Tender For Maintenance Of Electrical Installation In Non Residential Building At Chandigarh (Providing / Replacement Of Defective Electrical Accessories /Led Fittings And Other Electrical Items In Chandigarh Secretariat Building, Sector-9, Chandigarh
Tender Overview
Project Description
Tender for Maintenance Of Electrical Installation In Non Residential Building At Chandigarh (Providing / Replacement Of Defective Electrical Accessories /Led Fittings And Other Electrical Items In Chandigarh Secretariat Building, Sector-9, Chandigarh).
BOQ
| Sl. No. | Item Description |
| 1 | DSR item No. 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 2 | 3 x 1.5 sq. mm |
| 3 | 3 x 2.5 sq. mm |
| 4 | DSR item No. 1.18 Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 5 | 2 Pair |
| 6 | DSR item No. 1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 7 | DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | 25 mm |
| 9 | DSR item No. 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | 5/6 A switch |
| 11 | 15/16 A switch |
| 12 | 3 pin 5/6 A socket outlet |
| 13 | 6 pin 15/16 A socket outlet |
| 14 | DSR item No. 1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 15 | 1 or 2 Module (75mmX75mm) |
| 16 | 3 Module (100mmX75mm) |
| 17 | 4 Module (125mmX75mm) |
| 18 | 6 Module (200mmX75mm) |
| 19 | DSR item No. 1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 20 | 1 or 2 Module |
| 21 | 3 Module |
| 22 | 4 Module |
| 23 | 6 Module |
| 24 | DSR item No. 1.40 Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS/HFFR PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 25 | DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Double pole |
| 27 | Triple pole and neutral |
| 28 | DSR item No. 15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 29 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 30 | DSR item No. 39.17 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C. Bending Radius: < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. |
| 31 | 1 Run of cable |
| 32 | DSR item No. 8.1 LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) (Please refer DNIT for complete specification of item no.12) |
| 33 | 12 -15 watt |
| 34 | DSR item No. 8.7 LED Panel light 2x2 ft.(System lumen efficacy ≥120 <135 lm/Watt) (Recess/ Surface type)(Please refer DNIT for complete specification of item no.13) |
| 35 | 36 watt |
| 36 | DSR item No. 8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).(Please refer DNIT for complete specification of item no.14) |
| 37 | 24-26 watt |
| 38 | DSR item No. 8.13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) (Please refer DNIT for complete specification of item no.15) |
| 39 | 45 watt |
| 40 | DSR item No. 8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).(Please refer DNIT for complete specification of item no.16) |
| 41 | 50 watt |
| 42 | 250 watt |
| 43 | Supply & erection ding dong type electronic bell including carriage, testing with suitable size of nuts / bolts and other petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The bell should be of Cona/ Anchor/ Havells make only. |
| 44 | Supply & erection of PVC Gang Box along with bell push switch of Anchor Panta/Havells/ SSK make only, including carriage, erection with suitable size of nuts/ bolts and other petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. |
| 45 | Supply, Erection, Testing and commissioning of the following items in existing LED fittings (Street light / flood light) installed on wall/ existing pole upto 16 Mtr. Long in place of burnt out / defective material with the help of hydraulic ladder / Crain with bucket which shall be arranged by the firm at his own cost. The job includes cost of making connection with suitable rating copper wire and petty material required to complete the job to the entire satisfaction of Engineer-in-charge. The job also includes the cost of dismantling the burnt out / defective material. |
| 46 | S/E of Electronic Driver suitable for existing 40w/45w/50w LED fittings. The Driver should be same make of existing fitting i.e. Philips /Wipro /Bajaj /Havells /Surya /Crompton/ Jaquar/ Lighting Technologies/ Trilux/ Panasonic make only. |
| 47 | Supply, Erection, Testing and commissioning of the following accessories after dismantling the burnt out/ defective accessories with the help of ladder if required which shall be arranged by the firm at his own cost. The job includes cost of making connections with suitable rating copper wire and petty material required to complete the job to the entire satisfaction of Engineer-in-charge. |
| 48 | S/E of Electronic Driver suitable for existing 2’x2’ LED panel type fitting. The driver should be same make of existing fitting i.e. Philips /Wipro /Bajaj / Havells /Crompton / Jaquar/ Surya/ Lighting Technologies/ Trilux/ Panasonic make only. |
| 49 | Supply & erection of size 600mm (24” sweep) wall mounted heavy duty double ball bearing Air Circulator fan. The Air Circulator fan should be of Havells make (Turbo Force)/ Usha make (Dominare)/ Bajaj make (Supereme Plus) / Crompton make (ACVORTEX 24WM) or its equivalent Almonard/ Orient make only, oscillating type with regulator complete with blades with sturdy close mess guard etc. The fan shall have 1440-RPM speed. The fan shall be noiseless. The cost includes connection with adjacent light points and fixed on the wall with steel fastner & nut / bolts and MS Plate etc. as required and other petty material reqd. to complete the job to the satisfaction of Engineer-in-charge of work. |
| 50 | Making of Haudi of following size for drawing of under ground cable etc constructed with bricks wall 4½” thick and plastered from the inner side with cement, sand, mixture 1:5. The RCC cover moulded in an angle frame of size 35mm x 35mm x 5mm should be provided above the Haudi which should rest on 40mm x 40mm x 5mm angle iron frame fixed on the upper portion of the Haudi. The cover should be provided with lifting arrangement. The rate includes all labour and material to complete the job with 1:4 CC mixture. |
| 51 | Size 2’ x 2’ x 2’ deep |
| 52 | Supply & erection of Wall Fan 400mm sweep oscillating type complete with blades with regulator. The fan should be of Havells (Swing)/ Usha (MAXX AIR)/ Orient (400mm Wall44)/ Crompton (WM Hiflo wave plus)/ Bajaj (Esteem Double String) make only. The wall fan should be provided with double string i.e. one no. controlling oscillating and one for speed. The cost including connection with adjacent light points with the help of suitable rating copper wire. |
| 53 | Labour charges for horizontal boring 1 Mtr. Below ground level for laying of DWC pipe including cost of 2 Nos. pit digging and refilling complete in all respects to entire satisfaction of the Engineer in Charge of the work. |
| 54 | Supply and laying of PVC Flexible pipe of following size of ISI marked only. The job includes the cost of petty material, coupler, check nuts etc. as required to the entire satisfaction of Engineer-in-charge. |
| 55 | 20 mm |
| 56 | 25 mm |
| 57 | Supply & erection of 10 watt. LED round shape spot light with adjustable type recess mounted with integral/ non integral driver to be installed on existing false ceiling with the help of rawl plug & screws etc. The fitting should be Philips /Wipro /Bajaj / Havells /Crompton / Jaquar/ Surya/ Lighting Technologies/ Trilux/ Panasonic make only. The job includes the cost of commissioning and making connection with 3x1.5 sq. mm copper wire from adjacent light point & other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender