Housing Urban and Rular Development Government Departments Closing in 0 days TDR #58150810

Tender For Detail Estimate For Construction Of Record Room At J.S.H.B. Headquarter Ranchi, Harmu Housing Colony Ranchi

Issued by Government Departments · Ranchi, Jharkhand
Tender Value
17.77 Lakhs
Estimated cost
Bid Submission
28 Oct 2026
0 days left
EMD
35541
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Detail Estimate For Construction Of Record Room At J.S.H.B. Headquarter Ranchi, Harmu Housing Colony Ranchi

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Oct-2026 Technical Bid Technical Bid 28-Oct-2026

BOQ

Name of Work:- DETAIL ESTIMATE FOR CONSTRUCTION OF Record ROOM AT J.S.H.B. HEADQUARTER RANCHI, HARMU HOUSING COLONY RANCHI
Sl. No. Item Description
1Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M including all lifts,levelling,ramming the foundation trenches,removing roots of trees,shurbs all complete as per approved design,building specification and direction of E/I .
2Extra for earthwork in hard soil as per building specification and direction of Engineer Incharge
3Earth filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification Ε/I (Mode direction measurement compacted volume)
4Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5Providing designation 75B one brick flat soiling joints filled with local sand including cost of watering taxes & royalty all complete as per building specification and direction of E/I.
6Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing 1:1.5:3 (1 Cement: 1% coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
7Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of AND centering, shuttering and finishing:1:2:4 (1 Cement: 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size)
8Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
9Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size).
10Centering and shuttering including structting, Propping etc. and removal of form forLintels, Beam, Plinth Bemas, Girders, bressumers and Cantilivers
11Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets,columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size )
12Centering and shuttering including structting, Propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Strusts
13Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement: 3 coarse sand), cost of required centering and shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III):3 graded stone aggregate 20 mm nominal size)
14Reinforced cement concrete work in arches, archribs, domes, Vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
15Centering and shuttering including structting, Propping etc. and removal of form for
16Providing designation 75A brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials raking out joints to 15 mm depth, curing, taxes & royalty all complete as per building specification and direction of E/I.
17Providing designation 125 mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15 mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/l.
18Providing 12 mm Thk. cement plaster(1:6) with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
19Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of EI
20Providing 12 mm Thk. cement plaster(1:4) with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
21Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/l.
22Providing applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth copmlete
23Finishing walls with textured exterior paint of required shade:New work (Two or more coats applied 3.28 Itr/10 sqm) over and including priming coat of exterior primer applied 2.20kg/10 sqm
24Providing and laying VITRIFIED FLOOR TILES in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08% and confirming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. (Approved brand - Kajaria/ Asian/ Somany)
25S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.)
26Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I
27Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
28Providing and fixing aluminium hanging floor door stoppers ISI marked anodized (anodic coating not less than grade Ac 10 as per I.S. 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twi rubber stopper.
29Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i. e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge (Glazing, paneling and dash fasteners to be paid for separately):For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
30Providing and fixing glazing in aluminium window, ventilator shutters etc. with EPDM / Neoprene gasket etc complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
31Providing Primer two coat of read lead paint of approved make over new STEEL SURFACE preparing the surface after cleaning, removing rust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
32Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/1.
33Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
34Providing and fixing fan hooks of 16mm dia M.S. bar & 1 meter long, bent torequired size and shape, placed in position and fixed in the R.C.C.slab/beam at the time ofcasting all complete as per building. specification and direction of E/I.
35providing Tor steel reinforcement of rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)8 mm Dia
3610 mm Dia
3712 mm Dia
38Bricks 8 km
39Local Sand (15 Kms)
40Cement + Steel ( L - 1 Km )
41Stone Chips=20 km
42Point wiring in PVC conduit, with piano type switch :- wiring for light point/fan point/exhaust fan point/call bell point 1.5 sq.mm FR PVC insulated copper conductor single core cable in existing surface/recessed Steel/PVC conduit including dismantling as required
43Twin control Point in PVC conduit with piano type switch :- wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in existing surface/recessed steel/PVC conduit including dismantling as required
44Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required2x1.5 sq mm+1x1.5 sq mm earth wire
452x2.5 sq mm+1x2.5 sq mm earth wire
462x4.0 sq mm+1x4.0 sq mm earth wire
47S/F PVC conduit: supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.
48S/F modular type switch /socket :-Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required5/6 amps, one way switch
495/6 amps, 3 pin socket outlet
50S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
51S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.1 or 2 module (78mm x 78mm x 45mm)
52S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required.
53S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
54S/F Batten holder:-Supplying and fixing batten/angle holder including connection etc, as required.
55ITC fluorescent fitting directly on surface:-Instaliation, testing and commissioning of prewired, fluorescent fitting of all types, complete with all accessosries and tube etc. directly on ceiling/wall including connection with 1.5 sq mm.FR PVC insulated, copper conductor.
56ITC ceiling fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length(uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required
57S/F VERTICAL TYPE T.P.MCB DB:-Supplying and fixing following way three pole and nutral, sheet, MCB distribution board,415 volt,in recess, complete with tinned copper busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required. (But without MCB/RCCB/ISOLATOR)Note:- Vertical type MCB TPDB is normally used where three phase outlets are required.4 way (4+24), Double door, Vertical type
58S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral, sheet, MCB distribution board,415 volt, in recess, complete with tinned copper busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required. (But without MCB/RCCB/ISOLATOR)4 way (4+12), Double door, Horizontal type
599/10 Watt LED Bulb
60S.I.T.C. 1200 mm ( 48'' ) ceiling fan
61Add 18% GST (+)
62Add 1% Labour Cess (+) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58150810
AUTHORITY Government Departments
TENDER VALUE 17.77 Lakhs
LAST DATE 28-10-2026
Authority
Authority Name Jharkhand State Housing Board
Work Description Tender for Detail Estimate For Construction Of Record Room At J.S.H.B. Headquarter Ranchi, Harmu Housing Colony Ranchi
Basic Detail
Tender No JSHB/OT/RNC/28/2026-27
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 22 Oct 2026
Submission Date 28 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 17.77 Lakhs
Tender Fee 5900
EMD 35541
Exemption Not Available
Document List
43af6a1e-5870-4cc8-9efb-51f2f5bd8316.html
BOQ_162364.xls
RFP28OT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
html

43af6a1e-5870-4cc8-9efb-51f2f5bd8316.html

xls

BOQ_162364.xls

pdf

RFP28OT.pdf

pdf

Tendernotice_1.pdf

Disclaimer