Defence Government Departments Closing in 5 days TDR #58164131

Tender For Name Of Work:- Repair And Maintenance Residential Quarter Type-Ii -11 Nos (40-44, & 53-58) Qtr Under Shq Bsf Teliamura.

Issued by Government Departments · Khowai, Tripura
Tender Value
11.99 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
5 days left
EMD
23999
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khowai → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Name Of Work:- Repair And Maintenance Residential Quarter Type-Ii -11 Nos (40-44, & 53-58) Qtr Under Shq Bsf Teliamura.

BOQ

Name of Work:- Name of work:- Repair and maintenance residential quarter type-II -11 Nos (40-44, & 53-58) qtr under SHQ BSF Teliamura.
Sl. No. Item Description
1Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately):18 mm thick
2Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
3Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters. with ISI marked M.S. pressed butt hinges bright finished of required size - Kiln seasoned and chemically treated hollock wood
4Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm
5Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm
6Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm
7Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm
830 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge.
912 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
10Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. Old work (one or more coats)
11Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work.
12Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (One or more coat applied @ 0.90 ltr/10 sqm).
13Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
14Modified Estimated Cost after using Correction factor on DSR 2023 on acount of GST @ 0.973
15Add Cost Index @ 60% on DSR 2023
16Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group B)
17Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.(Group B)
18Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
192 X 4 sq.mm + 1 X 4 sq.mm earth wire
20Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 3x1.5 Sqmm
213x4 Sqmm
22Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
2325 mm
24Supplying and fixing following metal box following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.75 mm x75mmx 60 mm deep
25100 mm x100 mmx 60 mm deep
26180 mm x 180 mmx 60 mm deep
27Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 Amp. Switch
283 pin, 5/6 Amp. Socket Outlet
2915/16 Amp. Switch
306 pin, 15/16 Amp. Socket Outlet
31Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recesswith suitable size of phenolic laminated sheet cover infrontincluding providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch,connections, painting etc. as required.
32Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box / wooden block i/c connection etc as required.
33Providing and fixing PVC batten / angle holder including connections etc. as required.
34Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
35Double pole
36Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
37Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required
38Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
39Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
40Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
41Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, GI tube having single prong at top with 85mm dia 6mm thick GI base plate, including hole etc complete as required
42Jointing copper /GI tape(with another copper/GI tape, base of the finial or any other metallic object) by riveting/nut bolting/sweating and soldering etc. as required.
43Providing and fixing GI tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required( for Horizontal run)
44Providing and fixing GI tape 20mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required( for Vertical run)
45Providing and fixing testing joint, made of 20mm x 3mm thick GI strip 125mm long, with 4 nos of GI bolts, nuts, chuck nuts and spring washers etc. complete as required
46LED Batten light (System lumen efficacy ≥120 <135lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumptionshould not more than the specified rating andFixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminium housing such that LED junction temperature shall not riseabove 90°C).Powder coated die cast/Extruded aluminiumBody (Thickness > 1.20 mm) 18- 22 Watt
47Total Cost (BoQ1+BoQ2)
48Civil work
49Elect work Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58164131
AUTHORITY Government Departments
TENDER VALUE 11.99 Lakhs
LAST DATE 30-10-2026
Authority
Authority Name Border Security Force
Work Description Tender for Name Of Work:- Repair And Maintenance Residential Quarter Type-Ii -11 Nos (40-44, & 53-58) Qtr Under Shq Bsf Teliamura.
Basic Detail
Tender No IGA/ENGG/E-NIT (CIVIL)/26-27/35
Bidding Type Tender
Location
City Khowai
State Tripura
Key Dates
Publish Date 22 Oct 2026
Submission Date 30 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value 11.99 Lakhs
Tender Fee Ref. Documents
EMD 23999
Exemption Not Available
Document List
5603b0f7-a7e3-43c8-bcba-5a9057f75f47.html
BOQ_978715.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

5603b0f7-a7e3-43c8-bcba-5a9057f75f47.html

xls

BOQ_978715.xls

pdf

Tendernotice_1.pdf

Disclaimer