Tender For B.O.Q For Internal Electrification Of Town Hall Building At Mc Pulwama
Tender Value
23.85 Lakhs
Estimated cost
Bid Submission
11 Nov 2026
9 days left
EMD
47709
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for B.O.Q For Internal Electrification Of Town Hall Building At Mc Pulwama
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab /Finolex /Havells /Anchor make in existing surface / recessed medium class PVC conduit, with 6Amps modular switch, modular plate of Anti backteria series of Schneider /ABB /L&T /Legrand make , suitable GI box and earthing the point with 1.5 s q.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( P+N+e for Normal and invertor points per room is to be provided ) |
| 2 | Wiring for lightl power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surfacel recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. of Polycab /Finolex /Anchor /havells make. |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface / recessed medium class PVC conduit as required. of Polycab / Finolex /Anchor / havells make. |
| 4 | 2 X 1.5 sq. mm +1 X1.5 sq. mm earth wire |
| 5 | 2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire |
| 6 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire with p/f of Copper thimbles of required size and numbers to be fixed on i/p and op sides dully crimped with termination and rolling of colour coded tape |
| 7 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire with p/f of Copper thimbles of required size and numbers to be fixed on i/p and op sides dully crimped with termination and rolling of colour coded tape |
| 8 | 2 X 16 sq. mm +1 X 6 sq. mm earth wire |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. ( Schneider /ABB /L&T /Legrand make , ) |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 2 No's of 3 pin 5/6 A modular socket outlet and 2 No's of 5/6 A modular switch, connections etc. as required. Schneider /ABB /L&T /Legrand make , ) |
| 11 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 12 | Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 13 | Supply and laying of 19-25 mm dia medium class PVC medium grade Conduit to be laid on surface with screws fixed in rowel plugs complete with all allied accrues like bends, tees etc. for paving way of laying of wires of haeting points /circuits ,machine points /circuits and sub mains .The Job includes cutting of walls with required hydraulic cutter and refacing of walls with cement plaster of required ratio or with P.O.P after laying of conduits refacing to its original position by way of supply and applying of painting of required colour to effected area's.Anchor/Polycab/Finolex/TMT Plus make. |
| 14 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/\N) minimum 6.00,Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (ma><.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
| 15 | Supply, Installation testing and commissioning of 200-250 mm sweep Exhaust Fans of Usha / Crompton Greaves / Havel's incl making of necessary connections and making of necessary space in walls / Windows as per site. |
| 16 | Supply, Installation testing and commissioning of 400 mm sweep Wall fans of Usha / Crompton Greaves / Havel's incl making of necessary connections and making of necessary space in walls / Windows as per site. |
| 17 | Supply and fixing of 12-15 Watts LED surface /recess (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing should made of pressure die-cast aluminium. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver |
| 18 | Supply ,Installation ,Testing and Commissioning of 1P 66, 50 Watt LED Flood /Street light Luminaries having Aluminium body of of standard make dully isi marked ,to be fitted on walls / poles with necessary cliffs /Clamps with nuts and bolts complete job.The system efficacy of the luminaire shall be ≥120lm/w. The LEDs used in the luminaire shall be from either Lumileds, Osram, Nichia, APT Electronics and CREE make, shall have CCT of 5700°K, CR≥70, SDCM≤5, Life of 50000Hrs @ L70B50. The luminaire shall have IP rating of IP66 & IK rating of IK07. The luminaire shall have lens made of polycarbonate & optical cover made of toughened glass. The LED driver shall have operating voltage range of 140V to 270V, PF≥0.95 @ full load, THD≤ 10% @ full load, In-built surge protection of 4KV, HV Cut off @ 325V (±15V). The luminaire shall have 10KV SPD in-built inside the luminaire. The maximum dimensions of the luminaire shall be, L: 264M, Depth: 52MM & height without cradle: 203MM. The nominal weight of the luminaire shall be maximum 2.4KGs. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material for approval. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. |
| 19 | Supply, Installation, Testing and commissioning of 36-40 watt ultraslim LED surface mounted lighting panels (300 mm x 300mm Square ) having CRCA Body (Commercial type ) ,minimum lumens 100 lm/w ,the luminaire housing should be crca /aluminium and the luminair optics shall have a high efficency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C of Philips / Havells/ Helonix /Bajaj /Trulux make incl making of necessary Connections. |
| 20 | Supply Installation, Testing and Comissioning of aluminium / gypsum profile channel for LED Strips including mounting brackets and caps , clips , screws etc . The Job further includes providing and instalation of 4 - 5W/M Flexible LED Stripr with high performance LEDs, suitable for mounting in cove for intedirect lighting with non- integral electronic low THD (<10%) LED driver.High efficiency long life LED package in integral module with lumen efficacy of >70 lm/W .Powered by an integrated driver, SELV Output electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test. Lumen Output of 1500lumens.CRI >80, Color temperature 3000K, THD <10% and PF >0.95,IP20,IK03.Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3 KV; Protection : Reverse Polarity, Open & Short Circuit. DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. Approved make Philips / Lighting techology / Trilux /wipro/ Endo / Igguzini /Regent make |
| 21 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) |
| 22 | 6 way (4 + 18), Double door |
| 23 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens make |
| 24 | Supplying and fixing of 40 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make |
| 25 | Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections |
| 26 | Supplying and fixing of 100 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections. |
| 27 | Supply/ installation/testing and commissioning of Wall / floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming (1A) 250 Amp TPN MCCB with breaking capacity of 35 KA thermo magnetic adjustable based of Legrend /Schinder /Simens / ABB make with extended rotory handle and phase spreaders on i/p and o/p side = 1 no (1B) 400 Amp TPN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 40 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT's of ratio 250 A/5A ,CL 1.0 ,15VA .(1D) 3 No's (3 No's) phase indication lamps and 3 No.'s status indication lamp for ON / OFF /TRIP with Control SP MCB (2) Generator Incomer 100 Amp F.P Change over switch of Havels./HPL /Standard make = 1 no200 Amp TPN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT's of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No's (3 No's) phase indication lamps and 3 No.'s status indication lamp for ON / OFF /TRIP with Control SP MCB (3) Generator Incommer 125 Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 1 No 200 Amp PN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT's of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No's (3 No's) phase indication lamps and 3 No.'s status indication lamp for ON / OFF /TRIP with Control SP MCB (4) Outgoing .125 Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 6 No 100 Amps Double Pole MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 6 No63 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make = 6 No The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. |
| 28 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 29 | Supply,Laying,Testing & Commissioning of 120 sq.mm 31/2- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/paramount make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections to be laid as p[er site requirement and as per instructions EIC |
| 30 | Supply,Laying,Testing & Commissioning of 50 sq.mm 2- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/paramount make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections to be laid as p[er site requirement and as per instructions EIC |
| 31 | Supply and laying of heavy duty HDPE double layer Corrigated pipe having 75 mm dia (Inner dia) with allied bends ,collars etc to be laid under ground upto 50 Cm's in deep including execuation and refilling back and disposal of surplus earth complete job. |
| 32 | Supply and installation of 4.5 to 5 KG ,Co2 Fire extinguisher of standard make |
| 33 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job |
| 34 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 35 | Supply,Installation,Testing & Commissioning of 10 KVA Power Inverter (160 Volts) Sine wave type of make (Sukam / Luminous / Exide / Micro tec/Liv guard make ).The invertor shall have inbuilt display unit showing input and output voltage ,Charging voltage , output current etc with having inbuilt protection device of suitable capacity . The invertor should invertor and UPS mode of operation . The job further includes Supply , Installation , Testing & Commissioning of 16 No's of 180 AH /12 V Tall tubular Inverter Batteries of same make as of inverter ,the batteries are to be housed in angle iron Stand incl cost of trolley /Angle iron rack . complete job.The job includes AMC of batteries and invertor for a period of three years ,which includes quarterly servicing of devices & as and when required. complete job. |
| 36 | Providing and laying of shock proof Rubber mats of 2mt. x 1 mt. and 12 mm thick in size |
| 37 | Supply,Installation,Testing & Commissioning of 20 KVA, Single Phase, 230 V, L.T,Unbalanced Servo voltage stabilizer of ALBA / CHINAR / casco /Servokon make , operating from input voltage of (L-N) = 90 -265 V ,thereby producing the output voltage of 230 volts±1%(Phase to neutral) ,The stabilizer Should have inbuilt Over voltage protection , under voltage protection & Overloading with TDR and neutral failure protection .The Stabilizer shall be servo-controlled automatic ,ONAN cooled and provided with first filling of fresh filtered transformer oil having required dielectric strength .The Stabilizer shall be capable of smooth operation upto 10 % un-balanced in the load currents.The Supplier has to give guarantee for any manufacturing defect with three servicing of the equipment for three year reckoned from commissioning.Inclusive of all applicapable taxes . |
| 38 | Supply,Installation,Testing and Commissioning of 63 Amps By Pass Four Pole Change over switch of Havells/HPL Make ,Incl its sheet steel enclosure and Angle iron stand and handle with making of necessary connections complete job. |
| 39 | Supply,Installation,Testing and Commissioning of 63 Amps Four Pole Change over switch of Havells/HPL Make ,Incl its sheet steel enclosure and Angle iron stand and handle with making of necessary connections complete job. |
| 40 | Supply,Laying,Testing & Commissioning of 25 sq.mm 2- core unarmored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/paramount make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections for input and output power supply to stabilizer |
| 41 | 1(a) Providing, Installation, testing and commissioning Single Phase 20 KVA Silent Type diesel driven Generator Set Conforming to CPCB-1V /1V + NORMS of Eicher /kirloskar /Communis/Tata Motors make , comprising of radiator ,4-Stroke multi cylinder engine of suitable BHP to deliver rated KVA at prevailing site conditions equipped with flywheel ,residential type silencer ,fuel governor ,fuel pump, built in fuel tank, electric starting equipment with required nos of suitable AH sealed maintenance free batteries etc., directly coupled to30 KVA, 0.8 PF, alternator suitable for 230 volts , 50 Hz Ac supply system with the entire system mounted on common base frame etc. on an exciting foundation exhuast pipeing with thermal insulation ,control wiring from alternator to control panel acoustisc enclouser, etc. as specified and consisting of the following as per sepecification given below etc as required one number multi cylinder ,four stroke ,liquid cooled ,electric start ,turbo charged type engine suitable for developing the required BHP at 1500 RPM suitable for above output of alternator at 40\\"C. 50% RH and at 1000 Mtere MSL and conforming to BS 5514, BS 649, IS: 10000, capable of taking 10% overloading foer one hour after 12 hours of conitunes operation complete with common base frame, Anti vibration mountings, radiator,starting equipment, batteries, residential type siliencer and other accessories etc. as required and as specefied in the detailed specification enclosed.1(b) Alternator One No. syncronous alternator rated 20 KVA, 230 Volts at 1500 RPM, 1-Phase, 50 Hz AC supply with 0.8 lagging PF at 40ᵒ C., 50% RH and at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless continous duty, self excited and self regulated through AVR conforming to IS; 4722/ BS 2613 suitable for tropical conditions and with class F/H insulations. 1( c) Base frame and foundationBoth the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. |
| 42 | 1(d) Fuel tank:In built daily service fuel tank as per manufactures specification complete with all standard accessories and fuel piping between fuel tank and diesel engine, complete with valves, level indicator and accessories as required as per specification attached.1(e) Exhaust System:Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor.1(f) Starting System:starting system comprising of starter motor, voltage regulator and arrangement for initial excitation, complete with required nos of suitable batteries as required and as per specification.1(g) Acoustic Enclosure:Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air in to the atmosphere as per specification attached. AS PER CPCB-IV/IV+/MOeF regulations.(a) Supplying and fixing exhaust gas piping of suitable dia. Welded black MS 'B' class pipe conforming to IS:3589 cut to required length and installed with necessary bends, supports and clamps, anti vibration mountings, insulation of exhaust system with mineral wool/Rock wool 50mm thick, wire mesh and aluminium cladding etc. as required as per detailed specification to be communicated Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender