Tender For Repair/Maint Of External Elect And Dispersal Light/ High Mast Light, Internal Eecterification, Haner Doors Including All Connecteing Items For Airfield Maintenance At Harni Airfield At Afs Vadodara.
Tender Value
20 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
18 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of External Elect And Dispersal Light/ High Mast Light, Internal Eecterification, Haner Doors Including All Connecteing Items For Airfield Maintenance At Harni Airfield At Afs Vadodara.
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour disconnecting & taking out faulty / burnt LT XLPE cable of size 240 Sqmm 3.5 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals, Supply & Fix new aluminium lugs made from 99.5% pure aluminium, of same size / pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed.Note:- Each Cable will be measured as one Job for payment. |
| 2 | Material and labour disconnecting & taking out faulty / burnt LT XLPE cable of size 185 Sqmm 3.5 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals, Supply & Fix new aluminium lugs made from 99.5% pure aluminium, of same size / pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed.Note:- Each Cable will be measured as one Job for payment. |
| 3 | Material and labour disconnecting & taking out faulty / burnt LT XLPE cable of size 120 Sqmm 3.5 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals, Supply & Fix new aluminium lugs made from 99.5% pure aluminium, of same size / pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed.Note:- Each Cable will be measured as one Job for payment. |
| 4 | Material and labour disconnecting & taking out faulty / burnt LT XLPE cable of size 95 Sqmm 3.5 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals, Supply & Fix new aluminium lugs made from 99.5% pure aluminium, of same size / pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed.Note:- Each Cable will be measured as one Job for payment. |
| 5 | Material and labour disconnecting & taking out faulty / burnt LT XLPE cable of size 70 Sqmm 3.5 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals, Supply & Fix new aluminium lugs made from 99.5% pure aluminium, of same size / pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed.Note:- Each Cable will be measured as one Job for payment. |
| 6 | Material and labour disconnecting & taking out faulty / burnt LT XLPE cable of size 50 Sqmm 3.5 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals, Supply & Fix new aluminium lugs made from 99.5% pure aluminium, of same size / pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed.Note:- Each Cable will be measured as one Job for payment. |
| 7 | Material and labour disconnecting & taking out faulty / burnt LT XLPE cable of size 35 Sqmm 3.5 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals, Supply & Fix new aluminium lugs made from 99.5% pure aluminium, of same size / pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed.Note:- Each Cable will be measured as one Job for payment. |
| 8 | Material and labour disconnecting & taking out faulty / burnt LT XLPE cable of size 25 Sqmm 3.5 / 4 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals, Supply & Fix new aluminium lugs made from 99.5% pure aluminium, of same size / pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed.Note:- Each Cable will be measured as one Job for payment. |
| 9 | M&L for straight through joint outdoor type for LT UG cable including jointing kits heat srinkable type complete suitable for aluminium conductor cables of size 25 to 50 Sqmm 3.5 core complete all as specified and directed. |
| 10 | M&L for straight through joint outdoor type for LT UG cable including jointing kits heat srinkable type complete suitable for aluminium conductor cables of size 70 to 120 Sqmm 3.5 core complete all as specified and directed. |
| 11 | Laboure only for taking out / down LT UG cable of size 3.5 Core 16 Sqmm to 240 Sqmm, of any descreption from trenches / pole etc for providing straight through joint, relaying the same cable after fixing fixing of joints complete all as specified and directed. Note:- Earth work and straight through joint shall be measured and paid separatly. . |
| 12 | Taking out existing unserviceable LT UG cable any size, from trenches etcNote :- Excavation, earth work, shall be measured and paid separately under appropriate items of this BOQ. |
| 13 | Material & Labour for laying, jointing and testing of LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 4 core, laid in trenches / laid under floor or fixed naked with walls / on poles / in ducts / in GI pipes etc. with and including MS Clamps, nuts, bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks / PCC cover and pipe shall be measured and paid separately under appropriate items of this BOQ. |
| 14 | Material & labour for laying, jointing and testing of LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 35 sqmm cross sectional area, 3.5 core, laid in trenches / laid under floor or fixed naked with walls / on poles / in ducts / in GI pipes etc. with and including MS Clamps, nuts, bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks / PCC cover and pipe shall be measured and paid separately under appropriate items of this BOQ. |
| 15 | S&F 50 mm outer dia HDPE (high-density polyethylene pressure pipe) pressure rating PN 10 with all fittings, laid in trenches or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge. |
| 16 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 metre deep in soft / loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer-in-Charge. |
| 17 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and as directed. |
| 18 | Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 19 | Supply and fix in replacement 1100 V grade heavy duty cable, PVC insulated copper conductor served with inner sheathing of PVC sheathed flat of stranded multistranded copper conductor size 2.5 sqmm 02 core complete all as specified and directed by Engr-in-Charge. |
| 20 | Supply and fix in replacement 1100 V grade heavy duty cable, PVC insulated copper conductor served with inner sheathing of PVC sheathed flat of stranded multistranded copper conductor size 4 sqmm 02 core complete all as specified and directed by Engr-in-Charge. |
| 21 | Supply and fix in replacement 1100 V grade heavy duty cable, PVC insulated copper conductor served with inner sheathing of PVC sheathed flat of stranded multistranded copper conductor size 6 sqmm 02 core complete all as specified and directed by Engr-in-Charge. |
| 22 | S&F in replacement copper conductor multistranded 4 Sqmm 4 core, 1100 volts grade, passing through and including PVC conduit pipe 25 mm dia with suitable cable lugs, clamps, nut bolts etc complete all as specified and directed. |
| 23 | Deployment of tools & machinery etc for comprehensive maintenance of 16 metre HIGH MAST LIGHT of any make any model fitted with any type of fixing arrangement by checking and servicing of all Electrical, mechnical and structurer components and make serviceable details as under:-(i) Remove any unwanted elements such as bird nests, remove debris from around and inside the light pole, remove critter guard and remove any debris and restore critter guard; Mow, weed remove and tree trim as required; remove any soil buildup from around the pole, (ii) Check handhole cover and bolts, tighten and / or replace as required.(iii) Ensure light cable are able to be latched fully into place and functioning properly (iv) Check gear box for seal leakage and rectify(vi) Check the transisitional yoke and cables for corrosion(vii) Check lift cables for frayed strands(viii) Repair or replace latch system reflectors as required(ix) Test lowering devices and fully operate to fully down position(x) Check pole cable insulation and connections for rust and cracks and replace if found unserviceable Note :- Spares Such as LED flood light, Cable, rewinding of electric motor etc under Comprehensive Maint should be measured and paid Seprately\\" |
| 24 | Deployment of manpower, tools & machinery etc for Dismentling of unserviceable existing High mast tower 16 Mtr height by opening of foundation nut for replacement of wire rope with replacement of D clamp for making functional of motorised system by using crane / hydra completeNote:- Wire rope and D clamp shall be measured and paid saperatly |
| 25 | Supply and fx in repair D clamp for high mast wire rop. |
| 26 | Supply and fix in repair 6 mm dia stainless steel wire of high mast light |
| 27 | Disconnecting the existing non functional motor from High Mast and Servicing / overhauling of 3 phase 1.5 HP high mast motor, by cleaning greasing and replacement of ball bearing complete. |
| 28 | Disconnecting the existing non functional Motor 1.5 HP 3 phase from existing high mast light and Rewinding the the same with super enameled heavy duty copper winding wire of same gauge and number of turns by using minilex fiber insulating sheet and sleeves, insulating by varnishing and drying, refixing / connecting and testing compete. |
| 29 | Supply and fix in replacement of unserviceable power contactor TPN 32 Amp with control coil for high Mast timer Panel. |
| 30 | Supply and fix in replacement of unserceable time switch astronomical type 5A with 2NC+ 2NC complete all as specified and as directed |
| 31 | Supply and fix in repacement MCB TPN 32 Amp 10 KA complete all as specified and as directed |
| 32 | Supply and fix 500 Watt LED flood fitting, having epoxy powder coated die cast aluminium housing, in grey finish with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout, PC lens/IP lens with narrow /wide beam distribution, toughened glass fixed to housing with screws, flood light should have IP 66 protection and impact resistance of IK 07, Lumen efficiency of LED not less than 110 lumen per watt system efficency, power factor >0.95, THD<10% at Full load CRI> 70%, flood light should have built in potted electronic LED driver with, lower THD, open circuit protection, over voltage protection, 10 KV surge voltage protection, and provided with company LOGO ingraved on housing of the flood light, including 3 core 1.5 Sqmm Copper conductar cable for connecting complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . |
| 33 | Supply and fix 300 Watt LED flood fitting, having epoxy powder coated die cast aluminium housing, in grey finish with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout, PC lens/IP lens with narrow /wide beam distribution, toughened glass fixed to housing with screws, flood light should have IP 66 protection and impact resistance of IK 07, Lumen efficiency of LED not less than 110 lumen per watt system efficency, power factor >0.95, THD<10% at Full load CRI> 70%, flood light should have built in potted electronic LED driver with, lower THD, open circuit protection, over voltage protection, 10 KV surge voltage protection, and provided with company LOGO ingraved on housing of the flood light, including 3 core 1.5 Sqmm Copper conductar cable for connecting complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . |
| 34 | Supply and fix 150 Watt LED flood fitting, having epoxy powder coated die cast aluminium housing, in grey finish with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout, PC lens/IP lens with narrow /wide beam distribution, toughened glass fixed to housing with screws, flood light should have IP 66 protection and impact resistance of IK 07, Lumen efficiency of LED not less than 110 lumen per watt system efficency, power factor >0.95, THD<10% at Full load CRI> 70%, flood light should have built in potted electronic LED driver with, lower THD, open circuit protection, over voltage protection, 10 KV surge voltage protection, and provided with company LOGO ingraved on housing of the flood light, including 3 core 1.5 Sqmm Copper conductar cable for connecting complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . |
| 35 | Supply and fix 100 Watt LED flood fitting, having epoxy powder coated die cast aluminium housing, in grey finish with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout, PC lens/IP lens with narrow /wide beam distribution, toughened glass fixed to housing with screws, flood light should have IP 66 protection and impact resistance of IK 07, Lumen efficiency of LED not less than 110 lumen per watt system efficency, power factor >0.95, THD<10% at Full load CRI> 70%, flood light should have built in potted electronic LED driver with, lower THD, open circuit protection, over voltage protection, 10 KV surge voltage protection, and provided with company LOGO ingraved on housing of the flood light, including 3 core 1.5 Sqmm Copper conductar cable for connecting complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . |
| 36 | Supply & Fix in replacement 150 Watt High-efficiency IP65 round LED high-bay luminaire with high system lumen efficacy not less than 110 lm / W, with aluminium die-cast housing, provides better uniformity and high illumination levels, Energy saving, environment friendly & robust open type vertical Highbay LED luminaire fixed in position & connecting complete.. |
| 37 | Taking down existing U/S bay light / flood light from hanger (The height of Light is approximate 12-15 Mtr) and refixed & connect the same after repairs by replacement of driver completeNote:- (i) Note:- Cost of driver shall be measured and paid seperatly as supply & fix. (ii) Cost for hiring of cranes / ladder is deemed to be included in the unit rates. |
| 38 | Taking down existing U/S Flood light from existing High mast light any capacity and refixed the same after repairs by replacement of driver / wiring complete.Note:- Cost of driver shall be measured and paid seperatly as supply & fix. |
| 39 | Taking down existing U/S dispersal Flood light from existing post any capacity and refixed the same after repairs by replacement of driver / surge protection / wiring completeNote:- Cost of driver shall be measured and paid seperatly as supply & fix. |
| 40 | Supply and fix in repair electronic driver for LED flood light 150 W, including connecting & testing complete. |
| 41 | Supply and fix in repair electronic driver for LED flood light 120 W, including connecting & testing complete. |
| 42 | Supply and fix in repair electronic driver for LED flood light 300 W, including connecting & testing complete. |
| 43 | Supply and fix 72 Watt LED street light fitting, with mandatory driver set, having pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embaded PC cover / IP lens, street light should have IP 66 protection, impact resistance of IK 07, Lumen efficiency of LED not less than 110 lumen per watt system efficency, power factor >0.95, THD<10% at Full load CRI> 70%, street light should have built in potted electronic LED driver with lower THD, open circuit protection, over voltage protection, 10 KV surge voltage protection, and provided with company LOGO ingraved on housing of the street light, including 3 core 1.5 Sqmm Copper conductar cable 1.5 Sqmm for connecting, complete including taking down of old UNSV fittings complete all as specified and directed by Engr -in-Charge.Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement . |
| 44 | Supply & fix in replacement GI brackets made of 50 mm nominal bore GI pipe medium grade of required length not less than 1.2 M long, mounting clamp made out of Mild steel FI 40 x 4 mm of required shape (two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide primer and fixed to pole / walls etc complete all as specified & directed by Engr-in-Charge. |
| 45 | S&F in repair Junction box of size 290 x 200 x 130 mm Polycarbonate body, Hinged Enclosure box for cable in / out of street light LT cable, out door type, testing and commissioning with locking arrangements fixed on poles, with 4 pole 100 Amp Connetor, including MCB SP - 01 Nos for connecting suitable size of XLPE UG cable all as specified and directed. |
| 46 | S&F in repalcement MCCB 3 Pole, 415 V, 160 Amps with breaking capacity 36 KA AC, 415 Volts three pole with thermal & adjustable magnetic setting, complete all as specified. |
| 47 | S&F in repalcement MCCB 3 Pole, 415 V, 200 Amps with breaking capacity 36 KA AC, 415 Volts three pole with thermal & adjustable magnetic setting, complete all as specified. |
| 48 | S&F in repalcement MCCB 3 Pole, 415 V, 250 Amps with breaking capacity 36 KA AC, 415 Volts three pole with thermal & adjustable magnetic setting, complete all as specified. |
| 49 | S&F in repalcement MCCB 3 Pole, 415 V, 315 Amps with breaking capacity 36 KA AC, 415 Volts three pole with thermal & adjustable magnetic setting, complete all as specified. |
| 50 | M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old cable complete all as specified and directed by Engr-in-Charge. |
| 51 | M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old cable complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F in replacement aviation obstraction light of Red colour LED type 8 Watt capacity suitable for 220 Volt 50Hz AC supply fixing on Blastpan / Highmast top with necessary arrangement including taking down of existing light all as specified and directed. |
| 53 | S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. |
| 54 | Supply and fix MCB’s single pole & neutral, 40 Amps, 250 volts with ‘B’ curve, fixed in sheet metal board complete including connecting. |
| 55 | Supply and fix MCB’s single pole 6-32 Amps, 250 volts with ‘B’ curve, fixed in sheet metal board complete including connecting. |
| 56 | S&F in replacement sheet metal enclosure single pole and neutral with 2 pin earth metal plug and socket with one single pole MCB 20 A, 230 volts etc complete as specified and directed |
| 57 | Supply & Fix in Replacment TPN vertical DB's provision for TPN MCCB Frame up to and including 125 Amp in 30 KA, as incommer 4 way all as specified and directed by Engr-in-Charge. |
| 58 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, including taking down old sub main wiring complete.Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 59 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, including taking down old sub main wiring complete.Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 60 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 10 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 10 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, including taking down old sub main wiring complete.Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 61 | Supply & Fix in repair Plastic Plug and connector in sheet steel Enclosure 63 Amp 5 Pole with SPN / TPN MCB 4 Way Cat Part Nos. DHDPBEN063 of Make: Havells or equvallent of make Legrand / L&T |
| 62 | Supply & Fix in repair Industrial interlocking socket with MCB TPN provision rating 16 Amp, 02P +E pole with SPN MCB 16 amp Cat Part Nos. DHDPBDP016 of Make: Havells or equvallent of make Legrand / L&T |
| 63 | Supply and applying of power plus gel in 5 KG packaging for reducing Soil resistivity reducing / Earth resistence The gel applying in existing earth pit with diluted in water as directed by engineer-in-charge. Make:- POWERTECH INDUSTRIES LTED PRAGATI / McML’s Earthing Solution (MES) / Ashlock |
| 64 | M&L for cutting of Road / PCC Hard standing / similar work, not exceeding 30 cm in width, not exceeding 45 cm in depth for passing of LT cable / Pipe etc, making good disturbed surface by returning filling with excavated material after laying of pipe / cable and top 20 cm portion filled with PCC (1:2:4) type B-1 using 20 mm graded aggregate, removing surplus excavated material to a distance not exceeding 50 metre complete all as specified and directed . |
| 65 | Supply, install testing & commisioning of feeder pillar box outdoor type made out of CRCA sheet not less than 3.15mm thick duly powder coated, CPRI approved 300 Amp rating Aluminium Busbar, box size not less than 1 metre x 1 metre x 0.40 metre including angle iron farme of 1 metre hight of leg suitable for arrengement of following :(a) Incommer :MCCB 100 16 KA 4 pole - 2 Nos (loop in /Loop Out)(b) Out going: MCB SPN 32 Amp - 3 Nos(c) out going TPN MCCB 63 A -4 Nos(d) power contractor with NO+NC 63 Amp TP 01 No.(e) Astronimical timer 2 NO+NC switch 01 No. |
| 66 | Deployment of manpower, tools & machinery & material etc for servicing & functionlity check of Electric operated hanger door (8 Nos Leaf) on monthaly basis, servicing would be on priority basis by all means lubrication of all required movable parts, checking of all electrical connection & control panel complate all as specified and as directed.Note:- (i) Servicing of all 8 Leaf in one month shall be measured as One job for payment. (ii) Repairing of Motor, gearbox etc shall be measured & paid seperatly. |
| 67 | M&L for Disconnecting the existing non functional motor from hanger door and Servicing / overhauling of 3 phase 12 HP motor including replacement of ball bearing, bush, oiling & greasing complete all as specified and as directed. |
| 68 | M&L Disconnecting the existing non functional Motor from existing hanger door and Rewinding the the same with super enameled heavy duty copper winding wire of same gauge and number of turns by using minilex fiber insulating sheet and sleeves, insulating by varnishing and drying, refixing / connecting and testing complete. |
| 69 | M&L for servicing of gear box with shaft taking down and refixing with gear box with gasket, chain drive at required places complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 70 | M&L for servicing of gear box with shaft taking down and refixing with gear box with gasket, chain drive at required places complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer