Tender For Provision Of Volleyball Court Provided With Synthetic Flooring At Af Stn Carnicobar. 8736/E8
Tender Value
30 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
18 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
nicobar → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provision Of Volleyball Court Provided With Synthetic Flooring At Af Stn Carnicobar. 8736/E8
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing not exceeding 15 cm deep in soft/loose soil all as specified and as directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out getting out complete all as specified and as directed. |
| 3 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from baset complete all as specified and as directed. |
| 4 | Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary form work complete all as specified and as directed. |
| 5 | M&L for Pre-cast cement concrete block masonry with solid blocks using type C1(1:3:6) (20mm graded aggregate) ,size exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 6 | Material and labour for 15 mm thick rendering on brick/concrete wall surfaces in two layers in CM 1:4, finishing coat of 5mm thick, finished even and smooth without using extra cement complete all as specified and as directed. |
| 7 | Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 8 | Material and labour for hard core with broken stone or boulders of gauge not exceeding 63 mm, deposited, spread, and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface all as specified and as directed. |
| 9 | Material and labour for 100mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floors including necessary form work all as specified and as directed. |
| 10 | Material and labour for chequered cement concrete tiles 30cm x 30cm x 25mm with grey cement and pigment, hydraulically machine pressed, set, jointed and pointed in neat cement slurry to match colour of tiles, over and including 15mm thick screed in CM 1:6 in floors complete all as specified and as directed. |
| 11 | Material and Labour for 75mm thick plain cement concrete 1:2:4 type B2 using 40mm graded granite stone aggrgate as floor and other similar type of work, laid in panels and finishing cement concrete surface even and smooth Without using extra cement, complete all as specified and as directed. |
| 12 | Material and labour for rendering 10mm thick in Cement Mortar 1:4 on fair faces of internal brick walls or on concrete surfaces, finished even and smooth,without using extra cement complete all as specified and directed. |
| 13 | Providing all materials, labour, tools, plants, equipment and services for construction of asphalt base for outdoor volleyball court of standard dimensions (9 m x 18 m playing area and 15 m x 24 m overall area including free zone) complete in all respects, including dressing and preparation of existing soil after removal of grass, weeds and organic matter; compaction of prepared subgrade with 8–10 tonne roller; application of approved anti-termite and weedicide treatment over the entire area; providing and laying 85 mm and 65 mm compacted thickness Water Bound Macadam (WBM) layers in two stages with proper grading, watering, rolling, keying and interlocking of aggregates to achieve dense compaction and prevent settlement; providing and laying 40 mm compacted thick Hot Mix Asphalt course followed by 20 mm compacted thick Hot Mix Asphalt surface course; applying EPPT primer seal coat with stone dust over the finished asphalt surface; providing open saucer drain at the lower side for effective drainage; constructing 6 inch high retaining/edge wall for edge support and confinement; and completing the entire work to the required levels, slopes, compaction, and finish suitable for installation of synthetic acrylic sports surfacing and conforming to standards for National level tournament courts, all complete as specified and directed by the Engineer-in-Charge. |
| 14 | Material and Labour for Supply and installation of ITF certified 8 layers’ acrylic sports flooring system with thickness up to 3mm. The flooring should be certified by International Tennis Federation (ITF) and should have application as first layer of primer (100% acrylic latex-based emulsion to improve bond of acrylic court system to the asphalt surface having consumption ratio of 0.014 kg/sq. ft.), second layer of acrylic Resurface (Filling and smoothing asphalt or concrete surfaces in preparation for acrylic court system. It should also fill the surface chips, voids and conceals repairs while providing a smooth surface for colour coating. It should have a consumption ratio of 0.046kg/sq. ft.), Third, Fourth & Fifth layer of Uni-rubber liquid cushion layers at a consumption ratio of 0.10 kgs per sq. ft. altogether, Sixth & Seventh layer of Pre-coat (Quartz filled % 100 acrylic latex based textured topcoat with consumption ratio of 0.078kg/sq. ft.) and Eighth layer of Topcoat (100% acrylic latex polymer & colour coat for the finished surface to protect from UV). It should have consumption ratio of 0.023 kg/sq. ft.) on top of these 8 layers; the line marking should be done with Over line paint (100 % acrylic latex based high hiding line paints. It should have consumption ratio of 4 kg/court). The acrylic resurface must have silica sand infill to be embedded into it with consumption ratio of 0.065 kg/sq. ft. The product must be approved by the respective International Sports Federation and used at the Indian/International championships recognized by the respective Regional/International Sports federation, complete in all respects as per manufacturer's specifications and directions of the Engineer-in-Charge.Make: SportMaster/ Pidilite Industries/ Fosroc/ Conica/ Unica |
| 15 | Supply and fixing Heavy duty Volley Ball Pole Constructed with 3” hinges pipe epoxy painted, built in height adjustment & net wire tightening mechanism with the help of small key provided with the post all system as per international standard along with and including Volleyball net Nylon thick colour 4 sides tape 14 cm on top & 10 cm at bottom & both side Nylon Rope size 10X1 Mtr. As per ruling (With carry bag) Umpire chair made of MS round 25mm pipe structure stairs and provision of umpire for standing /sitting heigh. Make of Steel: Jindal/Sail/TATAMake of Net:Mikasa/Senoh/Molten |
| 16 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 17 | Removing excavated material (soil) n.exc 50 m and depositing where as directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 18 | Supply and Fixing LED flood light fitting 120Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistent including thermal management in multiple optics complete with IP 75 protection complete all as specified and directed by Engr-in-Charge. |
| 19 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 6 Sqmm 4 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 20 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 10 Sqmm 4 core with necessary fixing arrangements such as lugs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed.NOTE: Excavation, earth work shall be measured and paid for separately. |
| 21 | Supply and Fix High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches 40 mm bore with all acessoires for cable protection, complete all as specified and as directed. |
| 22 | Supply and Fix High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches 50 mm bore with all acessoires for cable protection, complete all as specified and as directed. |
| 23 | S&F M S tubular Pole minimum dia 4\\", 20 feet long 5mm thick confforming to IS1161 and wind pressure as per IS875 (Part 3) with M S base plate of size 350x350x16mm, fixing arrangement of M S angle for mounting 2Nos LED Flood light fittings including PCC work 1:2:4 for standing M S tubular pole (1/6 part of total length of pole), excavation/removing earth work, wiring work ,weather proof switch box/rectangular Sintex SMC FRP electrical jnction box with MCB din channel & stud TPN cable connector, MCB/switches for operating LED flood light fittings & painting work one coat or primer and 2 coats of synthetic enamel silver paint with finishing and welding, cutting & finishing including making arrangement of minimum 10 welded cross pipe for climbing in pole all work complete all as specified and directed. |
| 24 | Supply, install, test and commission of LT Control panel board, indoor type, double door, cubical type, padestal mounted, of suitable size, CPRI approved having, IP 65, independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of of 3.15 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame, front operated with locking arrangements suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar of 200.Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under : The LT Panel comprising of the following:- Please Enable Macros to View BoQ information |
| 25 | Supply, install, test and commission of LT Control panel board, indoor type, double door, cubical type, padestal mounted, of suitable size, CPRI approved having, IP 65, independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of of 3.15 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame, front operated with locking arrangements suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar of 200.Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing accessories all as approved and comprising as under : The LT Panel comprising of the following:- Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender