Tender For Water Proofing Treatment And Other Miscellaneous Civil Works Including Repairing Of Power Room Wall At Satyabala T.E. Building, Howrah
Tender Value
16.16 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
2 days left
EMD
32336
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Howrah → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Water Proofing Treatment And Other Miscellaneous Civil Works Including Repairing Of Power Room Wall At Satyabala T.E. Building, Howrah
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 2 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 4 | In cement mortar |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 6 | Of area 3 sq. metres and below |
| 7 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: |
| 8 | Channels, angles, tees and flats |
| 9 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 10 | Asbestos cement sheet |
| 11 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 12 | 150 mm dia pipe |
| 13 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 14 | Carriage of materials by Mechanical Transport including loading, unloading and stacking : |
| 15 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. |
| 16 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 17 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 19 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 20 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 22 | Suspended floors, roofs, landings, balconies and access platform |
| 23 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 25 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 27 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 28 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 29 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 30 | Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. |
| 31 | Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15) |
| 32 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 33 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 34 | Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. |
| 35 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 36 | Grading roof for water proofing treatment with |
| 37 | Cement mortar 1:4 (1cement : 4 coarse sand) |
| 38 | 12 mm cement plaster of mix : |
| 39 | 1:4 (1 cement: 4 fine sand) |
| 40 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 41 | 1:6 (1 cement: 6 fine sand) |
| 42 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 43 | 1:4 (1 cement: 4 fine sand) |
| 44 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 45 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 46 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 47 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 48 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 49 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 51 | Two or more coats on new work. |
| 52 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 53 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 54 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : |
| 55 | 3 mm thick |
| 56 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. |
| 57 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 58 | 75 mm average thickness |
| 59 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 60 | Bars upto 12 mm diameter |
| 61 | Bars above 12 mm diameter |
| 62 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 63 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 64 | Uprooting and removing small plants from the surface of walls, parapet, etc. at any height by cutting chase for removing roots and using necessary chemicals etc. to prevent further growth of plants and mending good damages complete. |
| 65 | Small plant of girth of exposed stem up to 75mm |
| 66 | Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site by chipping/ scrapping and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge. |
| 67 | Up to all floors |
| 68 | Providing and fixing uPVC pipes (SCH 40 uPVC as per ASTM D- 1785 pipes) including all uPVC plain and brass threaded fittings. Including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in charge. Internal work- Exposed on wall |
| 69 | 40 mm Nominal bore. |
| 70 | Providing scaffolding of single layer with bamboo made of avg 75mm dia with adequate bracing, ties, ropes etc for strong durable and workable for executing all items of work where required including provision of steps for measurement purpose, making platform and proper maintanance of scaffolding to make it durable during entire period of works including covering the entire area with Protection Net to resist any falling concrete and other object and removal of the same after completion of the work cleaning the site as per direction of Engineer in Charge. |
| 71 | Felling of trees like banyan, pipul etc from compound walls, building walls, cornices etc by making scaffolding where necessary including cutting of trunks and branches, application of chemicals/weedicides to the remaining portion to kill the growth of tree and ultimately removing the roots from the walls by cutting walls and mending good complete. ( The rate is inclusive of the mending good the walls with bricks/concretes/plasters and disposing of branches/trunks to vats inside compound for further disposal) |
| 72 | a) Of girth above 30 cm upto 60 cm (measured above 1.0 m from GL ) |
| 73 | Dismantling Over Head PVC water tank by carefully removing all the connections upto 5000 litres and refixing the tank at same place after repair or at new position complete as per direction Engineer-in-charge. (Rates inclusive of rubber/PVC gaskets, PVC weldings for repairs complete) |
| 74 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 75 | 160 mm diameter |
| 76 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 77 | 160 mm diameter |
| 78 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 79 | Bend 87.5° -160 mm dia |
| 80 | Credit value for dismantled /unserviceable materials |
| 81 | Galvanised /M S materials |
| 82 | C.I./ S.C.I. pipes. |
| 83 | Bricks Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender