Tender For Repair And Maintenance Of Ts Barracks Being Used As Q Store And Jawan Barrack At Provisioning Complex At Bsf C Us Ambassa Under Shq Bsf Teliamura
Tender Value
10.49 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
6 days left
EMD
20999
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khowai → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Ts Barracks Being Used As Q Store And Jawan Barrack At Provisioning Complex At Bsf C Us Ambassa Under Shq Bsf Teliamura
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :-1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:-Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :-1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | 12 mm cement plaster of mix :-1:6 (1 cement: 6 fine sand) |
| 6 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:-G.S. Sheet |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 8 | Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m2 |
| 9 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. |
| 10 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 11 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour -Old work (one or more coats) |
| 12 | Finishing walls with Acrylic Smooth exterior paint of required shade :-Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 13 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :-New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution |
| 14 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 15 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.-With 12 mm mild steel U beading |
| 16 | Modified Estimated Cost after using Correction factor on DSR 2023 on acount of GST @ 0.973 |
| 17 | Add Cost Index @ 60% on DSR 2023 |
| 18 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A |
| 19 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 20 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 21 | (ii) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 22 | Supplying and drawing following siizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel PVC conduit as required.(i) 3 x 1.5 sq. mm |
| 23 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(i) 20 mm |
| 24 | (ii) 25 mm |
| 25 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(i) 5/6 Amp. Switch |
| 26 | (ii)15/16 A switch |
| 27 | (iii) 3 pin 5/6 A socket outlet |
| 28 | (iv) 6 pin 15/16 A socket outlet |
| 29 | Supplying and fixing following modular type switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(i) 5/6 Amp. Switch |
| 30 | (ii)15/16 A switch |
| 31 | (iii) 3 pin 5/6 A socket outlet |
| 32 | (iv) 6 pin 15/16 A socket outlet |
| 33 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 34 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 35 | 4 Module (125mmX75mm) |
| 36 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 37 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 38 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 39 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch,connections etc. as required. (For light plugs tobe used in non residential buildings) |
| 40 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(i) 12 way, Double door |
| 41 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required(i) Single pole |
| 42 | (ii) double pole |
| 43 | Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtrs long etc. with charcoal or coke and salt complete as required. |
| 44 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 45 | Supplying and fixing Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 46 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 47 | Supplying, installation, testing & commissioning of following pre-wired ,LED type street light fittings, complete with all accessories, and 32 mm dia(nominal) 'B' class GI pipe bracket, reduser for mounting fitting on wall including bending the pipe to the required shape, and connections with 3 x 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. a) 45W LED Street light luminaire with power LEDs. (Acceptable makes: CG make Model- Havells ENDURASUNDOWNSL45WLED765PASYBOTG or equivalent to havells/philips/crompton |
| 48 | Providing and fixing of 20 watt ,6500 k LED Decorative ultra slim square profile LED lighting fixture with extruded Polycarbonate environmental friendly , energy efficientb ready to use pack directly on ceillng /wall, including round sheet ,connection ,testing and dismantling the existing comlete etc as required. Make- Havells/CG/Phillips/Syska |
| 49 | Supplying & laying of one number XLPE insulated and PVC sheathed , armoured aluminium power cable of 1.1 KV Grade of size 2X16 Sq. MM conf to IS: 7098 (Part-I) in the existing METAL/HDPE PIPE / IN OPEN as required. |
| 50 | Supplying and Laying of one number XLPE insulated and PVC sheathed, armoured aluminium power cable of size 2X16 Sq. MM conf to IS: 7098 (Part-I) direct in ground including excavation,and refilling the trench etc as required, but excluding sand cushioning and protective covering.Make Havells/KEI/Polycab |
| 51 | Supplying and Laying of one no PVC insulated/PVC sheathed XLPE power cable ,1.1 KV grade (heavy duty), armoured UG electric cable with aluminium conductor of size 3.5x 35 sqmm in the existing METAL/HDPE PIPE / IN OPEN as required.(make Havells / Polycab / Finolex / Gloster.) |
| 52 | Supplying and fixing G. I. pipe of 40 mm dia (Medium duty) along the wall / surface for protection of UG cable / lightening conductor etc as required. |
| 53 | Supplying and fixing of phenolic laminated sheet on existing GI metal box switch board / cover. |
| 54 | Supplying, Installation, testing and commissioning of Step type electronic ceiling fan regulator Socket type and dismaintling the existing complete etc.as required including less cost of dismentle material .make havells/ Anchor |
| 55 | SITC of outdoor type feeder piller, Single door made out of 18 SWG CRCA sheet of size 450 mm x 300 mm x 300 mm deep having 160 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front door openable & angle iron frame of size 450 mm x 300 mm with600 mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required. |
| 56 | Total Cost (BoQ1+BoQ2) |
| 57 | Civil work |
| 58 | Elect work Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender