Tender For Providing Of Defi Jcos Single Living Accn & Religious ,Installation Under Ge (E) Lucknow
Tender Value
1.88 Crore
Estimated cost
Bid Submission
27 Nov 2026
5 days left
EMD
2.64 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Providing Of Defi Jcos Single Living Accn & Religious ,Installation Under Ge (E) Lucknow
BOQ
| Sl. No. | Item Description |
| 1 | Sch 'A' Part-I (Building Work)Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5. |
| 2 | Total amount of Sch 'A' Part II (SITE CLEARANCE, EXCAVATION AND EARTHWORK) |
| 3 | Total amount of Sch 'A' Part III (INTERNAL WATER SUPPLY ) |
| 4 | Total amount of Sch 'A' Part IV (INTERNAL ELECTRIFICATION) |
| 5 | Total amount of Sch 'A' Part V (ROAD PATH AND CULVERT) |
| 6 | Total amount of Sch 'A' Part VI (AREA DRAINAGE) |
| 7 | Total amount of Sch 'A' Part VII (SEWAGE DISPOSAL) |
| 8 | Total amount of Sch 'A' Part VIII (EXTERNAL WATER SUPPLY) |
| 9 | Total amount of Sch 'A' Part IX (EXTERNAL ELECTRIFICATION) |
| 10 | Total amount of Sch 'A' Part X (HOT WATER SUPPLY, REFRIGERATOR AND WATER COOLER & DESERT COOLER ) |
| 11 | Total amount of Sch 'A' Part XI(AIR CONDITIONING) |
| 12 | Total amount of Sch 'A' Part XII (RAIN WATER HARVESTING) |
| 13 | Sch 'A' Part - XII(Miscellaneous Items for B/R and E/M works)Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as \\"Rs 0.00 under col.5 siginifies this fact only. |
| 14 | INTERNAL ELECTRIFICATIONM & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked) not less than 20 mm dia with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLSH PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and directed. Note : Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained at no extra cost. |
| 15 | Ditto all as item No. 13.01 above but for One Light/Ceiling fan/Exhaust fan controlled by one switch all as specified and directed. |
| 16 | Ditto all as item No. 13.01 above but for One LED Light point point controlled by 2-way switches all as specified and directed. |
| 17 | Ditto all as item No. 13.01 above but wiring with 2.5 Sqmm for one 3 Pin switch socket outlet 5Amp on the independent board all as specified and directed. |
| 18 | M & L for point wiring wiring with 2.5 sqmm for one 3 pin switch socket oulet 15 Amps on the independent board, FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked) not less than 20 mm dia with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLSH PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified & directed by Engr-in-charge. Note : Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained at no extra cost. |
| 19 | S & F Wall Mounted Fan 600mm 230Volt 50Hz and proper fixing on the wall and connecting to ceiling rose with suitable size wire testing and commissioning complete all as specified and directed. |
| 20 | S & F MCCB VTPN DB 4 - Way sheet metal enclosure 415V with 200 Amp fully insulated strandard copper Busbar for wach phase & sourrounded with Neutral bars & two cpmmon neutral Bars, two earth bar incl cable ties for cable management suitable for housing MCCB/TPN 415V as incomer IP-54 protection with metal door all enclosed on strandard steel sheet flush mounted type double door factory favricated complete without MCB & MCCB but with enclosure blank plate complete all as specified & directed. Note:- Independent GI pipe incl connected items of suitable size will be laid in concealed in wall for each floor for XLPE cable 16/25 sqmm 4 core cable connection. |
| 21 | Sewage Disposal: Providing, supplying and laying of SWC pipe, Class SN-8 Structured wall polyetethene piping system of 150 mm internal dia (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated and Smooth Internal surface (Double Wall) for non-pressure underground Sewage & Drainage application confirming to IS : 16098-2013 including all materials, labour T&P reqired for proper completion of work complete all as specified and directed. |
| 22 | M&L for LLDP conventional Septic Tank for 25 users designed to carry sewage and sullage water , excavation in any type of soil , PCC 1:4:8 below foundation Vent shaft connection etc complete all as specified and directed. |
| 23 | M&L for Soakage Well excavation, in any type of soil, foundation in PCC 1:3:6, walls of honycombed masonary with top ring of M-25 concrete including interseptic chamber and screen chamber of brick masonary in CM, RCC cover slab in CM, RCC cover slab in M-25 / SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia and 3 m effective depth complete all as specified and shown in drawings No TD-576 Sheet 1/2 & 2/2. |
| 24 | EXTERNAL WATER SUPPLY Ductile iron pipe of size 80 mm dia socket and spigot Class-K-7, double flanged and laid in trenches including rubber gasket joint and other accessories as required at site etc complete as specified and directed. |
| 25 | Cast iron sluice valve of size 80 mm heavy duty both ends flanged class PN 1.0, ISI marked with high tensile brass spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3 mm thick rubber gasket joints etc complete all as specified and directed. |
| 26 | Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 leavers and in duplicate key (Make - Godrej ) or equivalent make as approved by GE complete including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed. |
| 27 | EXTERNAL ELECTRIFICATION:Supply and fix street light luminaries suitable for LED 70-75 watts new generation energy saving and enviromental long life made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP -66 protection and impact resistnace of IK07 suitable for 41mm dia pipe including 2 single core 1.5 sqmm PVC insulated stranded copper conductor cable from junction box to light fitting connector etc complete as specified and directed. |
| 28 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to galvanized strip of size 32x6mm by means of nuts, bolts, washers of GI and brazing the around joints all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI pipe light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI pipe light grade earth lead protection pipe, complete all as specified and directed.Note : (i) Main earthing lead and protection pipe from earth plate electrode to test point upto length of 7.50 mtr shall deem to be included in the unit rate quoted by the tenderer against this item.(ii) GI protection pipe and earthing strip beyond 7.5 mtr long shall be measured and paid seperatly .(iii) Test result should be less than 1 ohms or satisfaction of user.(iv) Coal and salt not less than 60 kg and 110 kg respectively. |
| 29 | S&F MS Junction box of size 300 x 200 x 150 mm grade made from 16 gauge steel sheet with 04 Nos aluminium bus bar of size 25 mm x 3 mm fixed on porcelain support with hinged cover and locking arrangement fixed to pole with ms clamp of size 25x3mm thick and tighting with nut bolt and washer and duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour etc specified and directed by EIC |
| 30 | S&F stellar LED post top lantern fitting 60 watt offering combination of sturdy deisgn , execllent illumination and aesthetics in on go IP 66 and IK10 rating ensures it stantd tall amid varid environmental conditions suitable for 76 mm dia etc with all accessoreis incl suitable size GI pipe and fixing in RCC wall/floor etc complete as specified and directed Make Havells NEBULAPT60WLED857PSYMTOPCO or quivalent approved by EIC |
| 31 | Supply installation,testing and commissioning factory made CPRI approved LT panel outdoor type , dustproof , vermin proof board fabricated out of 3.15 mm thick CRCA sheet fixed with necessary angle iron support, of suitable size on PCC Base type B1(1:2:4) above floor duly powder coated paint complete using lugs and glands for cable connection all as specified and directed :-( Religious Institute)(a) 4 Nos Copper bus bars, 3 Nos for phase (R,Y,B) of rating 200 Amp and 1 for neutral rating 200 amp mounted on heavy duty rubberised / porcelain support.(b) MCCB 125 Amp,35 KA, 4 pole 415V, 50HZ - 02 No Incoming (1+1 Spare)(c) MCCB 100 Amps 25 KA , 4 pole 440V, 50HZ - 01 No (AC)(d) MCCB 63 Amps 25 KA , 4 pole 440V, 50HZ - 01 No (Light & Power)(e) MCCB 20 Amps 25 KA , 4 pole 440V, 50HZ - 01 No (Street light)(f) Digital Ammeter (0 -100) ampwith selector switch and suitable CTs -1 No(g) Digital Voltmeter (0 - 500) V with selector switch- 1No(h) Indicator lamp LED type (set of 3)(i) Digital Timer Switch-01 Nos(j)Power Contractor suitable capacity -01 Nos |
| 32 | HOT WATER & DESERT COOLER :S&F wall mounted air cooled voltage stabilizer 1 KVA for automatic voltage correction single phase naturally air cooled indoor type and designed for input variation between 160 V to 260 V with out put voltage stabilized at 220 Volts ± 2.5% volt and high low voltage cut off with facility of incl. instant start & time delay relay of 3 minute capacity complete all as specified and directed Make Blue tech/Blue Bird/Volina or equivalant. |
| 33 | Supply and fixing air cooling units suitable for easily removal and cleanable cooling pads ,4000 cfm capacity (desert cooler) side discharge , nominal air delivery 4000 CMH , cooling area upto 1800 sqfit , net weight 24 Kg and operating weight 30 kg , input power supply 230 V . 50 Hz, motor power 230 Watt outlet dimension 870 X 440X 1400 mm , body material UV stabilized high grade plastic, water tank capacity 120 ltr ,air moving device fan and its diameter 525 mm , cooling media honeycomb pads , thickness 60 mm , minimum cooling efficiency 75 % , Nos of speed 3 Nos, fully closable horizontal louvers auto vertical swing low power consumption three side dust filters cool flow despenser for enhanced cooling ,float valve includng all accessories such as 3 side honeycomb cooling pads for enhanced cooling robust resistance body or long life power ful air through for faster cooling , electric supply and testing complete as per manufacturer as specified and directed Make Symphony or equivalent AO approved .Note cutting proof Bricks /pcc/rccb wall /roof /window etc. included in quoted rate.. |
| 34 | AIR CONDITIONING :Supply, installation, commissioning and testing 1.5 TR wall mounted split air conditioner 5 star rating invertor type fitted with reciprocating compressor operating 220 ± 10% single phase AC supply with evaporator and condensing unit made of copper tubes with aluminium fins ,cord less remote control, , copper piping for both suction and discharge with PUF insulation and protection covering pipe of suitable size of medium PVC pipe (cashing and capping ) power and control cabling as per site requirement (not less than 2.5 sqmm 3 core) , MS outdoor stand dully painted , comprsing of the following etc complete as per requirment (a) Insulating copper pipe line between indoor and out door unit of suitable size as per manufacturer recommendation.(b) Flexibile copper cable between indoor unit to out door unit of suitable size as per manufacturer recommendation (c) Suitable size of PVC pipe for protective covering refrigerant line.(d) Fixing the cooling unit with grouting nuts, cutting groove to wall for gas pipe and water drainage pipe complete.(e) S & F drain pvc pipe 20 mm dia transparent flexible heavy duty for drainage pipe upto floor level.(f) Charging of correct quantity refrigerant gas after necessary brazing/fixing of both the outdoor/indoor unit and testing complete.Note - (i) All other connected civil works and other miscellaneous works required for installation of split AC & proper functioning as directed by Engr-in-charge (ii) Additional length of copper tubes for compressor inlet/outlet with insulating material shall be inclusive in unit rate. |
| 35 | Supply, installation, commissioning and testing 2.0 TR (hot and cool) wall mounted split air conditioner 5 star rating invertor type fitted with reciprocating compressor operating 220 ± 10% single phase AC supply with evaporator and condensing unit made of copper tubes with aluminium fins ,cord less remote control, , copper piping for both suction and discharge with PUF insulation and protection covering pipe of suitable size of medium PVC pipe (cashing and capping ) power and control cabling as per site requirement (not less than 2.5 sqmm 3 core) , MS outdoor stand dolly painted , comprsing of the following etc complete as per requirment (a) Insulating copper pipe line between indoor and outer door unit of suitable size as per manufacturer recommendation.(b) Flexibile copper cable between indoor unit to out door unit of suitable size as per manufacturer recommendation (c) Suitable size of PVC pipe for protective covering refrigerant line.(d) Fixing the cooling unit with grouting nuts, cutting groove to wall for gas pipe and water drainage pipe complete.(e) S&F drain pvc pipe 20 mm dia transparent flexible heavy duty for drainage pipe upto floor level.(f) Charging of correct quantity refrigerant gas after necessary brazing/fixing of both the outdoor/indoor unit and testing complete.Note - (i) All other connected civil works and other miscellaneous works required for installation of split AC & proper functioning as directed by Engr-in-charge (ii) Additional length of copper tubes for compressor inlet/outlet with insulating material shall be inclusive in unit rate. |
| 36 | S&F wall mounted air cooled voltage stabilizer 5 KVA for automatic voltage correction single phase naturally air cooled indoor type and designed for input variation between 160 V to 260 V with out put voltage stabilized at 220 Volts ± 2.5% volt and high low voltage cut off with facility of incl. instant start & time delay relay of 3 minute capacity complete all as specified and direccted.Make: Blue tech/Blue Bird/Volina or equivalant. |
| 37 | M&L epoxy powder coated or polystrene insulated material sheet metal enclosure, factory made (double door), 4 way VTPN suitable for MCCB DB's, 415 Volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting suitable for the following complete all as specified and directed. Make : Legrand/Havells or equivalent .(a) MCCB 3 pole 100 A, 25 KA- 01 No(b) MCB SP 32 A, 10 KA C series-12 Nos |
| 38 | Solar PV SystemDesign procure, erection, installation, testing and commissioning including to local utility grid; roof top On grid Solar photovoltaic Plant of 15 KW Capacity including Solar Photovoltaic Modules, Dc Cabling, module mounting structures, Array combining Boxes Lightning Protection of SPV modules and other accessories, Central Inverter and Power conditioning Unit, Weather station and data monitoring System all as per detailed specifications given in Particular specification, latest MNRE /REDA guidelines and directions, meeting the domestic content requirement (dcr), consisiting of all requisite accessories (BOS - Balance of system) and including the following main components :- Make ;1 Make of Modules/ Solar PV panel shall be as per MNRE approved list of manufactures and modules having IEC/BIS certificate1.Inverter /PCU - shall have BIS certification and 10 yr warrenty |
| 39 | Crystaline Silicon Solar Photovoltaic Modules TOPCon N type Bifacial technology (efficiency will have higher le conversion of not less than 575 Wp or more (module power and no. of modules to be selected according top available roof top area & adequate walkway), having cell efficiency under standard conditions, form fill factor more than .76, plant performance ratio >75 %, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90 % and bending less than .3 %. The modules shall have the features as per detail in PS specified :-(a) The electrical parameters of SPV modules under standard test conditions of irradiance 1000 W/Sqm, AM 1.5 Spectrum and temp 25 degree Celcius shall be under:- (b) Rated output of the modules shall have positive tolerance of 3-5 % and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85 % with temperature upto +85 % degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt caapcity, and it shall not fall of its initial value below 90 % in first 10 year end and 80 % after the end of 25 year. |
| 40 | (e) Each module shall have RFID tag encapsulated with solar cell bearing following details:-(i) Name of Manufacturer of SPV module(ii) Name of Manufacturer of Solar Cell(iii) Month and year of Manufacturing (separately for cell and Module)(iv) Country of Origin (both cell and module (Make in INDIA only)(v) Peak Wattage, Im, Vm and fill factor of the module(vi) Date of year of obtaining IEC PV Module qualifiaction certificate including the test lab issuing IEC certificate.(vii) Unique Serial o and model no of module(viii) IV curve of module(f) The temperature coeficient of power for the module shall not be more than5% per degree Celcius.(g) Every module must have bypass diode of suitable capacity(h) PV module must confirm to latest edition of IEC 61215/IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID or the latest relevant international Electrotechnical Commission (IEC)(i) It shall also be in confirmity to latest minimum technical specification issued by MNRE & IREDA from time to time. Modules should be of MNRE & IREDA approved companies and as per latest IEC/IS standards |
| 41 | RFID reader is to be provided nby contracterEach structure should have angle of inclination as per the site conditions to generate maximum power. However, to accumulate more capacity the angle inclination may be adjusted or as per lEC guideline until the plant meets the specified performance ratio requirementsAny damage to the existing roof treatment of any type due to the installation of Solar PowerSystem shall be Redone/made good as per existing requirements Any damage to the existing roof treatment of any type due to the Installation of Solar Power Plant shall be Re-done /made good as per existing treatment. Cost of the same shall be included in the unit rate quoted. Nothing extra shall be admissible on this account. |
| 42 | (B) Junction boxes. Supply and fix junction boxes of suitable Nos (as per design / OEM recommendations inputs and suitably rated output having sepaarte DC fuses for both (+) & (-) on input and isolator on output terminal for each string, Each Junction box must have a spare input terminal. The junction boxex shall be dust and vermin proof and water proof made of FRP /Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relecant standard. The junction box shall have suitable arrangement of the following:- (a)The strings arerequired to be connected to the copper bus bar through individual fuses. (b)Provide arrangement for disconnection (DC dis connection switch) for each SJB /SCB. (c)Provide a test point for each sub group for quick fault location and to provide group array isolation.(d)Each array box shall be of relevant IEC standard(e)Each array junction box shall have suitable arrangements of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98 % confirmed. |
| 43 | DC cables suitable size of XLPE insulated tinned copper cable as per latest IEC /IS specification and UV resistant for outdoor installations confirming to IEC: 60227/15694 & 60502 /IS: 1554 (PT 1 & II) and shall be as under:-(i)Solar Cable -From Module to DCDB & inverter - IC X 6 Sqmm tinned copper cables. UV resistant, Solar Cable, TUV certified 1800 Vdc(ii) AC Cables (Inverter to AC distribution box - 4 C X 25 sqmm power cables cu conductor LPE insulation, unarmoured PVC outer sheath 1100 V (Flexible Type)(a) All cables and connectors for use of installation shall be of Solar grade which can withstand harsh environmental conditions including high temperatures UV radiations rain dirt, burial and attack by moss and microbes for 25 years and voltage as pef latest IEC /IS(b) All cables / wires shall be provided withh UV resistant printed ferrules for DC side (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5 %.(d) The Wiring of the module interconnection shall be in UPVC /HDPE pipe of suitable or as per OEM recommended.(e) The cost of interconnecting DC copper cable (not less than 6 Sqmm of size), MS cable trays and earth work for trenches /MS cable trays suitable to accomodate Solar grade cables from or as per OEM recommended. |
| 44 | Module Mounting structure (MMS) design, procure, fixing support structure made of hot dipped galavnised with min 85 micron thickness including necessary PCC foundation and associated work (cutting, grouting, PCC filling, dispoing waste material etc. complete) and fixing mounting arrangement suitable for SPV modules so as it can withsatnd wind speed of 200 Km per hour. The mounting structure is to installed at RCC Roofs and the array structure has to be designed that maximium load is directly on roof beams and coloumns It shall also occupy minimum space without sacrificing the output of SPV panels & adequate space between th arrays shall be available for easy cleaning and maintenance. Nuts bolts, mounting structure including module mounting shall have to be adequately protected from the atmoshphere and weather prevailing in the area. All the fasttners shall stainless Steel of grade SS316.Notes :- (a) Anti theft fastners of stainless Steel on MMS be provided for each module(b) The module mounting strutures shall be of fixed to provide maximum generation. (c) MMS design shall be vetted by Govt engg college/Institute and approval be accorded by CWE /GE(I)(d) The height of Roof top MMS shall be as per latest MNRE & IREDA guiidelines |
| 45 | Lightening Protection for PV Array:- Design, procure and fix lighting arrestor system confirming to IS 15086/ IEC 62305 Part 1-4 on the roofs. The air terminals shall be fixed at the top of GI elevation pole with base so as per IEC specification /IS, the structure to be protected. Its height above roof level sahll be depend upon the level shall be depend upon the level of protection and radii reqd as per lEC specfication. Notes (a) The cost of all equipments, copper strip upto earth test point, LA, etc shall be deemed to be included in this item(b) the Cost of sufficient earthing for lightning protection is also included in this item directed by engnr- in charge and no extra payment will be made to the contractor on this account.(c) Provn of Earthing, numbers of earthing and earth strip / cable etc for earth of solar PV medula, arra, inverter, dc & ac boxes and for LA etc as per latest IS/MNRE & IREDA norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account in case of any dispute decision of AO will be final and binding to the contractor. (the earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). |
| 46 | (F) Power Handling Unit:- Procure, fixing, testing and commissioning of 50 KW AC (nominal power), Solar power Inverter suitable to convert DC Power of Solar PV module /array to AC for further feeding to grid confirming to IEC :61683 for efficiency, IEC 62109-01 or equivalent for safety and IEC :62093 for reliability. The Input DC & output AC tcehnical specifications of inverter as specifications in PS. Input DC and Output AC Solar Grid Tie Inverter (output AC) all parameter for output of inverter specified in PS (p) Operating temperature upto 85 degree Centigrade(q) The Inverter shall minimum IP- 67 protection ground fault monitoring, grid monitoring, protection for antiislanding, Dc reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature(r) The inverter shall adjust voltage and frequency levels tos suit the grid(s)The inverter shall be self commulated with Pulse Width Modulaytion (PWM) technology and shall be capable of synchronise maximum with in one min. |
| 47 | (t) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be protected by suitable capacity of MCCB.(u) Monolithic design of inverter is not permitted.(v) the Inverter shall have suitable nos of protected inputs as per design and outgoing shall be protectedby suitable capacity of MCCB.w) The Inverter monitoring portal should be on company 's website and mobile based application (x) The Inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (y) The Inverter shall include appropriate self protection and self diagnostic feature to protect itself and the PV array from the damage in the event of inverter componant failure or from parammeters beyond the inverters safe operating due to internal and or external causes inverter shall have arrangement for adjustment for adjusting DC input curent and shall trip against sustainable fault down stream and shall not restart till fault is rectified(z) The Inverter should have provn of Galvanic isolation, anti islanding protection 1547/UL 1741 or equivalent IS and lightening (aa) PCU must havethe feature to work in tandem with othe similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations variations during the day.(bb) inverter generated harmonics, flicker, DC injection limits, Volt range, frequency range and antislanding measures should follow latest IEC 62116/BIS Code. |
| 48 | (H) Balance of System (BOS) Items/Components : - The BOS items/components of the SPV power plants/systems deployed under this project shall conform to the latest edition with certificate of IEC or quivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of \\"Minimal Technical Requirements'/ 'Standards for SPV System/ Plants' to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender.Notes: (a) The contractor must visit the site before quoting the rates for this item to asses the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete.(b) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work Please Enable Macros to View BoQ information |
| 49 | (H) Balance of System (BOS) Items/Components : - The BOS items/components of the SPV power plants/systems deployed under this project shall conform to the latest edition with certificate of IEC or quivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of \\"Minimal Technical Requirements'/ 'Standards for SPV System/ Plants' to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender.Notes: (a) The contractor must visit the site before quoting the rates for this item to asses the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete.(b) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysDec 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents