Public Administrative Department Local Bodies Closing in 7 days TDR #58149292

Tender For Providing Electrical Wiring And Other Electrical Fittings & Fixtures At Officers Room Of Civil Department Under Safdarjung Flyover And Improvement Of Sanitary Store At Tuglak Crescent And At Kitchens, Bathrooms And Toilets In All Type-Iv F

Issued by Local Bodies · Delhi, Delhi
Tender Value
37.36 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
7 days left
EMD
74732
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Electrical Wiring And Other Electrical Fittings & Fixtures At Officers Room Of Civil Department Under Safdarjung Flyover And Improvement Of Sanitary Store At Tuglak Crescent And At Kitchens, Bathrooms And Toilets In All Type-Iv Flats At Apj Abdul Kalam Lane Flats (18 Nos.) And Replacement Of Old Tube Light Fittings With Led Battens & Existing Mcbs Dbs In Various Schools Under Jor Bagh Wiring Enquiry, Bm-Ii(E) Division, New Delhi.

BOQ

Name of Work:- Providing electrical wiring and other electrical fittings & fixtures at officers room of Civil department under Safdarjung Flyover and improvement of Sanitary Store at Tuglak Crescent and at Kitchens, Bathrooms and Toilets in all Type-IV flats at APJ Abdul Kalam Lane Flats (18 nos.) and replacement of old tube light fittings with LED Battens & existing MCBs DBs in various schools under Jor Bagh wiring enquiry, BM-II(E) division, New Delhi.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/recessed steel conduit, with modular switch, modularplate, suitable GI box and earthing the point with 1.5sq.mm FRLS/HFFR PVC insulated copper conductorsingle core cable etc. asrequired.Group C.  For Officers room & Sanitary store
2Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/recessed steel conduit, with piano type switch,phenolic laminated sheet, suitable size MS box andearthing the point with 1.5 sq.mm FRLS/HFFR PVCinsulated copper conductor single core cable etc. asrequired. Group B. For Type-IV flats
3Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. For Officers room & Sanitary store - 350 mtr For Type-IV flats - 450 mtr
4Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. For Officers room & Sanitary store2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
52 X 6 sq. mm + 1 X 6 sq. mm earth wire
62 X 10 sq. mm + 1 X 6 sq. mm earth wire
7Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. For Officers room & Sanitary store
8Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door For various schools -38 nos
912 way , Double door For Officers room & Sanitary store- 3 Nos. For various schools -58 nos.
10Supplying and fixing following way, horizontal typethree pole and neutral, sheet steel, MCB distributionboard, 415 V, on surface/ recess, complete withtinned copper bus bar, neutral bus bar, earth bar, dinbar, interconnections, powder painted includingearthing etc. as required. (But withoutMCB/RCCB/Isolator). For various schools4 way (4 + 12), Double door
118 way (4 + 24), Double door
12Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required.63amps For Officers room & Sanitary store- 3 Nos. For various schools -99 nos
13Supplying and fixing following rating, four pole, 415V, isolator in the existing MCB DB completewithconnections, testing and commissioning etc. as required. For various schools100 amps
14Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. Single pole For Officers room & Sanitary store- 30 Nos. For various schools -1312 nos.
15Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket oulet and complete with connections, testing and commissioning etc. as required. For Officers room & Sanitary store -5 Nos. For various schools – 27 Nos.
16Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. For Officers room & Sanitary store –40 Nos. For Type-IV flats –180 Nos.
17Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connections etc. as required. For Officers room & Sanitary store –40 Nos. For Type-IV flats –54 Nos.
18Brush Less Direct Current (BLDC) Fan withoutRemote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value 63 DELHI SCHEDULE OF RATES (E&M)-2025 (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) For Officers room & Sanitary store
19LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver(Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained tilllife ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18-22watt For Officers room & Sanitary store –52 Nos. For Type-IV flats –54 Nos. For various schools -1600 nos.
20SITC of exhaust fan double ball bearing heavy duty, 12\\" (300mm sweep)complete with motor, 3/4 blades sets down double ball bearing andmotor should be copper winding performs well at low voltage, RPM 1400, 220/240 V, 50 HZ, Grey colors. warranty 02 years from the date ofsupply  For Officers room & Sanitary store
21LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 degree C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, 54 DELHI SCHEDULE OF RATES (E&M)-2025 EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not morethan the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and alltesting required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 50 watt For Officers room & Sanitary store
22Supply of LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) For Officers room & Sanitary store
23Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connectionswith 1.5 sq. mm FRLS/HFFR PVC insulated, copperconductor, single core cable and earthing etc. asrequired. For Officers room & Sanitary store
24Deduct - Less credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58149292
AUTHORITY Local Bodies
TENDER VALUE 37.36 Lakhs
LAST DATE 30-10-2026
Authority
Authority Name New Delhi Municipal Council
Work Description Tender for Providing Electrical Wiring And Other Electrical Fittings & Fixtures At Officers Room Of Civil Department Under Safdarjung Flyover And Improvement Of Sanitary Store At Tuglak Crescent And At Kitchens, Bathrooms And Toilets In All Type-Iv Flats At Apj Abdul Kalam Lane Flats (18 Nos.) And Replacement Of Old Tube Light Fittings With Led Battens & Existing Mcbs Dbs In Various Schools Under Jor Bagh Wiring Enquiry, Bm-Ii(E) Division, New Delhi.
Basic Detail
Tender No 59/EE (BM-II) E/26-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 21 Oct 2026
Submission Date 30 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 37.36 Lakhs
Tender Fee Ref. Documents
EMD 74732
Exemption Not Available
Document List
b0b39580-c75b-4464-92e6-8c893c167229.html
BOQ_400794.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

b0b39580-c75b-4464-92e6-8c893c167229.html

xls

BOQ_400794.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender