Tender For Special Repair To Sewage Line Including Manhole And Covers Of P-11, 12, 13 (Mes Ib) And Special Repair To Boundary Wall And Existing Security Fencing On Boundary Of Officer Mess At Emb Hq Under Ge (West) Colaba, Mumbai
Tender Overview
Project Description
Tender for Special Repair To Sewage Line Including Manhole And Covers Of P-11, 12, 13 (Mes Ib) And Special Repair To Boundary Wall And Existing Security Fencing On Boundary Of Officer Mess At Emb Hq Under Ge (West) Colaba, Mumbai
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil, complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m in deep for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil, complete all as specified and directed. |
| 3 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and directed. |
| 4 | Removing excavated soil to a distance of outside MoD land and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed. |
| 5 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 200 mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes, complete all as specified and directed.Note :- Excavation and earth work shall be measured and paid separately. |
| 6 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 200mm bore pipe, complete all as specified and directed. |
| 7 | M&L for 200mm bore reinforced concrete pipes, class NP-3 (ISI marked) with collars, laid in trenches and jointed, complete all as specified and directed by Engineer-in-charge. |
| 8 | Demolition concrete (reinforced) in ground floors and pavings n. exc 15 cm thickness, complete all as specified and directed. |
| 9 | M&L for RCC B-0 (1:2:4) 12.50mm graded aggregate (nominal mix) as in Foundations, including rafts, footings, foundation beams; plinth beams bases for columns, etc basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 10 | S&F TMT bars 10 mm dia cut to length bent to shape required including cranking binding with MS wire (annealed) not less than 0.9 mm dia, complete all as specified and directed. |
| 11 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough surface finished, complete all as specified and directed. |
| 12 | S&F in repairs of heavy duty cast iron manhole cover including frame of suitable size, complete all as specified and directed. |
| 13 | S & F in repairs 900mm x 600mm FRP manhole cover of 10 ton loading capacity with frame over manhole coping concrete, complete all as specified and directed. |
| 14 | S&F in repair 110 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls, complete all as specified and directed.Note : upto any height and including necessary scafolding. |
| 15 | S&F in repair 75 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls, complete all as specified and directed.Note : upto any height and including necessary scafolding. |
| 16 | S&F 75mm dia PVC (SWR) bends with access doors any radius, complete all as specified and directed. |
| 17 | S&F 110 mm dia PVC (SWR) bends with access doors any radius, complete all as specified and directed. |
| 18 | S&F 75 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door, complete all as specified and directed. |
| 19 | S&F 110 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door, complete all as specified and directed. |
| 20 | S&F 75 mm dia PVC (SWR) vent cowl, complete all as specified and directed. |
| 21 | S&F 110mm dia PVC (SWR) vent cowl, complete all as specified and directed. |
| 22 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level), complete all as specified and directed. |
| 23 | Dismantling floor, hearth or wall tiling including cement mortar, removeing and rubbish off the premises, complete all as specified and directed. |
| 24 | M&L for PCC 75 mm thick type B-1 1:2:4 (20 mm graded stone aggregate) laid in alternative as in plinth protection including finished the surface even & fair without using extra cement, complete all as specified and directed. |
| 25 | Plain Cement Concrete Type D-2 1:4:8 (using 40 mm graded granite stone aggregate) as in sub base of flooring, foundations, filling and mass concrete, complete all as specified and directed. |
| 26 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, with mixture of with white and grey cement in equal proportion and no pigment jointed and pointed in neat cement slurry in floors including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes, complete all as specified and directed. |
| 27 | M&L for even spreading of 25 mm thick layer of sand cushioning, complete all as specified and directed. |
| 28 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment, complete all as specified and directed.Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. |
| 29 | M&L for Providing, cement concrete Type B-0 1:2:4 (using 12.5mm graded granite stone aggregate) in copings, kneelers, apex stones bed plates, kerbs not provided for in Item water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 30 | Demolition of brick work /stone masonry built in cement mortar incl. coping of any description, complete all as specified and directed. |
| 31 | Material and Labour for Brick work with sub class 'B' brick straight or curved on plan exc 6 mtr mean raddius built in CM 1:6, complete all as specified and directed. |
| 32 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces, finishing the surfaces even and smooth with out using extra cement, complete all as specified and directed. |
| 33 | Dismantling wrought iron or mild steel work of any description specifically provided for gates, staircase railings, framed truss etc, complete all as specified and directed. |
| 34 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections Fe 410 -W (Gde- E- 250) quality- AFe) including distance pieces, cleats etc, complete all as specified and directed. |
| 35 | M&L for Preparation of new steel surfaces of any description over 10cm width or girth and application of two coats of synthetic enamel paint over one coat of red oxide primer etc, complete all as specified and directed. |
| 36 | M&L for PCC type C-2 1:3:6, 40 mm graded aggregate) in foundations, filling and mass concrete, complete all as specified and directed. |
| 37 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed, complete all as specified and directed. |
| 38 | Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 39 | Materail and labour for 20-25 mm average thick ready mix plaster in multi layer of make brand - ACC's Accoplast/CK birla's Aerocon / Speed dry mix Ecoplaster / Magic plast/ Build well, mixed with liquid water proofing compound on other than fair face, complete all as specified and directed. |
| 40 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 41 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 42 | Demolition of cement concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed. |
| 43 | M&L PCC 1:2:4 type B-0, (using 12.50 mm graded crushed stone aggregate) as in coping/cills including necessary form work, weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 44 | S&F for joist, channel, angle or tee sections or MS Flats fixed independantly without connecting plates, etc Fe 410-W (Gde-E- 250) quality- A (cut to ordinary lengths i.e within 20mm of length indicated) as in frame work for Galvalume / CGI chajjas, complete all as specified and directed. |
| 45 | S&F in repairs Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and directed. |
| 46 | S&F in repairs Concertina coil with punched tape of 600mm dia centre core wire shall be minimum 2.5mm dia of mild steel wire confirming to IS 280-2006. Galvanised coating of steel concertina coil shall confirm to the requirements as laid down for medium coated wire in IS 4826 \\"Hot dipped galvanised coating of round steel wires\\" concertina coil shall be fixed in dimond shape with the help of dovetail to handle and spikes shall be fixed at both end of coil, minimum staight length of the wire 150 RM of 10 RM of work, minimum weight 13.5 Kg for 10 RM of work i.e 90 gm/RM of wire, complete all as specified and directed. |
| 47 | Demolition of Stone slabs and tiles laid bedded and jointed in any mortar of any description or thickness in floors, aprons etc, complete all as specified and directed. |
| 48 | Material and labour for crushed sand filling under precast interlocking paver blocks and all other similar works, complete all as specified and directed. |
| 49 | M&L for cement concrete type C-2 1:3:6, 40 mm graded aggregate) in sub base 100mm thick complete, complete all as specified and directed. |
| 50 | M&L rubber moulded glossy finished precast concrete interlocking paver block of any shape and size confirming to IS 15658 -2006 of 60 mm thickness, M-40 Grade with grey cement and pigment, laid over sand cushning including compaction of paver blocks using surface vibrator, complete all as specified and directed.Note :- Sand cushioning shall be paid separately under relevant item. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender