Tender For Repairs And Maintenance To Old Street Lights At Test Track And Connected Documents Accessories Etc At Cvrde Avadi.
Tender Overview
Project Description
Tender for Repairs And Maintenance To Old Street Lights At Test Track And Connected Documents Accessories Etc At Cvrde Avadi.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-Nov-2026 | BOQ Corrigendum | BOQ | 10-Nov-2026 |
| 2 | 10-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-Nov-2026 |
| 3 | 03-Nov-2026 | BOQ Corrigendum | BOQ | 17-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking out old unserviceable under ground PVC/XLPE LT cable of any size from trenches/ wall/roof/road/pipe/pole including segregation of serviceable bricks for re-use complete all as specified and as directed. |
| 2 | Supply and Laying XLPE cable of size 16 sqmm 4 core 1100 Volt grade heavy duty aluminium conductor laid in trenches / fixed to wall / pole / laid in floorincluding necessary connection and suitable size lugs/glandsas required complete all as specified and as directed by Engineer-In-Charge. |
| 3 | Supply and Laying XLPE cable of size10 sqmm 4 core 1100 Volt grade heavy duty aluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size lugs/glandsas required complete all as specified and as directed by Engineer-In-Charge. |
| 4 | Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing LDPE pipe, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply and layng Low density polyet hylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc., no pipe joint between the cable complete all as specified and directed by Engr-in-Charge. |
| 6 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supplying, installation, Testing & Commissioning of 50 Watt Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -15 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-08, CRI >70, under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supplying, installation, Testing & Commissioning of 72 Watt Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -15 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-08, CRI >70, under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supplying, installation, Testing & Commissioning of 90 Watt Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -15 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-08, CRI >70, under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT, complete all as specified and directed by Engineer-in-Charge. |
| 10 | S&F in replacement of LED flood light not less than 100 Watts LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy not less than 100 lumen/watt, of 5700K with integral electronic driver, surge protection unit with suitable size GI bracket/clamps etc incl taking down HPSVMV/MH fittings complete all as specified and directed by Engg-in-Charge. |
| 11 | S&F in replacement of LED flood light not less than 150 WattS LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, of 5700K with integral electronic driver, surge protection unit with suitable size GI bracket/clamps etc required at site including taking down HPSVMV/MH fittings complete all as specified and as directed by Engg-in-Charge. |
| 12 | Taking down old unserviceable street light console of any type and Supply & fixing of Nature Switch Smart Timer based Automatic Street Light Control Panel. The Panel should be suitable enough to take Single-Phase load of 5kW (Navdeep-54-5kW1P) with: Contactor, Incoming MCB & Outgoing MCB rating of 32 Amps & main load Circuit Wiring (Copper) of min. 10 sq.mm. Nature Switch Smart Timer should be maintenance-free in design and settings accessible via a Mobile App (with Bluetooth connectivity). The Mobile App should allow users to customize the ON & OFF timings based on Natural Light (sensor), Local Sunset/Sunrise (Astro) and Time. The Mobile App should also have facility to set Input Voltage range. The Smart Timer along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Enclosure conforming to IP54. |
| 13 | Taking down the lanteren carrige assembly along with lanterns carefully after disconnection of all electrical connection etc and re-install the same carrying out necessary repairs like replacement of worn out pully at top section of high mast, welding, inserting the dislocated rope in pully groves in proper alignment for satisfactory operation of winch system, servicing the complete system by arranging necessary skilled workmen ship including necessary T & P required at site all as directed. (Note:-Cost of T&P used to carry out repairs of 16 Mtr height high mast is deemed to be included in unit rate and major spare shall be measure and paid seperatly). |
| 14 | Rewinding of motor 2 HP, 3 phase ,415 volts , 1425 RPM with copper wire of existing size including providing of insulating material, bearing, bush and greasing varnishing and properly packing of winding, re-assembling and testing complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply and fix in replacement of junction box made of inpact resistance plastic & heat resistant materials of size not less than 230x170x105mm, IP 66 protection, single left hinged door including provision of suitable terminal connector 16Amps capacity with MCB SP 6A and fixing to the surface/light pole with suitable sizes of clamps, nuts and bolts complete all as specifed and directed by Engineer-in-Charge. |
| 16 | Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size any core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable, providing required thimbles/connectors at cable end and reconnecting the cable with existing main NOTE: Additional cable/ protection pipe required at site shall be measured and paid seperatly. |
| 17 | Supply and fix in replacement of PVC insulated, PVC sheathed, 3 core multi stranded copper conductor of size 1.5 Sqmm for connecting to streetlight fitting passing through conduit fixed including taking down existing cable complete all as specified and as directed by Engineer-in-Charge.Note:- Conduit and coduit accessories shall be measured paid separately under respective item of this schedule |
| 18 | Supply and fix in repalcement of medium duty non matalic PVC conduit of 20 mm bore including all fitting such as bends, elbow, coupler lock nut etc, fixed along pole with suitable clamps (03 Nos each Pole), bolts, nuts etc for streetlight including taking down old PVC conduct of any type complet all as specified and directed by Engineer-in-Charge. |
| 19 | M&L for cleaning the steel tubular poles of any height and throughly with necessary cleaning agent including scrappin up of old corroded paint dirt/dust/ rust carefully and applying two coat of synthetic aluminium paint over one coat of red oxide metal primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including marking of pole numbers all as specified and directed by Engineer-in-Charge. |
| 20 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. complete all as specified and as required by Engineer-in-Charge. |
| 21 | Supply and fixing of Steel tubular swaged poles as specified type 410 SP-31 (9.0 metres long) complete with cast iron base plate, finial taper plug, along with single arm bracket complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material and Labour for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc., complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material and Labour for PCC 1:3:6 type C-2 using 20mm graded aggregate mechanically crushed stone for mass filling in stay pits and pole foundation., complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material and Labour for PCC 1:2:4 type B-2 using 20mm graded aggregate mechanically crushed stone for mass filling in stay pits and pole foundation, complete all as specified and directed by Engineer-in-Charge. |
| 25 | Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out complete al as specified and directed by Engineer-in-Charge. |
| 26 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade up to 35 sqmm direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender