Tender For Supply Installation Testing and Commissioning of Fire Alarm And Fire Fighting System At Chc Building Chaukaghat In District Varanasi Up
Tender Value
53.80 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
0 days left
EMD
1.07 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of Fire Alarm And Fire Fighting System At Chc Building Chaukaghat In District Varanasi Up
BOQ
| Sl. No. | Item Description |
| 1 | Providing, Laying, Testing & Commissioning of C- class heavy duty MS pipe on surface Confirming to IS 1239 (part-1) for pipes upto 150mm dia and IS: 3589-1991 for pipes above 150mm including cutting & welding with fitting like elbows , tees ,hanger ,flenges, taper , reducers, nuts, neoprene gasket & washer including cutting, welding etc. fixing the pipe on the Wall / Ceiling with suitable clamp and painted with red oxide and PO red enamel paint complete in all resspects. |
| 2 | 100 mm Dia |
| 3 | 80 mm Dia |
| 4 | 50 mm Dia |
| 5 | 32 mm Dia |
| 6 | 25 mm Dia |
| 7 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 0C with required accessories : Pendent Sprinkler |
| 8 | (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)900 lpm at 35 m Head |
| 9 | Supplying, fixing, testing & commission of butterfly valve of PN-16 slim seal standerd lever operated type as per design standerd IS:1395 or BS:5155 with required flanges, nut bolts etc. complete in all respects. |
| 10 | 150 mm dia |
| 11 | 100 mm dia |
| 12 | 80 mm dia |
| 13 | Providing, installation, testing and commission of non-return valve of following sizes PN-10 as per design standerd IS: 5312 or BS:1868 with companion flanges, bolts, nuts, washers etc. complete in all respects.100 mm dia |
| 14 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m |
| 15 | Supplying Installation testing & Commissioning of 25 mm Air Release valve gunmental having rubber ball and with 25 mm BSP threaded male inlet including necessary accessories and connections complete in all respect. |
| 16 | Supplying Installation testing & Commissioning of 25 mm Ball valve PN-1 gunmental as per IS:778 including necessary accessories and connections. |
| 17 | Providing & fixing of Weather proof standard fire hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door on front painted \\"FIRE\\" in red luminious paint, The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodation a pair of hose with coupling and nozzel. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete. |
| 18 | Supplying and fixing 63 mm dia, 15 m long RRLhose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) |
| 19 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required:Stainless Steel (Grade 304) |
| 20 | Supplying and fixing Single headed external yard hydrant valve with 1No.63 mmdia instantaneous FM Gunmetal/Stainless Steel coupling and cast ironwheel,ISI marked, conforming to IS5290 (typeA)with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 21 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.. |
| 22 | Providing & fixing of pressure gauge in ranging from 0 to 14 kg per sqmm ISI marked from approved manufacturers complete in all respects. |
| 23 | Providing/Fixing of Cubical type floor mounted Fire pump Control panel fabricated from 16 G M.S. sheet duly powder coated finish of aproved shade and comprising of:a) One 63 amp.TP+NL M.C.C.B. with rotary handle of beacking capacity 35 KA.b) One Volt meter (0-500V) with selector switch.c) One set including lamps |
| 24 | Supply and laying of alluminium conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on side and on top on surface the cable run shall be fied on M.S. clamps etc. of suitable size or as directed by the Engineer-in-charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.10 sqmm 4 core |
| 25 | Supply, Installation, Testing & commissioning of Single/Double sided Signage with 20 mtr. viewing distance with built in LED, High efficiency L80 LED with 50,000 hour life, Usage: Exit Signage cum Emergency light with Function Use either as an emergency luminaire or exit sign,with standalone Testing system, Housing of Polycarbonate, Glow wire test : 850°C, RAL9003,Type of mounting: Wall or ceiling, Operation Mode Non -Maintained or Maintained mode selectable, Connection voltage 230V +/- 5% [220V-240V], compliant with EN standards, with IEC CB test certificate LED, Built in Battery: Ni-Cd, Duration 3 hours,Viewing distance 2+A300m, Dimensions in mm: 270 x 119 x 49. |
| 26 | Providing and fixing pressure switch in M.S. pipe line including connection as required |
| 27 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 28 | Providing & laying pipe of required dia including cutting the road & surface dressing complete in all respect as directed by engineer-in-charge. |
| 29 | Cost of minor repair / repainting or necessary works after installation of fire figting works. |
| 30 | Supply & fixing of CO2 type fire extinguisher,4.5 kg.capacity (ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 31 | Supply & fixing of Modular fire extinguisher, ABC type 6.00 kg. capacity (ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 32 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 33 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 34 | Fire Alarm System |
| 35 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 + 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel |
| 36 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 37 | Supplying Installation testing & Commissioning of Addressable Manual Call Point complete with base as required. |
| 38 | Supplying Installation testing & Commissioning of Addressable horn cum strobe complete with base as required. |
| 39 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 40 | Supplying Installation testing & Commissioning of fault isolator complete with base as required. |
| 41 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V with annealed copper conductor having glass mica fire barrier tape covered by extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation LSZH inner bedding, steel wire armouring & LSZH outer sheath |
| 42 | Construction of boring with 2.5 H.P Submersible Pump Set, |
| 43 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 150mm diaUpto 90 metre depth below ground level. |
| 44 | Beyond 90 metre & upto 150 metre depth below ground level. |
| 45 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (I) 110 mm nominal size dia |
| 46 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (I) 110 mm nominal size dia. |
| 47 | Supplying, filling, spreading & leveling p gravel of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 48 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 49 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of : 110 mm dia |
| 50 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 110 mm clamp. |
| 51 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 110 mm dia. |
| 52 | PUMPING SET KSB make submersible pump set suitable for installation in bore well of min 110 mm inner dia preferably more and having under noted specifications.[2.5 H.P.] |
| 53 | Water supply tanker of 5000 litre capacity |
| 54 | Supply and fixing of nylon jali around the slotted pipescomplete as required. Up to 10 meter |
| 55 | Supply and fixing of finolex of copper cable ISI marked submersible cable of size 4 sq mm |
| 56 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 40 mm dia nominal bore |
| 57 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 58 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 59 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 60 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources). (DSR-2023, 5.1.2) |
| 61 | Centering and shuttering including strutting , propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete. |
| 62 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 63 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. |
| 64 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 65 | GST EXTRA AS PER APPLICABLE Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender