BOQ
| Sl. No. | Item Description |
| 1 | Removing cement plaster from wall including racking joints 12mm deep and removing the debris within 50mt.Lead etc. complete as per direction of Engg-in-Charge . |
| 2 | Dismantling brick or stone masonry in lime or cement mortar above 3. m height including stacking the useful materials for reuse and removing the debris with in 50. m Lead. |
| 3 | Dismanteling & removing RCC columns, beams, slab, staircase landing, lintels including stacking the useful materials for reuse and removing the debris with in 50. m Lead. |
| 4 | Removing old grading plaster from roof slab, cleaning the surface, lowering and removing the debris within 50m lead etc complete as per direction of Engg-in-Charge . |
| 5 | Brick work with fly ash brick having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ± 8 percent in cement mortar (1:6) in superstructure in first floor. |
| 6 | R.C.C. work M-20 grade using 20mm.and down grade HBG crusher broken chips including hoisting,laying, cost,conveyance and royality of materials curing including centering and shuttering etc. complete as per direction of Engg-in-Charge in first floor. |
| 7 | Lintel |
| 8 | Column & Beam |
| 9 | Sunshade & Chajja |
| 10 | Roof Slab |
| 11 | Supplying,fitting and placing uncoated HYSD bar reinforcement as per drawing and technical specification including cost,conveyance and all taxes of steel and binding wire etc.complete as per direction of Engg-in-Charge in first floor. |
| 12 | 2.5cm.grading concrete (1:2:2) on roof slab using 6mm.size CBHG chips including cost,conveyance and royalty of materials curing etc.complete as per direction of Engg-in-Charge in first floor. |
| 13 | 16mm. thick cement plaster in c.m. 1:6 over brick masonry including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge in first floor . |
| 14 | 12mm. thick cement plaster in c.m. 1:6 over brick masonry including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge in first floor. |
| 15 | 6mm. thick cement plaster (1:4) to R.C.C. surfaces finished smooth including closed deep chipping and slury treatment, cost , conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charget in first floor . |
| 16 | Wall Priming one coats on new work with wall water bound primer of approved shade as per direction of Engg-in-Charge in first floor . |
| 17 | Wall painting two coats on new work with Distemper of approved shade etc. complete as per direction of Engg-in-Charge in first floor . |
| 18 | Wall painting two coats on new work with Weather coat paint of approved shade as per direction of Engg-in-Charge in first floor . |
| 19 | Wall painting two coats on new work with Weather coat paint of approved shade as per direction of Engg-in-Charge in ground floor . |
| 20 | Fixing colour Vitrified tiles in floors (Printed Series) of size 600mm x600 mm of approved make conforming IS:13755 laid on 20 mm thick cement mortar (1:1)and filling joints with white cement of approved quality including cost of all materials, labour T&P etc rrequired for the work all completeas per direction of Engineer-in-charge in first floor. |
| 21 | Fixing Floor tiles in floors,treads or steps and landings on 25 mm thick CM (1:1) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, polishing & cost of marbel tiles etc. complete as per direction of Engg-in-Charge in first floor. |
| 22 | Fixing Vitrified tiles in dados (Printed Series) skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing complete as per direction of Engineer-in-charge in first floor. |
| 23 | Fixing Ceramic Glazed wall tiles in dados skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing complete as per direction of Engineer-in-charge in first floor. |
| 24 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete |
| 25 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 26 | Supply fitting and fixing MS grill with Iron work wrought and put up in window grating including drilling holes in choukathas etc. complete as per direction of Engg-in-Charge. |
| 27 | Enamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge. |
| 28 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete including Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement , including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer’s specification and direction of Engineer-in-charge. |
| 29 | Supplying , fitting and fixing of grid mineral fibre ceiling boardhaving size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures. |
| 30 | Supplying and fixing of Wall paneling made of aluminum anodised section framing conforming to standard Aluminium sections as horizontal and vertical members with atleast 600mm c/c and fixing of 9mm thick BWR ply with 4mm thick veneer pasting finished with melamine polishing complete. |
| 31 | Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete. |
| 32 | Cutting holes through existing brick work including making good the same in cement mortar 1:4 for taking G.I pipes and fittings P.V.Cpipes and fittings all complete as per Engg.-in- charge.250mm wall |
| 33 | Supplying, fitting & fixing of 1000 liter capacity water storage tank along with construction of appropriate staging for fixing of the same as per specification and direction of engineer in charge. |
| 34 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge |
| 35 | 40mm dia PVC pipee |
| 36 | 25mm dia PVC pipee |
| 37 | 20mm dia PVC pipee |
| 38 | 15mm dia PVC pipee |
| 39 | Laying in trenches unplasticised PVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by heat application method including testing as per specification etc. complete. |
| 40 | 110mm dia PVC pipee |
| 41 | 90mm dia PVC pipee |
| 42 | 75mm dia PVC pipee |
| 43 | Fixing wash down water closet (Europian type WC ) with integral 'S' and 'P' trap to the floor with wooden plug and chromum plated screw including jointing the trap including eat cover all complete etc. complete. |
| 44 | Fixing 10 litres capacity low level Flushing Cistern with a pair of cast iron or M S brakets complete with fittings such as siphonic arrangement including all fittings etc. complete as per direction of Engg. in charge. |
| 45 | Fixing Wash Basin of size 450x300mm with hole for pillar type with cast iron or M S bracket painted white including cutting holes in the walls and making good the damages etc. complete as per direction of Engg. in charge. |
| 46 | Fixing Flat Back Standing Urinal(Gents) of size 340x280x385mm including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc. complete as per direction of Engg. in charge. |
| 47 | Fixing (Squatting Urinal(Ladies) of size 450x350x85mm including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc. complete as per direction of Engg. in charge. |
| 48 | Fixing of brass screw-down Bib cocks(Taps) polished bright of the following nominal size as per specification etc. complete as per direction of Engg. in charge. |
| 49 | 15mm long body |
| 50 | 15mm short body |
| 51 | Fixing of brass Angle Stop Cock polished bright of the following nominal size as per specification etc. complete as per direction of Engg. in charge. |
| 52 | Fixing of brass Concealed Stop Cock polished bright of the following nominal size as per specification etc. complete as per direction of Engg. in charge. |
| 53 | Fixing of brass Pillar Cock polished bright of the following nominal size as per specification etc. complete as per direction of Engg. in charge. |
| 54 | Fixing of brass Over Head Shower polished bright of the following nominal size as per specification etc. complete as per direction of Engg. in charge. |
| 55 | Fixing of Brass or Gun Metal Full Way Valve of the following nominal size with wheel as per specification etc. complete as per direction of Engg. in charge. |
| 56 | 40mm dia |
| 57 | 25mm dia |
| 58 | Fixing of 600mmx450mm Bevelled Edge Mirror of superior glass mounted on 6mm thick AC sheet or plywood sheet and fixed to wooden plugs with chromimum plated brass screw and washers as per specification etc. complete as per direction of Engg. in charge. |
| 59 | Fixing standard size chromimum plated Brass Towel Rail complete with chromim plated brass bracket fixed to wooden/pvc plugs with chromomum plated brass screw complete as per specification etc. complete as per direction of Engg. in charge. |
| 60 | Fixing standard sizechromimum plated Brass Soap Disk complete with chromim plated brass bracket fixed to wooden/pvc plugs with chromomum plated brass screw complete as per specification etc. complete as per direction of Engg. in charge. |
| 61 | PVC Connection pipe complete as per specification etc. complete as per direction of Engg. in charge. |
| 62 | Fixing of brass health faucet polished bright of the following nominal size as per specification etc. complete as per direction of Engg. in charge. |
| 63 | Supply, fitting, & fixing of following components at proper places, all complete in ground floor & first floor as per specification and direction of engineer in charge. |
| 64 | 110mm single junction with door |
| 65 | 110mm plain tee with door |
| 66 | 110mm pipe clip |
| 67 | 110mm PVC vent cowl |
| 68 | 50mm dia GI Elbow |
| 69 | 50mm dia GI Union |
| 70 | Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havells / V Guard /Rhino/RR Kabel/Polycab/Mescab) |
| 71 | Group - A |
| 72 | Group - B |
| 73 | Group - C |
| 74 | Supply& fixing of Modular type 6 Amp one way switch and 6 A socket outlet with metal box and modular cover Separate Board on surface or recess including all conection as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION)) |
| 75 | Supply and fixing of modular metal box on surface or recess with suitable size of modular cover in front including providing an fixing of ISI marked 16Amp modular plug with switch with all conection. on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION) |
| 76 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm 1700 cmh air delivery with louvers of exhaust fan in the existing wall, including fixing & conntection complete etc.as required and as per the direction of E.I.C..(Make-USHA (Model.Turbo HDEF 1400 RPM ISI)/Eq. model of /Havells/ ALmonrad/ Crompton |
| 77 | Submains:Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. |
| 78 | 4 x 6.0 sq.mm. + 2 x 4 sq.mm. |
| 79 | 2 x 4.0 sq.mm. + 1 x 1.5 sq.mm. |
| 80 | 2 x 2.5 sq.mm. + 1 x 1.5 sq.mm. |
| 81 | 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. |
| 82 | Supply & fixing batten holder/BK angle holder ISI marked including connection etc. |
| 83 | Providing and fixing 25 mm x 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode as required. |
| 84 | Supply Installation, testing & commissioning of 32 Amp DP main switches of following capacity (IS 13940 part 3/1993) on existing surface/ wall mountunting & complete with HRC furse link interconnction, earthing etc. as required. |
| 85 | Supply and fixing of 12 watt LED bulb |
| 86 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. |
| 87 | Supplying and fixing 63/40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years.. |
| 88 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 89 | Supplying fitting and fixing of wall mounted fan of make,(USHA,HAVELS,CROMPTON ETC) |
| 90 | Supplying fitting and fixing of 1.5 Ton 5/3 star inverter Air Conditioner of make Voltas,CARRIER,Daikin,LG, Samsung inside the Conference hall . |
| 91 | Supplying fitting and fixing of stabilizer of 5 KVA for 1.5Ton 3 star Air Conditioner of make(V-guard,Luminos) inside the training hallr |
| 92 | Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator) |
| 93 | Supply of 36 watt 2'' X2'' LED Surface/RECESSED mounted indoor type Round/square LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w Lamp complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge MAKE: PANASONIC/PHILIPS/Halonix/CROMPTON/WIPRO/HAVELLS/LT Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender