Tender For Supply, Installation, Testing & Commissioning (Sitc) Energy Storage System For Existing Uninterrupted Power System At Aditi, Iucaa, Pune

Issued by Boards / Undertakings / PSU · Pune, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Nov 2026
19 days left
EMD
1.11 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Offline

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Supply, Installation, Testing & Commissioning (Sitc) Energy Storage System For Existing Uninterrupted Power System At Aditi, Iucaa, Pune 1 Design, Manufacture, Supply And Irection Of Structurally Sound, High-Load-Bearing And Modular Battery Rack Systems Fabricated From Mild Steel (Ms)/Carbon Steel Sections, Using L-Angle/Square Sections Of Size 40 × 40 × 4 Mm Or Suitable Equivalent Section As Per The Required Load Capacity And Site Compatibility. The Scope Shall Include Cutting, Drilling, Welding, Grinding, Fabrication, Leveling, Alignment, Provision Of Suitable Supports/Bracing And Anchoring Arrangements, As Required At Site. Suitable Heavy-Duty Rubber Pads Of Adequate Thickness And Load-Bearing Capacity Shall Be Provided Below The Battery Rack/Supporting Contact Points To Provide Load Isolation, Minimize Vibration And Prevent Direct Metal-To-Floor Contact. The Complete Rack Shall Be Properly Surface-Prepared, Treated Against Corrosion And Finished With Durable Powder Coating. The Rack Shall Be Designed To Safely Accommodate The Specified Battery Quantity And Load, With Adequate Structural Strength, Stability, Ventilation And Accessibility For Inspection And Maintenance. The Work Shall Be Complete In All Respects As Per The Approved Design, Site Conditions And Engineer-In-ChargeS Instructions. 495 Kg. 2 Supply, Laying & Testing Of Single Core, 95 Sq. Mm, 1100 V Grade, Frlsh, Multi-Stranded, Flexible Copper Conductor Cable Conforming Tois 5831:1984 (Latest) With Isi Mark, Pvc Insulated, Sheathed, Erected On Provided Wall/ Trusses/Pole/Cable Trays /Trench/ Pipe Suitable For Industrial Use, Including Necessary Fixing Arrangements, Cable Ties & Cable Management, Ferrules, Dressing, And Testing As Required At Site. 240 Mtr. 3 Termination Of Single Core, 95 Sq. Mm, 1100 V Grade, Frlsh, Flexible Copper Conductor Cable Using Suitable Tinned Copper Crimping Lugs & Heavy Duty Cable Gland (Is:12943) At Panel End (Is:8309/Is:8337), Including Cutting, Stripping, Dressing Of Cores, Crimping, Fixing, Earthing, Tagging, And Making Complete Termination At Both Panel And User End As Required At Site. Etc.

AI Tender Summary

OUR REF NO 58155895
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 11-11-2026
Authority
Authority Name inter-university centre for astronomy and astrophysics
Work Description Tender For Supply, Installation, Testing & Commissioning (Sitc) Energy Storage System For Existing Uninterrupted Power System At Aditi, Iucaa, Pune 1 Design, Manufacture, Supply And Irection Of Structurally Sound, High-Load-Bearing And Modular Battery Rack Systems Fabricated From Mild Steel (Ms)/Carbon Steel Sections, Using L-Angle/Square Sections Of Size 40 × 40 × 4 Mm Or Suitable Equivalent Section As Per The Required Load Capacity And Site Compatibility. The Scope Shall Include Cutting, Drilling, Welding, Grinding, Fabrication, Leveling, Alignment, Provision Of Suitable Supports/Bracing And Anchoring Arrangements, As Required At Site. Suitable Heavy-Duty Rubber Pads Of Adequate Thickness And Load-Bearing Capacity Shall Be Provided Below The Battery Rack/Supporting Contact Points To Provide Load Isolation, Minimize Vibration And Prevent Direct Metal-To-Floor Contact. The Complete Rack Shall Be Properly Surface-Prepared, Treated Against Corrosion And Finished With Durable Powder Coating. The Rack Shall Be Designed To Safely Accommodate The Specified Battery Quantity And Load, With Adequate Structural Strength, Stability, Ventilation And Accessibility For Inspection And Maintenance. The Work Shall Be Complete In All Respects As Per The Approved Design, Site Conditions And Engineer-In-ChargeS Instructions. 495 Kg. 2 Supply, Laying & Testing Of Single Core, 95 Sq. Mm, 1100 V Grade, Frlsh, Multi-Stranded, Flexible Copper Conductor Cable Conforming Tois 5831:1984 (Latest) With Isi Mark, Pvc Insulated, Sheathed, Erected On Provided Wall/ Trusses/Pole/Cable Trays /Trench/ Pipe Suitable For Industrial Use, Including Necessary Fixing Arrangements, Cable Ties & Cable Management, Ferrules, Dressing, And Testing As Required At Site. 240 Mtr. 3 Termination Of Single Core, 95 Sq. Mm, 1100 V Grade, Frlsh, Flexible Copper Conductor Cable Using Suitable Tinned Copper Crimping Lugs & Heavy Duty Cable Gland (Is:12943) At Panel End (Is:8309/Is:8337), Including Cutting, Stripping, Dressing Of Cores, Crimping, Fixing, Earthing, Tagging, And Making Complete Termination At Both Panel And User End As Required At Site. Etc.
Basic Detail
Tender No 19/10/2026
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 22 Oct 2026
Submission Date 11 Nov 2026
Open Date 12 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 1000
EMD 1.11 Lakhs
Exemption Not Available
Document List
aeee9553-405c-4109-950d-d11bc4195d18.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 11, 2026
17:00 IST

Bid Submission Deadline

Offline submission at the designated office.

Upcoming · 19 days
Nov 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
pdf

aeee9553-405c-4109-950d-d11bc4195d18.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender