Tender For Construction Of metallic and tarring Garage At Gc Crpf Raipur, Chhattisgarh.
Tender Overview
Project Description
Tender for Construction Of metallic and tarring Garage At Gc Crpf Raipur, Chhattisgarh.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-Nov-2026 | Date Corrigendum | Date | 12-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Consultancy services for Construction of MT Park including 02 nos washing platform, MT Office/Store & Toilet/Washroom at GC CRPF Raipur, Chhattisgarh. # Amount for Consultancy services is restricted upto 2,00,000/- (Two lakhs ) only1. Soil Investigation : Report available (attached with NIT)2. Laboratory Testing & Report (attached with NIT)3. Design of MT Parka) Preparation of Architectural Drawings as per scope of the sanctioned work including layouts for electric supply, sewage disposal, water supply, surface drainage and any other architectural/functional feature required to make the MT Park function efficiently. The MT Park will be steel structure and workshop building shall be of RCC.b) Most economic & safe structural design based on geotechnical investigation report and architectural drawings keeping in view the latest and relevant Indian Standard Codes and sound Engineering practice.c) Preparation of structural drawings based on the design, getting them vetted by IIT/NIT/Govt. Engineering College and approved by DIG (Engineer) CRPF.d) All calculations, analysis results, design calculation/input-output data shall be handed over alognwith structural drawings & design report to DIG (Engineer) CRPF. e) Design of RCC road to be done considering upto 30 tons capacity heavy vehicle movement. 4. Deliverablesa) Architectural drawings.b) Structural Design report alongwith structural drawings duly vetted by IIT/NIT/Govt. Engineering College.c) Detailed drawings for construction of all internal and external utility services (Civil & Electrical) as required for the project 05 (six) set of hard copies of all drawings and soft copies in PDF & CAD in Pen Drive shall be provided without any additional cost. For any additional set of drawings will be provided at the cost of Rs. 50/- per drawing.06 Structure design shall be prepared as per Lay Out Plan (LOP and Truss Design attached for ready reference) |
| 2 | EARTH WORKEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 4 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil. Pipes, cables etc, not exceeding 80 mm dia. |
| 5 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 6 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil. Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif. |
| 8 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 9 | CEMENT CONCRETE (CAST IN SITU)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for :: Foundations, footings, bases for columns |
| 12 | Making plinth protection 50 mm thick of cement concrete 1:3:6(1 cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Aggregate (RA) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 13 | REINFORCED CEMENT CONCRETEProviding and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ) |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for : Weather shed, Chajjas, corbels etc., including edges |
| 22 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 23 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 24 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 25 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 26 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 27 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 28 | MASONRY WORKBrick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:4(1 cement :4 coarse sand) |
| 29 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:4(1 cement :4 coarse sand) |
| 30 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level : Cement mortar 1:4(1 cement :4 coarse sand) |
| 31 | CLADDING WORKProviding and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 32 | WOOD AND P. V. C. WORKProviding and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :: 35 mm thick including ISI marked Stainless Steel butthinges with necessary screws |
| 33 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 34 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete :: Twin rubber stopper |
| 35 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds :: Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body :: Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2metre). |
| 36 | STEEL WORKProviding and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer :: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 37 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 38 | Providing and fixing M.S. fan clamp type I or ll of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 39 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 40 | Providing and fixing bolts including nuts and washers complete |
| 41 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. railings, In gratings, frames, guard bar, ladder, brackets, gates and similar works |
| 42 | FLOORING62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 43 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 44 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 45 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 46 | Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre . |
| 47 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 48 | Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily :: Glazed Vitrified tiles Matt/Antiskid finish of size :: Size of Tile 600 x 600 mm |
| 49 | ROOFINGProviding and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 100 mm diameter |
| 50 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes :: 110 mm diameter |
| 51 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion :: Bend 87.5° :: 110 mm bend |
| 52 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. : Shoe (Plain) :: 110 mm Shoe |
| 53 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 54 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 55 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :: Ridges plain (500- 600mm) |
| 56 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :: Gutter (600 mm over all girth) |
| 57 | FINISHING12 mm cement plaster of mix: 1:4(1 cement: 4 coarse sand) |
| 58 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4(1 cement: 4 coarse sand) |
| 59 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) |
| 60 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 61 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 62 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 63 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats |
| 64 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. |
| 65 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 66 | ROAD WORKPreparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 67 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine |
| 68 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 69 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 70 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 71 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 72 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete |
| 73 | Providing and fixing soil, waste and vent pipes : 100 mm dia. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 74 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 75 | Providing and fixing plain bend of required degree. 100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 76 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe. 100 mm dia. SS 304 grade coupling with EPDM rubber gasket. |
| 77 | Providing and fixing trap of self-cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 78 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. |
| 79 | WATER SUPPLYProviding and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 20 mm dia nominal bore |
| 80 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore |
| 81 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50mm dia nominal bore |
| 82 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
| 83 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore |
| 84 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore |
| 85 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 86 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 20 mm nominal bore |
| 87 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal bore |
| 88 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 50 mm nominal bore |
| 89 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 90 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 91 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :: 15 mm nominal bore |
| 92 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 93 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 20 mm nominal bore, 120 mm long, weighing not less than 198 gms |
| 94 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length |
| 95 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 20 mm nominal bore, weighing not less than 40 gms |
| 96 | DRAINAGEProviding, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 300 mm diameter |
| 97 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 300 mm diameter S.W. pipe |
| 98 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 99 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 100 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. For pipes 100 to 250 mm diameter |
| 101 | New technologiesProviding and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made :: Frame size 45 x 70 mm |
| 102 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made :: Frame size 65 x 125 mm |
| 103 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) : 30 mm thick |
| 104 | ITEM BASED ON MARKET RATEProviding and fixing stainless steel sliding door bolts (SS-304) of approved brand with nuts and screws etc. complete: 250x16 mm |
| 105 | Providing and fixing stainless steel tower bolts (Grade SS-304) of approved brand with necessary screws etc. complete: : 250x10 mm |
| 106 | Providing and fixing stainless steel tower bolts (Grade SS-304) of approved brand with necessary screws etc. complete: : 150x10 mm |
| 107 | Providing and fixing Stainless Steel handles (Grade SS-304) of approved quality & make with necessary screws etc all complete. : 150 mm |
| 108 | Providing and fixing white vitreous china flat back half stall urinal of size 560x320x345 mm, with fittings, standard size C.P, spreaders with unions and clamps (all in C.P. brass) with waste couplings in C.P. brass as per IS:2556, CP brass connection pipe, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal |
| 109 | ELECTRIC {SH-I ( Wiring)}Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required :: Group C |
| 110 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required : Group C |
| 111 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 112 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 113 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. :: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
| 114 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. ::4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire |
| 115 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. :: 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 116 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. :: 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 117 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required : 20 mm dia |
| 118 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required : 25 mm dia |
| 119 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. : 1 Pair |
| 120 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. : 2 Pair |
| 121 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required : Telephone socket outlet |
| 122 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required : 1 or 2 Module (75 mmX75 mm) |
| 123 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 124 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 125 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 126 | SH-II (Fan and Fitting)Supplying Installation testing and commissioning of follwing size heavy duty exhaust fan along with MS louvers & shutter in the existing opening, including making good the damage, connection with 3 x 1.5 Sq. mm PVC insulated FRLS copper conductor cable i/c testing, commissioning etc. as required. : 450 mm sweep heavy duty 1400 RPM single phase |
| 127 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 128 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 129 | Supply, Installation, Testing and Commissioning of surface/wall mounted 4 feet LED Batten with a system lumen output not less than 2000 lumens and a minimum system effiency of 110 lumen/watt. The luminaire is made of aluminium housing and shall have diffused optics. 6500 K,P.F > 0.95, CRI > 70 i/c connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as reqd. |
| 130 | Supply and fixing of Recessed/ surface Mounting Full glow LED 2' x2' approx fitting with CRCA / Aluminium Housing with Powder coated PMMA Diffuser, Lumen output minimum 3600, Minimum System efficacy > 100 Lm/W, colour temprature > 5700K, CRI >80, Life >50,000 Hrs @ L70 as per LM 70 and testing as per LM 80 complete with all accessories etc. directly on ceiling/ wall including connections with 3 x 1.5 sqmm FRLS PVC insulated copper conductor single core cable and earthing etc. as required. |
| 131 | Supplying & Installation of 250 mm plastic body fresh air fan, Min. RPM 1200, Max. power consumption 45watt. (ISI marked) i/c making aluminum frame for installation of fresh air fan, i/c connection, testing & commissioning etc. as reqd. |
| 132 | SH-III (MCB's & DB's)Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. : Single Pole |
| 133 | Providing and fixing following rating and breaking capacity, with adjustable thermal setting and pole MCB/MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (ICs = ICU= 100%) :: 100 Amp, 30KA, FPMCCB |
| 134 | Providing and fixing following rating and breaking capacity, with adjustable thermal setting and pole MCB/MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (ICs = ICU= 100%) :: 63A 16KA 4P MCCB |
| 135 | Providing and fixing following rating and breaking capacity, with adjustable thermal setting and pole MCB/MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (ICs = ICU= 100%) :: 40A 4P MCCB |
| 136 | Providing and fixing following rating and breaking capacity, with adjustable thermal setting and pole MCB/MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (ICs = ICU= 100%) :: 63A DP MCB |
| 137 | Providing and fixing following rating and breaking capacity, with adjustable thermal setting and pole MCB/MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (ICs = ICU= 100%) :: 40A DP MCB |
| 138 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. : 4 way Double door |
| 139 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 4 way (4 + 12), Double door |
| 140 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) :: 12 way , Double door |
| 141 | Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 142 | Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. :: For 4 way, Double door TPN MCB DB |
| 143 | Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. : For 10 way, Double door SPN MCB DB |
| 144 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 145 | SH-IV (Service Connection)Supply of following sizes of Aluminium LT cables, XLPE |insulated, cores laid up, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cables with stranded |Aluminium conductor suitable for rated voltage of 1.1 KV grade, ISI marked conforning to IS:7098(Part-I)/1988 with latest amendements etc. as required. Note:- (1)The actual required quantity shall be ascertained by the contractor at his own level before supply them at site. Department will not be responsible for cable remains unutilised and any loss, if any suffered on this account.(2) Secured Advance, if paid, will be recovered for material remained unutilised. Contractor shall have no claim whatsoever on this account :: 3.5 x 185 sqmm |
| 146 | Supply of following sizes of Aluminium LT cables, XLPE |insulated, cores laid up, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cables with stranded |Aluminium conductor suitable for rated voltage of 1.1 KV grade, ISI marked conforning to IS:7098(Part-I)/1988 with latest amendements etc. as required. Note:- (1)The actual required quantity shall be ascertained by the contractor at his own level before supply them at site. Department will not be responsible for cable remains unutilised and any loss, if any suffered on this account.(2) Secured Advance, if paid, will be recovered for material remained unutilised. Contractor shall have no claim whatsoever on this account : 3.5 x 120 sqmm |
| 147 | Supply of following sizes of Aluminium LT cables, XLPE |insulated, cores laid up, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cables with stranded |Aluminium conductor suitable for rated voltage of 1.1 KV grade, ISI marked conforning to IS:7098(Part-I)/1988 with latest amendements etc. as required. Note:- (1)The actual required quantity shall be ascertained by the contractor at his own level before supply them at site. Department will not be responsible for cable remains unutilised and any loss, if any suffered on this account.(2) Secured Advance, if paid, will be recovered for material remained unutilised. Contractor shall have no claim whatsoever on this account : 3.5 x 70 sqmm |
| 148 | Supply of following sizes of Aluminium LT cables, XLPE |insulated, cores laid up, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cables with stranded |Aluminium conductor suitable for rated voltage of 1.1 KV grade, ISI marked conforning to IS:7098(Part-I)/1988 with latest amendements etc. as required. Note:- (1)The actual required quantity shall be ascertained by the contractor at his own level before supply them at site. Department will not be responsible for cable remains unutilised and any loss, if any suffered on this account.(2) Secured Advance, if paid, will be recovered for material remained unutilised. Contractor shall have no claim whatsoever on this account :: 3.5 X 50 sqmm |
| 149 | Supply of following sizes of Aluminium LT cables, XLPE |insulated, cores laid up, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cables with stranded |Aluminium conductor suitable for rated voltage of 1.1 KV grade, ISI marked conforning to IS:7098(Part-I)/1988 with latest amendements etc. as required. Note:- (1)The actual required quantity shall be ascertained by the contractor at his own level before supply them at site. Department will not be responsible for cable remains unutilised and any loss, if any suffered on this account.(2) Secured Advance, if paid, will be recovered for material remained unutilised. Contractor shall have no claim whatsoever on this account : 3.5 X 25 sqmm |
| 150 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/DWC/METAL/ pipe as required : 3.5 x 185 sqmm |
| 151 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/DWC/METAL/ pipe as required :3.5 x 120 sqmm |
| 152 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/DWC/METAL/ pipe as required : 3.5 x 70 sqmm |
| 153 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/DWC/METAL/ pipe as required : 3.5 X 50 sqmm |
| 154 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/DWC/METAL/ pipe as required : 4 X 25 sqmm |
| 155 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonary open ductas reqd ; 3.5 x 185 sqmm |
| 156 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonary open ductas reqd : 3.5 x 120 sqmm |
| 157 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonary open ductas reqd ; 3.5 X 70 sqmm |
| 158 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonary open ductas reqd 3.5 x 50sqmm |
| 159 | Laying of one number insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonary open ductas reqd 4 X 25 sqmm |
| 160 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required ; 3.5 x 185 sqmm(57mm) |
| 161 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required :: 3½ X120 sq. mm (45mm) |
| 162 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required :: 3.5 x 70 sq. mm (38mm) |
| 163 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required :: 3½ X 50 sq. mm (35mm) |
| 164 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required : 4 X 25 sqmm (28mm) |
| 165 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc. in the existing trench, complete as required. : 120mm dia(OD-120mm &ID-103mm nominal) |
| 166 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required :: 120mm dia(OD-120mm &ID-103mm nominal) |
| 167 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required :: 90 mm dia ( OD-90 mm & ID-76 mm Nominal) |
| 168 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required :: 63 mm dia ( OD-63 mm & ID-51 mm Nominal) |
| 169 | Supplying, installation, Testing and commissioning of LED Street light fixture for road lighting. Optical system of high-quality temperature-resistant optical lens systems. Street light housing of die-cast aluminum, highly weather resistant. Luminaire luminous flux > 4200 lm, luminous efficiency of luminaire 120 lm/W. correlated colour temperature (CCT) 5700 K, general colour rendering index (CRI) > 70. Service life L70(tq 25 °C) = 50,000 h. IK05/0, P.F > 0.95, THD<10%, Input surge protection 10kV, Protection IP66, complete with connection, testing etc as reqd. (5 years warantee shall be submitted by contractor on OEM's letter head. |
| 170 | Supply and fixing of following sizes of hot dipped galvanised bracket made out of 48 mm dia pipe with a Canopy of 300 mm suitable for octogonal pole including painting with superior quality of primer and synthetic enamel paint two or more coats etc. as required. : Single arm bracket of 1000 mm long |
| 171 | SH-V (Earthing & lightning conductor)Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 172 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 173 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 174 | Jointing copper/ G.I. tape (with another copper/ G | tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 175 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontalrun) |
| 176 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 177 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 178 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 179 | SH - VI( fire extinguishers)Providing & Fixing of stored pressure of 6 Kg Fire Extinguisher ABC powder type (Mono Ammonium Phosphate Powder 90%) Magnetic Pressure Gauge having the facility to check at site, Discharge Time less than 9 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 21A, B Rating 55B as per BS EN-3 BIS 15683 marked, Can Construction : Deep drawn & CO2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60 MM, Helium Leak Detection Tested, Warranty etc. |
| 180 | Providing and fixing 4.5 Kg carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. |
| 181 | SH - VII (Panels)Fabrication, Supplying, Installation, Testing & commissioning of out door totally enclosed weather proof feeder pillar with slanting top of suitable size fabricated from 2mm thick CRCA sheet of depth not less then 300mm with base frame fabricated from 50 mm x 50mm x 5 mm angle iron suitable for 415/500 volts, 50 Hz, A..C. Supply with gland plate for cable entry, hinged front openable double leaf door with locking arrangement including suitable rating 4 strip Aluminium. bus bar, danger notice plate,indicating lamps, making connection/ interconnection, earthing arrangement, treated with 7 tank process, powder coated, painted with approved paint and shade including erection of feeder pillar on suitable cement concrete foundation 400 mm above ground level i/c writing of each outgoing switchgears etc as per direction of engineer-in-charge as reqd. (As per approved drawing).(Minimum area 3 sq.m) (As per approved drawing).(All MCCB's should have ICU=100% ICS) (Main Panel) :: Panel having 300 A AL Bus bars : 250 Amp 36 KA 4-Pole MCCB with Spreader link-1 Set : 100 Amp 30 KA 4-Pole MCCB with Spreader link- 4 sets : 125 Amp 36 KA 4-Pole MCCB with Spreader link-4 Set. : Multifunctional Meter - 1 No. |
| 182 | Fabrication, Supplying, Installation, Testing & commissioning of out door totally enclosed weather proof feeder pillar with slanting top of suitable size fabricated from 2mm thick CRCA sheet of depth not less then 300mm with base frame fabricated from 50 mm x 50mm x 5 mm angle iron suitable for 415/500 volts, 50 Hz, A..C. Supply with gland plate for cable entry, hinged front openable double leaf door with locking arrangement including suitable rating 4 strip Aluminium. bus bar, danger notice plate,indicating lamps, making connection/ interconnection, earthing arrangement, treated with 7 tank process, powder coated, painted with approved paint and shade including erection of feeder pillar on suitable cement concrete foundation 400 mm above ground level i/c writing of each outgoing switchgears etc as per direction of engineer-in-charge as reqd. (As per approved drawing). (Minimum area 2 sq.m) (All MCCB's should have ICU=100% ICS) (Essential panel) :: Panel having 200 A AL Bus bars : 125 Amp 36 KA 4-Pole MCCB with Spreader link- 1 Set :: 63 Amp 16 KA 4-Pole MCCB with Spreader link-4 sets. : 100 Amp 30 KA 4-Pole MCCB with Spreader link-2 sets : Multifunctional Meter - 1 No. |
| 183 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres. |
| 184 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required : 100mm dia |
| 185 | Providing and laying in position cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender