Bids Are invited for Csr Activity At General Hospital Mahesana
Tender Overview
Project Description
Bids Are invited for Flat Panel Digital C Arm X Ray Imaging System For Orthopedic And Surgical Procedures With Advanced Image Processing - The Technical Specifications Of All The Items Have Been Uploaded Along With The Bid Documents Bidders Are Requested To Quote Their Prices Strictly In Accordance With The Uploaded Technical Specifications The Quoted Prices Must Be For Medical Equipment And Instruments Of The Same Company And Manufacturer As Specified In The Bid Requirements Prices Quoted For Products Of Other Companies Or Manufacturers Shall Not Be Considered Valid For Evaluation , Battery Operated Modular Orthopedic Drill Reamer And Oscillating Saw System With Interchangeable Surgical Attachments - The Technical Specifications Of All The Items Have Been Uploaded Along With The Bid Documents Bidders Are Requested To Quote Their Prices Strictly In Accordance With The Uploaded Technical Specifications The Quoted Prices Must Be For Medical Equipment And Instruments Of The Same Company And Manufacturer As Specified In The Bid Requirements Prices Quoted For Products Of Other Companies Or Manufacturers Shall Not Be Considered Valid For Evaluation , Advanced Motorized Surgical Operating Microscope With Continuous Zoom Magnification Integrated Hd Camera And Biom Re Inverter - The Technical Specifications Of All The Items Have Been Uploaded Along With The Bid Documents Bidders Are Requested To Quote Their Prices Strictly In Accordance With The Uploaded Technical Specifications The Quoted Prices Must Be For Medical Equipment And Instruments Of The Same Company And Manufacturer As Specified In The Bid Requirements Prices Quoted For Products Of Other Companies Or Manufacturers Shall Not Be Considered Valid For Evaluation , Combined Anterior And Posterior Segment Ophthalmic Surgical System With Phacoemulsification And Posterior Vitrectomy Functions - The Technical Specifications Of All The Items Have Been Uploaded Along With The Bid Documents Bidders Are Requested To Quote Their Prices Strictly In Accordance With The Uploaded Technical Specifications The Quoted Prices Must Be For Medical Equipment And Instruments Of The Same Company And Manufacturer As Specified In The Bid Requirements Prices Quoted For Products Of Other Companies Or Manufacturers Shall Not Be Considered Valid For Evaluation , Nurse Calling From Individual Bed - Nursing Call System Enabled Hospital Nursing Call System With Wired Or Wireless Connectivitysystem Requirements Controller Based System With Bedside Call Units Nurse Station Display And Room Indicators Communication Through I2c Rs 485 Wi Fi Or Lan As Offered. Local Operation Without Internet Access Audible And Visual Alerts With Clear Bed And Room Identification. Calls Remain Active Until Attended And Cleared Support Call Priority Multiple Pending Calls And Expansion For Required Beds And Nurse Stations Configurable Room And Bed Mapping With Compatible Low Voltage Power Supply Components And Functions Controller Bedside Call Units Nurse Station Display Door Indicators Power Supply Cables And Accessories Multi Button Bedside Units And Emergency Toilet Pull Cord Units Where Required Normal Assistance And Emergency Calls With Call Reset After Attendance Different Indicators And Alert Sounds Where Supported Monitoring Software With Event Records And Reports Where Includedtechnical Requirements Architecture May Use I2c Mesh Rs 485 Wi Fi Or Lancontroller Capacity Shall Meet The Required Bed Count And Be Confirmed By The Manufacturerdatasheets Shall State Power Consumption Voltage Operating Temperature And Ip Ratingsbidder And Installation Submit Oem Name Model Number Catalogue Datasheets Compliance Sheet And System Diagram Include Supply Installation Testing Commissioning And Staff Training With All Accessories Submit Test Report Serial Number List User Manual And Warranty Certificateminimum Two Year Warranty From Acceptance Defective Parts Shall Be Repaired Or Replaced Without Extra Cost Provide Service Contacts And Spare Parts Support Testing And Acceptancedemonstrate Bedside And Emergency Calls Toilet Alerts Indicators Reset And Multiple Calls Final Acceptance Follows Successful Testing And Hospital Approval. Include Required Licences And Materials In The Price Use Brand Neutral Requirements And Evaluate Bids According To Tender Conditions
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Flat Panel Digital C Arm X Ray Imaging System for Orthopedic and Surgical Procedures with Advanced Image Processing | The technical specifications of all the items have been uploaded along with the bid documents Bidders are requested to quote their prices strictly in accordance with the uploaded technical specifications The quoted prices must be for medical equipment and instruments of the same company and manufacturer as specified in the bid requirements Prices quoted for products of other companies or manufacturers shall not be considered valid for evaluation |
| 2 | Battery Operated Modular Orthopedic Drill Reamer and Oscillating Saw System with Interchangeable Surgical Attachments | The technical specifications of all the items have been uploaded along with the bid documents Bidders are requested to quote their prices strictly in accordance with the uploaded technical specifications The quoted prices must be for medical equipment and instruments of the same company and manufacturer as specified in the bid requirements Prices quoted for products of other companies or manufacturers shall not be considered valid for evaluation |
| 3 | Advanced Motorized Surgical Operating Microscope with Continuous Zoom Magnification Integrated HD Camera and BIOM Re Inverter | The technical specifications of all the items have been uploaded along with the bid documents Bidders are requested to quote their prices strictly in accordance with the uploaded technical specifications The quoted prices must be for medical equipment and instruments of the same company and manufacturer as specified in the bid requirements Prices quoted for products of other companies or manufacturers shall not be considered valid for evaluation |
| 4 | Combined Anterior and Posterior Segment Ophthalmic Surgical System with Phacoemulsification and Posterior Vitrectomy Functions | The technical specifications of all the items have been uploaded along with the bid documents Bidders are requested to quote their prices strictly in accordance with the uploaded technical specifications The quoted prices must be for medical equipment and instruments of the same company and manufacturer as specified in the bid requirements Prices quoted for products of other companies or manufacturers shall not be considered valid for evaluation |
| 5 | Nurse Calling from Individual Bed | NURSING CALL SYSTEM Enabled hospital nursing call system with wired or wireless connectivitySYSTEM REQUIREMENTS Controller based system with bedside call units nurse station display and room indicators Communication through I2C RS 485 Wi Fi or LAN as offered. Local operation without internet access Audible and visual alerts with clear bed and room identification. Calls remain active until attended and cleared Support call priority multiple pending calls and expansion for required beds and nurse stations Configurable room and bed mapping with compatible low voltage power supply COMPONENTS AND FUNCTIONS Controller bedside call units nurse station display door indicators power supply cables and accessories Multi button bedside units and emergency toilet pull cord units where required Normal assistance and emergency calls with call reset after attendance Different indicators and alert sounds where supported Monitoring software with event records and reports where includedTECHNICAL REQUIREMENTS Architecture may use I2C mesh RS 485 Wi Fi or LANController capacity shall meet the required bed count and be confirmed by the manufacturerDatasheets shall state power consumption voltage operating temperature and IP ratingsBIDDER AND INSTALLATION Submit OEM name model number catalogue datasheets compliance sheet and system diagram Include supply installation testing commissioning and staff training with all accessories Submit test report serial number list user manual and warranty certificateMinimum two year warranty from acceptance Defective parts shall be repaired or replaced without extra cost Provide service contacts and spare parts support TESTING AND ACCEPTANCEDemonstrate bedside and emergency calls toilet alerts indicators reset and multiple calls Final acceptance follows successful testing and hospital approval. Include required licences and materials in the price Use brand neutral requirements and evaluate bids according to tender conditions |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender