Tender For Improvement/Upgradation Of Guest House At Boys Hostel Bemina
Tender Value
1.13 Crore
Estimated cost
Bid Submission
03 Nov 2026
0 days left
EMD
2.27 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement/Upgradation Of Guest House At Boys Hostel Bemina
BOQ
| Sl. No. | Item Description |
| 1 | Civil Part |
| 2 | Dismantling/Chiping of tile work, marble, chips, flooring, Kota Stone etc in floors and roofs laid in cement mortar. For thickness of tiles 10 mm to 25 mm including disposal of unserviceable material as per directions of Engineer Incharge complete job; all inclusive. |
| 3 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 4 | 12mm Cement plaster finished with a floating coat of neat cement of mix 1 : 4 ( 1 cement : 4 fine sand) |
| 5 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix) |
| 6 | Providing and laying Vitrified anti-skid tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600 mm |
| 7 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600 mm |
| 8 | Providing and Fixing vitrified wall tiles with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, with spacers of 3mm including epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of tile1200x600 mm |
| 9 | Providing & fixing PVC pipe heavy duty Type-B (prince, Finolex), Water or Vent pipe with cowl. And necessary bends , junctions, reducers, rubber washers , adhesives , complete job also including cost of all fittings and fixture like bends Tee's Collars Sockets Spigots ,reducers ,traps, washers, Earth work, Sand Cushion and Back Filling wherever required as per the direction of Engineers in charge. |
| 10 | 50 mm diameter |
| 11 | 75 mm diameter |
| 12 | 110 mm diameter |
| 13 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C automatic flushing cistern, with fittings, standard size G.I./ PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and in C.P brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required: Range of three squatting plates with 10 liter P.V.C. automatic flushing cistern. |
| 14 | Providing/fixing of C.P fittings of approved make as approved by EIC |
| 15 | Angle value |
| 16 | Bib cock |
| 17 | Sink mixer |
| 18 | Basin mixer |
| 19 | Wall mixer with hand shower |
| 20 | Waste pipes |
| 21 | Grating s.steel |
| 22 | Towel Ring |
| 23 | Soap case |
| 24 | CP connection |
| 25 | Towel Rod |
| 26 | Toilet paper holder |
| 27 | Mirror 600x450 |
| 28 | Soap dispenser |
| 29 | CP hook |
| 30 | Providing and fixing white vitrous wash basin with C.I. brackets, with pedestal including all necessary fitting and fixtures complete job. inclusive all as per direction of Engineer Incharge |
| 31 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 32 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick |
| 33 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work. |
| 34 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 36 | Providing and fixing in position 16 MM mm thick full body vitrified outdoor tiles in 1:3 mix cement mortar in paths with approved colour, design and pattern as per directions of Engineer Incharges including all carriages mechanical/manual upto site of work as directed by Engineer Incharge complete job all inclusive. |
| 37 | Providng and applying Touch wood of approved brand and manufacture to give an even shade, one or more coats on old work. |
| 38 | Providing and fixing Imported wooden panelling high tech knotted imported of approved make, design as directed by the Engineer incharge at time of execution of work including labour, material, wastage, make rait wood, fixing of framework of of imported budloo wood jamps in soffit and fixing in position, cost of screws, nails, applying of touchwood of approved brand, including cost of scaffolding upto height of fifth floor complete job; all inclusive 10mm thick |
| 39 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. |
| 40 | Internal work-exposed on wall with clamps at 1.00 meter spacing PN-16 pipe , 40mm OD(SDR-7.4) |
| 41 | Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 42 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 43 | PN-16 pipe , 32mm OD(SDR-7.4) |
| 44 | Providing Fixing of Aluminum/Stainless Steel Hardware fixtures of approved make including necessary screws etc: all inclusive |
| 45 | Hinges 5\\" |
| 46 | Handles 6\\" |
| 47 | Tower Bolts 4\\" |
| 48 | Tower Bolts 6\\" |
| 49 | Eye Hooks |
| 50 | Magnetic catchers |
| 51 | Handles (4\\") |
| 52 | Hydrualic hinges |
| 53 | Fancy Handles 4\\" |
| 54 | Providing and fixing of in built locks of link lock or equivalent as per directions of EIC. |
| 55 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm |
| 56 | Providing and fixing 30mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge Imported KD Wood |
| 57 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Imported KD Wood 30mm Thick |
| 58 | Engagement of carpenter for easing out doors, windows, etc as directed by Engineer Incharge excluding cost of fixtures complete job. |
| 59 | Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete. With Galvanized M.S. Wire gauge with wire of dia 0.63 mm With 2nd class teak wood beading 62x19 mm |
| 60 | Providing and fixing 3.5mm thick glass panes of standard quality in glazed shutter including cost of wooden beading, nails etc. excluding the portion of glass in groves complete job. all inclusive. |
| 61 | Providing, installation, commissioning and testing horzontal/vertical Hot water Geyzer of approved make including fixing with bolts/ fasteners/PVC connection etc. Venus, Recold, Hindware, Havells, Jaquar, Crompton of required capacity fittings and fixtures all complete wherever required in the course of completion. complete including cutting and making good the walls, wherever required job. 35 liters |
| 62 | Labour charge for taking and refixing of existing geysers with all labours inc necessary fittings complete job. |
| 63 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 64 | 15mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix 1 : 4 ( 1 cement : 4 fine sand) |
| 65 | Disposal of un-serviceable material including rubbish/vegetation outside municipal limits by means of mechanical transport including loading unloading complete; all inclusive as directed by Engineer Incharge at an average lead of 10 Kms |
| 66 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 67 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040mm bowl depth 250mm |
| 68 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres. All kinds of soil : |
| 69 | Providing & laying of stone soling hand packed in foundation and plinth including ramming, watering, compaction & lead lifts all carriages upto site of work complete job; All inclusive. |
| 70 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with |
| 71 | 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 72 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 73 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 74 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 75 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 76 | Foundations, footings, bases of columns etc. for mass concrete |
| 77 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 78 | Columns, pillars, piers, abutments, posts and struts. |
| 79 | Brick work with machine moulded perforated bricks of class designation 12.5 conforming to I:S: 2222 upto Plinth level including making horizional and vertical grooves 10mm wide 12mm deep comlete in cement mortar 1:6 ( 1 cement : 6 coarse sand ) including curing complete With modular bricks including extra for superstructure above plinth level upto floor V level including carriage of materials complete job as directed by Engineer Incharge |
| 80 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 above plinth including curing in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) Excluding cost of Bricks (Labour Charges) |
| 81 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 82 | Supplying and filling of local earth (Including royalty) by mechanical transport including loading, unloading, consolidation including all carriages of material upto site of work as directed by Engineer Incharge all inclusive |
| 83 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture |
| 84 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 85 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm) |
| 86 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 87 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 88 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm) |
| 89 | Providing and Fixing 19mm thick plyboard of approved quality and brand for cabinets/ Almirah fixed in position, including carriage complete job as per the directions of Engineer Incharge.;all inclusive. |
| 90 | Providing and Fixing 10mm thick plyboard of approved quality and brand for cabinets/ Almirah fixed in position, including carriage complete job as per the directions of Engineer Incharge.;all inclusive. |
| 91 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position Budloo / Fir wood |
| 92 | Providing and Fixing 0.8mm laminated dulmica/sunmica of approved brand and colour including fixed with approved adhesive properly complete job as directed by Engineer Incharge.;all inclusive. |
| 93 | Carriage of materials by way of mechanical transport including loading unloading leads lifts from source to site of work complete job. |
| 94 | Sand and Aggregates for an average lead of 20Kms |
| 95 | Bricks for an average lead of 20Kms |
| 96 | Electrical Part |
| 97 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Polycab/Finolex/ Anchor/Havells/RR Kabel/KEI Make) in surface / recessed medium class PVC conduit( Anchor HMS,Finolex,polycab Green ,Ravendra Green ,Astral, Supreme) , with modular switch, modular plate, suitable GI box Havells(Crab-Tree Athena)/Legrand(Myris)/ Anchor Rooma Plus/Schneider(Zencelo)and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required as per IS Standard. Group C |
| 98 | Re- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Polycab/Finolex/ Anchor/Havells/RR Kabel/KEI Make) in existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required as per IS Standard. Group C |
| 99 | Supplying and fixing modular blanking plate with modular plate & switch box excluding modular plate Havells(Crab-Tree)/ Legrand(Myris) /Anchor Rooma Plus/ Schneider(Zencelo) as required as per IS standard |
| 100 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, Havells (Crab-Tree Athena)/ Legrand(Myris)/ Anchor Rooma Plus/Schneider(Zencelo)connections etc. as required. |
| 101 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, Havells(Crab-Tree Athena)/ Legrand(Myris)/ Anchor Rooma Plus/ Schneider (Zencelo) connections etc. as required. |
| 102 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, Havells(Crab-Tree Athena)/ Legrand(Myris)/ Anchor Rooma Plus/Schneider(Zencelo)connections etc. as required. as per IS standard |
| 103 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable (Polycab /Finolex / Anchor/Havells / RR Kabel/KEI Make) in surface/ recessed medium class PVC conduit ( Anchor HMS,Finolex,polycab Green ,Ravendra Green ,Astral, Supreme) as required as per IS Standard. |
| 104 | 2 X 1.5 sq.mm+1 X 1.5 sq. mm earth wire. |
| 105 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 106 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 107 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet,(Havells, Schneider Electric, L&T Selvo Legrand ,Anchor , C&S ) with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. |
| 108 | Supply and fixing 16 way (Double door) (SPN type) MCB distribution board (Havells , Schneider , Siemens , L&T , Legrand , ABB,Hager, Crompton Greaves) 240V on recess /surface completed with cooper bus bars neutral bars earth bars including earthing |
| 109 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker (Schneider Electric, Havells, Legrand, Siemens, ABB, Anchor , Polycab, Finolex, L&T Electrical & Automation, and Hager )suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 110 | Single pole |
| 111 | single pole & Neutral |
| 112 | 32A (DP) |
| 113 | Supply, Installation, Testing and Commissioning of Ceiling Fan ( Crompton, Havells, Usha, Atomberg, Orient Electric, Bajaj Electricals, V-Guard, Luminous, Polycab, and Anchor) compliant to IS 374:2019 1200mm Sweep suitable for 230 V, 50 Hz, single phase AC supply, fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required |
| 114 | Supplying and fixing two module stepped type electronic fan regulator Havells(Crab-Tree Athena)/ Legrand(Myris)/ Anchor Rooma Plus/ Schneider (Zencelo) with the modular plate switch box including connections etc. as required. |
| 115 | Supplying and fixing of wall fan ( Crompton, Havells, Usha, Atomberg, Orient Electric, Bajaj Electricals, V-Guard, Luminous, Polycab, and Anchor) 400mm suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required. |
| 116 | Supply & fixing of 3 Pin 5A ceiling rose (Havells, Anchor , Goldmedal, Cona, Kolors, and Lyteron ) the existing junction box /as required including connections |
| 117 | Supply, Installation, Testing and Commissioning of heavy duty 300mm dia sweep PVC body, 900±10% RPM Exhaust fan( Crompton, Havells, Usha, Atomberg, Orient Electric, Bajaj Electricals, V-Guard, Luminous, Polycab, and Anchor) with guard and mounting arrangement. Commercial series |
| 118 | Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) Philips/Wipro/Crompton /Bajaj /Surya/ Panasonic /Halonix )SMD type of Powder coated die cast /Extruded aluminum Body including trim material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.?0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, \\"complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required 22 watt . |
| 119 | Supplying Installation, Testing and Commissioning of LED RGB/RGBWW/ RGBNW/ RGBA/RGBW (Philips /Wipro/Crompton /Bajaj /Surya/ Panasonic /Halonix) suitable for interior use having IP65 rating (as per site requirement). Flexible light strip of 5 mtr standard length with 12-15 Watt per meter. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. Minimum System lumens 450 lumens/meter and System Lumen Efficacy > 30lm/w. Luminaire light beam spread - 100-110°, The Strip should have IP 65 protection and is offered IP 65 rated connectors to join the LED Strips in continuity. The luminaire must be offered with Aluminium channel for mounting the strip lights. The product should be complete with all accessories and Driver. Lifetime of complete luminaire (LED, Driver, Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 24 V DC, Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. |
| 120 | supply ,installiation ,testing and commissoining of adjustable wall Lights LED COB focus 12-15w (Philips /Wipro/Crompton /Bajaj /Surya/ Panasonic /Halonix) |
| 121 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., (Philips /Wipro/Crompton /Bajaj /Surya/ Panasonic /Halonix) of Powder coated die cast / Extruded aluminium Body (Thickness ? 1.20 mm)body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.?0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required 36 watt |
| 122 | Supply/Installation/Testing and Commissioning of 24 watt 4-feet long LED batten 6000/6500k Light (Philips/Wipro/Crompton /Bajaj /Surya/ Panasonic /Halonix )having extruded aluminium heat sink with anti-glare diffuser with energy efficient electronic driver CRI greater than 80 with minimum sytem lumens 4000 and including connection with multistrand copper conductor 3-core cable etc as required at site with burning hours greater than 50000 Hours having system lumens 110 Lm/watt |
| 123 | Supply ,fixing and commissioning of Electric Fly Catcher/ Killer blue colour 40W 2ft Professional Indoor type Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender