Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #58163317

Tender For Provision Of 33 Kv Interconnection Line Under Ge (Army) Suratgarh At Suratgarh Mil Stn (Job No Sog/Maj Wk/2026-27/02)

Issued by Statutory Bodies & Commissions/Committees · suratgarh, Rajasthan
Tender Value
4.76 Crore
Estimated cost
Bid Submission
19 Nov 2026
21 days left
EMD
5.51 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
suratgarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of 33 Kv Interconnection Line Under Ge (Army) Suratgarh At Suratgarh Mil Stn (Job No Sog/Maj Wk/2026-27/02)

BOQ

Name of Work:- PROVISION OF 33 KV INTERCONNECTION LINE UNDER GE (ARMY) SURATGARH AT SURATGARH MIL STN (JOB NO SOG/MAJ WK/2026-27/02)
Sl. No. Item Description
1NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting
2Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
3Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
4Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
5M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
6S & F XLPE cable end termination, heat shrinkable, indoor type complete with jointing material and accessories suitable for voltage 19 kV/ 33 kV (Earthed), 3 core, 240 sqmm to 300 sqmm complete all as specified and as directed.
7S & F XLPE cable end termination, heat shrinkable, outdoor type complete with jointing material and accessories suitable for voltage 19 kV/ 33 kV (Earthed), 3 core, 240 sqmm to 300 sqmm complete all as specified and as directed.
8S & F cable jointing kit for 19 kV/ 33 kV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm complete all as specified and as directed.
9Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 19 kV/ 33 kV, three phase, earthed system, 3 core, screened, armoured power cable, 300 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 and to be laid in trenches, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe etc. making all connections with necessary glands, lugs, bushing complete all as specified and as directed.
10M & L for earthing complete with galvanised steel perforated pipe electrode 40 mm nominal bore, medium grade, 2.5 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from pipe electrode to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
11Supply and fix metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, station class, heavy duty, nominal discharge current 20 kA, switching impulse discharge current 2 kA, repetitive charge transfer rating (Qrs) more than 2.4 C, thermal energy rating (Wth) more than 10 kJ/kV, nominal system voltage 33 kV, highest system voltage 36 kV, rated voltage of arrester 27 kV, continuous operating voltage 21.6 kV, temporary overvoltage (30.45 kV for 1 s, 28.50 kV for 10 s, 26.35 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 170 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 69 kV, switching impulse residual voltage (30/60 µs) at switching impulse discharge current maximum 58 kV, high current impulse withstand capability (4/10 µs) 100 kA, minimum creepage distance 900 mm complete all as specified and as directed.
12S & F gang operated air break switch as per IEC 62271-103 amended upto date, rocking/ tilting type, suitable for both horizontal and vertical mounting, three poles, outdoor type, nominal system voltage 33 kV, rated voltage 36 kV, rated frequency 50 Hz, continuous current rating 400 Amps, rated short time withstand current for one second 16 kA, rated peak withstand current for one second 40 kA, rated lightning impulse withstand voltage (i) to earth and between poles 170 kV (Peak) (ii) across the isolating distance 195 kV (Peak), power frequency withstand voltage between (i) earth & poles 70 kV (rms) (ii) across the isolating distance 80 kV (rms), minimum isolating distance in open position 520 mm, phase to phase clearance 1220 mm, minimum cross sectional area of fixed contact 300 sqmm, minimum cross sectional area of moving contact 250 sqmm, copper connector having minimum cross sectional area of 250 sqm, maximum current density of 1.6 Amps/ sqmm for all current carrying parts, single number of brake per phase, medium grade galvanised iron pipe of 32 mm nominal bore and 5 to 6 metre length in single piece for operating pipe, pad-locking in both ‘on’ and ‘off’ position with indicators, electroplated nonferrous parts, hot dip galvanised ferrous parts, 3 Nos porcelain post insulator per phase as per IEC 60168 amended upto date having rated voltage 36 kV, minimum creepage distance 900 mm, impulse withstand voltage 170 kV, wet power frequency withstand voltage 75 kV, dry wet power frequency withstand voltage 75 kV complete all as specified and as directed.
13Supplying, installing, testing and commissioning 33 kV, 630 A, 3 Phase, 50 Hz, outdoor type, floor mounted, SF6 insulated Load Break Switch (LBS), manually operated, suitable for 36 kV Class, complete with integral earthing switch, quick-make/quick-break spring assisted operating mechanism, mechanical closed-open-earthed indication and necessary mechanical interlocking. The LBS shall conform to the latest applicable IEC 62271-103 and complete metal enclosed kiosk to IEC 62271-200, with short time withstand current as per system fault level, weatherproof outdoor enclosure (minimum IP55). SF6 density/ pressure indication, cable entry/ gland plates, cable support, internal earth bus bar including all necessary accessories/ foundation and PCC works as per OEM recommendation, complete all as specified and as directed.
14Supplying, fixing, testing & commissioning, training Portable Cable Fault Locator which shall be used for Cable Testing, Fault Pre-Location, Pinpointing and Fault Conditioning etc. complete all as specified and as directed.. Test system should be versatile to test HT & LT cables of different types, sizes and various voltage levels like 33 kV, 22 kV, 11 kV, 6.6 kV and 415 V. The kit shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The most essential requirement is that the unit should be easily portable and must not weight higher than 200 kg. All the features explained below should be inbuilt into one unit except the pinpointing set and comprise of the units as specified.
15Material and labour for laying of double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 200 mm, minimum inside dia 150 mm conforming to IS 16205 (Part 24) : 2017 including boring of holes by trenchless technology using ultra sounding technique and necessary machine including all fittings complete all as specified and as directed.
16Supplying, installing, testing and commissioning non-extensible type, outdoor type, SCADA Compatible Motorized, SF6 gas filled Ring Main Unit, rated voltage 36 kV, 3 Phase, 4 wire, 3 functions (ways) Classification lAC AFLR and Internal arc 25 kA 1s as per IEC 62271-200 complete all as specified and as directed comprising the followings: -(A) 630 Amps VCB (vacuum circuit breaker), outdoor type, draw out type, manual/ motor spring charge type, totally enclosed metal-clad switchgear, rated voltage - 36 kV, operating voltage 33 kV, Lightning Impulse Withstand Voltage- 170 kVp, one minute dry/wet power frequency withstand voltage primary- 70 kV rms, Rated Dynamic Withstand Current for 1 second duration-62.5 kAp, rated frequency - 50 Hz, rated normal current - 630 Amps, rated short-time withstand current -25 kA, rated peak withstand current – 62.5 kA, rated duration of short circuit - 3 sec, rated operating sequence– O-3-min-CO-3-min-CO- 1 No Outgoing and 2 Nos Incoming(B) Current Transformers (CTs), Resin-cast, triple-core, CTs for metering and protection, backup protection (e.g., Ratio 30-75-150/1A, Class 0.5, 2.5 VA, class 5P10, 2.5 VA) shall be provided for all VCBs outgoings.(C) Potential Transformer (PT), Draw-out type, Resin-cast, 3-phase PT with fuses (e.g., Ratio 11 kV /√3 / 110 V/√3 V, accuracy class 0.5. 50 VA for metering, 3P for protection) shall be provided for VCB of outgoing only.(D) Numerical Protection Relays, microprocessor-based three overcurrent and earth fault relays (IDMT + Definite Time) with communication port (IEC 61850 / Modbus) shall be provided for all VCBs and Load Break Switch (Isolator) of Incomings and outgoings.(E) Digital Multifunction Meters (MFM), class 0.5S energy meters displaying Voltage, Current, kW, kVA, kWh, and Power Factor shall be provided for all VCBs of Incomings and outgoings.(F) Control accessories: Breaker Control Switches (TNC), voltage presence indicator, Local/Remote selector switches, and LED indication lamps (ON, OFF, TRIP, Spring Charged, Trip Circuit Healthy) shall be provided for all VCBs and Load Break Switch (Isolator).
17Srl Item No 15 Continued......(G) 11 kV busbar of Electrolytic Grade Copper of ratings of 800 Amps continuous current, cross sectional not less than 500 sqmm current density of 1.6 Amps/sqmm, 25 kA Short time current rating for 3 Sec shall be provided.(H) Standard manometer with non-return valve -01 for each tank, operating handle – 02 Nos, cable clamping provision(standard)-01 /for every cable entry, Operation and maintenance manual - 01, installation and commissioning manual - 01, Foundation as per OEM Recommendation (Earth Work and PCC works) for placing RMU on plinth is deemed to be included in the cost quoted. Height of plinth should not be less than 0.45 meters from ground level, necessary wiring as details as specified and as per the codal requirement.(J) The VCB panel shall be SCADA compatible with following provisions: - (i) DC control supply system should be 24 V DC.(ii) Battery charger to cater load of minimum 10 motorized operation cycles (Close-Open) in absence of battery.(iii) Battery to cater load of minimum 10 motorized operation cycles (Close-Open) in absence of battery charger. The battery backup should be minimum of 6 Hrs.(iv) Miniature Circuit Breakers (MCB) shall be provided for battery charger supply, RMU Motor supply & FRTU supply (Minimum 2 Amp circuit for future use of FRTU).(v) Individual control circuit of Isolator/Circuit Breaker to have point of isolation/protection.(vi) Individual motor circuit of Isolator/Circuit Breaker to have point of isolation/protection.(vii) The Ring Main Unit shall have minimum protection of IP54 for Outer Enclosure with gland plate & knock outs. Provision for control cable entry should preferably be from Right/ Left top through LV cable box & shall be independent of HV Isolator/Circuit Breaker status. It should be vermin proof.(viii) Control cable gland plate shall be independent of power cable gland plate.(ix) The point of earthing for control cables shall be electrically isolated from power cable earthing.
18Srl Item No 15 Continued......(x) Ambient temperature of 50⁰C max. Allowable temperature rise of battery & battery charger above ambient 40⁰C.(xi) Local / Remote switches shall be provided on all the isolator & breaker panels for selection of controls.(xii) Current Transformer & Potential Transformer terminals for all the circuit breakers for Distribution Transformers / Feeders only.(xiii) Fault Passage Indicator shall be provided per isolator. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58163317
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 4.76 Crore
LAST DATE 19-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of 33 Kv Interconnection Line Under Ge (Army) Suratgarh At Suratgarh Mil Stn (Job No Sog/Maj Wk/2026-27/02)
Basic Detail
Tender No 84598 CA NO CE BTZ/SOG/TOKEN-24 OF 2026-27
Bidding Type Tender
Location
City suratgarh
State Rajasthan
Key Dates
Publish Date 22 Oct 2026
Submission Date 19 Nov 2026
Open Date 21 Nov 2026
Finance
Tender Value 4.76 Crore
Tender Fee 2000
EMD 5.51 Lakhs
Exemption Available
Document List
BOQ_891877.xls
f779e883-df90-4643-b30a-4f79b7a2c4ed.html
TenderDocuments84598.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Nov 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_891877.xls

html

f779e883-df90-4643-b30a-4f79b7a2c4ed.html

pdf

TenderDocuments84598.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender