Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58163316

Tender For Special Repair To Ug Ops Infrasrtucture At 8Fbsu

Issued by Statutory Bodies & Commissions/Committees · Pulwama, Jammu and Kashmir
Tender Value
55.53 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
18 days left
EMD
1.08 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Ug Ops Infrasrtucture At 8Fbsu

BOQ

Name of Work:- SPECIAL REPAIR TO UG OPS INFRASRTUCTURE AT 8FBSU
Sl. No. Item Description
1Dismantling floor hearth or wall tiling including cement mortor bedding (but not backing) removing serviceable tiles & rubbish of the premises complete.
2M&L coloured/printed non skid ceramic tiles 7 mm thick (squre/rectangular) area of each tile exc 0.11 but not exc 0.18 sqm laid in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement, complete all specified and directed.
3-ditto- but on vertical surfaces such as skirting incl including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
4M&L coloured/printed vitrified tiles 9 to 10mm thick (square or rectangular ) of area exc. 0.18 sqm and not exc 0.36 sqm and laid in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement, complete all specified and directed.
5-ditto- but on vertical surfaces such as skirting incl including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
6M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of 450x300x7mm / 350x 250x 7 mm / 450X 350X 7mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, laid over and including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
7Demolition/ Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc laid beded and pointed in any mortar, complete all specified and directed.
8M&L for 20mm thick granite stone (slab) of any colour/type, (table rubbed and polished) work as in floors/ vertical surfaces, cooking platforms and like, set in neat cement including pointing in white cement with admixture of pigment to match with shade of granite, complete laid over and including 20 mm thick screed bed in cement mortor (1:3) laid and jointed with gray cement slurry mixed with pigment, complete all specified and directed.
9M&L for Rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situations complete all as specified and as directed
10Demolition of cement concrete to ground floor(unreinforced) and paving not exc 15cm thickness below or above ground level and removing rubbish of out side MOD land, complete all as specified and directed.
11M&L for PCC (Nominal mix) type D2 1:4:8 using 40mm graded crushed stone aggrtegate as in foundation, filling and mass concrete complete all as specified and directed.
12M&L RCC (nominal mix) as in slabs, shelves and other like items of Type B1 1:2:4 (20 mm gradded aggregate) complete all specified and directed.
13Dismantling of worn out timber scantlings in any size in framed work over 40 sq cm and over in section of truss and railing and removing from site, complete as specified and directed
14Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
15Dismentalling of plain or corrugated steel sheeting of any gauge, thickness etc in roof coverings/cladding/eave etc complete all as specified.
16S&F galvanised corrugated mild steel sheeting, with two corrugation side lap fixed with 'L' type or 'J' type or cranked hooked bolts with washers in roof, 0.63mm thick, grade-O quality, with 120 grms/sqm zinc coating and grade 'B' Class 8 complete all as specified and directed by Engineer-in-Charge.
17S&F Galvanised plain mild steel sheeting 0.63mm thickness fixed with 'L' type or 'J' or cranked hook boltes with washers, in roofs as in ridge etc all as specified and directed.
18S&F Roof trusses (framed), trussed,posts, struts, purlins, crane gantries,rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats,base plate and gusset plates etc confirming to Fe 410 -W (Gde-E- 250) quality-A complete all as specified and directed.
19Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed
20M&L Brick work with sub class B bricks ,straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed.
21Raking out cement mortar joints/ pointing to brick work in walls or to bricks on edge in floors, surface channels, roofs, etc,and removing same from the Site(s), complete as specified and directed.
22M&L for pointing to stone masonary in cement mortar 1:3, Flush to brick walls , filling with mortar, pressing hard flush with brick face and finishing smooth with trowel, complete all as specified and as directed.
23Taking down Cement Plaster, any description on Brick Walls or on Concrete Surfaces including raking out Joints, hacking for Key, scrubbing down with Water etc, and removing same from the Site(s), complete all as specified and as directed.
24M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 on wall surfaces, finishing the surface even and smooth without using extra Cement complete all as specified. Note:- Intgral water proofing compound shall be measured and paid for separately.
25M&L for rendering 10 mm thick on fair faces of concrete/brick interior surfaces in cement mortar 1:6 on wall finished fair and even without using extra cement complete all as specified and directed.
26M&L for rendering 5 mm thick on fair faces of concrete/brick interior surfaces in cement mortar 1:3 as in ceiling finished fair and even without using extra cement complete all as specified and directed.
27M&L preparation of newly plastered wall surface and applying of Birla/JK white wall putty 1mm thick as per manufacturer's instruction and make the surface smooth by rubbing with sand papers and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed.
28M&L preparation of newly plastered ceiling surface and applying of white wall putty 1 mm thick as per manufacturer's instruction and make the surface smooth by rubbing with sand papers and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed.
29Preparing new plastered or un-plastered surfaces of walls and applying two coats Acrylic exterier emulsion paint in camouflaging (Disruptive) pattern (Green, Grey & Brown colour) over a coat of acrylic primer complete all as specified and directed. (Make:Asian/Berger/Nerolac/ICI/Shalimar/Garware/Johnson).
30M&L for Complete removal of existing treatment of old decorated plastered or un plastered surfaces of wall and applying two coats of Acrylic washable distemper over a coat of primer , complete all as specified and directed.
31M&L for Complete removal of existing treatment of old decorated plastered or un plastered surfaces of ceiling and applying two coats of oil emulsion,white or tinted distemper over a coat of primer , complete all as specified and directed.
32Preparation of new surfaces of steel or iron work or CGI/ PGI sheeting in walls or roofing, over 10cm width or girth, not otherwise described and applying two coat of synthetic enamel paint in camouflaging (Disruptive) pattern in three colours (Green, grey and brown) over a coat of acrylic primer complete all as specified and directed. Make : Asian/ Berger/ Nerolac/ ICI/ Shalimar/ Johnson
33Preparation of old painted surfaces of steel or iron work or CGI/ PGI sheeting in walls or roofing, over 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint in camouflaging (Disruptive) pattern in three colours (Green, grey and brown), complete all as specified and directed.
34M&L for preparing of new or previous untreated steel surfaces over 10cm width or girth and making good including red oxide primer and make the surface smooth by rubbing with sand papers etc and applying two coat of synthetic enamel paint complete all as specified and directed.
35M&L for preparing of old painted steel surfaces over 10cm width or girth and making good with & including by necessary red lead putty and make the surface smooth by rubbing with sand papers etc and applying one coat of synthetic enamel paint on old prepared surfaces of steel complete all as specified and directed.
36Preparation of new wooden surfaces of any description not otherwise described, over 10 cm width or girth and providing two coat of synthetic enamel paint over one coat of pink primer all as specified & directed.
37Supply only liquid water proofing compound complete all as specified.
38Taking down chowkhats of frames of any description n.exc 1.50 sqm with shutters (without taking off shutters from the frames) and making good disturbed portion complete all as specified and directed.
39Taking down chowkhats of frames of any description exc 1.50 sqm but not exe 4sqm with shutters (without taking off shutters from the frames) and making good disturbed portion complete all as specified and directed.
40Taking down shutters of any description exc. 1sqm and not exc. 2 sqm each, complete all as specified and directed.
41Taking down shutters of any description exc. 2 sqm each, complete all as specified and directed.
42Design, providing, installation and fixing 12mm thick toughened frosted glass doors upto 2.10 m with all as per required arrangement and proper machine edge finish in angle and fixed in the flooring side with Aluminium 'U' channel. Glass panels to be formed as per approved modules 12mm thick clear thick toughened glass edge polished and accurate designed holes to be installed by means of steel fittings of an approved make. Including floor spring, lock of approved make, long door handle both sides (SS make), all works including labour, wastages, cost of scaffolding, finishing with frosted design film with Logo embedded etc complete. Note : Logo to be provided at the time of execution.
43S&F for solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube supply and fixing as specification and drawing.
44S&F of factory Made Solid panel PVC door shutter, 28 to 30mm thick (stiles) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded and wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet eading plain colour PVC sheets for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling and fixing in the frame at site as per specification & drawing.
45S & F Factory made Glazed and skeleton shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass/gauze etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); in second class hardwood, Complete all as specified and directed by Engineer-in-Charge
46M&L for 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane, complete all as specified and directed.
47S&F 35 mm thick Second class hard wood factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated as directed by Engineer-in-Charge.
48S&F of door closer Aluminium (extruded section) body hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
49S&F of door closer Aluminium (extruded section) body hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 80 kg and fixed
50Supply and fixing Butt hinges, (ISI Marked), aluminium alloy with galvanised mild steel, of size 100mm long all as specified & directed.
51S&F 100 mm long stainless steel butt hinges medium weight with stainless steel screw complete.
52S&F extruded aluminum alloy handles of size 100mm fabricated type anodised complete.
53S&F extruded aluminum alloy handles of size 150mm fabricated type anodised complete.
54S&F extruded aluminum alloy handles of size 125mm fabricated type anodised complete.
55S&F for 150/200mm Extruded brass handles, fabricated type polished, fixed in repair complete all as specified and directed by Engineer in Charge.
56S&F Aluminium alloy anodised barrel tower bolts of extruded section 150 mm long and fixed complete.
57S&F Aluminium alloy anodised barrel tower bolts of extruded section 200 mm long and fixed complete.
58S&F Aluminium alloy anodised barrel tower bolts of extruded section 100 mm long and fixed complete.
59S&F Aluminium alloy, anodised, sliding door bolt size 200mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
60S&F for Brass, 300mm long sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed in repair complete all as specified and directed by Engineer in Charge.
61S&F Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring 150mm long complete all as specified and directed.
62S&F Anodised aluminium frame for doors,windows and ventilator with one or more rebates including joining cleat for fixing etc. complete all as specified
63S&F Anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing of 0.55 kg/RM including fixed with alumnium beading, silicon lining and gaskets,necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed
64S&F anodised aluminium door shutters, aluminium section weighing 1.10kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
65M&L 4.8 mm thick sheet glass, ground or obscured or frosted/ tinted and glazing with oil putty or fixed with bead/glazing pins in squares of exe 0.5 sqm in each pane all as specified and directed.
66M&L Welding in repairs of old/broken steel windows/door shutter exc 2.50 cm but n. Exc. 5.00 cm in length and thickness of metal exc 6mm but n.exc 9mm complete all as specified.
67S&F Factory made Steel windows or ventilators side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete, with glazing bars, dovetailed or welded type of 'Z' Section comprising double frame for gauged and glazed skelton shutter jointed internally with flat iron 40x4 mm complete all as specified and directed by Engr-in-Charge.
68S&F of galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks, or galvanized wire staples all as specified & directed.
69S&F 3mm thick sheet glass, ordinary type and glazing with oil putty or fixed with bead/glazing pins in squares size n.exc 0.5 sqm in each pane, all as specified and directed.
70S&F of mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, used as cover to duct with handles provided in between to lift the plates, discontnious over the entire length, of grade Fe-410 W(gde- E-250) quality B, complete as specified.
71Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets on any description, any thickness, including cover fillets.
72M&L for prelaminated particle board 12mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination with all around 6mm thick teak wood beading as in false ceiling ,cup board shutters, shelves,palmet boxes etc, fixed to timber frame complete all as specified
73S&F Gypsum board 12 mm thick in ceiling fixed with screw as per manufactureres instruction or in metal framework,complete all as specified
74Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
75S&F PVC SHEET WALL PANELLING of thickness 5mm consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm thick prelam PVC sheet. The strips should two PVC strips. The PVC strip shall be fixed to the wall using 65mm long M.S screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a U Channel at top, bottom and side edges and strips of 5mm thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement complete all as specified and directed ( Note- Including all nesscesary fittings and scafolding for heighted site).
76S&F in repair PVC flushing cistern 10 ltr capacity white with all internal fittings including brackets PVC connection 45cm long including nut and PVC washer at both ends including 32mm bore PVC long bend flush pipe 90cm long complete all as specified and directed.
77S & F in repair Vitreous china wash hand basin coloured, flat back type of size 550mm x 400mm including waste pipe & plug, porcelain stopper, 32mm dia PVC waste pipe with CP brass coupling and set of bracket complete all as specified and directed.
78S&F in repair Vitreous China wash down water closet (pedestal pattern), White/coloured including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC coloured seat cover and chromium plated jet including PVC connection, fixed complete including demolition of old unservicable WC and provision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate, fixed in repairs complete all as specified and directed.
79S&F in repair Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, crystal white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-I using 20 mm graded crushed stone aggregate complete all as specified, incl making connections to trap and to flush pipe, etc and making good to floors to match existing, in repair, complete all as specified and directed.
80S&F in repair Vitreous China urinals of minimum size 580x380x350 mm, crystal white, HALF STALL URINAL, with 32 mm bore waste fittings, brass, chromium plated with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including spreader, 60mm long brass screws, pointing around urinal back in cement with brackets, flush pipe, trap, grating and Union for discharge pipe. (Including fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
81S&F in repairs, 18 mm thick Pre-laminated HD HMR board, both side laminated with teak finished with nails /screws as in kitchen cabinet/shelves/cup board shutter including 6 mm thick thick teak wood beads all around complete all as specified and directed.
82S&F 1.5 mm thick stainless steel telescopic channel of size 30mm wide for sliding drawer at extended length with all necessary fixing arrangement to the drawer/wall complete all as specified and directed.
83S & F in repair continous (piano) hinges mild steel, 40mm width of flaps (when open), bright finish or electrogalvanised.
84S&F for size 75mm Brass handles, cast type, polished bright complete all as directed by Engr-In-Charge.
85S&F 50mm dia cupboard knobs of MS fixed with nuts, screws and washers complete all as specified and directed.
86S&F for ball catcher for cupboard/cabinet etc complete all as specified and directed.
87S&F in repair toilet paper holder of brass, chromium plated fixed to walls with chromium plated (CP) brass screws
88S&F sinks with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
89S&F stainless steel plate rack of 1 mm thick for kitchen including fixing cantilever brackets ,overall size 900mmx750mmx250 mm all as specified and directed by Engineer in Charge.
90Taking up or down 15 mm dia steel tubing in wall, ceiling or floor and connections,including cleaning for refixing or removal to store etccomplete.
91S&F 15 mm dia steel tubes medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors.
92Cutting chases,pinning for concealed water tubing and making good to facing where required and pointing in cement mortar 1:3 ,cutting exc 10cm but n.exc 20cm girth all as specified and as directed.
93S&F in repair 20mm bore gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
94S&F in repair brass chromium plated tubular towel rails 20mm dia D type 60cm long between flanges with chromium plated bracket and fixed all as directed.
95S&F in repair 500 litre capacity rotational moulded polyethylene water storage tank (cylindrical vertical double layered with closed top) duly provided with necessary fittings/ fixtures for connecting inlet, outlet, washout and overflow pipes; hoisted and fixed in position incl dismantling PVC water sotrage tanks of capacity more than 250 to 500 litres capacity complete all as specified and directed.
96S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
97S&F in repair 15 mm bore CP Bib tap cast copper alloy fancy type crutch or butterfly handles screwed down for iron or for brass ferrule complete.
98S&F in repair stop valve/angle valve,fancy type, chromium plated, cast copper alloy screwed down,high pressure, with crutch or butterfly handle of 15mm dia. Screwed both ends for iron pipe or for unions and fixed. all as specifid & directed.
99S&F in repair Brass CP central hole wash basin mixer for hot & cold for 15mm dia complete fixed to connection as specified and directed.
100S&F in repair sink mixture for mixing (Hot and Cold) 15mm bore chromium plated cast copper alloy with capstan head screwed for iron pipe fixed complete all as specified and directed
101S & F in repairs Corner Glass Shelf of Size 320 x 320 mm with Silver chromium finished border Oval Range premium quality all as specifed and directed by Engr-in-Charge .
102S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
103S&F in repairs Health Faucet CP with Rubbit Cleaning System , 1.25 m Long PVC Flexible Tube & ABS Wall Hook . Make : (Hindware, Prayag) , complete all as specified and directed.
104S&F in repair CP grating 125mm dia as suitable to existing trap as per requirement , complete all specified and directed.
105S&F in repair ball brass valve ,high pressure with polythene float and flynut complete screwed for iron pipe or ferrule 20mm bore fixed complete all as specified and directed
106S&F in repair 15mm dia 450mm long PVC connection with brass nut and washer complete all as specified and directed.
107S&F 32mm dia PVC waste pipe for wash hand basin, fixed in repair complete all as specified and directed.
108S&F PVC (SWR) pipes single socketed,75mm bore, in any length with rubber ring joints fixed to wall and floor, complete all as specified and directed.
109S&F PVC (SWR) pipes single socketed,110mm bore, in any length with rubber ring joints fixed to wall and floor, complete all as specified and directed.
110M&L PVC (SWR) floor trap 75 mm dia including jointing with solvent cement complete.
111S&F in repair of PVC (SWR) floor trap of 110mm dia, plain with grating incl jointing with solvent cement complete all as specified and directed.
112S&F in repair of PVC (SWR) bends any radius of 75mm bore, complete all as specified and directed.
113S&F PVC (SWR) 110mm bore (dia), Bends, any radius with access door and Jointing with Solvent Cement and fixed-in-repairs, complete all as specified and as directed.
114S&F PVC (SWR) 75mm bore (dia), Bends, any radius with access door and Jointing with Solvent Cement and fixed-in-repairs, complete all as specified and as directed.
115S&F PVC SWR) 'T' junction 75mm dia complete all as specified and directed.
116S&F PVC SWR) 'T' junction 110mm dia complete all as specified and directed.
117S&F PVC (SWR) vent cowl 75/110mm dia complete all as specified and directed.
118M&L PVC (SWR) Gully trap 125/110 mm setting and jointing with solvent cement complete.
119M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer in Charge.
120M & L cement concrete (1:2:4) type B-1 using 20mm graded aggregate as cement concrete in repair of drains, providing proper slope and edges for proper drainage of water, complete all as specified and directed.
121M & L 75 mm thick PCC (1:2:4) type C-2 using 40mm graded aggregate as in plinth protection even and smooth without using extra cement complete all as specified and directed.
122Demolition of cement concrete (reinforced) to slabs and in shelves and similar suspended work complete all as specified and directed.
123M&L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as directed.
124Form work to soffits of suspended slabs n exc 200mm thick (Horizontal or sloping) rough finished surfaces of concrete, complete all specified and directed.
125Preparing old decorated plastered or un-plastered surfaces of walls by scraping the surfaces, brooming down or steel wire brushing down smoke soot, mould, moss and efflorescence salts and trading oil and greasy spots etc and applying one coat of exterior acrylic emulsion paint in camouflaging (Disruptive) pattern in three colours (Green, grey and brown), complete all as specified and directed.
126Taking down all existing roof treatment and demolition of cement concrete padding/levelling course (any thickness as available in site) including wire brushing and cleaning loose dust etc from surfaces of RCC roof including flashing and junction of paprapet complete all as specified.
127M&L for15 mm thick (average) screed bed/ plaster in cement mortar 1:4 in order to maintain proper slope and base over existing roof surface for laying of APP based polymeric membrane, mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete, all as specified and directed. (Note:- WPC and polymeric membrane shall be measured and paid separately)
128M&L for applying a coat of bitumen primer conforming to IS: 3384-1986 over plastered surfaces @ 0.4 litres/ Sqm of density 0.87-0.89kg/ litres at 25° C and viscosity 70-160CPS (Bitumen primer shall be of same make as of memebrane) including preparation of surfacesAPP (Atactic Poly-propylene polymer) modified membranes, five layered, 3 mm thick weighing not less than 30. kg/ Sqm, having a centre core of polyester non-woven mat (FP) reinforcement dipped into APP modified mix and sealing all the over laps 75mm on length side and 100mm on width side of membranes by torching as per manufacture's instructions by authorised applicator only after applying evenly a tack coat of bitumen VG-10 grade @ 1.20 kg per sqm on the bottom of APP and on top of joints of APP complete all as specified.
129Dismantling boarding of any description, fixed in any position with nails, complete all as specified.
130S&F wooden/frame work for cabinet work, but bullnosed,splayed,chamfered or rounded on face ,exc 13 & not exc 25 sq cm, including nails and other fittings , as specified by engineer in charge.
131Taking up or down 20 mm dia steel tubing in wall, ceiling or floor and connections,including cleaning for refixing or removal to store etc complete all as specified.
132S&F 20 mm dia steel tubes medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors.
133S & F Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates , mild steel hold fast and applying a shop coat of red oxide primer, complete all as specified and as directed.by the Engineer-in-Charge .
134PCC 1:3:6 type c-0 (using 12.5mm graded crush stone agg) in back filling of pressed steel door frame and bed block for hold fast complete as specified by Eng in Charge
135M & L for Repair of Honeycomb,construction joint,cracks repairing and injection grouting -Reconditioning of RCC Slab or wherver required as follow:-
136(i)Chipping all loose concrete and cement plaster on the surface.
137(ii) ALL construction joint and cracks cutting 8 mm * 20 mm in (U , V shape ). Cleaning of joints properly. Apply primer bond coat of SBR based bonding agent slurry coat.Filling of joints cracks with high strength durable strong structural repair polymerfiber reinforced modified mortar--ShaliFix --FRM & Shalimar DAM -It
138(iii) Drilling holes in the concrete surface using electric drill for fixing of PVC Nozzles (4 to 6 inch DISTANCE) at specific joints areas only wherever cracks ,construction joints joints and honey comb area only using 12-14 mm dia.Drilled up to 6 inch deep in the rcc structure placed and fixed With STP quick setting under water repair mortar.Chemical to be injected by using manual pump at pressure of up to 40 psi.Injecting STP SHALI GROUT IP or SHALI SBR NON SHRINK FLOWABLE POLYMERISED LIQUID-pressure through injection pump. Checking & sealing removing of nozzles after injection process is over .
139(iv) After successful surface prepartion apply PRIMER + 3 COAT of SHALICEM EWP--Highly Elastic Cementitious Elastomeric Coating with reinforcement fiber glass net of 40/50 gsm -- Food grade coating with Sprinkling of Sand
140Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket, power or AC,s)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type all as specified and as directed.
141Point wiring for one light point/ fan point controlled by one switch with 1.5 sqmm FRLS PVC insulated unsheathed copper condector single core multi strand flexible cable and 1.5 Sqmm flrs PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead with concealed rigid PVC conduit/ surface mounted PVC conduit (as required at site) medium grade with all fittings ( ISI marked ) controlled by one switch including CI/MS sunk box required size including base plate and switch cover etc complete all as specified and directed by Engr-in-Charge, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete.
142(a) One light point controlled by one switch.
143(b) One light point controlled by one 2 way switch.
144(c) One wall fan/Exhaust fan/ceiling fan point controlled by one switch.
145(d) One 3 pin socket outlet point 5 Amps on independent, with cables 1.5 sq. mm size .
146(e) One 3 Pin socket outlet point 5 Amps on the same board with other switches.
147(f) One 3 pin socket outlet point 15 Amps on independent, with cables 2.5 sq. mm size .
148(g) M&L all as per item No-02 above but for one 3 pin socket out let 16 Amps on Independent board with the cable 4.0 Sqmm and 4 Sqmm FRLS PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead medium grade with all fittings ( ISI marked ) for installation of ACs all as specified and directed by Engineer-in-charge.
149Supply and fixing in repairs for energy saving environmental friendly, LED tubelight fittings 20 watts 4 ft (Aluminium body) long life, impact proof, surface/wall mounting IP 20 LEDs including PVC square block 02 Nos complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size with ceiling rose complete all as specified and directed.
150S&F in repairs LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
151S&F in repairs angular holder with 12 watt LED bulb complete all as specified and directed.
152Supply and fixing in repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
153Supply and fixing in repairs LED step light fitting to be fixed on staircase robust design LED step light IP67/IK10, 6-9 watt 220 V AC decorative type connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
154S & F in repairs Socket outlet modular type 6A 2/3 pin combined 2 module with suitable plate and cover complete all as specified and directed.
155S & F in repairs Socket outlet modular type 6A/16A 2/3 Pin combined 2 module with suitable plate and cover complete all as specified and directed.
156S & F in repairs Switch Modular type one way 06 amps 1 module with suitable plate and cover complete all as specified and directed.
157S & F in repairs Switch Modular type one way 16 amps 1 module with suitable plate and cover complete all as specified and directed.
158S & F in repairs Switch Modular type two way 06 amps 1 module with suitable plate and cover complete all as specified and directed.
159S & F in repairs ceiling rose surface bakelite 3 terminals complete all as specified and as directed by Engineer-in-Charge.
160Supply and fixing in repairs GI Bracket bent to shape fabricated with GI Pipe 40mm dia light grade 1.5m long including mounting clamps nut bolts complete all as specified and directed.
161Supply and fixing in repairs of street light with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics for building outside application with system wattage of 60W 230V AC outdoor type with a nominal efficiency 100 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non corrosive high-pressure die-cast aluminum with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. 4 KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance complete all as specified and as directed.
162M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 06 Sqmm and drawing through & including Non metallic PVC casing caping on walls/ceiling including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in ccocealed PVC casing caping including connecting to main board complete all as specified and directed by Engineer-in-Charge.
163M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 10 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 10 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in casing caping PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge.
164Supply and fixing in replacement Exhaust fan single phase 230Volts, 250mm sweep 1200 RPM in plastic body, including louvers with all connected accessories including making opening for fitting of exhaust fan by breaking wall and making good to the disturbed surface as required complete as specified and directed.(Make: Havells/Khaitan/Orient)Note: Old exhaust fan will be submitted to MES.
165Supply and fix in replacement electric water heater instant Geyser of capacity 05 liter, BEE 5 Star rated complete with all accessories such as safety valve, thermo state, NRV, connection piece etc Complete all as specified and as directed. Make-Havells, Bajaj, Crompton.Note: Old Unserviceable Geyser will be submitted to MES.
166S&F in repair LT panel frame CPRI approved ,2mm thick factory made fabricated to CRCA sheet of suitable size and front door opening and locking arrangement ,provided with top and bottom cable alley ,wall mounted,bus bar chamber (enclosed) 200 Amp having extra space and necessary arrangement for the provision to accumodate and fixing requred mccb's and mcb's incl spray painting with two coat of synthetic enamel paint over a coat of red oxide primer and making complete connecton and comperising of following.
167(a) MCCB 4 pole 415 V 160 Amps with 16 KA for incoming Make:-Legrand/seimens/L&T
168(b) Outgoing MCCB 100 Amp 16 KA-01 Nos.
169(c) Outgoing SPN 32-40 Amp-05 Nos
170(d) Digital multimeter ( Type ELF 3200 series ) with suitable CT ratio
171(e) Aluminum bus bar chamber 4 strips ,3 phase 415 volts, 200 Amp fixed on insulator all as required -01 set
172Supply installation, commissioning and testing LT panel outdoor type both side openable, cubical type, double door, floor mounted, made out of 3.15mm thick MS sheet duly powder coated complete with aluminium bus bar 300 amps rating mounted on epoxy based post insulators duly drilled holes for connections, all as specified including necessay foundation grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and neutral system and ,internal wiring with suitable size of PVC insulated copper cable, copper lugs comprising of following accessories:- (Stand of panel should be such that panel be 45 cm above the ground level and 30 cm below ground.Cost of stand,earthwork and installation be included in deemed rate.(O-Level)
173(i) MCCB 250 Amp, Breaking capacity 50 KA, 4 pole -01 Nos (Main incoming)
174(ii) Digital multifuctional meter showing V,A,PF etc=01 Nos
175(iii) Indicating lamp LED (RYB)- 01 set of three
176(B)Outgoing
177(i) MCCB 200 Amp, Breaking cap 50 KA, 4 pole - 02 Nos
178(ii) Timer Switch for operation of street light along with suitable contactor complete - 01 Nos
179S&F in repairs MCB protected socket PVC plastic base model with socket plug top and 32 Amp MCB SP 240 Volts enclosures with two pin and earth plug and socket complete all as specified and directed by Engineer-in-Charge.
180Shifting of Split type AC/ Window type AC capacity upto 2 Ton from old position and refixing to new position including drilling,cutting,chasing and making good on existing surface of PCC concreting, white cement plastering and all necessary items including transporting of ACs from one location to other location in station and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by Engineer-in-Charge.
181S&F in repairs copper pipe 5/8\\" complete all as specified and directed by Engineer-in-charge.
182S&F in repairs copper pipe 1/4\\" and removing old u/s copper pipe complete all as specified and directed by Engineer-in-charge.
183Taking down existing exhaust fan/ ceiling fan/wall fan any size with due care and refixing with new lock bolt (where required)and after servicing and cleaning/painting if required including connecting electrically using PVC insulated overall sheathed flexible copper conductor cable 0.75 mm all as required and directed.
184S & F in repairs MCB Distribution board, Single pole & neutral 240 Volt, 6 way, type With 200 Amps bus bar complete all as specified and directed.
185S & F in repairs MCB Distribution board, Triple pole and neutral 415 Volt, 04 way, type With 200 Amps bus bar complete all as specified and directed.
186Supply and fixing in repairs amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
187(a) SP 5 To 32 AMP
188(b) SPN 40 to 63 AMP
189(c) TPN 63 Amp
190Supply and fixing in repairs 36 watts recess /surface mounting LED flat panel 2' X 2' made of extruded aluminium frame with high LEDs & glare free opal diffuser IP20. L of Crompton equivalent of Philips/Wipro all as required at site and as specified and directed by Engineer-in-charge.
191Supply, laying in repairs or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor heavy grade of size 70 Sqmm, 3.5 core including making electrical connection with thimbles complete all as specified and directed.
192Supply, laying, in repairs , or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 25 Sqmm, 4 core including making electrical connection with thimbles complete all as specified and directed.
193Supply and fixing , in repairs, 1100 volts grade heavy duty cable PVC insulated aluminium conductor seved with inner sheathing of PVC sheathed in service connections twin core cable lot of size 06 Sqmm 2 core all as specified and directed by Engr in charge Make : Polycab/Havells/Anchor
194Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out soil in soft/loose soil complete all as specified and directed.
195Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
196Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified& directed.
197Supply and laying of DWC (Double wall corrugated) pipe, ISI marked, having outer dia as 63 mm and inner dia as 50 mm for non pressure under ground cable including all connected accessories/fittings such as coupler, 'o' ring and suitable nos of clamp to fix with wall/roof/ceiling if required at site .etc. for protection of cable complete all as specified and directed by Engr-in-Charge.
198S&F in repairs Distribution board iron clad VTPN DB, with IP 43 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s, 4 way, complete. Make-Legrand or equivalent of make L&K / Siemens with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 10 KA and 04 nos SPN 32 Amp of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
199Taking down existing TPN DB of any size with due care and refixing with new lock bolt (where required) after cleaning/painting if required including connecting electrically using cables as required at site all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information
200Taking down existing TPN DB of any size with due care and refixing with new lock bolt (where required) after cleaning/painting if required including connecting electrically using cables as required at site all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58163316
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 55.53 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Ug Ops Infrasrtucture At 8Fbsu
Basic Detail
Tender No CWE(AF)SGR/AWA-35/2026-27
Bidding Type Tender
Location
City Pulwama
State Jammu and Kashmir
Key Dates
Publish Date 22 Oct 2026
Submission Date 18 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 55.53 Lakhs
Tender Fee 1000
EMD 1.08 Lakhs
Exemption Available
Document List
BOQ_891790.xls
f00b47b7-73b1-46c0-b6fd-699119ba84ff.html
TENDER35.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_891790.xls

html

f00b47b7-73b1-46c0-b6fd-699119ba84ff.html

pdf

TENDER35.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender