Tender For Shifting Of 33Kv Double Feeder Transmission Tower Line (Washery-1 And Washery-2 Feeder) And Dismantling And Erection Of Lighting Line And 6.6Kv Power Line At Kkc Main Siding For Extension Of Siding Platform Under Madhuban D.G. Sub-Station
Tender Overview
Project Description
Tender for Shifting Of 33Kv Double Feeder Transmission Tower Line (Washery-1 And Washery-2 Feeder) And Dismantling And Erection Of Lighting Line And 6.6Kv Power Line At Kkc Main Siding For Extension Of Siding Platform Under Madhuban D.G. Sub-Station Of Block-Ii Area Bccl.
BOQ
| Sl. No. | Item Description |
| 1 | Shifting of 33KV Transmission Tower |
| 2 | Supply of Galvanised stub & Cleat including pack washers |
| 3 | Supply of Galvanised tower members/structures including pack washers |
| 4 | Supply of painted fabricated Stub Setting Template. |
| 5 | Supply of AAAC Dog (19/2.89 mm) Conductor |
| 6 | Supply of Earth Wire (galvanised Steel 7/3.15mm) |
| 7 | Supply of 120KN Disc Insulator |
| 8 | Supply of single tension hardware set for AAAC Dog (19/2.89mm) conductor suitable for tower. |
| 9 | Supply of Single Suspension hardware set for AAAC Dog (19/2.89mm) conductor suitable for tower. |
| 10 | Supply of Tension hardware set for earth wire compression type with complete tension clamp and flexible copper bond for galvanised steel wire (7/3.15mm) suitable for tower |
| 11 | Supply of tower earthing set |
| 12 | Supply of vibration dampers for AAAC Dog (19/2.89mm) conductor |
| 13 | Supply of PG clamp for AAAC Dog (19/2.89mm) conductor |
| 14 | Supply of damger Plate |
| 15 | Supply of Anticlimbing Device |
| 16 | Supply of Barbed wire |
| 17 | Clearing grass and removal of the rubbish/gravel upto distance of 50M outside the periphery of the area cleared |
| 18 | Check survey as per approved survey chart including Peg marking and prepration of as built route profile |
| 19 | Detail survey including preliminary survey(plotting on route in toppo sheet), plotting of towers in the route profile, prepration and submission of profile drawing, line chart, tower schedule. |
| 20 | Providing & Laying in position Reinforced concrete work in pyramid/chimney of tower foundation & plinth, with coarse sand & 20mm & down stone aggregates of approved quality, well graded, washed and screened including cost of supply of all materials and cost of transport of all materials to site, mixing, laying, vibrating, cutting etc. complete & also including erection, supporting striking out, cleaning etc. of steel muff-boxes. but excluding the cost of reinforcement and muff-boxes/formwork as per brgs. sepecifications. Concrete mis 1:1:2 |
| 21 | Fitting of templete (SST) & setting of stub, 4stubs/tower or fitting of stubs through proper setting 33KV D/C Btype tower |
| 22 | Transporting, Handling, Assembling & Erecting of tower members (HT & M.S.) / structures / gantries / body extensions of all types of tower etc. from stores &/or site with contractor’s own tools & tackle, crane, labour etc., including checking, punching & tack welding of bolts & nuts and/or connections up to bottom cross arm including aluminium paint. Also including fitting & fixing of Number Plates, Danger Plates, Phase Plates, Circuit Plates, Bird Guards, Anti Climbing Devices etc., complete as per drawing, specifications & directions of the Engineer-in-Charge |
| 23 | Grounding of Tower with GI pipe, GI flat etc as per drawing, including excavation, backfilling, levelling and cost of storing, handling & transportion of materials to site complete as per drawing, specification and direction. |
| 24 | Laying, stringing of 6 (six) nos. conductors AAAC Dog (19/2.89 mm) in double circuit including hoisting of the insulator and fixing on the Rail Pole structure/Tower, erection of the hardware sets, jointing of conductors, running out and pulling up of conductors and tensioning and clipping-in with the clamps/pin insulator, fixing of vibration dampers and/or preformed armour rods, erection of jumpers at section/angle location and hoisting and fixing of suspension insulator sets or pin insulator, stringing of jumper connection etc., complete in all respects as per specification and direction of Engineer-in-Charge including storing, handling and transportation of all materials to site including felling down of trees as per regulation. For stringing between tower to tower |
| 25 | Laying, stringing and sagging of Earth wire (7/3.15 mm galvanized steel wire) including laying, stringing, tensioning, clamping, jointing etc. including transportation of all materials to site, storage & handling as per route KM of the line and fixing of hardware, compression jointing complete in all respect as per direction of Engineer-in-Charge. For stringing between tower to tower |
| 26 | Dismantling of all types of transmission line Rail Poles/Steel Structures (already erected) by cutting the members with gas cutter/arc cutter and stacking at designated places including transportation of all dismantled materials to specified stores. |
| 27 | Dismantling of ACSR Dog Conductor |
| 28 | Dismantling of Disc Insulator |
| 29 | Dismantling and Erection of 6.6KV Power Line. |
| 30 | Dismatline of LT pipe pole |
| 31 | Dismantling of ACSR Rabbit Conductor |
| 32 | Dismantling of Light fittings |
| 33 | Dismantling of Conductor Jumper. |
| 34 | Dismantling of Iron Material. |
| 35 | Dismantling of LT pin/shackle insulator. |
| 36 | Erection of LT pipe pole |
| 37 | Supply of 4 wire 1.1KV (3phase and Neutral) Air Bunch Cable |
| 38 | Erection of 4 wire 1.1KV Air Bunch Cable |
| 39 | Supply and erection of iron material |
| 40 | supply and fitting of Dristribution Box for light connection at pole |
| 41 | Installation of Light fittings. |
| 42 | Erection of Cable Lead |
| 43 | Dismantling and Erection of 6.6KV Power Line. |
| 44 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6(1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. |
| 45 | Erection of Iron Materials. |
| 46 | Supply and erection of iron materials Nut, bolt Bracket Clamp etc. |
| 47 | Supplying and erection of11KV grade bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener), 7/ 3.15mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and also with 0.6 m long brace of size 50mm X 50 mm X 6 mm angle iron with 50 mm dia pulley fixed at one end of the brace as required. |
| 48 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
| 49 | Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanised strainclamps, bolts, nuts, washers etc. as required. |
| 50 | Supply and erection of earth wire. |
| 51 | Jumpering of O/H line conductor. |
| 52 | Drawing of ACSR Dog Conductor |
| 53 | Dismantling and transportation of HT pipe pole /Rail Pole |
| 54 | Dismantlinf of Iron Materials. |
| 55 | Disconnection of O/H line Jumper. |
| 56 | Dismantling of Pin Insulator |
| 57 | Dismantling of Disc Insulator |
| 58 | Dismatling of Earth Wire. |
| 59 | Dismantling of ACSR Dog Conductor. |
| 60 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender