Tender for State Plan-State Plan 2026-27- Optimization Of Electro Mechanical Items, Energy Efficiency Improvement , Safety Audit And Ensuring Safety In Operation Of Wtps And Pump Houses- Rwss To Poonjar Thekkekara- Erection And Commissioning Of 40 Hp Submersible Pump Set, Renovation Of Pump House-Erection And Commissioning Of 40 Hp Submersible Pump Set, Renovation Of Pump House-General Civil Work
BOQ
| Sl. No. | Item Description |
| 1 | RWSS to Poonjar Thekkekkara, renovation of well cum pump house |
| 2 | 12.1.3:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 3 | 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 4 | 50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete |
| 5 | 13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 6 | 10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
| 7 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 8 | 15.13.1:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below |
| 9 | 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) |
| 10 | 50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete |
| 11 | 21.1.1.3:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron ) |
| 12 | 21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 13 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 14 | 4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 15 | Supply and Erection of 40 HP Submersible Pumpset |
| 16 | OD257345/2025-2026:Supplying, erection and commissioning of new Submersible pump set of KWA prequalified reputed make with bronze/ stainless steel impeller , SS shaft with suitable ss coupling having a head of 200m and discharge of 8 lps with required capacity motor with90 %efficiciency suitable for the submersible pump with suitable speed rpm as per IE/KSEB specifications, , Erection , testing and commissioning of suitable rating fully automatic starter with air break contact suitable for the above motor with over voltage and under voltage protection, phase sequence relay, single phasing preventer, Dry run protection ,over load relay with motor protection relay with main contactor and bypass contactor as per CEA regulations and code of practice etc.complete.. Panel board (Suitable for operating two pump sets but one pump set at a time)Supply, Design, fabrication, erection, testing and commissioning of Cubicle type,floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer , Suitable capacity change over switch for operating stand by pump ,and 2 Nos. of suitable capacity MCCB as out going(the two MCCBs are interlocking with each other) providing suitable size aluminium/copper bus bar to interconnect the above MCCBs and fitted with 3 Nos. of indicator lamps, 1 No. volt meter with selector switch etc. complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. . Cabling work, Supply, erection , testing and commissioning of suitable size XLPE cables for the above pump set panel board to starter and from starter to motor, considering energy conservation. EarthingSupply of all materials and providing suitable earthing by using suitable size pipe or plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per CEA regulation .. CapacitorSupply, erection , testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall conform to IS 2834. ValvesSupply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and non - return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for non - return valves.. Supply and erection of suitable pressure gauge( Fluid filled) ,Supplying suitable gauge PVC insulated single core copper cable of suitable size and cable termination materials such as cable socket, cable box for working motor as per IE/KSEI/KSEB specifications including capable for bearing starting load for connecting meter board to panel board and panel board to starter and starter to motor and supply of column pipe and delivery pipe line for connecting existing delivery line required length and size as per site conditions, Erection of pump set, motor , starter , mobile operated automatic control unit ,column pipe and all other items supplied,including all labor charges for the erection of pump set, fixing the motor providing cableconnections from meter board to panel board, panel board to starters, starter to motor, earthingall electrical equipment as per IE rules and regulations and electrical inspectorate specifications;fixing power capacitor and fabricating y type delivery pipe line and connecting to two numbers pump delivery pipe line if it is necessary including all welding charges etc. and dismantling , for the satisfactory commissioning of the pump set, including including all works such as providing clamp cross bars 1 nos , all civil works such as dismantling the existing unused pump set if it is required and making good the dismantled and all incidental works satisfactorily completion of works etc. complete and taking trial run. Total warranty shall be limited to five years. |
| 17 | OD257365/2025-2026:Supply of automatic Star delta starter with suitable rating for the motor. Total warranty shall be limited to five years. |
| 18 | OD257369/2025-2026:Supply and installation of GSM based three phase motor controller , The three phase starter should be able to operate from the mobile phone application interface. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender