Educational and Research Institute Boards / Undertakings / PSU Closing in 1 days TDR #58142525

Tender For Supply, Installation, Testing And Commission (Sitc) Of Passenger Lift Plus Shaft For Division Of Biotechnology Under (Capex) At Main C Us Shalimar, Skuast-K

Issued by Boards / Undertakings / PSU · Srinagar, Jammu and Kashmir
Tender Value
41.86 Lakhs
Estimated cost
Bid Submission
28 Oct 2026
1 days left
EMD
83720
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing And Commission (Sitc) Of Passenger Lift Plus Shaft For Division Of Biotechnology Under (Capex) At Main C Us Shalimar, Skuast-K

BOQ

Name of Work:- Supply, Installation, Testing and Commission (SITC) of Passenger Lift Plus Shaft for Division of Biotechnology Under (CAPEX) at Main C us Shalimar, SKUAST-K
Sl. No. Item Description
1Passenger Lift with the following Specifications as per IS:-14665 (2000) along with AMC of 3 years.capacity passenger ,Machine room less (MRL) General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required :-
2Supply, Installation, Testing & Commissioning of 8 Passenger (G+2). The lift shall be suitable for 8 passengers of standard design having speed of 1.0 m/s serving from ground to 3rd floor i.e. 04 stops and 04 landings. The elevator shall be of state of art technology, energy efficient drive and all its components/ accessories shall conform to relevant IS standards.• (The Defect Liability Period (DLP) of the equipment shall be 01 years with 3 years of CMC post DLP)• Machine – Gearless machine located in the shaft on the top of guiderails• Power Supply – 400/415 V (3 Phase AC)• Control – Simple Collective Selective Control (VF regenerative drive)• Available Hoist way dimensions -1) 1550mm (W) x2000mm (D) • Car travel - 12 m. • Overhead - 4000mm • Pit depth - 1350mm. • Landing door – 2 panel automatic centre Door opening :One side only• Car design - Stainless steel in SS hairline finish. • Car floor - Granite• Handrail - round handrail in stainless steel finish provided on rear wall of car.• Alarm button in car operating panel with battery back-up.• Automatic operation for car fan. • Anti-nuisance (empty car)
3• Anti-nuisance (car call cancellation at direction reversal)• Blower fan in car for ventilation • Braille on push buttons• Door open and door close buttons in car operating panel. • Door closing retries• Door nudging • Emergency light • Full load by-pass • Infra–red screen for car door• Intercom Provision With Instrument • Motor overheat protection.• Overload function with audio-visuals indication in car operating panel. • Phase failure and phase reversal protection.• Automatic rescue device in case of power failure. • Attendant control.Car arrival chime on car top/voice synthesizer.• LCD dot matrix scrolling display in car operating panel. • LCD matrix scrolling display in landing operating panel on all floors.• Fireman control. •Fireman emergency return
4STOPS: 3 Stops With (all opening on the same side) Drive :Microprocessor Based V3F Drive.Machine : P M Gearless (Located in shaft on top of guide rails)Car Finish :Rear Mid Panel = SS Honey Comb Rear Corner Panels = SS Honey Comb Side Mid Panels = SS Honey Comb Side Corner Panels = SS Honey Comb Front Panels = SS Honey Comb ,opening door in stainless steel SS hairline finish.False Ceiling Finish: SS Mirror FinishHand Rail :Stainless Steel Hair Line Finish Handrails on rear car panel.Ventilation:Cross flow fan.Flooring:Granite Flooring /anti skid /equivalent.Door Operator: DC Door Operator / Telescopic .
5Standard Features :(i) Speed-1.0- 1.5 MPS (ii)Floors-3(G+2) (iii) Travel-17 metres(approx) (iv) Stops & opening : 3 stops and 3 openings (v) Controller: A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. (vii) Operation: Microprocessor based single automatic push button/simplex selective collective/ duplex collective selective with/without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors:- (a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). (b) Landing doors: stainless steel scratch proof . (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.
6(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing 112 DELHI SCHEDULE OF RATES (E&M)-2025 doors 2 hours Fire rated, Overload detection and protection, Overs peed Governer, Dot Matrix LED D & P Indicators In Car &Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi)An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided.
7Anti-nuisance Car Call ProtectionControl System :- Simplex automatic operation Overload Device NudgingFloor Annoucement Syatem with Music Emergency Firemen’s Service Emergency Car Light UnitInfrared Curtain Door ProtectionFull Car Operating Panel 8 Press & Speak Phone Door Time ProtectionEmergency Alarm ButtonExtra Door Time of Lobby & Parking Door Open/Close ButtonAutomatic Rescue Device with Dry Maintenance Free Batteries Auto Fan Cut OffProvision of CCTV CameraFire Rating of Landing Doors for 2 Hours Floor Annuciator with MusicProvision of 3 way intercom with instrument. Indicators in Car and Landings
8Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
9Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
10S/L of 4 X 16 sq. mm + 2 X 6 sq. mm earth wire and termination works etc in PVC conduit
11S/I of MCBTPN 63A TPN with enclosure etc
12Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
13Group B
14S/I of LED bulk head 9 watt
15Supplying and fixing following way, SPN DB on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
168 way Double door
17Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
18Single Pole
1963 Amps MCB DP
20Fabrication, supply, installation, testing & commissioning of outdoor type compartmentalized feeder pillar having front area not less than 0.60 Sqmtr (900 mm x 900 mm) and depth 45 Cm (NS) made out of 2mm thick CRCA sheet with tappered roof having separate cable and bus bar alley, 1 door arrangement i/c locking arrangement, having 300 Amp four pole aluminium bus bar of full length with base frame made out of 50mmx50mmx6mm (thick) angle iron having 80cm legs for erection in ground with construction of cement concrete suitable foundation size complete with connections and interconnections with copper conductor PVC insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. Providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd.
21INCOMER/OutgoingThermal Magnetic Based MCCB 100 Amps FP Icu=Ics=100% with Breaking Capacity 18-36 KA (01 Nos)S/I of Onload Changeover , Panel Mounted Standard Make 100 Amp SPN , RCCB 100A 100 mA , 1 phase Preventer , Voltage Monitoring Relay System DIgital Indicating Lamps RYB (1 Set)Voltmeter-0-500 Volts(1 Nos)Ammeter(0-150 A)(1 Nos)Selector Switch (2 Nos)Current Transformer 100/5 A 10 VA Burden, Class-1(1 sets)Aluminium Busbar 300 Amps FP E-91 E Grade Electrolytic AluminiumDP MCB 32 A(01Nos) Gland Plates to be 3.0 mm Thick.
22EATON/APC/Legrand or Equivalent ABB make 20KVA/384V On-Line UPS model 93E Tower type with 3 phase input and 3 phase output , built in OVCD, 1.0 pf, VFI technology complete with 32 nos. EnerRocket make 12V/42AH SMF batteries to provide back up time of 30 minutes ,MS battery rack, battery interlinks and Built in ReGEN kit for lift operation.
23Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
24Providing and fixing of Heating points for lift using 4 sq.mmPVC insulated copper wire through 1” 2mm PVC conduit/1” PVC casing capping and providing and fixing of 6/16 Amp. of Modular Switch/socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire t as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all as pects
25Wiring for circuit (lift)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required )Note : Rates of Suitable PVC conduit included in above description for the follwing items of make 4 X 10 sq. mm + 1 X 10 sq. mm earth wire
26Supply, laying, fixing of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade.i/c end terminations, clamping as required35sq mm 3.5 C
27Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links 125 Amp 36KA 4 pole
28Supplying, fixing of MCCB MS door type Enclosure suitable for 125 Amp 4 P MCCB
29Providing, fixing, testing and Commissioning of TPN 63A/ 63A Automatic ChangeOver 415 Volts of reputed make as per requirement
30Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6fine sand)
31Extra for brick work in: Square or rectangular pillars
32Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
33Marble work gang saw cut (polished and machine cut) of thickness 16 mm for wall lining (veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 (1ce ment: 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). (Area of slab over 0.5 sqm)
34Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:
35Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
36Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
37Centering and shuttering including strutting, propping etc. and removal of form for
38Foundations, footings, bases of columns etc. for mass concrete.
39Columns, pillars, piers, abutments, posts and struts.
40Lintel, beams, plinth beams, girders, bressumers and cantilevers
41Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing inCement mortar 1:6 ( 1 cement : 6 coarse sand)
42Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\"rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
4315mm Cement plaster on the rough side of single or half brick wall of mix1 : 6 ( 1 cement : 6 fine sand)
44Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded
45Providing and fixing Track deck CRIL make or equivalent H.I. rib profiled sheets 1000 to 1020 mm cover width 28-35 mm high crests at 250 to 255 mm T.C.T(total coated thickness) high tensile S.M.P Galvalume steel. The sheets shall have wide panes with 3 no stiffing ribs, effective water shedding and special male/female ends with full return legs on side Lapps for purlins support and anti-capillary flute inside Lapp. The sheets shall have a hot dip metallic coated of zinc and aluminum (150 gms /sm) zinc/aluminum coating mass total on both sides AZ-150 as IS -1397 ,550 MPA yield stress. Providing silicon modified polyester coating of approved colour of total thickness of 35 micron comprising 20 micron exterior coat of S.M.P over 5 micron polyester back coat over 5 micron primer coats on both surfaces including side and end Lapp and using 8mm Galvalume hex self-drilling fastener on each crest of sheet for connection with purlins and seam bolts at 300mm centers on all sides and end Lapps etc (.measured for unit of laid area) (0.50 mm thickness )
46Providing and laying of hand packed stone soling (size 100mm-150 mm), before laying of mud mat, compacted, consolidated, rammed and filling the voids with fine sand - all complete incl carriage upto site of work with all head loads
47Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements on lift wall with hinges/catchers etc as per sie requirement.
48Note:-The rates quoted are inclusive of all carriages of materials (Mechanical/Manual) from source to site work and all extra charges including dewatering if any during the execution of work complete in all respects. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58142525
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 41.86 Lakhs
LAST DATE 28-10-2026
Authority
Authority Name Sher-E-Kashmir University Of Agricultural Sciences & Technology
Work Description Tender for Supply, Installation, Testing And Commission (Sitc) Of Passenger Lift Plus Shaft For Division Of Biotechnology Under (Capex) At Main C Us Shalimar, Skuast-K
Basic Detail
Tender No E-NIT-67 of 2026-27
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 21 Oct 2026
Submission Date 28 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value 41.86 Lakhs
Tender Fee 2000
EMD 83720
Exemption Not Available
Document List
BOQ_1114367.xls
fe361f9f-9cd3-4bc3-aa89-7be7bf494a29.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1114367.xls

html

fe361f9f-9cd3-4bc3-aa89-7be7bf494a29.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender