Tender For Estimate For Strengthening Of Seraikella Urban Water Supply Scheme By Supplying , Installation And Commissioning Of Hsc Centrifugal Pump-Motor Set Having Discharge 196M3 /Hr , Head 70M And Its Allied Accessories At Wtp Of Seraikella Under
Tender Overview
Project Description
Tender for Estimate For Strengthening Of Seraikella Urban Water Supply Scheme By Supplying , Installation And Commissioning Of Hsc Centrifugal Pump-Motor Set Having Discharge 196M3 /Hr , Head 70M And Its Allied Accessories At Wtp Of Seraikella Under D.W.&. S Mechanical Division,Chaibasa.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-Oct-2026 | terms and condition of BOQ | Technical Bid | 29-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supplying all labour tools and tackles for taking out old and damaged C/F pump set with all accessories, demolition of foundation for installation of new HSC centrifugal pump sets. |
| 2 | Supplying all labour tools and tackles for making PCC foundation-1 no. of size 6'x3'x2' with all materials such as cement, sand, stone chips, J-type foundation nut ,bolt with washer of M36-6nos, MS base frame-1 no, cutting and welding where necessary ,plastering and punning over exposed surface etc all complete job. |
| 3 | Supplying, Installation, testing and Commissioning of single/multi stage electrically driven Horizontal split casing Centrifugal pump(make KIRLOSKAR/WPIL/ WILO/M&P/JYOTI) as per IS:5120, Capable for Discharge 196m³/hr and Head 70m, consisting of Stainless Steel/Bronze impellers, stainless steel pump shaft, tyre coupling with all accessories coupled with energy efficient (IE3) TEFC Squirrel cage induction motor confirming to IS:12615 operating on 1480 rpm, 415+10% volts, 3 phase, 50HZ (make Kirloskar/ABB/CGL) all complete with required size of sluice and nonreturn valve, strainers, reducers, foot valve, pressure gauge, MS delivery and Suction pipe, common header, nuts and bolts, packing, fitting and fixing, labour and technician, etc all complete job as per site requirement.Note:-(1). Motor capacity should have 20% above of the pump. (2). Pressure gauge must be fitted in delivery pipe with all accessories . |
| 4 | Cost towards making suitable suction line By suppling of M6 Pipe, Bend, Flange, Nut, Bolt, Rubber insertion, including making hole for suction, cutting, welding etc all complete job. |
| 5 | Cost towards making suitable delivery line By suppling of M6 Pipe, Bend, Flange, Nut, Bolt, Rubber insertion, including joining the new delivery line to the existing header by means of cutting, welding etc all complete. |
| 6 | Main Power Distribution Panel cum MCB for Clear Water to be installed at WTP-Floor mounted cubical LT Motor Control Panel board fabricated with MS sheet of suitable guage and size dust and vermin proof and painted consisting of proper power distribution 4 pole 630A copper busbar, 1 no incoming feeder of 630A ACB(make L&T/Siemens/ BCH), 4 nos. 240A MCCB (make L&T/Siemens/BCH) for outgoing feeder of clear water pump sets (with spare feeder). 2 nos 160 A & 63 A MCCB(make L&T/Siemens/BCH) for WTP & other Utilities, 2 nos. 32 A MCB(make L&T/ Siemens/BCH) for lighting feeder, 400A switch disconnected isolator (TPN) (make L&T/Siemens/BCH), 630A change over switch (make L&T /Siemens/BCH), selector switches, Volt-meters (ISI Marked, 0-500V), Ampere-meters (ISI Marked, 0-200A), indicator lamps etc all complete with internal wiring, protection units/relays and capacitor banks of proper KVAR for Power Factor improvement for pump sets and other equipments, etc. all complete as per site requirement. Instruction of E/l and IE rules. APFC panel not less than 75 KVAR with all complete accessories. |
| 7 | Providing erecting and commissioning of assembled fully automatic star delta starter in a provided cubical pannel to operate squirrel cage induction motor working on 380-440 Volt, 3 Phase, 50 Hz with no volt coil, over load relay and ON/OFF push buttons, with necessary material and connected to supply etc complete (Make-BCH/kirloskar/L&T/Siemens/Jyoti etc). |
| 8 | Servo controlled Automatic voltage stabilizer : supplying Installation, testing & commissioning of 200 KVA servo controlled Automatic voltage stabilizer suitable for out put voltage of 415 volt +/-1%, 3 ph. 50 Hz with copper wound transformer (oil cooled). The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. protections and indications shall be incorporated with over voltage/ under voltage, single phasing & cut off contactor with electronic output sensing unit, including T-oil, 400A change over switch (make L&T /siements), etc all complete (Output-415±1%, Input-280 to 450/460V). |
| 9 | Providing, erecting, and commissioning of power wiring with required 70 sq. mm. 3.0 core 1.1 kV grade unarmored copper cable XLPE/PVC insulated from panel to motors including laying on wall or on floor as where required, jointing, and making proper termination kit etc all complete job (ISI mark). As per IE rules. |
| 10 | Providing, erecting, and commissioning of power wiring with required 240sq. mm. 3.5 core 1.1 kV grade armored Aluminium cable XLPE/PVC insulated from transformer to motor control panel including laying on wall or on floor as where required, jointing, and making proper termination kit etc all complete (ISI mark).As per IE rules. |
| 11 | Cost for supply and fitting of 400Amp. TPN main switch/Switch disconnector(make L&T/siements) and doing all line connection. |
| 12 | Earthing with copper earth plate 600mm x 600mm x3mm thick including accessories and providing masonry with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal/ coke and salt as required for chemical earthing. |
| 13 | Supplying and laying of 8 SWG copper wire for making earthing connection in to from earthing station to panel, motor and Servo Stabilizer. |
| 14 | Providing, erecting triple spur gear type chain pully block suitable for 5 Tonne capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift tested to 50% overload as per IS-3832 carrying ISI mark with travelling trolley. |
| 15 | Supplying, installation and commissioning of lightening arrestor for pump house, fire fighting system-02 nos, first aid-02 nos, rubber matting-02 nos for electrical equipments etc for pump house. |
| 16 | GST (18%) |
| 17 | Labour Cess (1%) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender