Youth Affairs and Sports and Culture Government Departments Closing in 9 days TDR #58141721

Tender For Construction Of Stage And Changing Rooms At Chamerem Chodan Playground.

Issued by Government Departments · goa, Goa
Tender Value
62.56 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
9 days left
EMD
1.25 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Stage And Changing Rooms At Chamerem Chodan Playground.

BOQ

Name of Work:- Construction of stage and changing rooms at Chamerem Chodan playground.
Sl. No. Item Description
1Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. a)All kinds of soil
2Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
3Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a)All works upto plinth level
4Centering & shuttering including Strutting, Propping & removal of forms for : (a) (i) Foundations, Footings, Bases for columns
5Centering & shuttering including Strutting, Propping & removal of forms for : (b) (iii) Columns, Piers, Pillars, Abutments, Posts and struts (square rectangle polygon in plan)
6Centering & shuttering including Strutting, Propping & removal of forms for : (c) (iv) Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, bressumers and Lintels plinth beams not exceeding 1m in depth
7Centering & shuttering including Strutting, Propping & removal of forms for : (d) (xiii) Suspended floors, roofs landings, shelves & their supports
8Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (1 cement: 1½ coarse sand:3 graded stone aggregate 20mm nominal size) (a) All works upto plinth level
9Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (1 cement: 1½ coarse sand:3 graded stone aggregate 20mm nominal size) (b) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level
10Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (1 cement: 1½ coarse sand:3 graded stone aggregate 20mm nominal size) (b)(c)in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level
11Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
12Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
13Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in all sizes in superstructure from floor I level upto floor V level.
14Half brick masonry in cement mortar 1:4 (1 cement : 4 coarse sand). With bricks of class designation 40 kg/sq.cm.(Upto floor V level)
1512mm cement plaster 1:4 (1 cement : 4 fine sand)
1618mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
17Welding by electric plant (using Ador or ES4B or Deh Secheron make electrodes only )
18Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
19Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
20Providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete (b) Light Shades
21Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete.
22Providing and fixing Kota stone tread tiles 35mm thick in single piece with rounded of nosing antiskid groove laid on and including 20mm (average ) thk bed of cement slurry including pointing with pigmented cement slurry to match the shade of the slab, cleaning etc. complete.
23Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in position (b) Second class Indian teak wood
24Providing and fixing flush door shutter of solid core melamine face three layered, prelaminated wood based particle board exterior grade having shade of choice on both sides (PTX) or having shade of choice on one side and balancing lamination on the other side (PLX) as per IS 3087 (1985) type I on the edge of Novopan or equivalent bonded with BWR/BWP synthetic resin with second class teak wood, lipping of section of size 12 mm x 30 mm flange and 18 mm x 10 mm web (18 mm deep) fixed into 18 x 10 mm groves of shutter with water resistant adhesive and fully threaded G.I. screws 50 mm not more than 450 mm centre to centre including anodized aluminum butt hinges with necessary screws etc. complete. (b) Natural teak on both faces: 2) 30 mm thick
25Providing FRP door shutters 35mm thick with frame size in clear opening of 0.75x2.10m hinges and screws complete.,
26Providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size.b) 40 x 3 mm flat iron hold fast, 15 cm long
27Providing & fixing chromium plated brass tower bolts (barrel type) with necessary screws complete. (c)150 x 10 mm
28Providing and fixing chromium plated brass handle with necessary screws etc. complete (b) 100 mm
29Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by screws.(a) Plain grill
30Providing and fixing anodized aluminum shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vole & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Fixed windows/ ventilators matching with 18 mm series shutters. (c)Figured glass
31Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section.(c)Figured glass
32Extra for powder coating with pure polyester powder of shade of required colour on the aluminum section
33Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
34Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
35Finishing fine with neeru over plaster
36Applying one coat of cement primer of approved brand and manufacture on wall surface.
37Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
38Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield, APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.
39Applying priming coat with ready mixed primer of approved brand and manufacture on wood work complete.
40Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for wood work of approved brand & manufacture in all shades on new work to give an even shade.
41Proving and fixing white vitreous china water closet squating (European type w.c. pan) with seat and lid, C.P. brass hinges and rubber buffers 10 lts. High level P.V.C.. flushing cistern (of approved make ) with fittings, rack bolts 32 mm diameter P.V.C. telescopic flush pipe with fit tings and clamps 25mm P.V.C.. over flow pipe with specials & mosquito proof coupling of approved municipal design and nylon. chain and pull complete, cutting and making good the walls ad floors where required. W.C. pan with white plastic seat and lid.
42Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 430 x 265 mm sizes respectively with pvc automatic flushing cistern with fittings, R.S. or C.I. brackets, standard size galvanised steel flush pipe and spreaders with brass unions & G.I. clamps complete, including painting of cister and fittings, cutting and making good the walls and floors where required.
43Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. Flat back wash basin size 630 x 450mm with a pair of 15 mm C.P. brass pillar taps.
44Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers.
45Providing & fixing CP brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws (b) 600 x 20 mm size
46Providing & fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778, having thermal stability for hot and cold water supply including all CPVC palin and brass threaded fittings including fixing the pipes with clamps at 1 m. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer – in – charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe) a)15 mm outer dia CPVC pipe
47Providing & fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778, having thermal stability for hot and cold water supply including all CPVC palin and brass threaded fittings including fixing the pipes with clamps at 1 m. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer – in – charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe) (b) 25 mm nominal bore.
48Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993
49Providing and fixing in position Angular stop cocks foe basin and urinals as instructed including testing, commissioning etc, complete.a) Florentine (FLR-5053N)
50Providing and fixing brass full way valve (heavy) duty with wheel of approved quality (c)25 mm nominal bore .
51Making soak pit. 2.5 m dia 3 m deep with 45x45 cm dry brick honey comb shaft and S.W. drain pipe 100 mm diameter, 1.8 m long complete filled with laterite stone aggregate 125 to 180 mm surrounded by laterite stone aggregate of 40 mm and down gauge as per standard design.
52Constructing soak pit 1.20m x 1.20m x1.20m filled with laterite stone aggregate 125 to 180 mm including S.W. drain pipe 100 mm diameter and 1.2m. long complete as per standard design. :
53Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door : (a) 110 mm dia
54Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: (a) 110 mm dia
55Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: (b) 75 mm dia
56Providing and placing on terrace roof of floor two (1st floor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996. (c)1000 lit. capacity
57Providing and laying jet black mirror polish granite flooring and dado over 20mm thick base of cement mortar 1:4 laid over and jointed with cement slurry including rubbing complete Granitic slab (jet black with mirror polish) 20 mm thick add q0% wastage 1.00
58Providing and fixing bright finished brass door latch with necessary screws etc complete (a) 300x 16 x 5 mm
59Providing and fixing bright finished brass tower bolts (barrel type) with screws etc. complete (a) 250 x 10 mm
60Providing and fixing chromium plated brass handle with necessary screws etc. complete (a) 015 mm nominal bore
61Providing and fixing brass stop cock (heavy) of approved quality : a) 15 mm nominal bore
62Providing and fixing P.V.C. connection pipe with brass unions 15 mm nominal bore: a)30 cm (12”) length .
63Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge.
64Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. a)Size 900 x 400 x 150 mm with steel reinforcement not less than 7 kg per unit -30 T capacity.
65Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. (b)Size 900 x 400 x 100 mm with steel reinforcement not less than 5.0 kgs per unit -12 T capacity
66Supplying and stacking of good earth at site including royalty and carriage upto 1 km. (earth measured in stacks will be reduced by 20% for payment).
67Spreading of sludge, dung manure or/and good earth in required thickness (cost of sludge, dung manure or/and good earth to be paid separately).
68Boring, Supply, Installation and Commissioning of Bore well to accommodate 150 mm ‘B’ class casing pipe upto 100 m depth including survey of availability of water, drilling of bore well with rotary /DTH type drilling of 300 mm dia bore gravel packing, cleaning development with mechanical air compressor for removing blockage and solid particles/minerals, providing, installation of 3 HP submersible pump with control panel board with approved make of switch gears and necessary fitting complete and as per direction and instruction to use additional fitting (inclusion of cost of material, labour etc.) by Engineer –in-charge. (Contractor to ensure yield of bore 40000lit per day and all necessary approval to be obtain by the contractor etc)
69Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. 40mm outer dia.
70Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group A -- with Cat A Modular Accessories
71Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
72Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm casing )
73Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm casing )
74Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (a) 5/6 A switch Cat A
75Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required ( c) (d) 3 pin 5/6 A socket outlet Cat A
76Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (b) (c) 15/16 A switch Cat A
77Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (d) (e) 6 pin 15/16 A socket outlet Cat A
78Supplying and fixing following size moduleas GI box alonwith modular base and cover plate for modulator switches in recess etc. as required (b) 4 Module ( 125 mm x 7 mm) Cat B
79Supplying and fixing following size moduleas GI box alonwith modular base and cover plate for modulator switches in recess etc. as required (c) 6 Module (200mm x 75 mm) Cat B
80Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required (a) Cat A
81Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (b) Cat A
82Supplying and fixing following way TPN sheet steel, single door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) (a) 4 way (4+12), double door, Horizontal type Cat A
83Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (a) SP, Cat A
84Supplying and fixing 63 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (e) TPN, Cat A
85Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty of make of make Kasper T NET/Philips/Lighting Technology/Wipro asdirected by Engineer Incharge.
86Supplying and erecting anodized aluminium mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V,surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block / wooded board with minimum 2 years warrantyof make Kasper T NET/Philips/Lighting Technology/Wipro as directed by Engineer Incharge.
87Supply and erecting of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. (a) Cat A
88Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe . g)watering arrangement(plumbing will be paid seperately). (a) In soily strata
89Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt).
90Supplying and laying 8 SWG copper wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required
91Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. (3) 4 Core 10 sq.mm
92Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required.
93Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warrantyy of make Kasper T NET/Philips/Lighting Technology/ Wipro asdirected by Engineer Incharge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58141721
AUTHORITY Government Departments
TENDER VALUE 62.56 Lakhs
LAST DATE 05-11-2026
Authority
Authority Name Sports Authority Of Goa
Work Description Tender for Construction Of Stage And Changing Rooms At Chamerem Chodan Playground.
Basic Detail
Tender No SAG/EE-ED/TECH/F08/26-27/2325
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 21 Oct 2026
Submission Date 05 Nov 2026
Open Date 06 Nov 2026
Finance
Tender Value 62.56 Lakhs
Tender Fee 10000
EMD 1.25 Lakhs
Exemption Not Available
Document List
b5b280fd-5f7c-4607-a895-8447bcced8e0.html
BOQ_32874.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Nov 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

b5b280fd-5f7c-4607-a895-8447bcced8e0.html

xls

BOQ_32874.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender