Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement To Sub Main, Dbs, Mccbs La, Earthing Strip, Junction Boxes, Feeder Pillar Boxes And Certain E/M Works At 39 Wing Af Stn Udh Ur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 27-Oct-2026 CERTAIN CHANGES IN TENDER DCOUCS BOQ 09-Nov-2026

BOQ

Name of Work:- REPAIR/REPLACEMENT TO SUB MAIN, DBS, MCCBS LA, EARTHING STRIP, JUNCTION BOXES, FEEDER PILLAR BOXES AND CERTAIN E/M WORKS AT 39 WING AF STN UDH UR
Sl. No. Item Description
1M&L in repair Explosion proof new point wiring for one light/bell/buzzer with 1.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel in surface conduit ISI marked with all flame proof conduit fittings and accessories fixed is walls/ceiling with proper fixing arrangment including one number continuous run of 1.5 Sqmm PVC insulated fire retardent multistandard copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable with colour coding according to norms for Class Zone IE Ex II C for one light point controlled by one way switch, all as specified.
2M&L in repair Explosion proof point wiring for one light/bell/buzzer with 1.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel in existing conduit ISI marked with all flame proof conduit fittings and accessories fixed is walls/ceiling with proper fixing arrangment including one number continuous run of 1.5 Sqmm PVC insulated fire retardent multistandard copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable with colour coding according to norms for Class Zone Ex II C for one light point controlled by one way switch, all as specified.
3M&L in repair Explosion proof new point wiring for one socket point with 2.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including new ERW rigid steel in surface conduit ISI marked with all flame proof conduit fittings and accessories fixed is walls/ceiling with proper fixing arrangment including one number continuous run of 2.5 Sqmm PVC insulated fire retardent multistandard copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable with colour coding according to norms for Class Zone Ex II C for one socket point controlled by one way switch, all as specified.
4Explosion proof rotary switch single pole on and off with cable termination box of 10 Amps rating 230 Volts Class E EX II C suitable for class I Zone I, all as specified.
5Supply and repair of Explosion proof rotary switch single pole on and off with cable termination box of 16 Amps rating 250 Volts Class E EX II C suitable for class I Zone I, all as specified..
6Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amps, 250 Volts, 2P+earth all as specified.
7Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amps, 250 Volts, 2P+earth all as specified.
8Supply and Fixing LED light fitting 2x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & III B, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc including taking down old unsv tubelight fitting complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
9S & F 250 watt Flameproof / Explosion proof LED flood light / well glass fixture, suitable for Zone 1, zone 2, Gas group II A, IIB (certified by CIMFR / ERTL), pressure die cast housing ( LM6 of equivalent), with toughened clear glass with neoprene / silicon gasket, robust MS / wire guard, IP 66, lumen> 110 lumen per watt, with surge protection of minimum 4 KV SPD, MS /GI cradle as mounting bracket, SS fastener, washers and making suitable connections including taking down old unsv non flameproof light fitting / flame proof light fitting / bulkhead all as specified and directed by Engr-in-charge.
10S & F 120 watt Flameproof / Explosion proof LED flood light / well glass fixture, suitable for Zone 1, zone 2, Gas group II A, IIB (certified by CIMFR / ERTL), pressure die cast housing ( LM6 of equivalent), with toughened clear glass with neoprene / silicon gasket, robust MS / wire guard, IP 66, lumen> 110 lumen per watt, with surge protection of minimum 4 KV SPD, MS /GI cradle as mounting bracket, SS fastener, washers and making suitable connections including taking down old unsv non flameproof light fitting / flame proof light fitting / bulkhead all as specified and directed by Engr-in-charge.
11S & F 150 watt Flameproof / Explosion proof LED flood light / well glass fixture, suitable for Zone 1, zone 2, Gas group II A, IIB (certified by CIMFR / ERTL), pressure die cast housing ( LM6 of equivalent), with toughened clear glass with neoprene / silicon gasket, robust MS / wire guard, IP 66, lumen> 110 lumen per watt, with surge protection of minimum 4 KV SPD, MS /GI cradle as mounting bracket, SS fastener, washers and making suitable connections including taking down old unsv non flameproof light fitting / flame proof light fitting / bulkhead all as specified and directed by Engr-in-charge.
12M&L in replacement of Flame Proof Weather Proof tube LED type 20 Watt fitting ,230Volt 50HZ Including minor repair as such Replacement of connector,Holder (Bipin),starter etc all as specified and as directed.
13Supply and fixing of Flame proof JB/104 FLP Junction box 3/4 way(to be used as incpection Elbow) complete as per existing size complete all as specified and as directed.
14Supply and fixing of Flame proof CG/209- FLP/WP3/4\\" ET 17.50mm OD DC bras Nickel plated Cable Gland complete as per existing size complete all as specified and as directed.
15Supply and fixing of Flame proof ACC/2019 FLP/WP Bends for conduit with3/4\\" ET entries complete all as specified and as directed.
16MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including accessories therein & disposing from site complete all as specified and as directed.
17MCB SPN 40 to 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including accessories therein & disposing from site complete all as specified and as directed.
18Supply, fabrication, assembly, testing of Flameproof/Weatherproof (FLP/WP) Distribution Board, suitable for 415 V, 3-phase, 4-wire, 50 Hz AC supply, complete with suitably rated enclosure, incoming and outgoing miniature circuit breakers (MCBs), copper busbars, internal power wiring, terminals, mounting arrangements, earthing terminals, identification labels, Flameproof, Ex d certified enclosure, Electrolytic copper busbar adequately rated as per incomer, Certified Ex d cable glands, suitable for cable type and size and all necessary internal accessories including taking down old unsv non flameproof (SPN / TPN) / Flame proof DB conforming to the approved technical specifications and applicable standards. The distribution board shall comprise the following: 1. Incoming MCB 4-pole, 63 A, 10 kA breaking capacity - 01 Nos. 2. Outgoing MCB 4-pole, 32 A, 10 kA breaking capacity - 03 Nos 3. Outgoing MCB 1-pole, 6 A, 10 kA breaking capacity - 06 Nos. 4. Busbars Copper busbars of adequate current-carrying capacity, with suitable supports and insulation - 01 Set. 5. Internal wiring Suitable-size insulated copper conductors, complete with ferrules and termination accessories - 01 set. 6. Enclosure FLP/WP type, approximate dimensions 7. Earthing arrangement Earth terminals and internal bonding - 01 set. 8. Accessories Terminal blocks, labels, fixing hardware and internal interconnections - 01 set. Make: Shyam / Sudhir for the distribution board; reputed approved make for MCBs, subject to technical approval.
19M&L of MCB TPN 40 to 100 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including accessories therein & disposing from site complete all as specified and as directed.
20Supply and fix in repairs of MCCB 4P 100 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
21Supply laying, connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 70 sqmm 3.5 core laind in trenches or passing through pips/ ducts complete all as specified and directed by Engineer in charge
22S&F in repair to MS Nipple BSP 175 MM/3/4\\" as per existing firring /DBs complete all as specified and as directed.
23Supply and fix in repair to alluminium alloy/ cast iron Neoprene Gasket degree of protetion IP65 complete all as specified and as directed .
24Supply and repair of MS Nipple conduit 175 MM/3/4\\" as per existing firring /DBs complete all as specified and as directed.
25Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, , complete all as specified and directed by Engineer-in-Charge
26Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge
27Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point ,complete all as specified and directed by Engineer-in-Charge
28Dry sand cushioning to under ground cable all as per clause 19.75 of SSR Part - I laid before and after laying of cable, complete all as specified and directed by engr-in-charge.
29Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire drawn through steel conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire shall be considered as 1 running metre for payment purpose.
30Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5 sqmm (nominal area) 1100 volts grade cable as earth wire drawn through steel conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 2.5 sqmm main cable and one RM of 2.5 sqmm cable as earth wire shall be considered as 1 running metre for payment purpose.
31Supply and fixing HDPE Pipe 90mm dia used to cabe protection all as specified and directed by Engr-in-Charge.
32Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable complete all as specified and directed
33Cutting of road (in hard/ dense soil ) for laying pipe line or repair to pipes of any size upto 0.5mtr. Depth and getting out incluiding forming bottom surface to required level and making good the road as per existing bitumens , concrete all as specified and directed.
34Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
35Supply and fixing of Earth continuity conductor or main 4 mm Galvanised iron wire fixed to wall on batten or recess or chases including or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. Complete all as specified and as directed Please Enable Macros to View BoQ information
36Supply and fixing of Earth continuity conductor or main 4 mm Galvanised iron wire fixed to wall on batten or recess or chases including or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. Complete all as specified and as directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58148731
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement To Sub Main, Dbs, Mccbs La, Earthing Strip, Junction Boxes, Feeder Pillar Boxes And Certain E/M Works At 39 Wing Af Stn Udh Ur
Basic Detail
Tender No GEAFU-83/2026-27
Bidding Type Tender
Location
City Udhampur
State Jammu and Kashmir
Key Dates
Publish Date 27 Oct 2026
Submission Date 09 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Not Available
Document List
BOQ_891590.xls
fc618aa3-d579-4adb-85c3-aadde9bb8b70.html
TEDNER83.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_891590.xls

html

fc618aa3-d579-4adb-85c3-aadde9bb8b70.html

pdf

TEDNER83.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender