction reversal), blower fan in car for ventilation, braille on push buttons, VF regenerative (closed loop), traction media: coated steel belt/roop, door closing retries, door nudging, emergency light, infra-red screen for car door, Intercom, Jammed landing operating panel call button by-pass, motor overheat protection, overload function with audio-visual indication in car operating panel, phase failure and phase reversal protection, attendant control, fireman control, fireman emergency return, lift announcement system. |
| 193 | Car Enclosure: Constructed out of Stainless-Steel hairline scratch proof finish. |
| 194 | Flooring: Platform lined with anti-skid flooring. |
| 195 | Lighting & Electric work : Job includes providing and fitting of 10W LED Bulk Head Fitting and 16 A Power Socket at every 10 ft throughout the shaft. Ceiling fan, exhaust fan and lighting in control room along with Required Size of Distribution Board and Incomer,Outgoing MCb's. |
| 196 | Civil Work: Job includes all kind of minor civil works required for installation of lift. Cleaning of site/debris before and after execution of work. |
| 197 | Supply Cable: Providing, laying, testing and commissioning of aluminium armored cable PVC insulated 50m(approx.) length of suitable size as per the recommendation of lift manufacturer confirming to relevant IS code 7098 Part-1 with Latest amendment up to date of some standard ISI mark from main electric panel to lift control room at top level. Complete job including labour, taxes, transportation etc. |
| 198 | Earthing:- Suitable chemical earthing to the lift motor & panel by way of excavation of pit of proper size upto a depth of 03 meter, copper electrode in hard and soft soil followed by filling of required quantity of earthing chemical for each electrode. Job includes filling of pit with excavated soil and fitment of copper electrode with copper strips.(02 Nos) |
| 199 | Any work/items not mentioned in the scope of work but deemed necessary for completion and commissioning of this project shall deemed to be included in the scope of work.Job on Turnkey Basis. |
| 200 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq. mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 Sq. mmFRLS PVC insulated copper conductor single core cable etc. as required. |
| 201 | Group A |
| 202 | Wiring for Light /Power Plug with 2 x 4 Sq. mmFRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 Sq. mmFRLS PVC Insulated copper conductor single core cable for loop earthing as required. |
| 203 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 204 | 1 x 1.5 sq. mm |
| 205 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/ Recessed medium class PVC conduit as required. |
| 206 | 2 X 2.5 Sq. mm+ 1 X 2.5 Sq. mmEarth Wire |
| 207 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 208 | 4 X 16.0 Sq. mm+ 2 X 6.0 Sq. mmEarth Wire |
| 209 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required |
| 210 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 211 | 25 mm |
| 212 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 213 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 214 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 215 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 216 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as equired.(For Geyser and A.C ) |
| 217 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 218 | 4 way (4 + 12), Double door |
| 219 | 6 way (4 + 18), Double door |
| 220 | 8 way (4 + 24), Double door |
| 221 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 222 | Single Pole |
| 223 | Single pole and neutral |
| 224 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.Bin the existing MCB DB complete with connections, testing andcommissioning etc. as required. |
| 225 | 32 A F.P MCB 10 Ka \\"C\\" Curve |
| 226 | 63 A F.P MCB 10 Ka \\"C\\" Curve |
| 227 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 228 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80, under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 229 | 150 watt |
| 230 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)Powder coated die cast /Extruded aluminum Body including trim |
| 231 | Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) |
| 232 | 40 watt |
| 233 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 Sq. mmFR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 234 | 1200 MM |
| 235 | LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) |
| 236 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3 , Maximum powerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testingrequired for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal anagement: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 237 | 36 watt |
| 238 | Supply installation testing and commissioning of IP:20 Decorative Mirror Light 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 239 | Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of Metal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required . |
| 240 | Supply installation testing and commissioning of IP65 led Bulk head 10 W +/- 1 W LED Surface Pressure Die Cast Aluminum system lumen efficacy of 100 lm/W with Polycarbonate Opal Diffuer and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80, IK rating IK08. The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 265V. The Fixture should have In-built Surge Protection of 2.5kV Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab . |
| 241 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)Powder coated die cast /Extruded aluminum Body including trim |
| 242 | 18 watt |
| 243 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 244 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 245 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 246 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sandcushioning and protective covering etc., complete as required. |
| 247 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 248 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 249 | 3.5 C X 25 Sq.mm A2XFY |
| 250 | 3.5 C X 300 Sq.mm A2XFY |
| 251 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 252 | 3½ X 25 sq. mm (28mm) |
| 253 | 3½ X 300 sq. mm (70mm) |
| 254 | Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description. (IP:42) ( Building Distribution Panel ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD |
| 255 | Adj. TMR Based MCCB 200 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH |
| 256 | Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH |
| 257 | 100 A,415 Volts 50Hz Aluminium Busbar set of 4 strips |
| 258 | 300 A,415 Volts 50Hz Aluminium Busbar set of 4 strips |
| 259 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 260 | Manual Changeover Switch 63 A F.P 415 Volts with AC-23 Duty |
| 261 | Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH |
| 262 | MCB 63 A F.P \\"C\\" Curve 10 Ka |
| 263 | MCB 32 A F.P \\"C\\" Curve 10 Ka |
| 264 | Load Bearing Members to be made out of 2.0 mm CRCA Sheet. |
| 265 | Partitions to be made out of 1.6 mm CRCA Sheet |
| 266 | Gland Plates to be 3.0 mm Thick. |
| 267 | Supply installation testing and commissioning of 2.2 KVA Sine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery. |
| 268 | Providing of following size of Under Floor Trunking (Make: Legrand) of following items including accessories as required. |
| 269 | M Track 300 mm x 38 mm x 1.6 mm- 3 compartment |
| 270 | Junction Box Top recess-8mm with Metallic Lid,Height 55-70 mm(350 x 350 mm) |
| 271 | Access Outlet 300 x 300 x 60-75mm 3 comp. |
| 272 | Supply and Fixing of Desking Module 8M |
| 273 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 274 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 275 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 276 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 46 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).The Rate of Stabilizer with Voltage Ranging 90 V -240 V Required for the item should be included in the Rate of the Hi wall Split A.C. |
| 277 | Inverter Type - Cooling only |
| 278 | 1.5 TR with 5 Star BEE Rating |
| 279 | Supply, Installation, testing and commissioning including vaccumiazationand Nitrogen testing of following nominal sizes of soft/hard drawn copperrefrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : |
| 280 | 15.9 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 281 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 282 | Providing & fixing control wiring of 2 core x 1.5sqmm copper in PVC conduit pipe of 25mm dia including providing & fixing support @1.5mt distance CIC where it is not recessed between indoor units and out door units |
| 283 | 25mm dia |
| 284 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card,minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. Thepanel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 285 | Two Loop Panel. |
| 286 | Supplying, installation, testing & commissioning of intelligentanalog addressable photothermal detector complete withmounting base complete as required. |
| 287 | Supplying, installation, testing & commissioning of intelligentaddressable thermal detctorwith rateof rise cumfixed temperature thermistor complete with base as required. |
| 288 | Supplying, installation, testing & commisssioning ofintelligent addressable programmable sounder complete asrequired. |
| 289 | Supplying, installation, testing & commissioning of faultisolator complete with base as required. |
| 290 | Supplying, installation, testing & commissioning ofaddressable manual call point complete as required. |
| 291 | Supplying and drawing Fire resistant flexible/strandedbare copper conducto, PVC /XLPE insulated, overall aluminium mylar tape shielded ATC drain wire andouterPVC sheathed industrail instrumentation (shielded) cables volatge grade 300/500 Vas per BS/EN 50288-7 in existing surfaceor recessed PVC/ MSconduit/casting capping/ cabletray / open Duct mal\king connections, testing etc. as required OEM musthave its ownin house NABL labsetup for all testing facilities for cables. |
| 292 | 2x1.5sq.mm Armoured with Sheath in Red color |
| 293 | TOTAL (A) |
| 294 | Providing, layiny classheavy duty MS pipe conformingto is 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 295 | 25 mm dia |
| 296 | 80mm dia |
| 297 | 100 mm dia |
| 298 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as require |
| 299 | Single headed Gunmetal |
| 300 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 301 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required |
| 302 | Gun Metal |
| 303 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.:20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 304 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required |
| 305 | 2 way-100 mm dia M.S. Pipe |
| 306 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.: |
| 307 | Providing and Placing on terrace(at all floor levels) polyethylenewater storage tankc IS:12701 marked, with coverand suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and thebase support for tank |
| 308 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: |
| 309 | Gun Metal |
| 310 | Providing , installationtesting and commissiioning of fire Hose Cabinet having front door (s) withviewing glass, single or double opening with necessary locking arrangement suitable for housing 2 nos. hose pipe, 1 no Branch pipe and hydrant valve (Placing of hydrant in hose cabinet valve isn subjected to site feasibility).the cabinet design shall be reviewed and approved by the Site Engineer before installation |
| 311 | Providing andfixing standard fireman's axe with heavy insulated rubber handle conforming IS:926 Complete |
| 312 | Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impellerwith stainless steel shaft, mechanical confoirming to IS: 1520b)Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class- 'F' insulation, conforming to IS-325 (c)M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 313 | 450 lpm at 35 m head |
| 314 | Supplying, installation, Testing and Commissioning of Cubical Type outdoor Ltpanel Board Suitable for 415 V 3 Phase 4 Wire 50Hz Ac supply System inculding incomers, out Goings, Bus Bars Etc.. Asrequired as per the following Description. (Ip:55) ( Terrace Panel) The successful tenderer Shall take prior approval for the panel builder/ fabricator along with G.A drawing, wiring diagrams single line diagram before start of fabricationof LT panel. Circuits breaker shall be capable of carrying the full load current defined for 50 degree celsius without any derating. The Panel Builder shall be CPRI/ERDA/ANY NABL ACCREDITED LAb Approved |
| 315 | MCCB 63 A F. P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable roh Icu=v Ics=100% |
| 316 | DigitalMetering Devices comprisingVoltmeter Ammeter, selector Switch, Indicating Lamps C.T Set, Bus Bar( 80 Amps) AndMCB Strip of suitable size as Required |
| 317 | MPCB 19-25 A WITH STD Magnetic Release |
| 318 | Power Contactor 40A415 Volts, AC-3 Duty |
| 319 | Start/ Stop Push Button |
| 320 | Size of wiring for CTS:- 2.5 Sqmm |
| 321 | Size of wiring for voltage sensing Metering :- 4.0 Sq.mm |
| 322 | Size ofwiring of all pushbuttons, indicating lamps:- 1.5 sq.mm |
| 323 | Types of wire: PVC Insulated 1100V grade, Multistrand copper conductor Flexible FR-LSH |
| 324 | Hinged DoorEarthing:- Device mounted hinged doors connected tocubical body by means of2.5 sqmm. Green copper flexible wire. |
| 325 | The Complete Panel Shall Be made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc. |
| 326 | Gland Plates to be 3.0 mm Thick |
| 327 | 25 Sq mm, 3 Core Aluminium armoured cable |
| 328 | 16 Sq mm single core copper inulated Cable |
| 329 | Supplying, Laying testing and commissioning of 6 sq.mm green insulated copper earth wire from the building earth bus to the Fire Pump Motor and fire pump control Panel, Complete with complete with copper lugs, glands, Clamps, Ferrules, termination, testing and commissioning conforming to IS 3043 CPWD General specification for electrical Works and as per manufacture's recommendation, complete as required |
| 330 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 331 | 100 mm dia |
| 332 | 80mm dia |
| 333 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 334 | 100 mm dia |
| 335 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 336 | 100 mm dia |
| 337 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 338 | Providing installation testing and commisioning of pressure Guages for fire pumps/ checking of line pressure |
| 339 | Supplying , installation, Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg.. Capacity ISI Mark (IS : 15683) Suitable for \\"B\\" and \\"C\\" class fires inflammable liquids, gaseous fire like L.P.G and acetyiene and electrical fires |
| 340 | Supplying,Installation,Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark(IS:15683)suitable for Class A/B/C Type Fires . |
| 341 | Providing,Fabricating supplying and fixing fire safety signage conforming to NBC 2016 Part 4 and relevant IS/ISO strandards, inculding photoluminescent emergency exit signs, fire extinguisher signs, fire hose reel sign, fire hydrant signs, manual call point signs, fire alarm sign, exit direction signs, staircase identification sign, assembly point signs,\\" Do Not Use Lift in Case of Fire:\\"Sign \\"No Smoking\\" Sign, evacuation plan boards, and other statutory fire and lift safety signages. The Work Shall inculde high- quality reflective/photoluminescent material, aluminium composite panel(ACP)/rigid PVC backing,digital priting or screen priting, mounting hardware, fixing accesories, drilling, installation at approved locations, testing and all labour, material, tools, transportation, and incidental works complete as directed by the Engineer-in-Charge |
| 342 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. |
| 343 | 1 run of cable |
| 344 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking,Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbersclosed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 345 | 6U Rack |
| 346 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8connectors. Housing: PC, UL94V-2, transparent color,Use for 24- 26 AWG stranded wires etc. complete as required. |
| 347 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/ULverification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 348 | Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. |
| 349 | Telephone socket outlet |
| 350 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 351 | 1 or 2 Module (75mm x 75mm) |
| 352 | Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC |
| 353 | Supply, installation, testing and commissioning of Junction Boxes/DB-20 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC |
| 354 | Supplying Installation Testing and Commissioning of 4MP IP IR Dome Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB,Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4,AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation,Multi zone Privacy Masking, HLC, Digital Watermarking. |
| 355 | 3) Compression (Minimum): Video:- H.265 or better,Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 |
| 356 | 4) Wide Dynamic Range:- WDR (120dB or more) |
| 357 | 5) Digital Noise Reduction:- DNR (3D) On/Off |
| 358 | 6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps , Sub streams minimum: 720P@25/30 fps |
| 359 | 7) Image Setting: Rotate Mode, saturation, brightness,contrast, sharpness adjustable through client softwareor web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection |
| 360 | 8) Cyber Security: AES 256-bit Encryption,Configuration encryption, trusted execution, Digest,security logs, account lockout, video encryption,IP/MAC filtering, HTTPS, trusted upgrade |
| 361 | 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. |
| 362 | 10) Recording Management: Format SD, overwrite,storage management, video to NAS device, |
| 363 | 11) Alarm Trigger : Motion/tampering detection;network disconnection detection; IP conflict detection;memory card state detection; memory space detection12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast, |
| 364 | 13) System Capability: ONVIF, Camera shall support open source VMS |
| 365 | 14) Ethernet: 1 RJ 45 10/100 Ethernet port |
| 366 | 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. |
| 367 | 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. |
| 368 | 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE |
| 369 | 18) Housing/ Enclosure:- IP67 weather proof, IK10,Metallic body |
| 370 | 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) |
| 371 | 20) IR life: 40000 hours or higher |
| 372 | 21) Video Bit rate: 32 KBPS - 8 MBPS or better |
| 373 | 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 374 | 4MP @ 25/30fps@1440P (2560 x 1440) Dome Camera with 2.8/ 3.6/ 6/8/12 mm fixed lens (as per site requirement). |
| 375 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR)with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more andmust be ONVIF with minimum support of 384 Mbps incoming Bandwidth. |
| 376 | 2) NVR should support video compressions : H.265 or better, H.264, MJPEG.3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u,PCM, G726 audio compressions.4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10.6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x |
| 377 | 8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports toconnect various type of external sensors and outputdevices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6,UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE,FTP, DDNS, Alarm Server, IP Search, Multicast, AutoRegistration, ONVIF (Profile T, Profile S, Profile G),CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS, BIS Certified14) Power Supply : Should support AC100-240V, 50/60Hz Power supply. 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)16) The VMS application shall support all the features & functionalities of the offered cameras.17) VMS should consist Licenses for all channels to record Cameras with General, motion detection,intelligent, alarm and POS recording modes. VMSshould be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. |
| 378 | 8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports toconnect various type of external sensors and outputdevices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6,UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE,FTP, DDNS, Alarm Server, IP Search, Multicast, AutoRegistration, ONVIF (Profile T, Profile S, Profile G),CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS, BIS Certified14) Power Supply : Should support AC100-240V, 50/60Hz Power supply. 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)16) The VMS application shall support all the features & functionalities of the offered cameras.17) VMS should consist Licenses for all channels to record Cameras with General, motion detection,intelligent, alarm and POS recording modes. VMSshould be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. |
| 379 | 24) It should have Web and GUI interface.25) Built-In Artificial Intelligence: NVR should havebuilt-in AI :-- 2 Channel face detection and recognition, - Minimum4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detectionspeed of 12 face images/sec and facility to add Name,gender, birthday, address, credential type, credential No., countries & regions and state to each face image.27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses,expressions, face mask, beard, Top color, top type,hat, bag, age, gender and umbrella.28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body,vehicle model, vehicle logo, calling, seatbelt, vehicleregistration location etc vehicle attributes. |
| 380 | 29) Alarm Notifications based on: Motion detection,video tampering, video loss, scene changing, PIRalarm, Camera external alarm, Face detection, facerecognition, perimeter protection (intrusion andtripwire), ANPR, people counting, stereo analysis,crowd distribution, heat map, Disk Full, Storage Error,IP Conflict and abnormal behavior of fan,cybersecurity exception30) Alarm Notification should be linked with Recording,snapshots, Camera external alarm output, buzzer,logs, presets and email.31) General AI Based Search: Search Pictures bychannel, time, event type, target classification (FallDetection, People Approach Detection, People No.Exception Detection, People Staying Detection,Violence Detection.32) Smart playback function: Should support smartsearch for the selected area in the video and smartplayback to improve the playback efficiency33) VCA (Video Content Analytic): Should supportmultiple video contented analytics based on cameraanalytics34) Analytics by NVR: Perimeter protection and facerecognation |
| 381 | 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 |
| 382 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC,Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 383 | 10TB (Terabytes) |
| 384 | Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splicesand terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in,metal splice shelf to protect the fibers, 2 fiber spoolsbuilt-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers forbetter access to interior of LIU, Should be Single /Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiralwrap tube etc complete as required. |
| 385 | 24 Port LIU |
| 386 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance withANSI/TIA-568.2-D etc. complete as required. |
| 387 | Copper Patch Cords of length 1m (3ft) |
| 388 | Copper Patch Cords of length 3m (10ft) |
| 389 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. asmentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by havingSwitching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table.Console Port, USB port, Stacking support of min. 8units per stack. Internal dual AC Power supply, STP,RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLDSnopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ,Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN,VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR,WRED, 802.1p. ACL: MAC based, IPv4C IPv6,TCP/UDP Port number, time based ACL, TFTP Client,SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy basedroute, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports.Certifications: UL, CE, FCC, RoHS, MTCTE,OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 390 | 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. |
| 391 | Supply,Installation,Testing and Commissioning of Media Converter. |
| 392 | Supply & Erection of Termination Box complete as per specification and as desired by EIC. |
| 393 | Supplying,Installation,Testing and Commissioning of 55 Inches Ultra H.D LED Display Monitor as per the Specifications attached. |
| 394 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 395 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 396 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 397 | Supplying,Installation,Testing and Commissioning of Copper Earthing Electrode of Size 50 x 3000mm with Copper Pipe Outer Dia. 50 mm (+-) 5 %),Length 3000 mm,Inner & and Outer Strip Size 25X6mm (Copper),Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs. |
| 398 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I.pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 399 | Supply, installation, Testing & Commissioning of 'Silent Type DieselGenerating set as per CPCB IV + or better norms along with having PrimePower Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging powerfactor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor,including testing at factory and site with fuel, load for test and othernecessary arrangements Complete as per CPWD specifications, shouldhave QR code which should contain drawing, test report OEM manual,Geo-Tag of manufacturing location, rating plate as per relevant IS Code etc. andconsisting of the followings: |
| 400 | (A) Diesel Engine:Turbocharged Diesel engine 4 stroke water cooled, multi cylinder,dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPMsuitable for above output of alternator at 40 Degree C, 50% RH & at 1000Meter MSL , capable of taking 10% over loading for one hour after 12 hours ofcontinuous operation. The engine will be with Electronic governor, Dry typeAir filter with service indicator, first filling of engine fuel (after commissioning)lubricating Oil, Coolant and other consumables complete with all therequired accessories, the Electronic governor shall be as per ISO 8528.Theengine shall comply to the latest CPCB norms (CPCB IV + or better) andConforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as perCPWD specifications. |
| 401 | (B) Engine mounted Instrument Panel fitted with and having digital displayfor following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level |
| 402 | (C) Alternator:Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50%RH & at 1000 Meter MSL. The alternator shall be having Screen ProtectedDrip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamicallybalanced rotor, capable of taking 10% over loading for one hour after 12hours of continuous operation, self cooled,self-excited and self-regulatedthrough AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable fortropical conditions and with class- H insulation. |
| 403 | (D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base framemade of MS channel with necessary reinforcement which shall be installedon suitable cement concrete foundation and vibration isolation arrangementas per recommendations of manufacturer. |
| 404 | (E) FUEL TANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications,fabricated out of 3 mm thick M.S. sheet complete with all standardaccessories and fuel piping between fuel tank and diesel engine with MSclass 'C' pipes of suitable dia. Complete with valves, level indications &accessories as required as per specifications. |
| 405 | (F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalyticconvertor. |
| 406 | (G) Starting System:12V/24V DC starting system comprising of starter motors: voltageregulator and arrangement for initial excitation complete with suitablenumbers of batteries (180 AH capacity lead acid SMF type) as required asper specifications. The battery shall be housed inside the acoustic enclosureof DG Set. |
| 407 | (H) Acoustic and weather proof enclosure with arrangement for fresh airintake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere and the temperature rise inside the enclosure, noise leveloutside enclosure. The acoustic enclosure should be suitable for cableconnection/connection through bus-trunking. Such arrangements onacoustic enclosure should be water proof & dust-proof conforming to IP-65protection. The enclosure shall be as per CPCB IV + or better norms etc. andas per CPWD specifications. |
| 408 | (I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panelincluding auto by-pass, suitable for KVA as below for silent type DG setcomplete with relays, timers, set of CTs for metering & protection and energyanalyser to indicate currents, phase and line voltages, frequency, powerfactor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total),KW & provision for overload, short circuit, restricted earth fault, underfrequency, power (aluminum) and control (copper ) cabling of suitable sizeupto 15 meter between AMF panel, LT Panel and DG Set includingconnection interconnection etc. as required, all complete and inter lockingand communication/ Ethernet /RS485/SNMP port open protocol for BMSintegration including suitable software, the panel shall be of DG Set OEMmake etc. as per approved by Engineering in charge and including thefollowing:1. Suitable numbers and appropriate capacity 4 pole motorisedelectrically operated draw out with cradle type 3 position ACB/ MCCBwith electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Overvoltage |
| 409 | 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15VA class-I for metering5. Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA(Phase & Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set.7. Fuse/ MCB for instruments.8. Battery charger, complete with transformer/ rectifier, D.C. voltmeterand ammeter, selector switch for trickle, off and boost and currentadjustment.9. Main supply failure monitor.10. Supply failure timer.11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failureto start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, OverCurrent, Unbalancing load with suitable number of relays andaccessories17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing ofincomer breakers, bus coupler switching of essential panel ,interlocking providing signal to AMF Panel for load status and AMFshall give command to DG Set to auto start / auto stop depending uponload status and requirement etc. and necessary hardware andsoftware required to perform the operation shall be provided by thecontractor including all control wiring. |
| 410 | 40KVA |
| 411 | Carriage of material from source to site of work by mechanical transport including loading /unloading and stacking complete. |
| 412 | Sand for an average distance of 25 kms by M.T |
| 413 | Stone aggregate below 40 mm nominal size for an average distance of 15 kms by M.T |
| 414 | Stone aggregate above 40 mm nominal size for an average distance of 15 kms by M.T |
| 415 | Brick for an average distance of 100 Km by M.T Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 23, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Nov 12, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysNov 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer