Tender For Name Of Work:- Repair And Maintenance Residential Quarter Type-Ii -11 Nos (40-44, & 53-58) Qtr Under Shq Bsf Teliamura.
Tender Value
11.99 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
5 days left
EMD
23999
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khowai → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Name Of Work:- Repair And Maintenance Residential Quarter Type-Ii -11 Nos (40-44, & 53-58) Qtr Under Shq Bsf Teliamura.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately):18 mm thick |
| 2 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 3 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters. with ISI marked M.S. pressed butt hinges bright finished of required size - Kiln seasoned and chemically treated hollock wood |
| 4 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm |
| 5 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm |
| 6 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm |
| 7 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm |
| 8 | 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. |
| 9 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 10 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. Old work (one or more coats) |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
| 12 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 13 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 14 | Modified Estimated Cost after using Correction factor on DSR 2023 on acount of GST @ 0.973 |
| 15 | Add Cost Index @ 60% on DSR 2023 |
| 16 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group B) |
| 17 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.(Group B) |
| 18 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 19 | 2 X 4 sq.mm + 1 X 4 sq.mm earth wire |
| 20 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 3x1.5 Sqmm |
| 21 | 3x4 Sqmm |
| 22 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 23 | 25 mm |
| 24 | Supplying and fixing following metal box following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.75 mm x75mmx 60 mm deep |
| 25 | 100 mm x100 mmx 60 mm deep |
| 26 | 180 mm x 180 mmx 60 mm deep |
| 27 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 Amp. Switch |
| 28 | 3 pin, 5/6 Amp. Socket Outlet |
| 29 | 15/16 Amp. Switch |
| 30 | 6 pin, 15/16 Amp. Socket Outlet |
| 31 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recesswith suitable size of phenolic laminated sheet cover infrontincluding providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch,connections, painting etc. as required. |
| 32 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box / wooden block i/c connection etc as required. |
| 33 | Providing and fixing PVC batten / angle holder including connections etc. as required. |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 35 | Double pole |
| 36 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 37 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required |
| 38 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 39 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 40 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 41 | Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, GI tube having single prong at top with 85mm dia 6mm thick GI base plate, including hole etc complete as required |
| 42 | Jointing copper /GI tape(with another copper/GI tape, base of the finial or any other metallic object) by riveting/nut bolting/sweating and soldering etc. as required. |
| 43 | Providing and fixing GI tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required( for Horizontal run) |
| 44 | Providing and fixing GI tape 20mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required( for Vertical run) |
| 45 | Providing and fixing testing joint, made of 20mm x 3mm thick GI strip 125mm long, with 4 nos of GI bolts, nuts, chuck nuts and spring washers etc. complete as required |
| 46 | LED Batten light (System lumen efficacy ≥120 <135lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumptionshould not more than the specified rating andFixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminium housing such that LED junction temperature shall not riseabove 90°C).Powder coated die cast/Extruded aluminiumBody (Thickness > 1.20 mm) 18- 22 Watt |
| 47 | Total Cost (BoQ1+BoQ2) |
| 48 | Civil work |
| 49 | Elect work Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender