Housing Urban and Rular Development Government Departments Closing in 1 days TDR #58154425

Tender For Construction Of Sub Centre At Ainoo Advt.Cost=₹ 64.33 Lacs, Amount Without Gst= ₹54.52 Lacs, Gst Amount= ₹9.81 Lacs

Issued by Government Departments · Anantnag, Jammu and Kashmir
Tender Value
64.33 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
1 days left
EMD
1.28 Lakhs
Bank guarantee accepted
Document Fee
1600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Sub Centre At Ainoo Advt.Cost=₹ 64.33 Lacs, Amount Without Gst= ₹54.52 Lacs, Gst Amount= ₹9.81 Lacs

BOQ

Name of Work:- Construction of Sub Centre at Ainoo Advt.Cost=₹ 64.33 lacs, Amount without GST= ₹54.52 lacs, GST amount= ₹9.81 lacs
Sl. No. Item Description
1Construction of health sub centre. Earth work in excavation by manual/Mechanical means over areas exceeding 30 cms & upto 5 m in depth 1.5m in width as well as 10 sqm. On plan, disposal of excavated earth upto 1 m, disposed earth to be levelled & neatly dressed( all kinds of soils
2Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete
3Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40mm nominal size crushed stone agg.)
4P/L in position specified grade of reinforced cement cencrete excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. 1:1.5:3 graded stone agg. 20mm nominal size
5Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:2:4 coarse sand 20mm nominal size crushed stone agg.)
6Centring and shuttering of kit ply including proping, strutting & removal of the same.
7P/F exposed quality shuttering using Kitlpy/steel sheets incld cost of all fittings complete job
8Brick work with FPS bricks of class designation 75 in foundtion & plinth in cement mortar 1:6 (1 cement, 6 coarse sand) i/c extra for Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto floor V walls
9B/w for SEPTIC TANK
10Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position first class imported wood (IMPORTED GERMAN WOOD)
11Providing & fixing panelled or panelled & glazed shutters for doors & windows and clerestory windows including ISImarked black enamelled M.S Butt hingeswith necessary screws excluding panelling using imported wood 35mm thick
12Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. : in Imported wood
13Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : imported wood 35mm thick
14Providing & fixing of 40x5mm flat iron hold fast 40cm long including fixing to frameswith 10mm dia bolts nuts &wooden plugs and embedding in cement conc block 30x10x5cm 1:3:6mix (1cement:3coarse sand:6 graded st agg)20mm nominal size
1515mm Cement Plaster on the rough side of single or half brick wall of mix 1:6(1 cement:6 fine sand)
1612mm Cement Plaster of mix 1:4(1 cement:4 coarse sand)
17Providing and laying Ceramic glazed floor tiles (thicknessto be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown (KAJARIA, JOHNSON , NITCO OR EQ BRAND)
18P/L Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge:Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
19Extra for providing glass panes of ordinary glass panes windows and clerestory window shutters wt 10 Kg/sqm (Area of opening for glass panes excld portion inside shall be measured):3.5mm thick
20Providing and applying white cement based putty of specified thickness(1-2mm), of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
21Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications
22Priming coat with ready mixed Pink or grey primer of approved brand and manufacture on WOOD work (hard or soft wood)
23Painting with synthetic enamel paint of app. Brand & manufacture to give an even shade 2 or more coats on new work
24Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm)
25Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars)
26Structural steel work in builtup section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
27P/F track deck crill make or equivalent H.I rib color coated profiled sheets 1000 to 1020mm cover width 28-35mm high crests at 250 to 255mm TCT (total coated thickness) high tensile SMP Galvalume steel with silicon modified ployester coating of approved colour of total thickness of 35 micron comprising 20 micron exterior coat of SMP over 5 micron polyester back coat over 5 micron primer coats on both surfaces incld. side and end lap and using 8mm galvalume hex self drilling fastener on each crest of sheet for connection with purlins and seam bolts at 300mm centers on all side and end laps etc. (measured for unit of laid area)0.50mm THICK (TATA DURASHINE, JSW COLORON PLUS OR EQ) I/C ALL CARRIAGES
28Providing ridges of hips of width 60cm overall width color coated plain sheets fixed with self drilling screws with EPDM Seal complete: 50mm thick
29Providing and fixing soffit under roofs i/c framework using 0.35mm ribbed color coated profile sheets complete
30P/F ISI marked ornamental aluminium(coated) hardware fittings i/c all fastenings complete L-drop with in built-lock
31Handles 200mm
32Handles 100mm
33T Bolts 100mm
34T Bolts 150mm
35Hooks
36P/F of MS railings&Grill using angles , hollow tubes ,pipe sections etc including welding,fixing in position , p/a priming coat and 2 coats of epoxy paint and all necessary fittings complete as per directions of engineer in charge
37Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth. Granite Stone of approved shade
38Providing and fixing water closet squatting pan (Indian type W.C. pan with 100mm P or S trap, 10 litre low level white P.V.C. flushing cistern half/full push mechanism , including flush pipe, conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (HINDWARE/CERA/KEROVIT make)
39Providing and fixing pedestal supported wash basin with C.I. brackets,including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm (HINDWARE/CERA/KEROVIT make)
40Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: :One urinal basin with 5 liter white P.V.C flushing cistern.
41Providing and fixing of mirror with built in shelf of superior quality (HINDWARE /RESPITE/JOHNSON make) with all fittings and fixtures complete.
42Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. PN-16 pipe , 25mm OD(SDR-7.4)
43Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. PN-16 pipe , 32mm OD(SDR-7.4)
44Providing and fixing C.P. brassbib cock of approved quality (JAQUAR /JOHNSON /CERA /KEROVIT make) conforming to IS standards:15 mm dia. nominal bore
45Providing and fixing C.P. angle cock of approved quality (JAQUAR /JOHNSON /CERA /KEROVIT make) conforming to IS standards:15 mm dia. nominal bore
46Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked(SINTEX HEAVY DUTY) with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
47Providing and fixing ball valve approved quality conforming to IS standards:20 mm dia. nominal bore
48Providing and fixing of Towel rail of superior quality with all fittings and fixtures complete
49Providing and fixing MS grating of approved quality and colour. 100 mm nominal dia.
50Providing and fixing Polyvinyl Chloride (PVC) pipes(PRINCE TYPE-B HEAVY DUTY), incl all PVC plain fittings This includes jointing of pipes ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. 100mm
51Constructing masonry main holes 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. complete job
52Providing and fixing of soap dish holder (JAQUAR make) with concealed fittings etc.
53P/F Hot water geyser (50 ltr capacity) of approved design and make i/c all fittings complete
54P/F Basin Mixer of standard make(JAQUAR/CERA or equivalent) as per specifications complete
55P/F sink Mixer of standard make(JAQUAR/CERA or equivalent) as per specifications complete
56Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm
57Providing and laying Ceramic glazed wall tiles (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make(KAJARIA, SOMANY, JOHNSON make) , in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete
58Carriage of materials By Mech.Transport, from source to site of work for 30km avg lead sand/ bajree item
59Bricks
60Construction of Boundary Wall Earth work in excavation by mechanical means in trenches for foundations drains , pipes , cables etc. ( exceeding 1.5 m in width ) and for shafts , wells , cesspits and the like not exceeding 10 sqm on plan depth up to 1.5 m incld. disposal of excavated earth up to 1 m from cutting edge disposal earth is to be leveled and neatly dressed(all inds of soil)
61P/L Stone soling/RBM i/c leveling , conslidation with 8-10T PRR including cost andcarriage of all materials involved (complete job).
62Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
63Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
64Centring and shuttering i/c strutting and propping i/c removal of formwork for foundations etc
65Reinforcement for RCC work i/c straightening cutting bending placing etc TMT bars Fe-500 or above
66Brick work with FPS bricks of class designation 75 in foundation & plinth in cement mortar 1:6 (1 cement, 6 coarse sand) i/c extra for Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto floor V
67Structural steel welded in single sections trusses and framed work incld cutting hoisting fixing in position and applying a priming coat of approved steel primer/ paint all complete
68Clearance of site i/c removal of undulations/ removal of debris by engaging JCB and Tractors i/c disposal of rubbish for all leads as directed by engineer incharge
69Carriage of materials By Mech.Transport, from source to site of work for 30km avg lead sand/ bajree item
70Bricks
71Electric part: Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V GA modular switch , modular plate and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEl/RR or equivalent make ) incl. cost ofconduit.
72Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with Ix4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEl/RR or equivalent ) incl. cost of conduit
73Supplying and fixing Of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/ SS Anchor/ A3B/Schneider or uivalent
74Supplying and fixing of suitable size GI box with modular plate and modular cover in 3 pin 5/6 A front on surface or in recess, including providing and fixing Of 2 no. modular socket outlet and 2 no. S/6A modular switch, connections, etc. as required.(Havells/ SSK/ Anchor/ ABB/Schneider or eq.)
75Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ABB/Schneider or eq.). 3 pin 5A - IOA socket.
76indicator.
77point wiring for 5A -IOA socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100v01t grade flexible stranded copper conductor wires in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop two points shall be connected on one circuit) (polycab/ Anchor/ Finolex/KEl/RR or equivalent) incl. cost of conduit
78Supply installation testing and commissioning Of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 1001m/W withpressure Die cast Aluminium Heat Sink and P.F.>0.95 ,CCT5700K, CRI OThe LED with Useful life of 50(m Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Havel's [Wipro make / sample to be approved before installation..
79Supply installation testingand commissioning of 12W+ LED Surface/recess, square orround Mounted light luminary fitting shape With minimum system lumen efficacy Of 100 1m/W Withpressure Die cast Aluminium Heat Sink and P.F.>0.95 .CCT 5700K. CRI 80.The LED with Useful life of 50000 Hrs at 170, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150Vt0270V -The Fixture should have In-built Surge Protection of2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government Of India. The job includes AMC (reckoned from date Of successful commissioning) Of lighting fixtures fora period of Two years ,which includes replacement of fixtures of Philips/ Havel's /Wipro make / sample to be approved before installation
80Providing, fixing, testing and commissioning of 9 Watt LED lamp (322 cap), BEE/ISI approved, 230 V, cool daylight (6500 K), minimum efficacy 1001m/W, complete with heavy-duty brass batten holder, including all fixing accessories, making electricalconnections, testing and commissioning as required at site.(Havells/Wipro/Philips/Crompton/Bajaj or equivalent) .Approved makes: Signify (Philips), Wipro Lighting, Havells, Crompton, Jaquar Lighting, Bajaj Electricals, LEDVANCE or equivalent approved make.
81Emergency LED Light Fitting: Supply, installation, testing and commissioning of premium quality self-contained LED emergency light fitting, 3—5 W LED, with integrated maintenance-free rechargeable battery and automatic mains-failure changeover,providing minimum 90 minutes emergency operation, complete with battery charging circuit, charge/healthy status indicator, suitable for 230 V, 50 Hz AC supply, and capable of achieving the required emergency illumination levels at the designated location, complete with mounting arrangement, fixing hardware, wiring terminals and all necessary accessories.
82Supply, Installation, Testing & Commissioning of 15 W surface/wall-mounted SMD LED bulkhead luminaire with pressure die-cast aluminium housing, powder-coated finish and polycarbonate opal diffuser, IP65, IKIO, minimum efficacy 1001m/W and 1500 1m output, CCT 5700 K, CRI 280, suitable for operation at 140—280 V AC. Complete with isolated constant-current LED driver (PF 20.95, THD SIO%, 2.5 kV surge protection), LM- 80 compliant LEDs with L70 life of 50,000 hours, conforming to IS 10322 and relevant BIS standards. LM-79 & LM-80 reports from NABL/UL accredited laboratory to be submitted. Approved makes: Signify (Philips), Wipro Lighting, Havells, Crompton, Jaquar Lighting, Bajaj Electricals, LEDVANCE or equivalent approved make.
83Supply, Installation, Testing and Commissioning Of 1200 mm sweep, ..ceiling fan With Brush Less Direct Current (BLDC) Motor, Class Of insulation: B, 3 nos. blades, suitable long down rod, 2 no.canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-14 2019), THD less than 10%, remote regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega Ohm, suitable for 230 V, 50 HZ, single phase AC Supply, earthing etc. complete as required. Atomberg/Orient/USHA /Havells /Crompton / OR OEMS/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge.
84Supply and fixing Of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd.
85Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incL cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Phili s/ Crom ton).
86Supply installation testing and comm. of flood light 50 W (warm White), Epoxy powder coated die-cast aluminium housing (LM24) With heat sink for thermal management, corrosion resistant, PG9gland for cable entry, provision for loop•in loop-out, class l, IP66, 1<07, high power LEDs, Built-In Potted IP67 electronic LED driver with APFC, lower THD, toughened glass and secondary lens,Open Circuit / Over Voltage / Surge Voltage Protection up to IOW with Built-ln SPD, as per IS 15885 Part-2/Sec 13, IEC60598-I. preferred make: Philips/ Havells/ Wipro/ Crompton. Includesangle iron stand grouted in cement concrete with hold fasteners, complete job.
87Supplying and fixing of modular blanking plates on existing modular plate and switch box excluding modular late as uired.
88Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, incl. cost of conduits (Havells/Polycab/ Finolex/ Anchor/KEI/RR or equivalent). 2 x 1.5 sq.mm + 1x 1.5 sq. mm earth wire
892 x 2.5 sq.mm + 1x 2.5 sq. mm earth wire
902 x 4 sq.mm + 1x 4 sq. mm earth wire
912 x 10 sq.mm + 1x 6 sq. mm earth wire
92Supply and fixing of 12 way Double door surface/ recess mounting, Horizontal type, 240 V, SPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer
93Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 5 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections
94Supply, installation, testing and commissioning of 32/40 A DP rating 240V, 10 KA \\"С\\" 5 curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.
95Supply, installation, testing and commissioning of 63 A DP rating 240V, 10 KA \\"C\\" curve 7 MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.
96Providing of chemical earthing as per IS standards by way of digging 8 feet pit then embedding 2.5 mtr. Long Gl earthing electrode, 60 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2\\" dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound
97Supply, laying, connecting and commissioning of 25 sq. mm 2 core PVC insulated and 9 PVC sheathed power cable of 1.1 KV grade Aluminum LT cable, incl. cost of required al. thimbles duly crimped
98Supply, installation, testing and commissioning of a 2 kVA, 24 V DC input, 230 V AC, 50 Hz output, pure sine-wave inverter/UPS with automatic mains changeover, suitable battery-charging system, overload, short-circuit, deep-discharge, overcharge and over-temperature protection, low-battery indication and automatic shutdown; complete with 2 Nos. 12 V, 200 Ah deep-cycle tall tubular batteries connected in series to form a 24 V30 battery bank, interconnecting cables, battery terminals, suitable DC fuse/isolator, AC input/output protection, earthing, mounting arrangements and all necessary accessories. The system shall provide a minimum of one hour of backup at the specified connected load, subject to the approved load schedule and manufacturer's discharge characteristics. The item shall include all incidental charges, complete in all respects. Make: Luminous/Exide/Microtek or equivalent approved make.
99Supply and fixing of fan deep made of heavy gauge sheet in RCC slabs
100Providing, supplying, installing, testing and commissioning of 2-pole 20A, 240V, motor-duty switch/isolator, suitable for controlling a 1 HP, 230V, single-phase water pump motor, complete with suitable HRC fuse/MCB protection, weatherproof enclosure, cable glands, terminals and all necessary accessories, including fixing and making all electrical connections, complete in all respects.
101MAIN PANEL - PANEL: Design, Fabrication, Supplying, Installation, Testing and Commissioning of panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel, floor mounted, vermin and dust proof, outdoor type with suitable size angle iron legs for grouting in the ground, lockable hinged doors, duly painted, with provision for fixing switch gears and Aluminium Bus Bar of various ratings (after de-rating factor) and other allied accessories as required. Scope also includes securely installing the panel into the ground with concrete encasing its legs. (As per approved design; size may vary as per site requirement.)
102INCOMING:100A DP MCB, 10 KA. Havells/ Legrand/Schneider/ABB/L&T - sample to be approved before installation.
1032 No. of Aluminium Bus Bar of 200 Amp
104Change over switch, 63 Amp, front operated
1052 No. of Aluminium Bus Bar of 100 Amp
106Digital meters and phase indicators - 1 set
10763 A DP RCCB (30 mA)
108SPD Type 2 (230 V, 10-20 KA)
109OUTGOING:63 amp DP, 10 KA MCB Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58154425
AUTHORITY Government Departments
TENDER VALUE 64.33 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Sub Centre At Ainoo Advt.Cost=₹ 64.33 Lacs, Amount Without Gst= ₹54.52 Lacs, Gst Amount= ₹9.81 Lacs
Basic Detail
Tender No ENIT No. 98 of 2026-27
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 22 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value 64.33 Lakhs
Tender Fee 1600
EMD 1.28 Lakhs
Exemption Not Available
Document List
8abae20b-5fc8-4545-b986-635d6909ae86.html
BOQ_1114717.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

8abae20b-5fc8-4545-b986-635d6909ae86.html

xls

BOQ_1114717.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender