Tender For Repair / Maintenance Of Internal Electrification , Maintenance Of Acs, Water Cooler, Geyzer Etc At Cgdhq No 1 And Jetty Porbandar
Tender Value
25 Lakhs
Estimated cost
Bid Submission
11 Nov 2026
13 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Porbandar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Internal Electrification , Maintenance Of Acs, Water Cooler, Geyzer Etc At Cgdhq No 1 And Jetty Porbandar
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' |
| 2 | Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, fluorescent tube light fittings etc., to be measured and paid for separately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., complete all as specified and directed by Engineer-in-Charge. |
| 3 | Material & Labour for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc., including 1.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire Excluding modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules, complete all as specified and directed by Engineer-in-Charge.for the following:- |
| 4 | One light/ Bulb Holder /fan/exhaust point / bell point controlled by one, one way switch |
| 5 | One light point controlled by 2, Two way switch |
| 6 | One 5 pin socket outlet 5/6 amps on the same board. |
| 7 | One 5 pin socket outlet 5/6 amps on independent board. |
| 8 | All as per item No 2 above but with using 2.5 Sq mm single core multistanded copper conductor cable (FRLS)and 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 6 pin 16 Amp socket outlet on independent board . |
| 9 | Material & Labor for modular Point wiring using approved colour coding as per IS Red/Yellow/Blue, Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FR LS cable 1100 Volts grade ISI 694 marked with valid CML No. passing in PVC cassing-N-capping 25/32 mm fixed on surface of wall/roof/ceiling withexisting/with with pressed flush metal boxes covered with inner plates & outer plates / Surface modular box etc suitable for mounting of Modular switches & sockets including PVC insulated multi stranded copper conductor FRLS 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continully conductor to commonearth and connecting to earrth dolly complete all as specified and directed by Engr - in - Charge for the follwing. |
| 10 | One light /fan/bell point controlled by one, one way switch |
| 11 | One socket outlet 3 pin 5/6 Amps on same board |
| 12 | One socket outlet 3 pin 5/6 Amp on independent board |
| 13 | One light point controlled by two, two-way switches |
| 14 | All as per item No 4 above but with using 2.5 Sq mm single core multistanded copper conductor cable (FRLS)and 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 6 pin 16 Amp socket outlet on independent board . |
| 15 | Supply & Fixing of modular type 6 Amp one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & Fixing in replacement of modular type 6 Amp one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & Fixing of modular type 16 Amp one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply & Fixing in replacement of modular type 16 Amp one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply & Fixing in replacement of modular type 2/3 pin combined shuttered type 6 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply & Fixing of modular type 2/3 pin combined shuttered type 6 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply & Fixing in replacement of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply & Fixing of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply & Fixing in replacement of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply & Fixing of modular type 6 Amp bell-push conforming to IS: 8884- 1978 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply & Fixing in replacement of modular type 6 Amp bell-push conforming to IS: 8884- 1978 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply & Fixing in replacement of Bell multi music type 230 Volt, complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply & Fixing in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984, complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply & Fixing in replacement of 6 Amp, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply & Fixing in replacement of Modular switch 2 way 6 Amp, 1 module, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and fixing in replacement of Modular Flush box, complete all as specified and directed by Engineer-in-Charge of following size:- |
| 31 | 1 or 2 Module Metal flush box 85mm X 115mm |
| 32 | 3 Module Metal flush box 85mm x 115mm |
| 33 | 4 Module Metal flush box 85mm x 145mm |
| 34 | 6 Module Metal flush box 132mm x 135mm |
| 35 | Supply and fixing in replacement of Modular cover plate with frame, complete all as specified and directed by Engineer-in-Charge.of following size:- |
| 36 | 1 or 2 Module Modular cover plate with frame of size 85mm x 85mm |
| 37 | 3 Module Modular cover plate with frame of size 85mm x 115mm |
| 38 | 4 Module Modular cover plate with frame of size 85mm x 145mm |
| 39 | 6 Module Modular cover plate with frame of size 132mm x 135mm |
| 40 | Supply and fixing in replacement following items for maintenance of Internal Electrification 230V, complete all as specified and directed by Engineer-in-Charge. |
| 41 | Switch piano, flush type single pole, one way 5 Amp |
| 42 | Socket Outlet 2 in 1, 3 pin, 6 Amp flush type |
| 43 | Switch socket combination, 16 Amps flush type. |
| 44 | Switch piano, flush type single pole, one way 16 Amp |
| 45 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 16 way type, complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 4 way type, complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 6 way type, complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply and fixing in replacement of MCB,240V, 10KA B/Curve With connection testing and commissioning complete all as specified and directed by Engineer-in-Charge of following size:- |
| 51 | MCB 'C' curve 6 to 32 Amps single pole |
| 52 | MCB 'C' curve 32 Amps double pole / SPN |
| 53 | MCB 'C' curve 40 -63 Amps double pole / SPN |
| 54 | Supply and fixing in replacement of 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 55 | MCB, TP 25 to 63 Amps |
| 56 | MCB, TPN/FP 16 to 32 Amps |
| 57 | Material & Labour for sub-main wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in existing conduits / PVC Casing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, complete all as specified and directed by Engineer-in-Charge.NOTE: (02 ) Two run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Casing capping shall be measured as one length. |
| 58 | 2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire |
| 59 | 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire |
| 60 | 2 x 2.5 Sqmm + 1 x 4.0 Sqmm earth wire |
| 61 | Material & Labour for sub-main wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in existing conduits / PVC Casing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, complete all as specified and directed by Engineer-in-Charge.NOTE: (03 ) Three run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Casing capping shall be measured as one length. |
| 62 | 4 x 6.0 Sqmm + 2 x 4.0 Sqmm earth wire |
| 63 | 4 x 4.0 Sqmm + 1 x 2.5 Sqmm earth wire |
| 64 | Supply and fixing in replacement of casing capping of 25mm x 12mm size, complete all as specified and directed by Engineer-in-Charge. |
| 65 | Supply and fixing in replacement of casing capping of 32mm x 16mm size, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply & Fixing in repair of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. |
| 67 | Supply & Fixing in repair of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply & Fixing in replacement of LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply & Fixing in replacement of LED light 6 Watts surface/recess with multiple beam tilting angle no UV radiation white warm as peristing shape and size complete all as specified and directed by Engineer-in-Charge. |
| 70 | Supply & Fixing in replacement of square shape slim recessed mounted LED down light capacity 36 watt (2ft x 2ft) with die cast housing finished in white powder coating w/warm white as per existing shape and size complete all as specified and directed by Engineer-in-Charge. |
| 71 | Supply & Fixing in replacement of square shape mounted LED down light capacity 36 watt (2ft x 2ft) with die cast housing finished in white powder coating w/warm white as per existing shape and size complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply & Fixing in replacement of 80 Wattt LED bay light made of PDC aluminium housing with direct modular IP Lens, potted driver, 10 KV SPD, IP66 and with system efficay of 12lm/ including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge. |
| 73 | Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, painting of fan blade and body, repair of fan motor and replacement of worn out parts such as capacitor and bearing hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engineer-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately. |
| 74 | Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 75 | Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 76 | Dismantling of Exhaust fan Plastic Body 250/300mm motor, and replace with new motor and reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 77 | Supply and fixing in replacement of BLDC fan Printed circuit board(PCB) assembly with remote for 1200mm sweep suitable for existing, complete all as specified and directed by Engineer-in-Charge. |
| 78 | Supply only capacitor 2.5/3.15 mfd AC 230 volts for ceiling fans 1200/1400mm sweep and any make, complete all as specified and directed by Engineer-in-Charge. Make:- Epcos/ Unistar/ Usha/Bajaj or equivalent |
| 79 | Supply only capacitor 4 mfd suitable for exhaust fans 250/300mm sweep, complete all as specified and directed by Engineer-in-Charge. Make:- Epcos/ Unistar/ Usha/Bajaj or equivalent |
| 80 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator suitable for speed variation of BLDC fan and accessories such as remote , 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer-in-Charge. |
| 81 | Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and directed by Engineer-in-Charge. |
| 82 | Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ, complete all as specified and directed by Engineer-in-Charge. Note- worn out parts shall be measured as separately. |
| 83 | Supply & Fixing spare parts of Geyser |
| 84 | Supply only Heating element 1.5/2 KW with rubber gasket. |
| 85 | Supply only Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked. |
| 86 | Supply only Hot/Cold water connection pipe 450 mm length. |
| 87 | Supply only Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia |
| 88 | Supply only Indication lamp red and green suitable for geyser as required |
| 89 | 16 Amps top plug suitable as per existing socket |
| 90 | Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., complete all as specified and directed by Engineer-in-Charge. |
| 91 | Material & Labour for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush, refixing the front cover of indoor unit. Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressureized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of outdoor unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection, complete all as specified and directed by Engineer-in-Charge. Note:- Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule. Please Enable Macros to View BoQ information |
| 92 | Material & Labour for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush, refixing the front cover of indoor unit. Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressureized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of outdoor unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection, complete all as specified and directed by Engineer-in-Charge. Note:- Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender