Housing Urban and Rular Development Government Departments Closing in 8 days TDR #58134444

Tender For Upgaration Of Soil Testing Lab In Agriculture Office At Ferozepur

Issued by Government Departments · Firozepur, Punjab
Tender Value
43.26 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
8 days left
EMD
86523
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgaration Of Soil Testing Lab In Agriculture Office At Ferozepur

BOQ

Name of Work:- UPGARATION OF SOIL TESTING LAB IN AGRICULTURE OFFICE AT FEROZEPUR
Sl. No. Item Description
1Civil WorkEarth work in excavation in foundations , trenches etc. in all kinds of soil where pick jumper work is notinvolved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation
2Cement concrete 1:4:8 with stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type.
3First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
4Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at1.65 Kg per sqm laid hot and sanded
5Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
6First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
7Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
8Cold twisted detormed (Ribbed/Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works,where not including in the complete rate of RCC including bending and binding placing in position complete
9Reinforced cement concrete M-30 mechanically mixed using voluemetric type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. (6449-216+136 = 6369)
10Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
11Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
12Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16
13Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe (ring fitted type-A) as per IS: 4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-incharge.
14Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
15Base course of floor consisting of100mm thick cement concrete1:8:16 with stone aggregate 40mm gauge and 100mm Fine sand filling using mechanical mixer for mixing of material
16Providing and laying vitrified floor tiles Size 600x600 mm of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.
17Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete.(d) Doors and windows frame of size 161mm x 60mm with 40 mm wide double rebate weighing 4.05 kg per meter.
1812.5 mm thick cement plaster 1:5
1920mm Thick Cement Plaster 1:5 into Coat work (Outer face)
20Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps
21Cement Concrete 1:8:16 with Stome agreegate 40mm gauge mixing by mechanical means using concrete mixture volumetric type.
22First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
23Base course of floor consisting of100mm thick cement concrete1:8:16 with stone aggregate 40mm gauge and100mm Fine sand filling using mechanical mixer for mixing of material
24Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish withstrong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shap
25Conglomerate floor 40mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 and with stone aggregate 40mm gauge and 100mm fine sand filling. using mechanical mixer for mixing of material
26Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
27Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
28Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineer-in-charge) consisting of a pair of brackets, C.P. brass waste 40mm complete in all respect.A) Size 450 mm x 300 mm x 150 mm
29Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. *(i) Triple Layer Tanks
30Providing and fixing in position automatic brass Ball Cock in tanks.(i) 15mm i/d
31Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.(ii) C.P. brass Bib cock foam flow without flange
32Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.(b) C.P brass towel ring
33Providing & fixing in postion C.P. brass Sink Cock swinging casted spout (table mounted) of approved make (to the approval of Engineerin-charge) complete in all respect.
34Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete(a) ISI designation no I (Size of door up to 700mm)
35c) I.S.I Designation No. III (size of door 851mm to 1000mm)
36Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.(a) 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
37Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)Float glass panes of 5 mm thickness
38Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) :For fixed portion and chawkhats 110mm *140mm
39Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required 63mm*50mm
40Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge.4mm thick ACP Sheet
41Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
42Providing and Fixing in position collapsible steel shutters, with vertical channels 20mmx10mmx2mm and braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T iron 40mmx40mmx6mm with 38mm dia steel pulleys, complete with bolts, nuts, locking arrangements, stoppers, handles, etc. complete in all respects.
43Public Health ServicesExcavation manually in trenches with straight or open cutting in built up street/ lane having wall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineerin-charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15m and for all lifts and subsequent refilling, watering and dressing upto groung level, including removal of surplus spoil from the site upto 15 metre distance complete in all respects.
44Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. a) Through wall 11.43 cm thick
45b) Through wall 22.86 cm thick
46CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.a) SDR 11 CPVC pipes & fittings 20mm o/d
47b) SDR 11 CPVC pipes & fittings 25mm o/d
48Providing and Fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS-13592 of approved make (to the approval of Engineer in Charge ) inculding cutting joining wastage, but excluding cost of lead joining c) 90mm dia SWR UPVC Pipe line
49b) 110mm dia SWR UPVC Pipe line
50Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification (IS:1729) of approved make (to the approval of Engineer-in-charge) of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. minimum depth of water should be 150mm with a minimum seal 50mm. a) With 100mm x 75mm i/d Floor Trap (weighing 4.0 Kg)
51Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
52Providing and fixing jet spray with 2'-6\\" long PVC pipe. (b) With C.P. Brass nut
53Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
54Providing & fixing in position C.P brass sink cock with swimming spout (wall mounted) of approved make(to the approval of engineer in charge) complete in all respect
55Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.(ii)Size 550 mm x 400 mm x 815 mm
56Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.(i) Vitreous chinaware standard white pedestal for wash hand basin.
57Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect.(ii) C.P. Brass extension piece 75mm long
58Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. b) C.P brass towel ring
59Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. a) 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
60Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. (ii) C.P. brass Bib cock foam flow without flange
61Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.... as per xix) 63mm o/d PVC pipe of 4 Kgf. / sqcm Vent air pipe
62Providing, fixing, Jointing CPVC. Union couplings as per IS 1879 in CPVC. Pipe line complete in all respects (NS)a) 20mm I/d CPVC. Union
63c) 25 mm I/d CPVC. Union
64Providing, fixing and jointing ISI Marked Gun-Metal peet valves as per IS 778 complete as per 25mm I/d Gun Metal peet valves heavy pattern
65Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.i) Triple layer Tanks
66Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. a) PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut
67Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design(a) Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal
68Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineerin- charge) consisting of a pair of brackets, C.P. brass waste 40mm complete in all respect. (b)Size 470mmx370mmx180mm
69Base course of floor consisting of 100mm thick cement concrete 1:8:16 and with stone aggregate 40mm gauge and 100 mm fine sand sand filling using mechanical mixer for mixing of material
70Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
71Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
72EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.: ( C ) CPVC SDR 11 pipe & Fittings 25mm o/d
73Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. With F.P.S. bricks
74Providing & Fixing in postion stop cock / Angle valve of approved make (to theapproval of Engineer-in-charge ) complete in all respect.(C)C.P.brass 15mm Angle valve without flange
75(b) C.P.brass 15mm Concealed stop cock with flange.
76Providing and fixing in position C.P. brass soap dish of approved make (to theapproval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
77Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)ii)Size 550mmx400mm
78Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect
79Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) b) 110mm o/d
80C) 90mm o/d
81Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect.
82Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
83Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
84Providing and fixing in position CPVC. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. (NS)(C) CPVC. tank nipple 25mm i/d
85Construction of Platform complete as per Specification & Desired by Engineer in Charge (NS)
86Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (storedpressure) as per IS: 15683 complete with all accessories as per ManufacturesSpecification. ISI Mark complete in all respect. (b) 4 Kg. Capacity
87Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. (( C ) 4.5 Kg. Capacity
88Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with inputvoltage140-260voltssinglephase AC supply and output voltage 220±5% volts single phase AC supply having main silicon core copper wound stepup transformer with suitablenos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relayand single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp .meter and voltmeter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided: (b) Automatic Voltage Stablizer 4 KVA
89Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 3 Star Non Inverter Type having ISEER Rating 3.8 to 4.39 with MCB arrangement for installing OD units on terrace/ Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects including automatic voltage stablizer 3kva
90Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 3 Star Non Inverter Type having ISEER Rating 3.8 to 4.39 with MCB arrangement for installing OD units on terrace/ Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects including automatic voltage stablizer 3kva
91Providing & Installing 1 No. Pvc Straight Tubewell Of Size 150Mm Dia With 80Mtr. Depth Method Of Hand Boring Complete In All Respect . (Analysis Attached). (NS)
92Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of (1.50HP) reputed Make capable of delivering 72 LPM against a head of 32mtr along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including Column Pipe of suitable size 50 mm =30 mtr (in 3 mtr lengths submersible cable ( KSB / Finolex make) complete in all respects as per standard Specifications.
93Construction of SEPTIC TANK measruing 1.22 x 0.75 x 1.45 mt depth including RCC in bed, RCC roof slab, Providing and fixing RCC manhole cover 450 mm 450 mm & frame light duty, cement plaster inside, vent pipe with cowl etc. Complete in all respect. (as per drawing and design)
94Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. (a) Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer
95Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
96Electrical Services RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-(i) b Wiring fan point (With fan box)
97(ii) Wiring light point
98(iii) Wiring call-bell point
99(iv) Wiring 6Amp. wall socket point
100(v) Wiring 6Amp. Plug control comprising wall socket point
101(vi) Wiring 16/20Amp. power plug control point
102RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
103RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
104PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (Un-sheathed)
105Overall size 2.5sq.mm (Un-sheathed)
106Overall size 4sq.mm (Un-sheathed)
107Overall size 10sq.mm (Un-sheathed)
108PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
109COPPER EARTHING:Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
110MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Single Pole 6-32amp. (10kA, Curve-C)
111MCB Double Pole 40amp. (10kA, Curve-C)
112MCB Double Pole 50, 63amp. (10kA, Curve-C)
113SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-SP&N Double Door Distribution Board 12 way each
114Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48\\") having two ball bearing including flexible wire & petty material etc.complete in all respects as appd. and desired by the Engineer in-charge at site.
115Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
116Supply and erection of Heavy duty Exhaust Fans 300mm sweep 900RPM complete with aluminium louver shutter Canon Make, double ball bearing, longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
117Supply and erection of LED Flood Light 50watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58134444
AUTHORITY Government Departments
TENDER VALUE 43.26 Lakhs
LAST DATE 30-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Upgaration Of Soil Testing Lab In Agriculture Office At Ferozepur
Basic Detail
Tender No Tender Notice No 17 dated 14.10.2026
Bidding Type Tender
Location
City Firozepur
State Punjab
Key Dates
Publish Date 21 Oct 2026
Submission Date 30 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 43.26 Lakhs
Tender Fee 5000
EMD 86523
Exemption Not Available
Document List
50568666-8e2f-4381-adf9-23e8ad20d441.html
BOQ_362088.xls
DNITSOIL.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

50568666-8e2f-4381-adf9-23e8ad20d441.html

xls

BOQ_362088.xls

pdf

DNITSOIL.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender