Defence Government Departments Closing in 4 days TDR #58164142

Tender For Repair And Maintenance Of Of Ts Barrack At Communication Complex Of 154 Bn Bsf Ambassa Under Shq Bsf Telimura.

Issued by Government Departments · Khowai, Tripura
Tender Value
10.49 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
4 days left
EMD
20999
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khowai → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Of Ts Barrack At Communication Complex Of 154 Bn Bsf Ambassa Under Shq Bsf Telimura.

BOQ

Name of Work:- Repair and Maintenance of of TS Barrack at Communication complex of 154 Bn BSF Ambassa under SHQ BSF Telimura.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil.
2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :-1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :-1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
4Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:-Cement mortar 1:6 (1 cement : 6 coarse sand)
5Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
6Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.-0.63 mm thick with zinc coating not less than 275 gm/ m²
7Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.-0.63 mm thick with zinc coating not less than 275 gm/m²
8Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).-6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 : 2000
912 mm cement plaster finished with a floating coat of neat cement of mix :-1:4 (1 cement: 4 fine sand)
10Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :-Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
11Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
12Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour -Old work (one or more coats)
13Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
14Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :-One or more coats on old work
15Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.-With cement mortar 1:4 (1 cement : 4 fine sand)
16Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:-G.S. Sheet
17Modified Estimated Cost after using Correction factor on DSR 2023 on acount of GST @ 0.973
18Add Cost Index @ 60% on DSR 2023
19Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A
20Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
21Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
22(ii) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
23Supplying and drawing following siizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel PVC conduit as required.(i) 3 x 1.5 sq. mm
24Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
25Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(i) 20 mm
26(ii) 25 mm
27Supplying and fixing following modular type switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(i) 5/6 Amp. Switch
28(ii)15/16 A switch
29(iii) 3 pin 5/6 A socket outlet
30(iv) 6 pin 15/16 A socket outlet
31(v) Telephone socket outlet
32Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
33Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)
344 Module (125mmX75mm)
35Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
36Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
37Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
38Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch,connections etc. as required. (For light plugs tobe used in non residential buildings)
39Supplying and fixing PVC batten/ angle holder including connections etc. as required.
40Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(i) 12 way, Double door
41Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required(i) Single pole
42(ii) double pole
43Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtrs long etc. with charcoal or coke and salt complete as required.
44Providing and fixing 6 SWG dia G.I. Wire in 15 mm dia GI pipe from earth electrode i/c connection with GI nut bolt spring washer exacavation and refilling etc as required.
45Supplying and fixing Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
46Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
47Supplying, installation, testing & commissioning of following pre-wired ,LED type street light fittings, complete with all accessories, and 32 mm dia(nominal) 'B' class GI pipe bracket, reduser for mounting fitting on wall including bending the pipe to the required shape, and connections with 3 x 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. a) 45W LED Street light luminaire with power LEDs. (Acceptable makes: CG make Model- Havells ENDURASUNDOWNSL45WLED765PASYBOTG or equivalent to Havells/philips/crompton
48Providing and fixing 09 watt self ballasted LED retrofit (fitted in normal Lamp holder) bulbs with PBT body shell and PC diffuser.BC 6500K etc.as reqd. make Polycab/Havell/Phillips/Crompton.
49Providing and fixing of 20 watt ,6500 k LED Decorative ultra slim square profile LED lighting fixture with extruded Polycarbonate environmental friendly , energy efficientb ready to use pack directly on ceillng /wall, including round sheet ,connection ,testing and dismantling the existing comlete etc as required. Make- Havells/CG/Phillips/Syska
50Supplying & laying of one number XLPE insulated and PVC sheathed , armoured aluminium power cable of 1.1 KV Grade of size 2X16 Sq. MM conf to IS: 7098 (Part-I) in the existing METAL/HDPE PIPE / IN OPEN as required.
51Supplying and Laying of one no PVC insulated/PVC sheathed XLPE power cable ,1.1 KV grade (heavy duty), armoured UG electric cable with aluminium conductor of size 2 x 16 sqmm direct in ground including excavation and refilling the trench but excluding sand cushioning & protective covering (make Havells / Polycab / Finolex / Gloster.)
52Supplying and fixing G. I. pipe of 40 mm dia (Medium duty) along the wall / surface for protection of UG cable / lightening conductor etc as required.
53Supplying and fixing of 300 mm sweep,( light Duty) exhaust fan suitable for single phase, 50 HZ, 230 v, AC supply in existing opening inlcluding making the hole to suit the size of above exhaust fan & S/F of louver/ Shutter including connection, testing etc. as required of Bajaj, Crompton etc.
54Total Cost (BoQ1+BoQ2)
55Civil work
56Elect work Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58164142
AUTHORITY Government Departments
TENDER VALUE 10.49 Lakhs
LAST DATE 30-10-2026
Authority
Authority Name Border Security Force
Work Description Tender for Repair And Maintenance Of Of Ts Barrack At Communication Complex Of 154 Bn Bsf Ambassa Under Shq Bsf Telimura.
Basic Detail
Tender No IGA/ENGG/E-NIT (CIVIL)/26-27/32
Bidding Type Tender
Location
City Khowai
State Tripura
Key Dates
Publish Date 23 Oct 2026
Submission Date 30 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value 10.49 Lakhs
Tender Fee Ref. Documents
EMD 20999
Exemption Not Available
Document List
4dc0a725-6245-494c-9d68-9f5037484a11.html
BOQ_978720.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

4dc0a725-6245-494c-9d68-9f5037484a11.html

xls

BOQ_978720.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender