Project Description

Tender for special Repair To Sewage Network To Prevent Frequent Choking, Blocking And Accumulation Of Sewer Water In New Md Lines Under Ge Golconda

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-Nov-2026
2 19-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-Nov-2026

BOQ

Name of Work:- SPL REPAIR TO SEWAGE NETWORK TO PREVENT FREQUENT CHOKING, BLOCKING AND ACCUMULATION OF SEWER WATER IN NEW MD LINES UNDER GE GOLCONDA
Sl. No. Item Description
1BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8172/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: SPL REPAIR TO SEWAGE NETWORK TO PREVENT FREQUENT CHOKING, BLOCKING AND ACCUMULATION OF SEWER WATER IN NEW MD LINES UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES
2Thorough cleaning of sewage manholes / inspection chambers of any size and depth upto 1.2m from GL. The work involves: (a) Opening of manhole covers and providing adequate ventilation to ensure the escape of toxic gases (H2S, Methane). (b) Manual or mechanical removal of accumulated sludge, silt, grit, solid waste, and any other obstructions from the floor, benching, and channel of the manhole. (c) Scrubbing of internal walls and benching to remove fungal growth/algae. (d) Immediate removal and carting away of the extracted sludge from the premises in sealed containers to the outside of MD land complete all as specified and directed.
3Thorough cleaning of sewage manholes / inspection chambers of any size and depth more than 1.2m from GL. The work involves: (a) Opening of manhole covers and providing adequate ventilation to ensure the escape of toxic gases (H2S, Methane). (b) Manual or mechanical removal of accumulated sludge, silt, grit, solid waste, and any other obstructions from the floor, benching, and channel of the manhole. (c) Scrubbing of internal walls and benching to remove fungal growth/algae. (d) Immediate removal and carting away of the extracted sludge from the premises in sealed containers to the outside of MD land complete all as specified and directed.
4Cleaning of septic tanks completely by empting the liquid / semi solid foul contents mechanically as specified completely, cleaning inlets and outlets etc including disposal of soil sludge outside MD land complete all as specified and directed.
5Systematic clearing of accumulated solid waste, silt, grit, and sludge from internal / external sewage pipelines / hume pipe culverts of diameters up to 300mm. The process includes: (a) Use of high-pressure hydro-jetting machine with specialized nozzles to break down hardened silt and flush it towards the downstream manhole. (b) Where mechanical jetting is restricted, use of flexible sewer rods with appropriate attachments (cutters/scrapers) to dislodge blockages. (c) Continuous flushing with water to ensure all dislodged debris is captured at the manhole and removed manually. (d) Verification of the \\"clear bore\\" by performing a ball test or a flow-gradient test between two consecutive manholes. Work includes the disposal of all extracted waste in sealed containers to the outside of MD land complete all as specified and directed.
6Systematic rectification of leakages at the entry and exit pipe junctions within the manhole by Chipping away failed cement mortar or old \\"benching\\" around the pipe circumference to a depth of 50mm. And applying a high-strength, fast-setting, non-shrink hydraulic cement or epoxy-modified mortar to seal the annular space between the pipe and the wall complete all as specified and directed
7Excavation in trenches n.exc 1.50m wide and n.exc. 1.50 m depth and getting out in hard/dense soil complete all as specified and directed.
8Excavation in trenches n.exc 1.50m wide and depth exc. 1.50 m but n. exc 3 m and getting out in hard/dense soil complete all as specified and directed.
9Excavating over areas, n exc 1.5 m deep and getting out mud, vegetation, debris of brickwork, concrete etc complete all as specified and directed
10Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed.
11Earth work in excavation in ordinary rock by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed.
12Earth work in excavation of all kind of soil by mechanical means (Hydraulic excavator) means over areas (1.5 m in width as well as 10 sqm on plan) n.exc. 1.50 m depth including getting out and disposal of excavated earth lead upto 50 m complete all as specified and directed
13Earth work in excavation of all kind of soil (including debris of brickwork, concrete, vegetation etc) by mechanical means (Hydraulic excavator) means over areas (1.5 m in width as well as 10 sqm on plan) depth exc. 1.50 m but n. exc 3 m including getting out and disposal of excavated earth lead upto 50 m complete all as specified and directed
14Demolition and breaking up drain pipes (SGSW/AC/PVC/RCC) set in cement mortar, Internal dia of pipe upto 110 mm, including fittings etc complete all as specified and directed.
15S & F 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to wall complete all as specified and directed.
16S & F 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to wall complete all as specified & directed.
17S&F for PVC (SWR) branch piece, single (single Y) equal or unequal, bore of pipe in 110 mm, etc complete all as specified and directed.
18S&F for PVC (SWR) branch piece, single (single Y) equal or unequal, bore of pipe in 75 mm, etc complete all as specified and directed.
19M&L in repair 110 mm bore PVC( SWR ) bend with oval access doors complete all as specified and directed.
20M&L in repair 75 mm bore PVC( SWR ) bend with oval access doors complete all as specified and directed.
21M & L 110 mm bore PVC( SWR ) junction single ,(singleT) equal or unequal, including taking down complete all as specified and as directed.
22M & L 75 mm bore PVC( SWR ) junction single ,(singleT) equal or unequal, including taking down complete all as specified and as directed.
23M & L 110 mm bore PVC( SWR ) reducer, including taking down complete all as specified and as directed.
24S & F for PVC (SWR) vent cowl, bore of pipe in 75 mm, etc complete all as specified and directed.
25S & F for PVC (SWR) vent cowl, bore of pipe in 110 mm, etc complete all as specified and directed.
26M&L in repair for 75 mm PVC Nahani / floor trap plain with grating including jointing with solvent cement complete all as specified and directed
27S&F in repair for 20mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor. complete all as specified and directed
28M&L for Cutting into existing manholes for connecting new drains of internal dia of pipe 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed.
29M&L for Cutting into existing manholes for connecting new drains of internal dia of pipe 200 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed.
30M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and moorum filling including excavation for laying of drain pipes all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
31Dismantling of sewage drain pipes of dia 150mm, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
32Dismantling of sewage drain pipes of dia 200mm, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
33M & L for Reinforced cement concrete pipes, 150mm bore, class NP2 laid and jointed complete with collars laid in trenches complete all as specified and directed.
34M & L for Reinforced cement concrete pipes, 200mm bore, class NP2 laid and jointed with collars laid in trenches complete all as specified and directed.
35M & L for Reinforced cement concrete pipes, 300mm bore, class NP2 laid and jointed with collars laid in trenches complete all as specified and directed.
36M & L for Double Wall Corrugated (DWC) HDPE pipes,150mm internal dia bore and a stiffness class of SN8 (confirming to IS 16098-Part 2), laid in tranches and jointed with couplers / sockets etc complete all as specified and directed.
37M & L for Double Wall Corrugated (DWC) HDPE pipes, 200mm internal dia bore and a stiffness class of SN8 (confirming to IS 16098-Part 2), laid in tranches and jointed with couplers / sockets etc complete all as specified and directed.
38Cutting holes into or through brick walls built in cement mortar for removing/refixing PVC/CI fittings and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, superficial area exc 150 sq. cm and n exc 400 sq. cm each complete all as specified and as directed.
39Cutting holes into or through brick walls built in cement mortar for removing/refixing PVC/CI fittings and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, superficial area exc 400 sq. cm and n exc 0.10 sq. m each complete all as specified and as directed.
40M&L moorum/red bajri filling and laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
41Returning, filling in including spreading, levelling, watering and well ramming in layers n. exc 25 cm all as specified.
42Removing excavated material exc. 250 m but n exc. 1.5km and depositing where directed complete all as specified and directed.
43Removing excavated material and depositing outside md land complete all as specified and directed.
44Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
45M&L for non skid coloured ceramic tiles 7-8 mm thick (square/ rectangular ) area of each tile exc 0.06 sqm but n.exc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match the surface, laid over and including 15mm thick screed bed or bedding in cement mortar (1:6),complete all as specified and directed.
46M&L for Glazed ceramic tiles in vertical surface 375X250X7mm / 300x450x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match , laid over and including 10mm thick rendering in cement mortar(1:4) as backing coat, complete all as specified and directed.
47S & F in repairs Vitreous china premium/ 1st quality wash down water closet EWC white/ ivory/off white (square pattern including all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified and directed.
48S & F in repairs plastic water closet seat and cover for pedestal pan and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
49S&F in repairs PVC valve less syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe complete all as specified and directed.
50M&L for cleaning/removing all vegetation, bushes/small trees on wall and making good the surfaces with PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) or rendering in CM (1:3) including removing spoils obtained to a distance not exc 50 metre and depositing complete all as specified and directed.
51Cutting & trimming of tree branches any girth and size touching to sewage lines and cleaning the distance 1.5 mtr both sides of sewage line with in a gap of span 40 mtrs each and removing the same cleaning the site all as specified and directed.
52Demolition of brick work or stone masonry, built in cement mortar complete all as specified and directed.
53M & L brick work with fly ash bricks built in CM 1:6 on plan exc 6 mtr mean radius all as specified.
54Taking down cement plaster on brick or stone walls including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
55M&L 15 mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces of walls finished the surface even & smooth without using extra cement complete all as specified and directed.
56Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed
57M & L for Plain cement concrete (1:3:6) type C2 (40mm graded stone aggregate) as concrete bed to drain pipes of any dia including packing under, and haunching against the sides of pipes after they are laid and tested including demolition of existing concrete bed, haunching and pipe, complete all as specified and directed.
58M & L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
59M & L PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) set in CM 1:4 as in benching to manholes complete all as specified and directed.
60M & L PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in copping including necessary form work all as specified.
61Demolition of cement concrete of any description in any position (Reinforced) complete all as specified and directed.
62S & F TMT bars 6mm dia and over upto and including 8mm dia as in reinforcement, including binding with and including tying with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
63M & L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate as in pre-cast cover slabs for manholes including necessary form work set in CM 1:4 all as specified. (Reinforcement will be measured & paid separately) complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58135163
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40.77 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Sewage Network To Prevent Frequent Choking, Blocking And Accumulation Of Sewer Water In New Md Lines Under Ge Golconda
Basic Detail
Tender No 8172/E8
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 19 Nov 2026
Submission Date 24 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 40.77 Lakhs
Tender Fee 500
EMD 82000
Exemption Available
Document List
350794df-cce1-40e4-aa12-9072f0663db2.html
8172NIT.pdf
8172Tender.pdf
BOQ_891533.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 24, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

350794df-cce1-40e4-aa12-9072f0663db2.html

pdf

8172NIT.pdf

pdf

8172Tender.pdf

xls

BOQ_891533.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender