Drinking Water Supply and Sanitation Government Departments Closing in 4 days TDR #58142483

Tender For Water Supply Scheme Pgims Rohtak - (Dnit) For The Strengthening Of The Existing 19.50 Mld Stp At Pgims Rohtak Supply, Installation, Testing, And Commissioning Of Required Instrumentation And Associated Electrical And Mechanical Equipment

Issued by Government Departments · Rohtak, Haryana
Tender Value
83.62 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
4 days left
EMD
1.67 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rohtak → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Water Supply Scheme Pgims Rohtak - (Dnit) For The Strengthening Of The Existing 19.50 Mld Stp At Pgims Rohtak Supply, Installation, Testing, And Commissioning Of Required Instrumentation And Associated Electrical And Mechanical Equipment

BOQ

Name of Work:- Water supply scheme PGIMS ROHTAK – (DNIT) for the strengthening of the existing 19.50 MLD STP at PGIMS Rohtak `Supply, installation, testing, and commissioning of required instrumentation and associated electrical and mechanical equipment`
Sl. No. Item Description
1Motorised Air valve Stainless Steel SAV 0.75 KW load 150 mm for both SBR no.1 and 2 blower selector zone of secondary treatment unit
2Polyelectrolyte Dosing pumps for 0.75 Kw motor pressure 7.0 kg/cm2, flow 450 LPH complete including Polyelectrolyte Dosing tank agitators with motor complete in all respect.
3Supply , Installing , testing commissioning , testing 6 CCTV Cameras within 96 hours of signing the agreement along with 120 days recording (DVR), 48 inch LED Screen, 16 Channel DVR at STP and MPS Site with connectors, cables, poles and power supply with online real-time output facility. PTZ speed dome 360 degree 50X zoom camera, CP Plus Internet Protocol minimum 5 MP WDR, Night vision color mode, IR range up to 150 m. CCTV Cameras should be installed and commissioned before starting of the work.Make: Sony / Canon / Panasonic / Samsung` ( STPs and MPS ) 1 Nos. PTU , 2 NO. SBR , 1 No. CCT, 1 No. ST and 1 No. Main gate.
4Supply installation, testing and commissioning of Laboratory Refrigerators:- • Storage Temperature: 2-8”C, Vertical Shelves at least 6 for storage of samples, Storage Capacity 500 Litres along with in-built digital temperature controller (company fitted). • Door for restricted accessibility. Castor wheels for easy mobility. Toughened glass door. • Enabled digital temperature controller to check and maintain inside temperature. • NABL calibration certificate.1 year warranty as desired by concerned lab Make : Cellfrost, Haier, Whirpoool`
5Desktop Computer Set:- Supply, installation, testing and commissioning of Desktop Computer Set comprising branded CPU and LED Monitor with preloaded operating system and necessary accessories. The desktop shall have minimum Intel Core i5 (12th Gen or latest equivalent) processor, 16 GB DDR4 RAM, 512 GB NVMe SSD, integrated graphics, Gigabit LAN, Wi-Fi, Bluetooth, USB ports, HDMI/DisplayPort, audio ports, USB keyboard and optical mouse. The monitor shall be 21.5-inch Full HD (1920 × 1080) LED display with HDMI/VGA connectivity. The system shall be supplied with Windows 11 Professional (64-bit), all required drivers, power cords, and accessories, complete with 3-year onsite OEM warranty, including installation, testing, commissioning, and making the system fully operational.( PLC Scada roorm)
6Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC and SCADA and comprising of all accessories not limited to the following: DI :- 70 No. DO :- 40 No. AI :- 26 No. AO :- 14 No. MCB 16A DP :-2 No. MCB 6A DP :- 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC :- 1 No. Selector Switch (Auto/Manual) and Local / Remote:- 2 No. Control Relays :- 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter :- 1 No. Control Transformer 200VA :- 1 No. Emergency STOP Push Button :- 1 No. Panel Cooling Fan and Filter :- 2 No. Panel Light with Door Switch, 7W :- 1 No. Control Indication Lamp for 24VDC, 220VAC :- 3 No. Push Button :- 3 No. Power Wiring plus Control Wiring plus Control TB/ Fuse 2A,TB etc :- 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. :- 1 Lot UTILITY SOCKET 16A, 3 PIN :- 2 No. HMI Display 10 Inch, Colour :-1 No. Isolators Dual Output, 24VDC :- 1 Lot`( In PLC Room)
7DO SENSOR AND ANALYZER: Supply Installation Testing Commissioning of DO analyzer With sample temperature 0-80 degree C, Measuring range 0-20mg/L, Measuring Mode continuous, Screen Colour TFT LCD 480 x 272 pixels with LED backlight, communication RS232, MODBUS or HTTP/Web interface (windows with IE9/10/11, Android with Opera, Apple I-phone with safari). RS485 port for MODBUS communication RS485 port for digital probes (DO). ( At SBR basin decentor)
8RADAR LEVEL TRANSMITTER FOR DECANTER: Supply, installation, testing, and commissioning of a non-contact, high-frequency Frequency Modulated Continuous Wave (FMCW) Radar Level Transmitter. The instrument shall track the dynamic mechanical descent, tilt trajectory, and absolute positioning of the moving decanter arm within the Sequencing Batch Reactor (SBR) basins.Operating Principle: 80 GHz FMCW Radar, Measuring Range: 0 to 15 metres minimum. Measurement Accuracy: = ±2 mm across the entire calibrated span, Beam Angle: Maximum 8 degrees, Material of Construction (Enclosure): Stainless Steel 316, Material of Construction (Sensor Face / Wetted Parts): PVDF Copolymer or PTFE, hermetically sealed, Power Supply: 24V DC, 2-wire loop-powered., Analog Output: 4 to 20 mA DC with superimposed HART 7.0 digital communication protocol, Enclosure Rating: IP66 / IP68 (NEMA 4X / 6P) submersible rating, Process Temperature: -40°C to plus 80°C, Approved Make: Siemens, SITRANS LR110 or approved equivalent matching all structural parameters.
9WATER LEVEL TRANSMITTER ( ULTRASONIC TYPE): Supply, installation, testing, and commissioning of a non-contact, loop-powered Ultrasonic Level Transmitter. The instrument shall monitor continuous liquid level fluctuations inside the SBR basins to drive automated process phase transitions (Fill, Aerate, Settle, Decant) via the centralized plant PLC/SCADA system. Operating Principle: Non-contact Ultrasonic Time-of-Flight. Measuring Range: 0 to 12 metres minimum. Measurement Accuracy: = ±0.25% of the programmed span or 6 mm (whichever is greater). Material of Construction (Enclosure): Polycarbonate with a transparent lid over the local Human-Machine Interface (HMI) display. Material of Construction (Transducer Face). 100% PVDF Copolymer or ETFE to withstand corrosive H2S and domestic chemical exposure. Power Supply: 24V DC, 2-wire loop-powered loop. Analog Output: 4 to 20 mA DC with HART digital communication protocol. Enclosure Rating: Electronics Enclosure: IP66/IP67 (NEMA 4X): Transducer Element: IP68 submersible. Local Display: Multi-parameter graphical LCD display showing level, space, distance, and echo profile curves
10Air Blower :- Supply, Installation, Testing and commissioning of Rotary Twin Lobe type Air Blower having capacity 4100 M³/Hr along with suitable size main header MS pipe epoxy coated, electric motor KW/rpm 132/1000, blower rpm 995, pressure 6500 mmwc, acoustic, VFD panels including Electro-mechanical actuator with IP-68 protection integrated with central PLC/SCADA, suitable size Power, control/signal cables along with tray and all other civil, electrical, mechanical and instrumentation work complete in all respect as per the specifications of DNIT ( Replacement according existing specification)
11Tubular Type Diffuser :- Supply, installation, testing and commissioning of Tubular Type Diffuser EPDM type 63 mm dia x 1000 mm length for fine air bubbles manufactured from high-quality extruded aluminium, powder-coated in standard white finish, complete with adjustable air control damper, mounting frame, fixing accessories, screws, nuts, and hardware. The diffuser shall be suitable for supply/return air applications in HVAC systems and designed to provide uniform air distribution with low noise and pressure drop. The item includes cutting, fixing, alignment, sealing, connection to ductwork, testing, balancing, and commissioning for both SBR-1 and SBR-2 complete in all respects..
12Providing and fixing, testing and commissioning stainless steel expansion joint at existing Air Blower, Capacity 4100 m³/hr, Pressure 6500 mmWC, complete
13Motorised Air valve Stainless Steel PAV 0.75 KW load 450 mm for both SBR no.1 and 2 blower main pipe
14Centrifuge Feed Pump : Providing and installing centrifuges as per design 20 m head, 5HP, capacity 15m3/hr, pump speed 325 including, feed pump complete in all respect as per the specifications of DNIT.
15Chlorine booster pump : Chlorine booster pump 2m3/hr @ 50 m head for chlorination unit complete in all respect specification .
16Sludge thickner feed pump : Sludge thickner feed pump 12m3/hr @ 8 m head 3.73 kw load between sludge thickner tank complete in all respect specification
17Air Conditioner:- Supply, installation, testing and commissioning of 1.50 tonne split-type air conditioner suitable for laboratory application, complete with indoor evaporator unit, outdoor condensing unit, inverter compressor, copper refrigerant piping, insulation, drain piping, electrical wiring, control remote, mounting brackets, vibration pads, and all accessories. The system shall be energy efficient with suitable cooling capacity for continuous laboratory operation. The item includes installation, vacuuming, refrigerant charging, testing, trial run and commissioning for laboratory and Scada/PLC panel room complete in all respects.
18RAS pump set for SBR no.2 : Removal of existing RAS pump set 12.50 HP including all components. Design, supply, Installation, Testing and commissioning of subersible non clog centrifugal pump of 160 m3/hr @ 6m head 9.50 kw motor for 19.50 MLD average flow with peak factor along with all components, guide pipe, chain pulley as per existing site conditions including Electro-mechanical actuator non intrusive type with IP-68 protection with manual override wheel integrated with central PLC/SCADA, suitable size Power, control/signal cables along with tray and all other civil, electrical, mechanical and instrumentation work complete in all respect as per the specifications.
19HSR Itmes Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58142483
AUTHORITY Government Departments
TENDER VALUE 83.62 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Water Supply Scheme Pgims Rohtak - (Dnit) For The Strengthening Of The Existing 19.50 Mld Stp At Pgims Rohtak Supply, Installation, Testing, And Commissioning Of Required Instrumentation And Associated Electrical And Mechanical Equipment
Basic Detail
Tender No 2026C83240AA 1E5C 45B0 9D6C E7470911E700576PUH
Bidding Type Tender
Location
City Rohtak
State Haryana
Key Dates
Publish Date 21 Oct 2026
Submission Date 02 Nov 2026
Open Date 02 Nov 2026
Finance
Tender Value 83.62 Lakhs
Tender Fee 5000
EMD 1.67 Lakhs
Exemption Available
Document List
BOQ_635614.xls
ee3b76ad-aae6-4e32-a097-de8a27219b82.html
TA4BKGZ179622.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_635614.xls

html

ee3b76ad-aae6-4e32-a097-de8a27219b82.html

pdf

TA4BKGZ179622.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender