Tender For Repairs To Internal / External Plastering, Chajjas, Seepage Treatment To External Walls Etc, Roof Treatment And Connected Works In Zone B And E Under Ge Chennai
Tender Overview
Project Description
Tender for Repairs To Internal / External Plastering, Chajjas, Seepage Treatment To External Walls Etc, Roof Treatment And Connected Works In Zone B And E Under Ge Chennai
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Laying of CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors including pipe fittings and including taking up or down in the existing pipe line complete all as specified and as directed for pipe of 32mm outer dia. |
| 2 | M & L in repair Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25 mm dia bore pipes complete all as specified and as directed. |
| 3 | S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 1000 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed. |
| 4 | S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 500 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed. |
| 5 | M & L for Cutting holes into or through brick walls built in cement mortar and making good in PCC (1:2:4) type B-1 as required Superficial area not exc 150 Sq CM complete all as specified and as directed. |
| 6 | Cutting holes into or through brick walls area exc 150 sqcm but n.exc 400 sqcm built in lime mortar and stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and as directed. |
| 7 | S & F PVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints fixed to walls /floor as in spouts etc complete including dismantling existing pipes complete all as specified and as directed. |
| 8 | M&L for Preparation of Existing surfaces of walls/chajjas/facia etc to remove all dirt, mildew and other contaminants. Treat areas affected by Algae, moss or fungal growth with biocide wash solution and pressure cleaning equipment with a minimum capability of 100-140 bar water pressure. All grease, oils and asphalt materials must be removed completely. All surface cracks up to 5 mm width should be filled up with Dr. Fixit Crack-X or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP.Cracks more than 5 mm and all separation gaps should be filled up with Dr. Fixit Pidicrete URP modified mortar or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP. Priming using Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP diluted in 2:1 ratio with water (2 parts Prime seal diluted with 1 part water) @ 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs. Apply one coat of Dr. Fixit Raincoat Waterproof Coating or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP without dilution by brush or roller for walls at the thickness of 120 – 130 microns all as specified and directed .Note: All above treatment will be measured as one unit of square metre and paid accordingly. |
| 9 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 10 | M&L for fly ash old size brick work straight or curved on plan exc 6M mean radius built in CM 1:6 complete all as specified and as directed. |
| 11 | Taking down cement plaster of any description on brick or stone walls or from concrete wall / ceiling surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cantt area, complete all as specified and directed. |
| 12 | GI wire netting 0.90mm dia and12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc., including all laps, cutting and waste complete all as specified and directed. |
| 13 | Dubbing out average 15mm thick on irregular face of walls in patches in CM (1:4) complete all as specified and directed. |
| 14 | M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces of walls etc 10 mm thick in CM 1:6 and 5 mm thick in CM 1:4 incl water proofing compound as per manufacturers instruction & finished the surfaces even and smooth without using extra cement, complete all as specified and directed. Note : WPC WILL BE MEASURED AND PAID SEPERATELY |
| 15 | Supply only Liquid water proofing compound complete all as specified and as directed. (Make SIKA/FOSROC/CHOKSEY) |
| 16 | Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls all as specified and as directed by the Engineer-in-Charge. Make : APEX of Asian or equivalent of Shalimar / Nerolac/ Berger. |
| 17 | M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and as directed. |
| 18 | Complete removal of existing roof treatment including vegetation and plants any type and demolition of cement concrete padding at roof slab n exc 15cm thickness complete all as specified and directed. |
| 19 | M & L for plain cement concrete 25mm thick average thickness as roof padding type B0, 1:2:4 (12.5mm graded aggregate) finished fair and even over concrete surface on roof top, and finished even and smooth with 10mm thick cement plaster in CM 1:4 mixed with WPC @ 200 ml per bag, when the concrete is green all as per manufacturer instructions and as specified and as directed. ( Note: Water proofing compound will be paid under measured separately) |
| 20 | Cleaning and preparation of newly plastered roof surfaces and applying the water proofing treatment as under.(a) Applying 1st course of bituminous (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed.(b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm.(c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on roof surfaces complete all as specified and directed. |
| 21 | M&L for preparation of the surface thoroughly by cleaning, washing and removing dust, dirt, oil, grease and loose particles in existing old terraces with brick bat coba or screeds, damaged or hollow portions, sharp edges, etc. shall be cut and removed till the mother slab is exposed and washing down with clean water to remove all dirt etc., The slab shall be recoated with slurry of Dr. Fixit Pidicrete URP or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP and cement in 1:1 proportion. After drying, the surface cracks shall be filled with Dr. Fixit. Crack-X or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP or polymer-modified mortar in case cracks are wider than 5 mm.Cracks less than 2 mm, shall be cleaned free of dust with a vacuum cleaner.Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be applied in the crack and shall be allowed to dry. Dr. Fixit new coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be then poured into these cracks and shall be allowed to dry . Bitumen based waterproofing treatments if existing, must be completely removed by mechanical scarification or by any other effective mechanical means. 2 parts of Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be diluted with 1 one part of water. This dilution will cover 7 to 8 sq.mt and shall be allowed to dry for 6 to 8 hrs. First coat of Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be applied without any dilution at the rate of 2 m2 per litre and shall be allowed to dry before taking up the second and third coats, the rate of application being the same and open woven glass fibre mesh of 2.5 mm x 2.5 mm must be sandwiched between the first and second coat. While the 1st coat is still wet, the fibre mesh shall be placed on it. After the coat dries, the 2nd coat of Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC- |
| 22 | Note for Srl Item No 21.00:a) All movements in cracks and cold joints in the substrate caused by variations of high and low temperatures shall be taken care.b) This reinforcement with fibre mesh shall be extended up to the drip mould over the angle fillets. c) The sequence of colours of Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP. can be decided depending on the desired top coat colour. Drying time between coats will be 6 to 8 hrs. d) The system may be allowed to air cure for 7 days minimum. e) A total film thickness of 1 to 1.2 mm must be achieved when measured after drying.d) 7 days after application of Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP, it should be checked for its adhesion to the substrate. For this, a square of 5 cm x 5 cm shall be marked for every 200 sq. m of the area. Cut the square with a knife diagonally across the square. Rip the coating and check the coating’s thickness with vernier callipers, to see if the dry film has an average thickness of 1 mm. This should be done in every 200 m2.over the entire roof. Once these tests are done, reapply New coat over these portions, in accordance with the Dr. Fixit New coat or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP. all as specified and directed |
| 23 | M&L for apply a tack coat of bitumen 85 /25 at the rate of 1.20 Kg /Sqm on roof surfaces including cleaning of surfaces in patches including sealing the open joints in the water proof felt including one coat solar reflective f aluminium painting @ .10 Lit per sqm on repaired portion complete all as specified and directed |
| 24 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed. |
| 25 | Taking down of existing cement or lime plaster along with the existing water proofing treatment on walls and applying 10 mm thick cement plaster 1:3 mixed with liquid Water Proofing Compound @ 200 ml per bag, cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under. (a) Applying 1st course of bituminous (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed.(b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm.(c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed. Note : WPC WILL BE MEASURED AND PAID SEPERATELY |
| 26 | Dismantling plain or corrugated steel sheeting any gauge, any thickness, including nainital or similar pattern roof covering complete all as specified and as directed. |
| 27 | S&F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 28 | S&F pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 29 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 30 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-B complete all as specified and as directed. |
| 31 | S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 32 | S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. Fe-410- W(Gde- E-250) quality- B(cut to ordinary lengths i.e. Within 20mm of the length indicated) complete all as specified and as directed. |
| 33 | M&L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surface based materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces complete all as specified and as directed. |
| 34 | M & L for Preparation of new steel surfaces and applying two coats of black bituminous paint over a coat of red oxide on steel or iron surface based materials of any description , not other wise described over 10 cm width or girth complete all as specified and as directed |
| 35 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 36 | M & L for Precast cement concrete 1:2:4, type B1 using 20mm graded stone aggregate in water tank staging base slabs set in CM 1:6 complete all as specified and directed. Note : Reinforcement will be measured and paid seperately. The rate is deemed to include for removal of debris outside MD Land. |
| 37 | M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents