Health and Family Welfare Government Departments Closing in 6 days TDR #58164609

Tender For Repair & Renovation Work Of State Ware House At Sethi Colony, Jaipur.

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
15 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
6 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair & Renovation Work Of State Ware House At Sethi Colony, Jaipur.

BOQ

Name of Work:- Repair & Renovation work of State Ware House at Sethi Colony, Jaipur.
Sl. No. Item Description
1Note: 1. The rates for the civil, sanitary Items are b PWD integrated BSR 2022 (All Raj.).2. In case of any typographical error, the relevant code for specification & BSR for rates shall be final.3. The contents of RPWA 100 shall form the essential & integral part of this G-Schedule.
2Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:
3For thickness of tiles 10mm to 25mm.
4Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
5Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :20mm thick
6Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost ofcentering and shuttering - All work up to plinth level.
7M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
8Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :
9Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick bats complete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification.
10Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
11Providing and fixing to existing door frames.30mm thick factory made solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15 mm x15mm , top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75 mm shall be flat and
1220mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter).
13Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slabincluding grinding, rubbing and polishing complete.
14Good quality South Black
15Above 3601 Cm2 Slabs
16Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
17For area of each slab from 2001 to 5000 Sq.Cm
18Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to suspend
19Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint pplied @ 2.20 kg/ 10 sqm ).
20Providing and applying white cement based putty over plastered surface toprepare the surface even and smooth complete New Plastered Surface (three or more coats)
21Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing andpaneling to be paid for separately). -
22b) For shutters builtup standard tubular sections of openable doors,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). - G-Schedule Name of Work : Misc. works in Room no. 317 at „A‟ Block, Swasthya Bhawan, Jaipur. Page 1 of 3 Rates are Based on PWD BSR 2018 City Circle Jaipur S.No. Description of Item Qty. Unit Rate Amount Powder coating aluminum ( minimum thickness of powder coating 50micron)
23Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors,windows shutters and partition frames with C.P. brass / stainless
24Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer- incharge.(Cost of aluminium snap beading shall be paid in basic item.) - With float glass panes of 5.0 mm thickness ( weight not less
25Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work Full Edge moulding
26Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge.
27Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :-
28Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.
29Applying Epoxy primer on the exposed steel bars.
30Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush.
31Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.
32Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.
33Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect.
34Replacement of stone Chajja with sriwan in damaged portion as per existing thickness and width in CM 1 : 3 with removal of old damaged pieces of chajja including top plaster of chajja and bottom pointing in CM 1 : 3 with scoffolding upto Ground floor level as per direction of Engineer in charge
35P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.
36size 600 mm X 600 mm
37Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge
38Window openable.
39Fixing standard steel glazed doors, windows and ventilators in walls with 15x3mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including fixing of glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws (only steel windows with lugs, glass pane cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.)
40P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor:
41Size 580x440mm.
42P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trapincluding cutting and making good the wall and floor
43P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted,1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make,25 mm G.I. waste pipe complete including cutting &
44Size 580 mm x 450 mm
45P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back (large) or half stall size 610x400x80mm.
46P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction ofEnginner-in-Charge
47P & F Bib Cock (IS : 8931 Mark), Superior quality ofapproved make:
48C.P. Brass bib cock,15mm nominal bore.
49P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.
50---do--- with 37 cm long pipe and nut.
51P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clampsincluding cutting and making good the walls and
52Exposed on wall
5315 mm dia nominal bore
54'B' Class
5525mm dia nominal bore
56'B' Class
57Supply & fixing G.I. Union ISI marked in G.I. pipeline as required complete in all respect of size :
5815mm dia nominal bore
5925mm dia nominal bore
60Making connection of G.I. distribution branch withG.I. main including all fitting.
61Upto 25mm dia
62Labour charges for removing W.C. pan (any type) ofall sizes with care including all necessary fittings P
63P & F C.P. brass Urinal Spreader for Large Urinal of heavy duty of approved make as per direction ofEnginner-in-Charge
64Construction of Cement Concrete Chamber 125mm dia. Stainless Steel Sheet Grating
65P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia
66P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 45 110mm dia
67Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Nahni Trap with Jali 4” 110mm dia
68P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Door Tee 110mm dia
69P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Socket plug 110mm dia
70Labour charges for removing and refixing of urinals (all type & sizes) including all necessary fittings.
71P & F Soap Dish or Tray of approved quality/make WVC (1st Quality, IS 2556 Marked) recessed size 150 x 150 mm.
72P & F Towel Rail or Ring of approved
73C.P. brass Towel Rail elbow type with concealedscrews size 600 mm (Heavy duty).
74P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge
75Oval shape 450x350 mm
76P & F Extension Pipe for bib cocks of approvedquality/make.
77(-do-) 100 X 15mm.
78Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking outsewage including cleaning of site.
79Cleaning of sewer line of various sizes as per requirement at site of different sizes including 100mm,150mm & 225mm dia of Stoneware pipe as per direction of Engineer-in-Charge.
80P & F W.V.C. Urinal Partition Plate of approved standard make of size 630x315mm including making good the wall.
81Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of
82Depth up to 0.5 M
83P & F 15 mm. Dia Connection Pipe of approved quality/make :
84(-do-) 450mm.
85P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete
86PVC with PVC bend and superior internal fittings
87P & F water closet Seat Covers with brass hingescomplete :
88-do- White.
89P & F Full-way Valve (IS:778 Mark) or wheel valveof approved make :
90Gun-metal 15mm nominal bore.
91(-do-) 25mm nominal bore.
92P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete :
93(-do-) wt.Not less than 600 gm, 25mm.
94P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:
951000 (-do-)
96Hoisting Charges for each floor :
97For items 2.26.5 to 2.26.8
98Labour charges for making connection of sewer linethrough main hole.
99Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
100Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
101Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.
102Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement)
103M-35,60mm thick to be used in light traffic (Light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 KN laden weight, or an equivalent up to 0.5 million standard axles (MSA) for a design life of 20 years (A standard axle is defined as a single axle load of 81.6 KN) like pedestrian plazas, shopping complexes ramps, car parks, office driveways , housing colonies, office complexes, rural roads with low volume traffic, farm houses , beach sites, tourist resorts, local authority footways, residential roads, etc. Category ‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP 63:2004
104Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer.
105Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58164609
AUTHORITY Government Departments
TENDER VALUE 15 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Medical And Health Services
Work Description Tender for Repair & Renovation Work Of State Ware House At Sethi Colony, Jaipur.
Basic Detail
Tender No NIT 55 /2026-27 divi I Jaipur
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 23 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value 15 Lakhs
Tender Fee 500
EMD 30000
Exemption Available
Document List
BOQ_1072234.xls
fb917f10-2d42-41a3-87a1-953a6c0a1e75.html
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf
Tendernotice_5.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1072234.xls

html

fb917f10-2d42-41a3-87a1-953a6c0a1e75.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender