Housing Urban and Rular Development Local Bodies Closing in 4 days TDR #58141692

Tender For Maintenance Of Electrical Installation In Non Residential Building At Chandigarh (Providing / Replacement Of Defective Electrical Accessories /Led Fittings And Other Electrical Items In Chandigarh Secretariat Building, Sector-9, Chandigarh

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
5.51 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
4 days left
EMD
11020
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance Of Electrical Installation In Non Residential Building At Chandigarh (Providing / Replacement Of Defective Electrical Accessories /Led Fittings And Other Electrical Items In Chandigarh Secretariat Building, Sector-9, Chandigarh).

BOQ

Name of Work:- MAINTENANCE OF ELECTRICAL INSTALLATION IN NON RESIDENTIAL BUILDING AT CHANDIGARH (PROVIDING / REPLACEMENT OF DEFECTIVE ELECTRICAL ACCESSORIES /LED FITTINGS AND OTHER ELECTRICAL ITEMS IN CHANDIGARH SECRETARIAT BUILDING, SECTOR-9, CHANDIGARH).
Sl. No. Item Description
1DSR item No. 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
23 x 1.5 sq. mm
33 x 2.5 sq. mm
4DSR item No. 1.18 Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
52 Pair
6DSR item No. 1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
7DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
825 mm
9DSR item No. 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
105/6 A switch
1115/16 A switch
123 pin 5/6 A socket outlet
136 pin 15/16 A socket outlet
14DSR item No. 1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
151 or 2 Module (75mmX75mm)
163 Module (100mmX75mm)
174 Module (125mmX75mm)
186 Module (200mmX75mm)
19DSR item No. 1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
201 or 2 Module
213 Module
224 Module
236 Module
24DSR item No. 1.40 Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS/HFFR PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.
25DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
26Double pole
27Triple pole and neutral
28DSR item No. 15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
2963 mm dia (OD-63 mm & ID-51 mm nominal)
30DSR item No. 39.17 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C. Bending Radius: < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required.
311 Run of cable
32DSR item No. 8.1 LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) (Please refer DNIT for complete specification of item no.12)
3312 -15 watt
34DSR item No. 8.7 LED Panel light 2x2 ft.(System lumen efficacy ≥120 <135 lm/Watt) (Recess/ Surface type)(Please refer DNIT for complete specification of item no.13)
3536 watt
36DSR item No. 8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).(Please refer DNIT for complete specification of item no.14)
3724-26 watt
38DSR item No. 8.13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) (Please refer DNIT for complete specification of item no.15)
3945 watt
40DSR item No. 8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).(Please refer DNIT for complete specification of item no.16)
4150 watt
42250 watt
43Supply & erection ding dong type electronic bell including carriage, testing with suitable size of nuts / bolts and other petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The bell should be of Cona/ Anchor/ Havells make only.
44Supply & erection of PVC Gang Box along with bell push switch of Anchor Panta/Havells/ SSK make only, including carriage, erection with suitable size of nuts/ bolts and other petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.
45Supply, Erection, Testing and commissioning of the following items in existing LED fittings (Street light / flood light) installed on wall/ existing pole upto 16 Mtr. Long in place of burnt out / defective material with the help of hydraulic ladder / Crain with bucket which shall be arranged by the firm at his own cost. The job includes cost of making connection with suitable rating copper wire and petty material required to complete the job to the entire satisfaction of Engineer-in-charge. The job also includes the cost of dismantling the burnt out / defective material.
46S/E of Electronic Driver suitable for existing 40w/45w/50w LED fittings. The Driver should be same make of existing fitting i.e. Philips /Wipro /Bajaj /Havells /Surya /Crompton/ Jaquar/ Lighting Technologies/ Trilux/ Panasonic make only.
47Supply, Erection, Testing and commissioning of the following accessories after dismantling the burnt out/ defective accessories with the help of ladder if required which shall be arranged by the firm at his own cost. The job includes cost of making connections with suitable rating copper wire and petty material required to complete the job to the entire satisfaction of Engineer-in-charge.
48S/E of Electronic Driver suitable for existing 2’x2’ LED panel type fitting. The driver should be same make of existing fitting i.e. Philips /Wipro /Bajaj / Havells /Crompton / Jaquar/ Surya/ Lighting Technologies/ Trilux/ Panasonic make only.
49Supply & erection of size 600mm (24” sweep) wall mounted heavy duty double ball bearing Air Circulator fan. The Air Circulator fan should be of Havells make (Turbo Force)/ Usha make (Dominare)/ Bajaj make (Supereme Plus) / Crompton make (ACVORTEX 24WM) or its equivalent Almonard/ Orient make only, oscillating type with regulator complete with blades with sturdy close mess guard etc. The fan shall have 1440-RPM speed. The fan shall be noiseless. The cost includes connection with adjacent light points and fixed on the wall with steel fastner & nut / bolts and MS Plate etc. as required and other petty material reqd. to complete the job to the satisfaction of Engineer-in-charge of work.
50Making of Haudi of following size for drawing of under ground cable etc constructed with bricks wall 4½” thick and plastered from the inner side with cement, sand, mixture 1:5. The RCC cover moulded in an angle frame of size 35mm x 35mm x 5mm should be provided above the Haudi which should rest on 40mm x 40mm x 5mm angle iron frame fixed on the upper portion of the Haudi. The cover should be provided with lifting arrangement. The rate includes all labour and material to complete the job with 1:4 CC mixture.
51Size 2’ x 2’ x 2’ deep
52Supply & erection of Wall Fan 400mm sweep oscillating type complete with blades with regulator. The fan should be of Havells (Swing)/ Usha (MAXX AIR)/ Orient (400mm Wall44)/ Crompton (WM Hiflo wave plus)/ Bajaj (Esteem Double String) make only. The wall fan should be provided with double string i.e. one no. controlling oscillating and one for speed. The cost including connection with adjacent light points with the help of suitable rating copper wire.
53Labour charges for horizontal boring 1 Mtr. Below ground level for laying of DWC pipe including cost of 2 Nos. pit digging and refilling complete in all respects to entire satisfaction of the Engineer in Charge of the work.
54Supply and laying of PVC Flexible pipe of following size of ISI marked only. The job includes the cost of petty material, coupler, check nuts etc. as required to the entire satisfaction of Engineer-in-charge.
5520 mm
5625 mm
57Supply & erection of 10 watt. LED round shape spot light with adjustable type recess mounted with integral/ non integral driver to be installed on existing false ceiling with the help of rawl plug & screws etc. The fitting should be Philips /Wipro /Bajaj / Havells /Crompton / Jaquar/ Surya/ Lighting Technologies/ Trilux/ Panasonic make only. The job includes the cost of commissioning and making connection with 3x1.5 sq. mm copper wire from adjacent light point & other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58141692
AUTHORITY Local Bodies
TENDER VALUE 5.51 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Maintenance Of Electrical Installation In Non Residential Building At Chandigarh (Providing / Replacement Of Defective Electrical Accessories /Led Fittings And Other Electrical Items In Chandigarh Secretariat Building, Sector-9, Chandigarh).
Basic Detail
Tender No E2/26/148
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 21 Oct 2026
Submission Date 02 Nov 2026
Open Date 02 Nov 2026
Finance
Tender Value 5.51 Lakhs
Tender Fee Ref. Documents
EMD 11020
Exemption Not Available
Document List
2ac6828f-050a-4d3d-bb1f-453eb6a20943.html
BOQ_118444.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

2ac6828f-050a-4d3d-bb1f-453eb6a20943.html

xls

BOQ_118444.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer