Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #58163252

Tender For special Repair/ Replacement Of Water Supply Distribution Line And Associated Works In Flamming Arrow Bde Area At Nams

Issued by Statutory Bodies & Commissions/Committees · Amritsar, Punjab
Tender Value
45.63 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
11 days left
EMD
91268
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Amritsar → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for special Repair/ Replacement Of Water Supply Distribution Line And Associated Works In Flamming Arrow Bde Area At Nams

BOQ

Name of Work:- SPL REPAIR/ REPLACEMENT OF WATER SUPPLY DISTRIBUTION LINE AND ASSOCIATED WORKS IN FLAMMING ARROW BDE AREA AT NAMS
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth, for laying of GI / DI tubing in trenches and getting out in hard and dense soil complete all as specified by Engr-in-Charge.
2Returning filling in & including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
3Removing excavated material (soil) not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
4Taking up old U/S PP-R tubing from the site and obtained in sch of credit as recovered form the site complete as directed by Engr-in-Charge of following sizes :-
5PP-R tubing 100 mm bore
6PP-R tubing 80 mm bore
7PP-R tubing 50 mm bore
8PP-R tubing 25 mm bore
9Supply & laying of metalic tubing medium grade with all fittings (such as bend, Tee, elbow, socket, union, reducers, ferrule saddle etc) in trenches complete as directed by Engr-in-Charge, of following sizes ( Note when pipe laid in straight line then the 3rd length is required to be connected by union. ) :-
10DI pipe 100 mm bore
11GI tubing 80 mm bore
12GI tubing 50 mm bore
13GI tubing 25 mm bore
14Taking down old unserviceable air release valve of size up to 80/100 mm complete
15S&F air release valve with double air outlet on existing DI/GI pipe of bore 80 mm complete with drilling, threading, welding and fixing of GI pipe medium grade 80 mm bore all as per site requirement
16Description all as per item No 07 here in before but air release valve on DI/GI pipe of bore 100 mm complete
17Taking down old unserviceable CI sluice valve for 100/150 mm bore pipe complete
18Supply & fixing cast iron sluice valve for water supply purposes with CI drilled flanged end internally cast for 100 mm nominal bore class PN 1.6 horizontal type conforming to IS 760, ISI marked with stainless steel spindle & iron wheel non using type including jointing material complete such as rubber assertion packing rings with requisite no of nuts & bolts , washers of requisite size etc all as specified and directed by the Engr-in-Charge.
19Description all as per item No 10 here in before but sluice valve internally cast for 150 mm nominal bore
20Taking down old unserviceable gate valve /stop valve/ ball valve of any size complete.
21Supply and fixing gun metal, globe or gate valve for 25 mm bore pipe with iron wheel head screwed both ends ISI marked class 2 complete.
22Description all as per item No 13 here in before but 50 mm bore pipe complete.
23Dismantling of unserviceable valves pit of any size complete all as directed by the Engr-in-Charge.
24Construction of stone masonry valve pit chamber of size 90 cm x 90 cm x 150cm (internal dimensions) including all necessary excavation and earth work in hard/danse soil and disposal of surplus soil to distance not exceeding 50 meters and depositing the same as directed including PCC in foundation of the mix (1:4:8) type D-2 stone masonry in cement mortor 1:4 rendering 15 mm thick in cement mortor 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortor as of stone masonry, including mild steel frame (made out of angle iron 40x40x6mm ) MS steel cover 3.15mm thick with handle and locking arrangements with hinges angle iron , flat as required at site including painting of all the exposed MS work with two coats of synthetics enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminous paint and all other relevant work complete.
25Taking out cast iron non return valve (NRV) of any size complete all as directed by the Engr-in-Charge.
26Supply & fixing Non Return Sluice Valve for water supply purposes with CI drilled flanged end internally cast for 100 mm nominal bore class PN 1.6 horizontal type conforming to IS 760, ISI marked with stainless steel spindle & iron wheel non using type including jointing material complete such as rubber assertion packing rings with requisite no of nuts & bolts , washers of requisite size etc all as specified and directed by the Engr-in-Charge.
27Description all as per item No 18 here in before but Non Return Sluice Valve internally cast for 150 mm nominal bore
28Supply and installation in repairs, commissioning and testing Polycarbonate CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The Panel with dew guard moisture absorber feature. The manufacturer of panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing].
29INCOMER:a). 160 Amp, 4 pole MCCB, 25 KA 415V Adj. Thermal & Fixed Magnetic Released - 01 No,b). Digital Volt meter 0-500V with inbuilt selector switch - 01 No c). Digital Amp meter 0-200A with inbuilt selector switch & CT Coils- 01 Nod). Set of LED type indicating lamps - 01 No e). Copper Bus Bar 160Amp TPN
30OUTGOINGS: (f). 100 Amp, MCCB TPN 16KA 415 V,Thermal Magnetic Released - 02 Nos. (g). Automatic Start Delta Starter 40HP complete wiring with 2 Nos 80A TP Contactors and 1 No 50A with 1 Nos 55-65 Overload Relay, Single Phase Preventor, Start Stop Push Button with indicators, Digital Amp Meter for Each Starter - 1 Set (h). MCB TP 32A 10 KA C-Curve - 2 Nos with DOL Starters 3HP complete with Contactor, wiring and Start Stop Push Button with indicators. (i). MCB TPN 63A 10KA C-Curve - 2 Nos ( Lighting Load )
31M&L for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip of size 20 x 3 mm as earthing lead means of nut, bolts and washers made out of galvanised ireon mild steel and 40 mm dia GI pipe \\"light grade\\" for protection of earth lead and connected to contoll board or main switch or as directed by Engr -in-Charge including earthing pit in PCC (1:3:6) type C1 pre-cast cover RCC cover lab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and tesing complete. all as directed and specified by Engr-in-Charge
32Supply and fixing in replacement of automatic Smart Water level controller with sensor integration via screw terminals with the on field configuration for providing the option for underground sump and overhead tank, each indication for 5 Sensor reading per tank ( O%, 25%, 50%, 75%, 100%). Display interface with 4.3 TFT LCD screen with 32 Bit microcontroller unit, fixed resolution 480x 720 pixels. Operating Temperature for device -20 to 70 Degree C. The controller must support I/O based controls over 8 Bit 8051 Base Microcontroller Unit with support for Buzzer / Alarm at 25% and 100% capacity to operate On /Off operation. Manual override option to override the control from Auto Mode. The enclosure is made of ABS Material for IP protection. (Dust and water resistance) Make : sathya Sai or its eqivalents make as per E-in-C approved.
33Supply and fix in replacement of SS304 horizontal magnetic float switch with SS pipe for sensor mounting ( 5% Nos Sensor)
34Supply and fix in replacement of 1.1 mm x7 core outer dia 6.5 mm copper alloy signal cable with weather proof rubber coating
35Taking out old unserviceable/serviceable electric cable with stranded aluminium conductor, 1100 V grade cross-sectional area 70 Sqmm, 3.5 core from excavated trench complete all as specified and directed by Engineer-in-charge. .
36Supply and laying PVC insulated armoured heavy duty electric cable with stranded aluminium conductor, 1100 V grade cross-sectional area 70 Sq. mm, 3.5 core laid in trenches, ducts, fixing on walls with required clamps, cable glands, thimbles, jointing materials, insulation with proper colour coding etc. all as directed by Engr-in-Charge.
37M&L for factory made un reinforced precast concrete cable cover class LV type I, flat size 250mm x 150 mm x 40 mm, complete all as specified and directed by Engineer-in-charge.
38M&L for Sand cushioning to underground cables complete all as specified in Clause 19.75 of SSR Part-I laid before and after laying of cables, complete all as specified and directed by Engineer-in-charge.
39Supply installation testing and commissioning of a skid -mounted chemical dosing system comprising a heavy duty, motor-driven glandless mechanical diapharagm type dosing pump (25 LPH @ 10 kg/cm2) integrated with a 150-liter capacity vertical cylindrical FRP tank with lid, equipped with a top -mounted high speed electric agitator with SS -316L/ FRP coated aft and impeller, all mounted on a robust Mild Steel (MS) fabricated frame duly treated with two coats of epoxy based anti -corrosive paint, including a chemical -grade PVC Non return valve (NRV), a centralized electrical control penel with independent starters for pump and agitator, indicator lamps and overload protection, and all necessary internal suction/ discharge chemical grade piping and fittings , complete as per standard engineering practice.
40Supply, installation , testing and commissioning of LED Aviation Obstruction Light complete with all accessories , mounting at Over Head Tank upto height 30 meter and necessary fixing arrangement as required for proper operation all as specified and directed by Engr-in Charge.
41S & F Wiring for circuit/submain wiring alongwith earth wire with the sizes 2x4.0 sq. mm + 1x2.5 sq. mm earth wire in PVC conduit copper conductor, single core cable in surface/ recessed as required
42Construction of brick masonry for lorry water filling point piller of size 34 cm x 34 cm x 300cm including PCC in foundation of the mix (1:4:8) type D-2 brick masonry and earth work in hard/danse soil and plastering 1:4 rendering 15 mm thick in cement mortor all as specified and directed by Engr-in-Charge
43Material & labour taking out CI/DI pipe flanged type 150 mm dia of rising main/delevery/over flow/wash out of OHT of height 30 mtr arresting for leakage , repair the leakage by replacing CI/DI pipe flanged type 150 mm dia complete with all accessories like rubber gasket, nutbolts and necessary fixing arrangement complete all as specified and sirected. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58163252
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45.63 Lakhs
LAST DATE 12-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair/ Replacement Of Water Supply Distribution Line And Associated Works In Flamming Arrow Bde Area At Nams
Basic Detail
Tender No GE NAMS-95/2026-27
Bidding Type Tender
Location
City Amritsar
State Punjab
Key Dates
Publish Date 22 Oct 2026
Submission Date 12 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 45.63 Lakhs
Tender Fee 500
EMD 91268
Exemption Not Available
Document List
1cd8a563-70d5-4f13-8383-e1d40c0d36db.html
95T.pdf
BOQ_891717.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

1cd8a563-70d5-4f13-8383-e1d40c0d36db.html

pdf

95T.pdf

xls

BOQ_891717.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender