| Sl. No. | Item Description |
| 1 | Taking out Copper / Aluminium Point wiring of any capacity and make alongwith switch, socket, regulator, ceiling rose, metal flush box and hylem sheet etc from existing location including PVC fixed on roof/wall complete all as specified and directed. |
| 2 | M&L in repair modular point wiring using approved colour coding for one light/bell controlled by one switch or one fan point controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral including new PVC casing caping / new concealed conduit for mounting of modular switch, socket and regulator on modular box fixed on surface / concealed in wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note : box and cover plate shall be measured and paid separately. [ Make of cable - Finolex / Havell's / Polycab ] |
| 3 | All as per serial item No 2.00 here-in-before but for 2 way point wiring complete all as specified and directed. |
| 4 | All as per serial item No 2.00 here-in-before but for 5 amp modular socket on independent board complete all as specified and directed. |
| 5 | All as per serial item No 2.00 here-in-before but for 5 amp modular socket on same board complete all as specified and directed. |
| 6 | M&L in repair modular point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral including existing concealed conduit for mounting of modular switch, socket and regulator on modular box fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. NOte : box and cover plate shall be measured and paid separately [ Make of cable - Finolex / Havell's / Polycab ] |
| 7 | All as per serial item No 6.00 here-in-before but for 2 way point wiring complete all as specified and directed. |
| 8 | All as per serial item No 6.00 here-in-before but for 5 amp modular socket on independent board complete all as specified and directed |
| 9 | All as per serial item No 6.00 here-in-before but for 5 amp modular socket on same board complete all as specified and directed |
| 10 | Supply and fix modular switch , 1 way 6 Amp 1 module singe pole one way complete all as specified and directed |
| 11 | Supply and fix modular switch , 2 way 6/10 Amp 1 module singe pole one way complete all as specified and directed |
| 12 | Supply and fix modular socket outlet 3/5 pin, 6 amp, 2 module complete all as specified and directed. |
| 13 | M&L in repair modular metal flush box, 4 module complete all specified and directed by Engr - in Charge |
| 14 | M&L in repair modular metal flush box, 3 module complete all specified and directed by Engr - in Charge |
| 15 | M&L in repair modular metal flush box, 1/2 module complete all specified and directed by Engr - in Charge |
| 16 | M&L in repair modular 4 module white cover outer plate/frame suitable for GI modular flush box complete all specified and directed by Engr - in Charge |
| 17 | M&L in repair modular 3 module white cover outer plate/frame suitable for GI modular flush box complete all specified and directed by Engr - in Charge |
| 18 | M&L in repair modular 1 / 2 module white cover outer plate/frame suitable for GI modular flush box complete all specified and directed by Engr - in Charge |
| 19 | M&L in repair modular Blanking plate 1 module complete all specified and directed by Engr - in Charge |
| 20 | Supply and fix in repair modular Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed. |
| 21 | Supply and fix in repairs LED Tube lights fitting Four feet 20 Watt LED, 220V AC, min 100 lumen per watt, 3000/6500 K decorative LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. Make: Philips cat no. Signify twin glow or Havells / crompton / Bajaj / Wipro |
| 22 | Supply and fix in replacement of 40 watt LED lights fitting four feet LED 3000/6500 K, 220V AC, 50 Hz, complete with Led driver, decorative surface mounted LED lighting fixture with polycarbonate environmental friendly, holder connecting up with flexible copper conductor cable of suitable size from ceiling rose complete inc taking down all as specified and directed by Engr-in-Charge. Make Havells / crompton/ Philips/Ledure/Murphy |
| 23 | M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.0 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.0 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC concealed conduit, heavy duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 6.0 sqmm cable and one RM of 6.0 sqmm cable as earth wire shall be considered as one RM for payment purpose. |
| 24 | M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 1.5 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 1.5 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC concealed conduit, heavy duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 1.5 sqmm cable and one RM of 1.5 sqmm cable as earth wire shall be considered as one RM for payment purpose. |
| 25 | M&L in repair rigid non-metallic PVC conduit / PVC casing caping of dia not less than 20 mm including of boxes (junction/terminal) all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, fixing on roof/wall including fixing arragement like saddled and other material complete all as specified and directed. |
| 26 | M&L in repair for point wiring for one Light / Fan / bell etc controlled by one 5 Amp switch using approved colour coding as per IS complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through existing PVC Casing caping / surface conduit with pressed steel concealed Sunken boxes of reqd size and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.[ Make of cable - Finolex / Havell's / Polycab ] |
| 27 | All as per serial item No 26 here-in-before but for two way switch complete all as specified and directed. |
| 28 | All as per serial item No. 26 here-in-before but for size 1.5 Sqmm on Independent board complete all as specified and directed |
| 29 | All as per serial item No. 26 here-in-before but for size 1.5 Sqmm on same board complete all as specified and directed |
| 30 | M&L in repair for point wiring for one 15 Amp socket controlled by one15 Amp switch using approved colour coding as per IS complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked with PVC insulated, unsheathed FRLS multi stranded copper conductor 4 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through new PVC Casing caping / new surface conduit with pressed steel concealed Sunken boxes of reqd size and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 4.0 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Polycab ] |
| 31 | All as per serial item No 30 here-in-before but for two way switch complete all as specified and directed. |
| 32 | All as per serial item No. 30 here-in-before but for size 1.5 Sqmm on Independent board complete all as specified and directed |
| 33 | All as per serial item No. 30 here-in-before but for size 1.5 Sqmm on same board complete all as specified and directed |
| 34 | M&L in repair for point wiring for one Light / Fan / bell etc controlled by one 5 Amp switch using approved colour coding as per IS complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through new concealed conduit with pressed steel concealed Sunken boxes of reqd size and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.[ Make of cable - Finolex / Havell's / Polycab ] |
| 35 | All as per serial item No 34 here-in-before but for two way switch complete all as specified and directed. |
| 36 | All as per serial item No. 34 here-in-before but for size 1.5 Sqmm on Independent board complete all as specified and directed. |
| 37 | All as per serial item No. 34 here-in-before but for size 1.5 Sqmm on same board complete all as specified and directed. |
| 38 | Supply and fix Switch Piano, flush type 6 Amp single pole,one way conforming to IS-3854 complete all as speciifed and as directed. |
| 39 | Supply and fix outlet socket 3 pin 6 amp flush type compelete all as specified and directed. |
| 40 | Supply and fix Switch Piano,flush type 6 Amp single pole, 2 way conforming to IS-3854 complete all as speciifed and as directed. |
| 41 | Supply and fix Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed. |
| 42 | S&F in repair of Building security LED street light fitting 35 Watt 3000/6500K pf >.90 efficency 100lm/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete all as specified and as directed. |
| 43 | S&F in repair of Building security LED street light fitting 60 Watt 3000/6500K pf >.90 efficency 100lm/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete all as specified and as directed. |
| 44 | S&F in repair of Building security LED street light fitting 90 Watt 3000/6500K pf >.90 efficency 100lm/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete all as specified and as directed. |
| 45 | S&F in repair Street light bracket made out of 32/40 mm dia GI light grade tubing not less than .75 Mtr long bend to shape including pole clamps/fastners clips nails made out flat iron and nuts, bolts and washers etc complete all as specified and directed. |
| 46 | Supply only 60–65 W, 4 ft LED batten complete with high-efficiency LED module, integral electronic LED driver, 230 V AC, 50 Hz operation, 6500 K cool daylight, minimum luminous flux 6000 lumens, system efficacy minimum 90 lm/W, CRI ≥80, power factor ≥0.90, THD ≤15%, wide beam angle ≥120°, surge protection minimum 2.5 kV, high-voltage/short-circuit/thermal protection, opal high-transmission diffuser, suitable housing, mounting accessories and all necessary connections, complete including removal of old unsv tubelight of any size. Make: Philips/Havells/Wipro/ LEDURE or approved equivalent. |
| 47 | S&F sheet steel powder coated distribution board SPN 8 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB] |
| 48 | Supply and fix in repiar factory made VTPN DB, 415 V, 4-pole, 4-way, sheet steel enclosure, wall mounting, IP42, complete with TPN copper busbar, neutral link and earth bar, incomer MCCB/isolator and outgoing MCBs, with DIN rail, gland plate, cable terminals and all internal wiring, complete as required including taking down existing unserviceable DB of any size and type embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB] |
| 49 | Supply and fixing in repair MCCBs 80 Amps capacity, 415 volts, 4 pole, 25 KA, thermal magnetic complete all as specified and directed Make Legrand/Siemens/Schneider |
| 50 | Supply and Fix in repair MCB TPN 415 Volts, 80 Amps, 50 Hz, 16 KA 'C' series all as specified and directed Make Legrand or Siemens/Scheinder |
| 51 | Supply and Fix in repair MCB TPN 415 Volts, 63 Amps, 50 Hz, 16 KA 'C' series all as specified and directed Make Legrand or Siemens/Scheinder |
| 52 | M&L Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using GI earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board/panel / test joint, watering pipe 20mm dia with wire mesh and funnel at top, PCC earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site complete all as specified and directed. |
| 53 | Material and Labour for earth continuity conductor or main galvanised iron wire of size 4.00 mm burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed. |
| 54 | M&L in repair MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. |
| 55 | M&L in repair MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. |
| 56 | S & Fixing in repair of 22 W decorative LED square flush-mounted ceiling light fitting, complete with high-efficiency integrated LED module, integral electronic driver suitable for 220–240 V AC, 50 Hz supply, 3000 K warm white / 6000 K cool white, high-transmission acrylic diffuser, sturdy metal base, modern minimalist square design, power factor ≥0.90, CRI ≥80, flicker-controlled operation, complete with ceiling mounting plate, fixing hardware, internal wiring, connectors, earthing arrangement and all accessories required for complete installation and satisfactory operation, as directed by Engineer-in-Charge. Make: ELEPHANTBOAT / / Philips/Havells/Wipro decorative series |
| 57 | Supply and fixing in repair IP 65 MCB Disribution 1 row 3 modules of polycarbonate themoplastic, IP 65 dust proof, jet water tight corrosion proof, halogen & silicon free, with high quality earth and neutral links, internally embedded gasket for led and enclosures made PUR with cable glands and other accessories with MCB 6 amps and required terminals, metric size knock transparent door & with cable enerty covered and suitable to accommodate any make of MCCB and tested as per IEC 60439-3 (Flame retardant self extinguishing of size 202x238x111 mm complete all as specified and directed including taking down old unsv metal DB / pvc junction box. Make : Hensel cat Ref No: KV 7103/legrand/ABB |
| 58 | Supply , laying and passing through pipes/poles cable wheather proof flat copper conductor twin core of size 2.5 sqmm for connection from junction box to pole with flexible conduit of apporipriate size if required at site all as directed by Engr-In -Charge at site including taking down old. ( Make of cable: Havells/polycab/finolex ) |
| 59 | Supply and fix in repairs 24 W Round LED surface lights fitting full glow panel, metal body, natural light 6500K, environmental friendly energy efficient, with driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. (CAT PART NO: Phiilips BOF5HW4QRT)/Crompton/Wipro |
| 60 | Supply and fix in repairs occupancy sensor with light sensor, 360 degree detection angle, energy saving motion detector, auto on & off ceiling mounted, 7 meter radius detection range including taking down old unsv piano switch/ occupancy switch complete all as specified and directed by Engr-in-Charge. (CAT PART NO: Schneider CSS54E_WE) |
| 61 | S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI / IEC 60439-2 approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers make Hensel/Clipsal. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 63A TP 25KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nob Operated by Flip Cover. Indicator Provided on each phase. Six Nos Single Phase Sub-Meters. Output supply by MCB DP 32Amp 6 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply. Make- Hensel/siemens/Emitter/Schneider/ABB. |
| 62 | S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI / IEC 60439-2 approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers make Hensel/Clipsal. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 125A TP 25KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nob Operated by Flip Cover. Indicator Provided on each phase. Eight Nos Single Phase Sub-Meters. Output supply by MCB DP 32Amp 8 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply. Make- Hensel/siemens/Emitter/Schneider/ABB. Please Enable Macros to View BoQ information |
| 63 | S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI / IEC 60439-2 approved OEM made Meter Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and Enclousers make Hensel/Clipsal. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 125A TP 25KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nob Operated by Flip Cover. Indicator Provided on each phase. Eight Nos Single Phase Sub-Meters. Output supply by MCB DP 32Amp 8 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply. Make- Hensel/siemens/Emitter/Schneider/ABB. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender